Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Implications of PREX-2 on the Equation of State of Neutron-Rich Matter

Laboratory experiments sensitive to the equation of state of neutron rich matter in the vicinity of nuclear saturation density provide the first rung in a “density ladder” that connects terrestrial experiments to astronomical observations. In this context, the neutron skin thickness of 208 Pb ($R$ $^{208}_{skin}$) provides a stringent laboratory constraint on the density dependence of the symmetry energy. In turn, an improved value of $R$ $^{208}_{skin}$ has been reported recently by the PREX collaboration. Exploiting the strong correlation between $R$ $^{208}_{skin}$ and the slope of the symmetry energy L within a specific class of relativistic energy density functionals, we report a value of L = (106 ± 37) MeV—which systematically overestimates current limits based on both theoretical approaches and experimental measurements. Here, the impact of such a stiff symmetry energy on some critical neutron-star observables is also examined.

79 ASTRONOMY AND ASTROPHYSICS↗

A mechanical rotator for neutron scattering measurements

We have designed and built a mechanical rotation system for use in single crystal neutron scattering experiments at low temperatures. The main motivation for this device is to facilitate the application of magnetic fields transverse to a primary training axis, using only a vertical cryomagnet. Development was done in the context of a triple-axis neutron spectrometer, but the design is such that it can be generalized to a number of different instruments or measurement techniques. Here, we discuss some of the experimental constraints motivating the design, followed by design specifics, preliminary experimental results, and a discussion of potential uses and future extension possibilities.

47 OTHER INSTRUMENTATION↗

Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap

The past two decades have yielded several new measurements and reanalysis of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the most precise lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magneto-gravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. In this work, the new measurement gives a free neutron lifetime of $τ_n$ = 876.3(2.4) stat (0.8) syst . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of models determined by neutron diffraction and proposed improvements to their validation and deposition

The Protein Data Bank (PDB) contains a growing number of models that have been determined using neutron diffraction or a hybrid method that combines X-ray and neutron diffraction. The advantage of neutron diffraction experiments is that the positions of all atoms can be determined, including H atoms, which are hardly detectable by X-ray diffraction. This allows the determination of protonation states and the assignment of H atoms to water molecules. Because neutrons are scattered differently by hydrogen and its isotope deuterium, neutron diffraction in combination with H/D exchange can provide information on accessibility, dynamics and chemical lability. In this study, the deposited data, models and model-to-data fit for all PDB entries that used neutron diffraction as the source of experimental data have been analysed. In many cases, the reported R work and R free values were not reproducible. In such cases, the model and data files were analysed to identify the reasons for this mismatch. The issues responsible for the discrepancies are summarized and explained. The analysis unveiled limitations to the annotation, deposition and validation of models and data, and a lack of community-wide accepted standards for the description of neutron models and data, as well as deficiencies in current model refinement tools. Most of the issues identified concern the handling of H atoms. Since the primary use of neutron macromolecular crystallography is to locate and directly visualize H atoms, it is important to address these issues, so that the deposited neutron models allow the retrieval of the maximum amount of information with the smallest effort of manual intervention. A path forward to improving the annotation, validation and deposition of neutron models and hybrid X-ray and neutron models is suggested.

59 BASIC BIOLOGICAL SCIENCES↗

Efficient loading of reduced data ensembles produced at ORNL SNS/HFIR neutron time-of-flight facilities

We present algorithmic improvements to the loading operations of certain reduced data ensembles produced from neutron scattering experiments at Oak Ridge National Laboratory (ORNL) facilities. Ensembles from multiple measurements are required to cover a wide range of the phase space of a sample material of interest. They are stored using the standard NeXus schema on individual HDF5 files. This makes it a scalability challenge, as the number of experiments stored increases in a single ensemble file. The present work follows up on our previous efforts on data management algorithms, to address identified input output (I/O) bottlenecks in Mantid, an open-source data analysis framework used across several neutron science facilities around the world. We reuse an in-memory binary-tree metadata index that resembles data access patterns, to provide a scalable search and extraction mechanism. In addition, several memory operations are refactored and optimized for the current common use cases, ranging most frequently from 10 to 180, and up to 360 separate measurement configurations. Results from this work show consistent speed ups in wall-clock time on the Mantid LoadMD routine, ranging from 19% to 23% on average, on ORNL production computing systems. The latter depends on the complexity of the targeted instrument-specific data and the system I/O and compute variability for the shared computational resources available to users of ORNL’s Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR) instruments. Nevertheless, we continue to highlight the need for more research to address reduction challenges as experimental data volumes, user time and processing costs increase.

Godoy, William↗

239 Pu(n,γ) from 10 eV to 1.3 MeV

In this study, the 239 Pu(n,γ) cross section has been measured from 10 eV to 1.3 MeV as part of an experimental campaign using the Detector for Advanced Neutron Capture Experiments (DANCE). The work represents a significant advance in experimental technique, with improved systematic uncertainties in key regions in the keV to MeV regime. In general the results of prior work are confirmed with improved uncertainties, particularly at the highest incident neutron energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The JSNS 2 detector

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for oscillations involving a sterile neutrino in the eV 2 mass-splitting range. The experiment will search for the appearance of electron antineutrinos oscillated from muon antineutrinos. The electron antineutrinos are detected via the inverse beta decay process using a liquid scintillator detector. A 1 MW beam of 3 GeV protons incident on a spallation neutron target produces an intense and pulsed neutrino source from pion, muon, and kaon decay at rest. The JSNS detector is located 24 m away from the neutrino source and began operation from June 2020. The detector contains 17 tonnes of gadolinium (Gd) loaded liquid scintillator (LS) in an acrylic vessel, as a neutrino target. It is surrounded by 31 tonnes of unloaded LS in a stainless steel tank. Optical photons produced in LS are viewed by 120 R7081 Hamamatsu 10-inch Photomultiplier Tubes (PMTs). In this study, we describe the JSNS detector design, construction, and operation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulations of neutron noise in the research reactor AKR-2: comparison between a discrete ordinates and a diffusion-based method

A diffusion-based and a discrete ordinates method are used to simulate a neutron noise experiment in the research reactor AKR-2 at the Technical University in Dresden, Germany. The AKR-2 reactor provides an interesting case for the comparison between the two methods because it is characterized by large heterogeneities and regions with low macroscopic neutron cross-sections. For the calculations, the same spatial discretization and the same set of two-energy macroscopic neutron cross-sections with isotropic scattering are used. Significant discrepancies between the diffusion-based and discrete ordinates methods are found in regions of the systems where the diffusion approximation is expected to be inaccurate in reproducing characteristics of the static neutron flux and neutron noise. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Detection of dynamical transitions in hydrogenous materials using transmission measurements with very cold neutrons

We have tested the transmission of very cold neutrons as a method to measure dynamical transitions in hydrogenous materials. Transmitted intensities vs. temperature at 30 A neutron wavelength were measured for four materials that undergo phase transformations associated with changes in dynamics: ammonium iodide, sodium borohydride, hexamethylbenzene, and dicesium dodecahydro-closo-dodecaborate. In some cases, neutron vibrational spectra above and below the transformation temperatures are compared to the transmission results. The measurements show changes in transmission at or near the transition for all these compounds, reflecting dynamical changes. The results demonstrate that the transmission method is sensitive to motional changes due to a wide range of structural transitions, from first-order to much more subtle order-disorder effects and for both small molecular species and larger molecules. The technique is valuable for rapid (ca. hours) scans of new materials to guide neutron inelastic scattering experiments or to complement the results of other techniques. - Graphical abstract: The transmission of very long wavelength neutrons is a highly sensitive probe of dynamical transitions in hydrogenous materials. Highlights: > Transmission of very long wavelength neutrons can probe dynamical transitions. > The technique is sensitive for both first-order and order-disorder transformations. > Changes in dynamical behavior of small and large molecular species can be detected. > This method can be a valuable guide for complex neutron scattering experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a thin scintillation films fission-fragment detector and a novel neutron source

Here, investigation of prompt fission and neutron-capture Υ rays from fissile actinide samples at the Detector for Advanced Neutron Capture Experiments (DANCE) requires use of a fission-fragment detector to provide a trigger or a veto signal. A fission-fragment detector based on thin scintillating films and silicon photomultipliers has been built to serve as a trigger/veto detector in neutron-induced fission measurements at DANCE. The fissile material is surrounded by scintillating films providing a 4π detection of the fission fragments. The scintillations were registered with silicon photomultipliers. A measurement of the 235 U(n,f) reaction with this detector at DANCE revealed a correct time-of-flight spectrum and provided an estimate for the efficiency of the prototype detector of 11.6(7)%. Design and test measurements with the detector are described. A neutron source with fast timing has been built to help with detector-response measurements. The source is based on the neutron emission from the spontaneous fission of 252 Cf and the same type of scintillating films and silicon photomultipliers. Overall time resolution of the source is 0.3 ns. Design of the source and test measurements with it are described. An example application of the source for determining the neutron/gamma pulse-shape discrimination by a stilbene crystal is given.

42 ENGINEERING↗

High-Energy Neutron Backgrounds for Underground Dark Matter Experiments

Direct dark matter detection experiments usually have excellent capability to distinguish nuclear recoils, expected interactions with Weakly Interacting Massive Particle (WIMP) dark matter, and electronic recoils, so that they can efficiently reject background events such as gamma-rays and charged particles. However, both WIMPs and neutrons can induce nuclear recoils. Neutrons are then the most crucial background for direct dark matter detection. It is important to understand and account for all sources of neutron backgrounds when claiming a discovery of dark matter detection or reporting limits on the WIMP-nucleon cross section. One type of neutron background that is not well understood is the cosmogenic neutrons from muons interacting with the underground cavern rock and materials surrounding a dark matter detector. The Neutron Multiplicity Meter (NMM) is a water Cherenkov detector capable of measuring the cosmogenic neutron flux at the Soudan Underground Laboratory, which has an overburden of 2090 meters water equivalent. The NMM consists of two 2.2-tonne gadolinium-doped water tanks situated atop a 20-tonne lead target. It detects a high-energy (>~ 50 MeV) neutron via moderation and capture of the multiple secondary neutrons released when the former interacts in the lead target. The multiplicity of secondary neutrons for the high-energy neutron provides a benchmark for comparison to the current Monte Carlo predictions. Combining with the Monte Carlo simulation, the muon-induced high-energy neutron flux above 50 MeV is measured to be (1.3 ± 0.2) ~ 10-9 cm-2s-1, in reasonable agreement with the model prediction. The measured multiplicity spectrum agrees well with that of Monte Carlo simulation for multiplicity below 10, but shows an excess of approximately a factor of three over Monte Carlo prediction for multiplicities ~ 10 - 20. In an effort to reduce neutron backgrounds for the dark matter experiment SuperCDMS SNO- LAB, an active neutron veto was developed. It is estimated that the current design of the neutron veto with a 40 cm thick layer of boron-doped liquid scintillator can achieve a > 90% efficiency for tagging the single-scatter neutrons. In addition, a one-quarter scale prototype detector for neutron veto has been built and tested.

79 ASTRONOMY AND ASTROPHYSICS↗

Strong quantum fluctuations in a quantum spin liquid candidate with a Co-based triangular lattice

Currently under active study in condensed matter physics, both theoretically and experimentally, are quantum spin liquid (QSL) states, in which no long-range magnetic ordering appears at low temperatures due to strong quantum fluctuations of the magnetic moments. The existing QSL candidates all have their intrinsic disadvantages, however, and solid evidence for quantum fluctuations is scarce. In this paper, we report a previously unreported compound, N a 2 B a C o ( P O 4 ) 2 , a geometrically frustrated system with effective spin-1/2 local moments for Co 2+ ions on an isotropic 2-dimensional (2D) triangular lattice. Magnetic susceptibility and neutron scattering experiments show no magnetic ordering down to 0.05 K. Thermodynamic measurements show that there is a tremendous amount of magnetic entropy present below 1 K in 0-applied magnetic field. The presence of localized low-energy spin fluctuations is revealed by inelastic neutron measurements. At low applied fields, these spin excitations are confined to low energy and contribute to the anomalously large specific heat. In larger applied fields, the system reverts to normal behavior as evident by both neutron and thermodynamic results. Our experimental characterization thus reveals that this material is an excellent candidate for the experimental realization of a QSL state.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Report to NCSP on 2008 DANCE measurements of 233 U($\eta$,$\gamma$)

Uranium-233 plays an important role in the Th-U fuel cycle, with substantial production in the cycle. This cycle has been proposed as an alternative to the U-Pu fuel cycle due to its reduced production of transuranic elements. An accurate measurement of the 233 U($\eta$,$\gamma$) cross section is required by the National Criticality Safety Program (NCSP) to complete the neutron-induced cross section data, where experimental capture cross section data are scarce and were measured decades ago. The most recent capture cross section data available in the literature were measured in 2007 at the n_TOF facility (CERN); in the 60s measurements were performed at Rensselaer Polytechnic Institute (RPI) and at LANL. Finally, as reported by ORNL, a new evaluation with a revised (renormalized) fission cross section is needed on 233 U. The challenge for this measurement lies in the difficulty of measuring the capture cross section data in the competing fission background, as the fission cross section is around one order of magnitude larger than the capture cross section for 233 U. The accuracy of a capture cross section measurement depends on discrimination between $\gamma$’s produced in capture and fission reactions, for which an experimental setup combining capture and fission detectors is needed. For the ($\eta$,$\gamma$) cross section measurement at LANSCE, this discrimination is achieved by combining the Detector for Advanced Neutron Capture Experiments (DANCE), to measure $\gamma$’s from capture reactions, with a Parallel Plate Avalanche Counter (PPAC) to tag the $\gamma$’s produced by fission. This method was successfully used to measure 235 U and 239 Pu capture cross sections. In these measurements, the neutron capture cross section was determined in a large fission background well above 100 keV. As part of the NCSP nuclear data effort, we have looked at past DANCE measurements on 233 U($\eta$,$\gamma$) and evaluated whether existing data is adequate to apply this technique.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Weak-coupling theory of neutron scattering as a probe of altermagnetism

Inelastic neutron scattering provides a powerful probe of the magnetic excitations of quantum magnets. Altermagnets have recently emerged as a new class of magnets with vanishing net magnetization characteristic of antiferromagnets and with a spin-split electronic structure typical of ferromagnets. Here we introduce a minimal Hubbard model with two-sublattice orthorhombic anisotropy as a framework to study altermagnetism. Using unrestricted Hartree-Fock calculations, we find an altermagnetic state for this model that evolves from a metallic state to an insulating state with increasing Hubbard-U Coulomb repulsion. We then examine the inelastic neutron scattering response in these states using random-phase approximation calculations of the dynamic spin susceptibility χ"(q,ω). We find that the magnetic excitation spectrum depends on its chirality for q along certain directions in reciprocal space, an observation that may be used in inelastic neutron scattering experiments as a probe of altermagnetism.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Proteins, fluctuations and complexity

Glasses, supercooled liquids, and proteins share common properties, in particular the existence of two different types of fluctuations, {alpha} and {beta}. While the effect of the {alpha} fluctuations on proteins has been known for a few years, the effect of {beta} fluctuations has not been understood. By comparing neutron scattering data on the protein myoglobin with the {beta} fluctuations in the hydration shell measured by dielectric spectroscopy we show that the internal protein motions are slaved to these fluctuations. We also show that there is no 'dynamic transition' in proteins near 200 K. The rapid increase in the mean square displacement with temperature in many neutron scattering experiments is quantitatively predicted by the {beta} fluctuations in the hydration shell.

59 BASIC BIOLOGICAL SCIENCES↗

Equation of state and strain-induced stabilization of δ-phase stabilized plutonium alloys

An in-situ high-pressure neutron diffraction experiment was conducted on a δ-phase stabilized plutonium alloy with isotope 242 Pu. Upon room-temperature compression, neither of the previously reported pressure-induced transformation paths, δ → α' or δ → γ’ → α', was observed up to 1.2 GPa. Instead, a drastic reduction in the diffraction intensity of the δ phase was observed when the pressure was above 0.8 GPa. At the highest pressure of the experiment (1.2 GPa), the diffraction data appear to be characteristic of an amorphous state, manifested by the diminishing intensities of all diffraction lines. Additionally, no evidence was found to support the transformation to a body-centered tetragonal structure (δ’), which was previously inferred from the diffraction line broadening during initial compression to 0.1 GPa. The discrepancies between the present and previous experiments suggest a substantial strain-induced stabilization of the δ-phase and is presumably attributed to the different stress states in the high-pressure environments. From the pressure - volume measurements, the determined isothermal bulk modulus for the δ-phase is in the range of 31.9 ± 1.3–34.8 ± 1.8 GPa using different pressure scales, comparable to those obtained from the resonant ultrasound spectroscopy measurements of the alloys of similar composition. Finally, the pressure-induced elastic softening is neither convinced in the present work, nor can it be resolved from the diffraction experiments if it is intrinsically weak.

36 MATERIALS SCIENCE↗

Atomistic Simulation of Nafion Membrane: 2. Dynamics of Water Molecules and Hydronium Ions

We have performed a detailed and comprehensive analysis of the dynamics of water molecules and hydronium ions in hydrated Nafion using classical molecular dynamics simulations with the DREIDING force field. In addition to calculating diffusion coefficients as a function of hydration level, we have also determined mean residence time of H2O molecules and H3O+ ions in the first solvation shell of SO3- groups. The diffusion coefficient of H2O molecules increases with increasing hydration level and is in good agreement with experiment. The mean residence time of H2O molecules decreases with increasing membrane hydration from 1 ns at a low hydration level to 75 ps at the highest hydration level studied. These dynamical changes are related to the changes in membrane nanostructure reported in the first part of this work. Our results provide insights into slow proton dynamics observed in neutron scattering experiments and are consistent with the Gebel model of Nafion structure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Benchmarking GEANT4 and PHITS for 14.8-MeV neutron transport in polyethylene and graphite materials

The feasibility of GEANT4 and PHITS with ENDF/B-VIII.0, JEFF-3.3 and JENDL-4.0 evaluated nuclear data libraries in 14.8-MeV neutron transport simulation are verified by comparing with the MCNP calculations and the experimental data. Here the measured data are from neutron integral experiments including graphite and polyethylene samples. For 6 cm-thick polyethylene and 20 cm-thick graphite samples, the results from GEANT4 and PHITS with three evaluated nuclear data libraries agree well with the MCNP calculations. For a 2 cm-thick graphite sample, the simulated results from GEANT4 and PHITS agree with the MCNP calculations, and they all underestimate the experiment data in below 3 MeV and overestimate them in the energy range of 5–7 MeV. The difference between the simulation results and the experimental data depends on the evaluated nuclear data libraries. In overall, GEANT4 and PHITS are performing reasonable jobs for 14.8-MeV neutron transport simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗