Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV CAPACITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

U.S. Renewable Energy Technical Potentials: A GIS-Based Analysis

This report presents the state-level results of a spatial analysis effort calculating energy technical potential, reported in square kilometers of available land, megawatts of capacity, and gigawatt-hours of generation, for six different renewable technologies. For this analysis, the system specific power density (or equivalent), efficiency (capacity factor), and land-use constraints were identified for each technology using independent research, published research, and professional contacts. This report also presents technical potential findings from previous reports.

09 BIOMASS FUELS↗

Optimal Capacitor Bank Capacity and Placement in Distribution Systems with High Distributed Solar Power Penetration

Capacitor banks have been generally installed and utilized to support distribution voltage during period of higher load or on longer, higher impedance, feeders. Installations of distributed energy resources in distribution systems are rapidly increasing, and many of these generation resources have variable and uncertain power output. These generators can significantly change the voltage profile across a feeder, and therefore when a new capacitor bank is needed analysis of optimal capacity and location of the capacitor bank is required. In this paper, we model a particular distribution system including essential equipment. An optimization method is adopted to determine the best capacity and location sets of the newly installed capacitor banks, in the presence of distributed solar power generation. Finally we analyze the optimal capacitor banks configuration through the optimization and simulation results.

14 SOLAR ENERGY↗

Net Zero Energy Model for Wastewater Treatment Plants

The primary objective of this study is to achieve net-zero energy (NZE) wastewater treatment plants (WWTPs) by utilizing energy efficiency opportunities (EEO), combined heat and power (CHP) systems, and other renewable energy (RE) sources, e.g., solar, water, and wind powers. Herein, this study discusses an innovative energy solution for WWTPs in the United States, and one of the WWTPs with a flow capacity of 1.5 million gallons per day (MGD) was selected as a case study. An optimization tool, Hybrid Optimization of Multiple Energy Resources (HOMER) software, is used in this study to find the best energy system configuration to run the system. An energy audit for one WWTP was conducted in early 2020 and the report is used to do this study. The proposed EEOs were able to reduce WWTP energy consumption by about 11%. The excess anaerobic digester gas was utilized in a CHP system to cover about 42% of the facility’s consumption. Also, 3% of the utility energy consumption can be claimed by microturbines in the aeration tanks. Another two renewable energy systems, solar photovoltaic (PV) with 29% and water turbines with 15%, contribute to covering 100% of the WWTP energy consumption and achieving an NZE WWTP.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Parallel derivative-free optimization for simulation-based design of behind-the-meter energy systems

In this work, the integrated design and dispatch of behind-the-meter or distributed resources (e.g. stationary battery storage and solar PV generation) is considered. A simulation-based framework is employed, generating high-fidelity results with closed-loop predictive control at a fine resolution, at the expense of high computational cost (several minutes to a few hours per design point). To address this challenge, parallel derivative-free design methods are considered. Four methods are compared, including state-of-the-art surrogate-based methods (Radial-Basis Functions and Gaussian processes) and sampling strategies, an evolutionary-based method, and a simple sequential grid refinement method. As a case study, two types of design problem with increasing complexity are considered, namely, the design of behind-the-meter resources (three design variables) and the inclusion of grid capacity (four design variables). The second yields a constrained design problem for which violations can only be determined after solving the computationally expensive simulation. For the three-dimensional case, all methods present a good performance, achieving a solution within 1% of the optimum after the first iteration, with the sequential grid refinement exhibiting the fastest convergence and achieving the best final objective value. This indicates that the parallel evaluation of multiple sampling points may be more important than the choice of method for small decision spaces. For the four-dimensional constrained case, the Genetic Algorithm presents the best tradeoff between performance and computational effort, while the rough objective function terrain generated by constraint violation penalties reduces the performance of surrogate-based methods. Contour plots with flat regions indicate flexibility in the optimal design and highlight the importance of characterizing the solution space.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessing Cost-Optimal Battery Energy and Solar-Plus-Storage Systems for Federal Customers: A Nationwide Assessment: Preprint

Prior research has identified that the financial viability of behind-the-meter battery energy storage systems is heavily dependent on technology cost, utility rate structure, energy consumption patterns, and co-deployment with synergistic technologies like solar photovoltaics (PV), among other factors. This study builds on existing research by comprehensively evaluating the economics of battery energy storage systems (BESS) and solar-plus-storage systems for a reference office building at 755 reference sites under 834 utility rates, and four storage capital cost scenarios. Results indicate that even with dramatic cost reductions, BESS is likely to be cost-effective only under utility rates that include demand charges, and possibly include time-of-use (TOU) pricing as well. Even under these utility rates, BESS systems provide marginal savings, and office building operators are unlikely to deploy the technology for cost savings alone. Solar-plus-storage systems provide more savings than BESS and allow for larger economic storage capacities. Solar-plus-storage provides compelling savings opportunities at baseline prices, and even at capital costs 25% higher than baseline. Solar-plus-storage is most effective where there are demand charges and energy pricing schemes include TOU pricing, or where electricity is expensive (at least $0.30/kWh). Our case studies illustrate that the presence of demand charges, even at similar energy costs, can be the deciding factor in BESS and solar-plus-storage viability. The findings and maps from this assessment may be of use to planners, building owners, and developers looking for potentially economic storage opportunities.

battery energy storage systems↗

EverGREEN 2045: An Energy Mix to Decarbonize Washington State

Washington State’s future resource mix is likely to be comprised of intermittent renewables and carbon-free generation including hydropower by 2045. Generation will likely be comprised of wind, solar photovoltaic (PV), batteries, pumped storage hydropower (PSH), existing nuclear power plants, and potentially enhanced geothermal systems and advanced nuclear reactor technologies. To assess the cost and stability of the future resource mix, we partner with X-energy (advanced reactor design) and AltaRock Energy (enhanced geothermal system) for proprietary cost data. After estimating the costs of these two new technologies, we design plausible future resource mix scenarios to meet Washington State’s Clean Energy Transformation Act which transitions the state to carbon-free generation by 2045. We assess the cost and stability of the future resource mix with power system analysis tools, finding revenues are sufficient to cover variable operating and maintenance costs for most technologies providing power in 2030 and 2045, but capacity payments or power purchase agreements will likely be necessary for flexible resources, including enhanced geothermal systems and advanced nuclear reactors, to participate in the future resource mix.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Community Planning for Solar: Defining Realistic Solar Development Options

This guide is designed to aid in assessing community preferences for solar development and financing alternatives. To evaluate community preferences regarding solar, it is necessary to define the range of realistic options for solar development possible in a community, including potential future targets for solar capacity, the mixes of development possible based on the solar resources available, and potential community benefits and solar ownership structures. This guide can help community officials, volunteers, and regional planning agency staff in constructing a realistic suite of options for solar development, based on existing state and local laws, available solar resources and infrastructure, and economic and financial considerations.

14 SOLAR ENERGY↗

Human Health Science Building Geothermal Heat Pump Systems

The grant objectives of the DOE grant funded project have been successfully completed. The Human Health Building (HHB) was constructed and opened for occupancy for the Fall 2012 semester of Oakland University. As with any large construction project, some issues arose which all were overcome to deliver the project on budget and on time. The facility design is a geothermal / solar-thermal hybrid building utilizing both desiccant dehumidification and variable refrigerant flow heat pumps. It is a cooling dominant building with a 400 ton cooling design day load, and 150 ton heating load on a design day. A 256 vertical borehole (320 ft depth) ground source heat pump array is located south of the building under the existing parking lot. The temperature swing and performance over 2013 through 2015 shows the ground loop is well sized, and may even have excess capacity for a future building to the north (planned lab facility). The HHB achieve a US Green Building Counsel LEED Platinum rating by collecting 52 of the total 69 available LEED points for the New Construction v.2 scoring checklist. Being Oakland's first geothermal project, we were very pleased with the building outcome and performance with the energy consumption approximately 1/2 of the campus average facility, on a square foot basis.

15 GEOTHERMAL ENERGY↗

Battery Reinitialization of the Photovoltaic Module of the International Space Station

The photovoltaic (PV) module on the International Space Station (ISS) has been operating since November 2000 and supporting electric power demands of the ISS and its crew of three. The PV module contains photovoltaic arrays that convert solar energy to electrical power and an integrated equipment assembly (IEA) that houses electrical hardware and batteries for electric power regulation and storage. Each PV module contains two independent power channels for fault tolerance. Each power channel contains three batteries in parallel to meet its performance requirements and for fault tolerance. Each battery consists of 76 Ni-Hydrogen (Ni-H2) cells in series. These 76 cells are contained in two orbital replaceable units (ORU) that are connected in series. On-orbit data are monitored and trended to ensure that all hardware is operating normally. Review of on-orbit data showed that while five batteries are operating very well, one is showing signs of mismatched ORUs. The cell pressure in the two ORUs differs by an amount that exceeds the recommended range. The reason for this abnormal behavior may be that the two ORUs have different use history. An assessment was performed and it was determined that capacity of this battery would be limited by the lower pressure ORU. Steps are being taken to reduce this pressure differential before battery capacity drops to the point of affecting its ability to meet performance requirements. As a first step, a battery reinitialization procedure was developed to reduce this pressure differential. The procedure was successfully carried out on-orbit and the pressure differential was reduced to the recommended range. This paper describes the battery performance and the consequences of mismatched ORUs that make a battery. The paper also describes the reinitialization procedure, how it was performed on orbit, and battery performance after the reinitialization. On-orbit data monitoring and trending is an ongoing activity and it will continue as ISS assembly progresses.

Hajela, Gyan↗

Winnebago Tribe Solar Project

The strategy of the Solar Project was to reduce fuel use within two years by a roof mounted photovoltaic system. The police/fire building is completely powered by electricity. The renewable energy system we have selected has a power capacity of 23kW and the ability to export 44.3 MWh. We anticipate 32.55% kWh energy savings, an excess of the required 30% reduction, in the building’s total fuel use based on the most current 12 months of data (2012). The solar electric system is a grid-tie, ballast mounted on a flat roof over the police/fire station. The solar electric system includes 280 Watt modules for a nominal total of 22.80 kW. Approximately 84 modules are ballast mounted to the flat roof facing south.

14 SOLAR ENERGY↗

On the impact of tidal generation and energy storage integration in PV-rich electric distribution systems

Deep decarbonization of power system operations requires the maximal utilization of available renewable resources. At distribution-level operations, however, grid operators can face numerous challenges in integrating renewables at scale owing to the inherent intermittence of renewable energy resources. These include phenomena such as voltage fluctuations, which are typically mitigated through control actuators such as on-load tap changers (OLTC) as well as energy storage devices, such as battery energy storage systems (BESS). On the one hand, high intermittence of the available renewable portfolio may require increasingly aggressive control of actuators, thereby accelerating the probability of equipment failure. On the other hand, integrating BESS operations and having a diverse renewable generation portfolio can typically help stagger power/energy flow to mitigate the aforementioned adverse impacts. In this paper, we employ a Bayesian framework for equipment lifetime estimation to understand the impact of including tidal energy resources and BESS in distribution system operations for feeders having substantial distribution photovoltaic generation. Our results indicate that while tidal energy alone may slightly decrease equipment reliability, the adverse impact on reliability is significantly magnified by a generation portfolio consisting of tidal generation and photovoltaic generation. Here, we also study the tidal and photovoltaic hosting capacity problem with and without energy storage systems using equipment reliability as an added constraint. We conclude that energy storage increases the reliability-constrained hosting capacity of the distribution system.

14 SOLAR ENERGY↗

Effect of power system technology and mission requirements on high altitude long endurance aircraft

An analysis was performed to determine how various power system components and mission requirements affect the sizing of a solar powered long endurance aircraft. The aircraft power system consists of photovoltaic cells and a regenerative fuel cell. Various characteristics of these components, such as PV cell type, PV cell mass, PV cell efficiency, fuel cell efficiency, and fuel cell specific mass, were varied to determine what effect they had on the aircraft sizing for a given mission. Mission parameters, such as time of year, flight altitude, flight latitude, and payload mass and power, were also altered to determine how mission constraints affect the aircraft sizing. An aircraft analysis method which determines the aircraft configuration, aspect ratio, wing area, and total mass, for maximum endurance or minimum required power based on the stated power system and mission parameters is presented. The results indicate that, for the power system, the greatest benefit can be gained by increasing the fuel cell specific energy. Mission requirements also substantially affect the aircraft size. By limiting the time of year the aircraft is required to fly at high northern or southern latitudes, a significant reduction in aircraft size or increase in payload capacity can be achieved.

Colozza, Anthony J.↗

Recent Photovoltaic Performance Data in the USA (Presentation)

This paper presents performance data from nearly 50,000 Photovoltaic systems totaling 1.7 Gigawatts installed capacity in the USA from 2009 to 2012. 90% of the systems performed to within 10% or better of expected performance. Only 2-4% of the data indicate issues significantly affecting the system performance. Special causes of underperformance and their impacts are delineated by reliability category. Delays and interconnections dominate project-related issues particularly in the first year, but total less than 0.5% of all systems. Hardware-related issues are dominated by inverter problems totaling less than 0.4% and underperforming modules to less than 0.1%.

14 SOLAR ENERGY↗

Streamlining Energy Sprawl: Assessment of Geothermal Impacts on Public Lands

Renewable energy power generation, including geothermal, solar photovoltaics (PV), and wind, can have significant land use impacts depending on the technology and the size of the facility. At the same time, innovations across these renewable technologies are working to improve plant efficiency per acre of disturbance. Through a survey of satellite imagery and other sources, this analysis reevaluates the impact of geothermal power generation and examines the variations in land use for different geothermal technologies (binary, flash, and dry steam). Geothermal operations on Bureau of Land Management (BLM) sites serve as the focus for this analysis - i.e., only active sites with federal mineral ownership for which the BLM receives royalties from power production. The results show significant variation in direct land disturbance across the operations sites and across these three geothermal technologies. Although there is variation across plants within the same geothermal technology category, dry steam plants (The Geysers) were shown to have the lowest impact, in acres per megawatt capacity and acres per gigawatt-hour generation, followed by flash steam and binary plants. Overall, direct land impacts relative to capacity and generation have declined 16-27% for facilities constructed since 2000 as compared to those constructed prior, even though most new facilities are binary plants (which traditionally had higher land disturbance). Additionally, capacity factors based on actual net production data were found to average only 50% across all operations sites, suggesting that previous estimates based on nameplate capacity only may lead to an undercounting of generation-based land disturbance metrics. Should the geothermal industry capture additional market share, improving land disturbance metrics through accurate net production and capacity data and further minimizing impacts will be increasingly important as competition over land use intensifies.

GEOTHERMAL ENERGY↗

Power Supply Options for the Marpi Landfill, Saipan: Feasibility Study

The Marpi Landfill, located on the northern end of the island of Saipan in the Commonwealth of the Northern Mariana Islands (CNMI), is powered by an on-site diesel generator that only operates when the landfill is open and staffed. The CNMI Office of Planning and Development (OPD) aspires to provide the Marpi Landfill with 24-hour power availability despite its remote location and to increase the use of sustainable energy within the CNMI. CNMI has a 20% target for renewable energy consumption, as documented in Sustainable Development Goal #7 in the Comprehensive Sustainable Development Plan (OPD 2021) and the renewable portfolio standard (GPO 2014). To accomplish these goals, the U.S. Department of Energy, through its Interagency Reimbursable Work Agreement with the Federal Emergency Management Agency, funded this feasibility study to assess and prioritize power supply options for the landfill. The availability of solar and wind resources varies seasonally, as does the load. A BESS can help to balance mismatches between generation and load on short (hourly or daily) timescales, but not across seasons. The microgrid scenarios evaluated for Marpi consider options for technology combinations that will both meet the load and utilize available resources, despite the challenge presented by higher loads and lower solar and wind availability during the rainy season, depicted in Figure ES-2. The seven scenarios evaluated are summarized in Table ES-1. Each scenario’s configuration was optimized to include component capacities that reduce capital and operating costs, meet the load, and minimize carbon emissions, as feasible. The costs and levelized cost of energy (LCOE) shown do not assume the use of any grant funding or incentives, although these options were also evaluated. To assist with decision-making, a prioritization matrix (Table ES-3) was created to compare the microgrid scenarios evaluated in this feasibility study according to various stakeholder priorities. The prioritization metrics were chosen based on discussions with OPD and will be finalized through stakeholder feedback. The scenarios were given a score between 1 and 7 for each prioritization metric (the lower the score, the higher the priority), and total scores were calculated using assigned weights based on the relative priority of each metric. The total scores were then ranked to produce a prioritized list of microgrid scenarios based on the metrics most important to the project stakeholders. As shown, scenario 4 (100 kW of solar PV, a 75 kW/300 kWh BESS, and 160 kW of diesel generation) ranks highest.

14 SOLAR ENERGY↗

Utility-Scale Photovoltaic Deployment Scenarios of the Western United States: Implications for Solar Energy Zones in Nevada

In this study, we use the National Renewable Energy Laboratory's (NREL's) Regional Energy Deployment System (ReEDS) capacity expansion model to estimate utility-scale photovoltaic (UPV) deployment trends from present day through 2030. The analysis seeks to inform the U.S. Bureau of Land Management's (BLM's) planning activities related to UPV development on federal lands in Nevada as part of the Resource Management Plan (RMP) revision for the Las Vegas and Pahrump field offices. These planning activities include assessing the demand for new or expanded additional Solar Energy Zones (SEZ), per the process outlined in BLM's Western Solar Plan process.

14 SOLAR ENERGY↗

The Evolving Solar Energy Innovation Ecosystem in Puerto Rico

This report presents initial findings from the research project, “Developing socially and economically generative, resilient PV-energy systems for low- and moderate-income communities: Applications for Puerto Rico.” This material is based upon work supported primarily by the US Department of Energy’s Office of Energy Efficiency and Renewable Energy under the Solar Energy Technology Office Fiscal Year 2018 Funding Program award number DE-EE0008570 and in part by the National Science Foundation (NSF) and the Department of Energy (DOE) under NSF CA No. EEC-1041895. This project is a joint effort of Arizona State University’s Center for Energy and Society; the University of Puerto Rico-Mayaguez’s Center for Hemispheric Cooperation in Research and Education in Engineering and Applied Science, Sustainable Energy Center, and National Institute for Energy and Island Sustainability; and the National Renewable Energy Laboratory. The project seeks to understand the place of energy in low-income communities in Puerto Rico, the opportunities for solar energy to provide solutions to the energy challenges facing these communities, and the capacity of the solar energy innovation ecosystem in Puerto Rico to deliver relevant solar solutions for these communities. We define the solar energy innovation ecosystem as the diverse actors and stakeholders whose collective networks and actions—and the flows among them of ideas, knowledge, data, influence, money, and equipment, as well as the rules that govern those flows—are essential to the success of renewable energy markets and projects. This report presents results from the first year of the project’s research, which has concentrated on several key goals: (1) characterizing the trajectory of solar energy development in Puerto Rico in the three years since Hurricane María; (2) mapping and characterizing the current solar energy innovation ecosystem in Puerto Rico, including the technical potential for solar energy in Puerto Rico, and the business and policy landscape shaping solar developments; and (3) beginning to characterize the broad landscape of community energy initiatives underway in Puerto Rico. To pursue these goals, we engaged in a systematic review of solar energy developments in Puerto Rico and conducted interviews with over 100 members of the solar energy innovation, including policy, business, finance, research, and civil society leaders, as well as solar users. Solar technical potential data for Puerto Rico was developed by the National Renewable Energy Laboratory (NREL) and is publicly available at: https://data.nrel.gov/submissions/144. The documentation for the NREL dataset is included as Appendix A.

14 SOLAR ENERGY↗

OPALCO - Decatur Island Solar and Energy Storage Project: An Assessment of Battery Technical Performance

Orcas Power & Light Cooperative (OPALCO) is a member-owned, nonprofit cooperative utility that provides energy services to approximately 11,200 customers across 20 islands in San Juan County, Washington. OPALCO’s mostly hydroelectric power is generated by Bonneville Power Administration and delivered to the islands by submarine cables. In 2016, as part of the second round of funding from the Washington state Clean Energy Fund, OPALCO received a $1 million matching grant to support a project that deployed a 504-kW LG community photovoltaic (PV) system in combination with a 1 MW/2 MWh lithium-iron-phosphate battery energy storage system (BESS) on Decatur Island, Washington. The Decatur Island Substation is essential to ensuring reliable energy for the residents of the San Juan Islands as it is the point of interconnection with the mainland transmission system. The BESS, in combination with the community solar array, will deliver an innovative method to both defer the costly upgrade of the transmission system and allow for other high-value applications intended to benefit the utility and its customers. In 2018, Pacific Northwest National Laboratory (PNNL) completed a preliminary economic assessment for several identified use cases in collaboration with OPALCO. Between August 2021 and May 2022, extensive testing was conducted, and the results were used to assess the technical performance of the BESS subjected to actual field operations. Both reference performance and use case tests were performed: (a) Reference performance tests assess the general technical capabilities of the BESS, such as energy capacity, round-trip efficiency (RTE), ramp rate, and signal tracking capability. These are the first tests performed (baseline) and are repeated after use case tests (post cycle). A standardized U.S. Department of Energy (DOE) energy storage performance protocol was used to characterize the BESS, including representative duty cycle profiles, test procedure guidance, and calculation guidance for determining key characteristics. (b) Use case tests examine the performance of the BESS for specific use cases using duty cycles developed by PNNL in collaboration with OPALCO. Four use cases were selected for testing: 1) demand charge reduction, 2) load shaping, 3) outage mitigation, and 4) transmission deferral. The use case duty cycles were developed based on utility and site-specific characteristics in addition to the technical characteristics and physical capabilities of the BESS. Use case tests were performed between the baseline and post cycle tests. This report describes the BESS and its components, presents testing and performance analysis results, and shares key insights and lessons learned from this project. Outcomes of the tests and analyses will help OPALCO understand the performance of the Decatur Island BESS in its current state and design appropriate operational strategies for this and other BESSs over the long term.

14 SOLAR ENERGY↗