Search NASA⌕ Search

SEARCH · Search NASA

Results for “PATHOLOGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Impact of Endografting on the Thoracic Aortic Anatomy: Comparative Analysis of the Aortic Geometry before and after the Endograft Implantation

Purpose: Although the widespread acceptance of thoracic endovascular aortic repair (TEVAR) as a first-line treatment option for a multitude of thoracic aortic diseases, little is known about the consequences of the device implantation on the native aortic anatomy. We propose a comparative analysis of the pre- and postoperative geometry on a clinical series of patients and discuss the potential clinical implications Methods: CT pre- and postoperative acquisitions of 30 consecutive patients treated by TEVAR for different pathologies (20 thoracic aortic aneurysms, 6 false aneurysms, 3 penetrating ulcers, 1 traumatic rupture) were used to model the vascular geometry. Pre- and postoperative geometries were compared for each patient by pairing and matching the 3D models. An implantation site was identified, and focal differences were detected and described. Results: Segmentation of the data sets was successfully performed for all 30 subjects. Geometry differences between the pre- and postoperative meshes were depicted in 23 patients (76 %). Modifications at the upper implantation site were detected in 14 patients (47 %), and among them, the implantation site involved the arch (Z0–3) in 11 (78 %). Conclusion: Modeling the vascular geometry on the basis of imaging data offers an effective tool to perform patient-specific analysis of the vascular geometry before and after the treatment. Future studies will evaluate the consequences of these changes on the aortic function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is a Swine Model of Arteriovenous Malformation Suitable for Human Extracranial Arteriovenous Malformation? A Preliminary Study

Objective: A chronic arteriovenous malformation (AVM) model using the swine retia mirabilia (RMB) was developed and compared with the human extracranial AVM (EAVM) both in hemodynamics and pathology, to see if this brain AVM model can be used as an EAVM model. Methods: We created an arteriovenous fistula between the common carotid artery and the external jugular vein in eight animals by using end-to-end anastomosis. All animals were sacrificed 1 month after surgery, and the bilateral retia were obtained at autopsy and performed hematoxylin and eosin staining and immunohistochemistry. Pre- and postsurgical hemodynamic evaluations also were conducted. Then, the blood flow and histological changes of the animal model were compared with human EAVM. Results: The angiography after operation showed that the blood flow, like human EAVM, flowed from the feeding artery, via the nidus, drained to the draining vein. Microscopic examination showed dilated lumina and disrupted internal elastic lamina in both RMB of model and nidus of human EAVM, but the thickness of vessel wall had significant difference. Immunohistochemical reactivity for smooth muscle actin, angiopoietin 1, and angiopoietin 2 were similar in chronic model nidus microvessels and human EAVM, whereas vascular endothelial growth factor was significant difference between human EAVM and RMB of model. Conclusions: The AVM model described here is similar to human EAVM in hemodynamics and immunohistochemical features, but there are still some differences in anatomy and pathogenetic mechanism. Further study is needed to evaluate the applicability and efficacy of this model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Aortic Aneurysm Repair with Chimney and Snorkel Grafts: Indications, Techniques and Results

The chimney technique in endovascular aortic aneurysm repair (Ch-EVAR) involves placement of a stent or stent-graft parallel to the main aortic stent-graft to extend the proximal or distal sealing zone while maintaining side branch patency. Ch-EVAR can facilitate endovascular repair of juxtarenal and aortic arch pathology using available standard aortic stent-grafts, therefore, eliminating the manufacturing delays required for customised fenestrated and branched stent-grafts. Several case series have demonstrated the feasibility of Ch-EVAR both in acute and elective cases with good early results. This review discusses indications, technique, and the current available clinical data on Ch-EVAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transarterial Chemoembolization for Hepatocellular Carcinoma with a New Generation of Beads: Clinical–Radiological Outcomes and Safety Profile

PurposeTo evaluate the short-term safety and efficacy of the new generation of 70–150 µm drug-eluting beads (M1 DEB) in patients with hepatocellular carcinoma undergoing transarterial chemoembolization (TACE) as a primary therapy or as a bridge to liver transplantation (LT).MethodsForty-five consecutive patients underwent TACE with M1 DEB loaded with doxorubicin (DEBDOX/M1). Clinical data were recorded at 12, 24, and 48 h, 7 and 30 days after treatment. Response was assessed by computed tomographic scan according to the modified response evaluation criteria in solid tumors criteria, and a second DEBDOX/M1 TACE was scheduled within 6 weeks in case of a noncomplete response.ResultsAll patients had well-compensated cirrhosis (97.7 % Child A, 44.4 % hepatitis C virus, median age 61 years). Twenty patients (44.4 %) had Barcelona Clinic for Liver Cancer class B disease; the median number of nodules and their sum of diameters were 2 (range 1–6) and 43 mm (range 10–190), respectively. The mean number of TACE procedures per patient was 1.4. Objective response rate (complete + partial response) was 77.7 % with a median time to best response of 3 months (95 % confidence interval 2–4). In 13 patients, DEBDOX/M1 TACE served as a bridge/downstaging to LT/surgery. Pathology showed that more than 90 % necrosis was achieved in 10 of 28 nodules. DEBDOX/M1 TACE was well tolerated, and the grade 3/4 adverse event rate was low (1 of 65 procedures).ConclusionDEBDOX/M1 TACE is an effective procedure with a favorable safety profile and promising results in terms of objective response rate, tumor downstaging, and necrosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility Study on MR-Guided High-Intensity Focused Ultrasound Ablation of Sciatic Nerve in a Swine Model: Preliminary Results

IntroductionSpastic patients often seek neurolysis, the permanent destruction of the sciatic nerve, for better pain management. MRI-guided high-intensity focused ultrasound (MRgHIFU) may serve as a noninvasive alternative to the prevailing, more intrusive techniques. This in vivo acute study is aimed at performing sciatic nerve neurolysis using a clinical MRgHIFU system.MethodsThe HIFU ablation of sciatic nerves was performed in swine (n = 5) using a HIFU system integrated with a 3 T MRI scanner. Acute lesions were confirmed using T1-weighted contrast-enhanced (CE) MRI and histopathology using hematoxylin and eosin staining. The animals were euthanized immediately following post-ablation imaging.ResultsReddening and mild thickening of the nerve and pallor of the adjacent muscle were seen in all animals. The HIFU-treated sections of the nerves displayed nuclear pyknosis of Schwann cells, vascular hyperemia, perineural edema, hyalinization of the collagenous stroma of the nerve, myelin sheet swelling, and loss of axons. Ablations were visible on CE MRI. Non-perfused volume of the lesions (5.8–64.6 cc) linearly correlated with estimated lethal thermal dose volume (4.7–34.2 cc). Skin burn adjacent to the largest ablated zone was observed in the first animal. Bilateral treatment time ranged from 55 to 138 min, and preparation time required 2 h on average.ConclusionThe acute pilot study in swine demonstrated the feasibility of a noninvasive neurolysis of the sciatic nerve using a clinical MRgHIFU system. Results revealed that acute HIFU nerve lesions were detectable on CE MRI, gross pathology, and histology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fluoroscopy-Guided Percutaneous Vertebral Body Biopsy Using a Novel Drill-Powered Device: Technical Case Series

BackgroundA novel coaxial biopsy system powered by a handheld drill has recently been introduced for percutaneous bone biopsy. This technical note describes our initial experience performing fluoroscopy-guided vertebral body biopsies with this system, compares the yield of drill-assisted biopsy specimens with those obtained using a manual technique, and assesses the histologic adequacy of specimens obtained with drill assistance.MethodsMedical records of all single-level, fluoroscopy-guided vertebral body biopsies were reviewed. Procedural complications were documented according to the Society of Interventional Radiology classification. The total length of bone core obtained from drill-assisted biopsies was compared with that of matched manual biopsies. Pathology reports were reviewed to determine the histologic adequacy of specimens obtained with drill assistance.ResultsTwenty eight drill-assisted percutaneous vertebral body biopsies met study inclusion criteria. No acute complications were reported. Of the 86 % (24/28) of patients with clinical follow-up, no delayed complications were reported (median follow-up, 28 weeks; range 5–115 weeks). The median total length of bone core obtained from drill-assisted biopsies was 28 mm (range 8–120 mm). This was longer than that obtained from manual biopsies (median, 20 mm; range 5–45 mm; P = 0.03). Crush artifact was present in 11 % (3/28) of drill-assisted biopsy specimens, which in one case (3.6 %; 1/28) precluded definitive diagnosis.ConclusionsA drill-assisted, coaxial biopsy system can be used to safely obtain vertebral body core specimens under fluoroscopic guidance. The higher bone core yield obtained with drill assistance may be offset by the presence of crush artifact.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MRI-Guided Percutaneous Biopsy of Mediastinal Masses Using a Large Bore Magnet: Technical Feasibility

ObjectiveTo evaluate the diagnostic accuracy and safety of magnetic resonance imaging (MRI)-guided percutaneous biopsy of mediastinal masses performed using a wide-bore high-field scanner.Materials and MethodsThis is a retrospective study of 16 consecutive patients (8 male, 8 female; mean age 74 years) who underwent MRI-guided core needle biopsy of a mediastinal mass between February 2010 and January 2014. Size and location of lesion, approach taken, time for needle placement, overall duration of procedure, and post-procedural complications were evaluated. Technical success rates and correlation with surgical pathology (where available) were assessed.ResultsTarget lesions were located in the anterior (n = 13), middle (n = 2), and posterior mediastinum (n = 1), respectively. Mean size was 7.2 cm (range 3.6–11 cm). Average time for needle placement was 9.4 min (range 3–18 min); average duration of entire procedure was 42 min (range 27–62 min). 2–5 core samples were obtained from each lesion (mean 2.6). Technical success rate was 100 %, with specimens successfully obtained in all 16 patients. There were no immediate complications. Histopathology revealed malignancy in 12 cases (4 of which were surgically confirmed), benign lesions in 3 cases (1 of which was false negative following surgical resection), and one inconclusive specimen (treated as inaccurate since repeat CT-guided biopsy demonstrated thymic hyperplasia). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy in our study were 92.3, 100, 100, 66.7, and 87.5 %, respectively.ConclusionMRI-guided mediastinal biopsy is a safe procedure with high diagnostic accuracy, which may offer a non-ionizing alternative to CT guidance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Successful Management of Neobladder Variceal Bleeding

Hematuria from a neobladder can occur due to a variety of pathologies including tumors, stones, and fistulas. Variceal bleeding in a neobladder is a very rare condition with only one case reported in literature. We present a case of a patient with cirrhosis and portal hypertension and an ileocolic orthotopic neobladder presenting with hematuria. Computed tomographic angiography showed dilated varices around the neobladder which were successfully embolized. To the best of our knowledge, this is the first report case of variceal bleeding in a neobladder successfully managed with the combination of TIPS (transjugular intrahepatic portosystemic shunt) procedure and embolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intravascular Papillary Endothelial Hyperplasia (Masson’s Tumor) of the Radial Artery: A Case Report

Intravascular papillary endothelial hyperplasia (IPEH), often referred to as Masson’s tumor, is a benign non-neoplastic vascular lesion of the skin and subcutaneous tissues. Although it is rare, knowledge of the existence of IPEH is important as it can mimic other benign and malignant tumors, most notably angiosarcoma. IPEH remains an incompletely understood entity; however, most consider it to be the result of reactive endothelial proliferation following thrombus formation within a vessel, vascular malformation, or adjacent to a vessel. In this article, we report a case of IPEH arising within an arteriovenous malformation of the radial artery and present accompanying multimodality imaging and pathology figures. We will also describe the clinical presentation, pathophysiology, histology, imaging features, and management of IPEH.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MRI-guided Wire Localization Surgical Biopsy in an Adolescent Patient with a Difficult to Diagnose Case of Lymphoma

A 17-year-old previously healthy female presented with a progressive soft tissue infiltrative process involving the neck and thorax. Extensive diagnostic evaluation including multiple imaging, laboratory, and biopsy studies was nondiagnostic. Due to an urgent need to establish a diagnosis and several previous nondiagnostic biopsies, she was referred to interventional radiology for MRI-guided wire localization immediately prior to open surgical biopsy. Under general anesthesia, wires were placed in the areas of increased T2 signal within the bilateral splenius capitis muscles using intermittent MRI-guidance followed by immediate surgical biopsy down to the wires. Pathology confirmed the diagnosis of diffuse large B-cell lymphoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate Artery Embolization for Complete Urinary Outflow Obstruction Due to Benign Prostatic Hypertrophy

BackgroundWe aimed to evaluate the effectiveness of PAE in weaning of catheter and relieving obstructive urinary symptoms in patients with acute urinary retention (AUR) due to benign prostatic hypertrophy (BPH) and failed trial without catheter (TWOC).Materials and MethodsIn this prospective study approved by the institutional review board, a signed informed consent was obtained. Eighteen consecutive patients with AUR due to BPH and failed TWOC were recruited. Nineteen consecutive patients with BPH but without AUR were recruited as a control. Patients with CTA evidence of arterial occlusion or significant stenosis along the prostate artery access path were excluded. PAE was performed using microspheres (100–300 μm diameter). Outcome assessment included successful weaning of catheter in 2 weeks, procedure-related complications, change of symptomatology and urodynamic findings at 1 month as compared to baseline, percent non-perfused prostate volume, and prostate volume reduction on MRI at 2 weeks.ResultsTwo patients in the study group and four in the control group were excluded due to arterial pathology. Embolization of bilateral prostate arteries was achieved in all patients in both the groups (100%). There was no complication. The catheter was successfully weaned in 87.5% (14/16) of patients within 14 days in the treatment group. There was no significant difference in patient demographics, prostate characteristics, and all outcome assessment parameters between both the groups.ConclusionsPAE was probably safe and effective in weaning of catheter and relieving obstructive urinary symptoms in patients due to BPH, with treatment outcomes comparable to those without AUR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chitosan–Sodium Tetradecyl Sulfate Hydrogel: Characterization and Preclinical Evaluation of a Novel Sclerosing Embolizing Agent for the Treatment of Endoleaks

PurposeTo compare the efficacy of an embolization agent with sclerosing properties (made of chitosan and sodium tetradecyl sulfate, CH–STS) with a similar embolization agent but without sclerosing properties (made of chitosan, CH) in treating endoleaks in a canine endovascular aneurysm repair model.MethodsTwo chitosan-based radiopaque hydrogels were prepared, one with STS and one without STS. Their rheological, injectability, and embolizing properties were assessed in vitro; afterwards, their efficacy in occluding endoleaks was compared in a canine bilateral aneurysm model reproducing type I endoleaks (n = 9 each). The primary endpoint was endoleak persistence at 3 or 6 months, assessed on a CT scan and macroscopic examination. Secondary endpoints were the occurrence of stent-graft (SG) thrombosis, the evolution of the aneurysm mean diameter, as well as aneurysm healing and inflammation scores in pathology examinations.ResultsIn vitro experiments showed that both products gelled rapidly and presented initial storage moduli greater than 800 Pa, which increased with time. Both gels were compatible with microcatheter injection and occlude flow up to physiological pressure in vitro. In a type I endoleak model, the injection of CH–STS sclerosing gel tended to reduce the risk of occurrence of endoleaks, compared to CH non-sclerosing agent (2/9 vs. 6/9, p = 0.069). No case of SG thrombosis was observed. Moderate inflammation was found around both gels, with a comparable intensity score in both CH and CH–STS groups (2.6 ± 0.9 and 2.7 ± 0.9, respectively; p = 0.789).ConclusionsFlow occlusion combined with chemical endothelial denudation appears promising for the treatment of endoleaks.Level of EvidenceN/A.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Understanding the Lung Abscess Microbiome: Outcomes of Percutaneous Lung Parenchymal Abscess Drainage with Microbiologic Correlation

IntroductionLung parenchymal abscesses represent an uncommon pathology with high mortality if untreated. Although most respond well to antibiotics, the optimal therapy for persistent abscesses is unknown. The purpose of this study was to review the outcomes of percutaneous lung parenchymal abscess catheter drainage after broad-spectrum antibiotic therapy failure and correlate with patient microbiologic samples.Materials and MethodsRetrospective review of patients who underwent percutaneous lung abscess drainage at a tertiary hospital system from 2005 to 2015 was performed. In total, 19 procedures were identified on 16 different patients; six females and ten males. Mean patient age was 55 years (range 22–81). Median follow-up time was 7 months (range <1–78).ResultsTechnical success was 100%. There was one major complication, a pneumothorax. Follow-up was until tube removal or death in 100% of patients. Catheters were removed with resolution of the abscess cavity in 58% (11/19) or with non-draining abscess cavities in 21% (4/19) for a clinical success rate of 79%. Blood cultures demonstrated no growth in all cases, while 21% (4/19) of sputum or bronchoscopic cultures demonstrated growth. In comparison, the specimens from initial catheter placement isolated a causative organism in 95% (18/19) of case (p < 0.0001).ConclusionIn cases of persistent lung abscess after broad-spectrum antibiotics, percutaneous abscess drainage is highly sensitive for microbiologic sampling compared to sputum/bronchoscopic or blood cultures. Additionally, percutaneous drainage of lung parenchymal abscess cavities may promote resolution of the abscess with high rates of therapeutic success and low complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

End-hole Versus Microvalve Infusion Catheters in Patients Undergoing Drug-Eluting Microspheres-TACE for Solitary Hepatocellular Carcinoma Tumors: A Retrospective Analysis

Introduction: Pre-transplant locoregional therapy for hepatocellular carcinoma (HCC) during bridge-to-transplant impacts recurrence and survival rates following liver transplantation. Optimizing the effectiveness of transarterial chemoembolization (TACE) in this population is imperative, and microvalve infusion catheters offer a means of such improvement. Methods: All treatment-naive patients with solitary HCC tumors < 6.5 cm who underwent drug-eluting microspheres (DEM) TACE between 04/2015 and 08/2017 were retrospectively reviewed. Eighty-eight included patients underwent DEM-TACE with either standard end-hole catheters (EH) or microvalve infusion catheters (MVI). The EH (n = 70) and MVI (n = 18) cohorts had similar baseline tumor size, laboratory values, and tumor etiologies. Results: Initial objective response rates were significantly higher in MVI vs. EH (100% vs. 76.5%, p = 0.019). There was no difference in adverse events between groups (p = 0.265). MVI patients exhibited lower AST (p = 0.003) and ALT (p = 0.044) at 6 months. Blinded pathological analysis of explanted livers showed greater concentrations of microspheres within the tumor relative to the surrounding tissue in MVI explants (88.7 ± 10.6%) versus the EH explants (55.3 ± 32.7%) (p = 0.002). There was significantly higher percentage tumor necrosis in the MVI group (89.0 ± 2.2%) compared with the EH group (56.1 ± 44.5%) (p = 0.006). Conclusion: In this retrospective study of a single-center cohort, DEM-TACE procedures with MVI were associated with improved tumor response, increased deposition of microspheres within tumor tissue, and higher percentage tumor necrosis at explant relative to those performed using EH catheters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Outcome of the Visible Coil During Endoscopy After Transcatheter Arterial Embolization for Gastrointestinal Bleeding

Purpose: This study was designed to evaluate the clinical outcome of the visible coil during endoscopy after transcatheter arterial embolization (TAE) for gastrointestinal bleeding. Methods: We retrospectively reviewed the medical records of 1415 patients who underwent TAE for gastrointestinal bleeding between 2001 and 2017. Among these 1415 patients, 70 underwent TAE using coils and consecutive follow-up endoscopy. Finally, 11 patients with an extravascular coil seen on follow-up endoscopic examination were included in this study. We evaluated the underlying cause of the gastrointestinal bleeding, the technical and clinical success rates, the type of extravascular coil after TAE, and the clinical outcomes of the extravascular coil seen on follow-up endoscopic examination. Results: Of the 11 patients, the most common underlying cause of gastrointestinal bleeding was a duodenal ulcer (n = 7). On angiography, the bleeding artery was most commonly found in the gastroduodenal artery (n = 6). The technical success and clinical success rates of TAE were 100% and 90.9%, respectively. The type of extravascular coil found on endoscopic examination was classified by submucosal migration (n = 6) and protrusion (n = 5). On second-look endoscopic evaluation, 10 of 11 (90.9%) patients showed healing ulceration. On the final-look endoscopic evaluation, healing ulceration without further bleeding was seen in one (9.1%) patient and scar formation was seen in ten (90.9%) patients. Conclusions: Extravascular coil after TAE for gastrointestinal bleeding is rare, and the most common underlying cause is duodenal ulcer bleeding. The extravascular coils eventually show a healing process with adequate treatment of underlying bowel pathologies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Does the cortical bone resorption rate change due to 90 Sr-radiation exposure? Analysis of data from Techa Riverside residents

The Mayak Production Association released large amounts of 90 Sr into the Techa River (Southern Urals, Russia) with peak amounts in 1950-1951. Techa Riverside residents ingested an average of about 3,000 kBq of 90 Sr. The 90 Sr-body burden of approximately 15,000 individuals has been measured in the Urals Research Center for Radiation Medicine in 1974-1997 with use of a special whole-body counter (WBC). Strontium-90 had mainly deposited in the cortical part of the skeleton by 25 years following intake, and 90 Sr elimination occurs as a result of cortical bone resorption. The effect of 90 Sr-radiation exposure on the rate of cortical bone resorption was studied. Data on 2,022 WBC measurements were selected for 207 adult persons, who were measured three or more times before they were 50-55 years old. The individual-resorption rates were calculated with the rate of strontium recirculation evaluated as 0.0018 year -1 . Individual absorbed doses in red bone marrow (RBM) and bone surface (BS) were also calculated. Statistically significant negative relationships of cortical bone resorption rate were discovered related to 90 Sr-body burden and dose absorbed in the RBM or the BS. The response appears to have a threshold of about 1.5-Gy RBM dose. The radiation induced decrease in bone resorption rate may not be significant in terms of health. However, a decrease in bone remodeling rate can be among several causes of an increased level of degenerative dystrophic bone pathology in exposed persons.

59 BASIC BIOLOGICAL SCIENCES↗

Radiology and Enterprise Medical Imaging Extensions (REMIX)

Radiology and Enterprise Medical Imaging Extensions (REMIX) is a platform originally designed to both support the medical imaging-driven clinical and clinical research operational needs of Department of Radiology of The Ohio State University Wexner Medical Center. REMIX accommodates the storage and handling of “big imaging data,” as needed for large multi-disciplinary cancer-focused programs. The evolving REMIX platform contains an array of integrated tools/software packages for the following: (1) server and storage management; (2) image reconstruction; (3) digital pathology; (4) de-identification; (5) business intelligence; (6) texture analysis; and (7) artificial intelligence. These capabilities, along with documentation and guidance, explaining how to interact with a commercial system (e.g., PACS, EHR, commercial database) that currently exists in clinical environments, are to be made freely available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated Segmentation and Quantification of Drusen in Fundus and Optical Coherence Tomography Images for Detection of ARMD

Age-related macular degeneration (ARMD) is one of the most common retinal syndromes that occurs in elderly people. Different eye testing techniques such as fundus photography and optical coherence tomography (OCT) are used to clinically examine the ARMD-affected patients. Many researchers have worked on detecting ARMD from fundus images, few of them also worked on detecting ARMD from OCT images. However, there are only few systems that establish the correspondence between fundus and OCT images to give an accurate prediction of ARMD pathology. In this paper, we present fully automated decision support system that can automatically detect ARMD by establishing correspondence between OCT and fundus imagery. The proposed system also distinguishes between early, suspect and confirmed ARMD by correlating OCT B-scans with respective region of the fundus image. In first phase, proposed system uses different B-scan based features along with support vector machine (SVM) to detect the presence of drusens and classify it as ARMD or normal case. In case input OCT scan is classified as ARMD, region of interest from corresponding fundus image is considered for further evaluation. The analysis of fundus image is performed using contrast enhancement and adaptive thresholding to detect possible drusens from fundus image and proposed system finally classified it as early stage ARMD or advance stage ARMD. The proposed system is tested on local data set of 100 patients with100 fundus images and 6800 OCT B-scans. Proposed system detects ARMD with the accuracy, sensitivity, and specificity ratings of 98.0, 100, and 97.14%, respectively.

62 RADIOLOGY AND NUCLEAR MEDICINE↗