At least 685 records · Page 38

Compact scalable nanofiber mass production using electrospinning

A low power out put high voltage power supply unit for mass producing thicker nanofiber mat has been built in-house and earned a provisional patent last year. This nanofiber fabrication unit has unique features to produce stand alone thick ceramic nanofiber for specialized application such as isotop production and accelerator targets for high energy physics experiments. This is a versatile unit which can produce wide variety of polymer nanofibers on a semi industrial scale for application in air filtration, face mask, facial beauty pads, gas sensors and many more.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Architectural Survey of the Pluto Test Bunker Facility, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), in conjunction with the National Nuclear Security Administration Nevada Field Office (NNSA/NFO), proposes to reactivate Building 26-2205 as part of a project to detect foundry-type operations with remote sensing. The project is known as the Signals Exploration Testbed, or SET for short. Building 26-2205 (State Historic Preservation Office [SHPO] Resource No. B11558) is the former Compressor Building for the Pluto Program in Area 26 of the Nevada National Security Site (NNSS). Proposed actions at Building 26-2205 include removal of exterior building and site features, such as fencing, concrete pads, a large steel tank, and visible utilities, as well as interior changes to the building’s floor plan. These activities constitute an undertaking subject to review under Section 106 of the National Historic Preservation Act (NHPA) (54 United States Code [USC] § 306101) and its implementing regulations, 36 Code of Federal Regulations (CFR) Part 800.

54 ENVIRONMENTAL SCIENCES↗

All-digital Sensor System for Distributed Downhole Pressure Monitoring in Unconventional Fields

This project developed and validated (through field tests) a new low-cost all-digital pressure sensing technology for in situ distributed downhole pressure monitoring in unconventional oil and gas (UOG) fields. The all-digital sensing technology uses a built-in non-electric analog-to-digital converter (ADC) to transform the pressure information into a combination of binary (ON/OFF) states. As such, the system does not need downhole electronics for signal conditioning and telemetry. The all-digital sensors can be remotely logged over a long distance, and many sensors can be multiplexed for distributed sensing. Based on a review of unconventional wells in the Lower 48 states, the specification of the sensor is to measure pressure up to 69 MPa (10,000 psi) and temperature up to 250°C. A sensor with a helical bourdon sensing element and a digital signal decoder of 50 mm diameter and 109 mm length was constructed. The helical bourdon sensing element was made of 304L stainless steel and filled with motor oil. The digital converter was made up of 8 digital reading pads constructed of high-temperature epoxy with conductive inserts made of stainless steel. The sensor had a linear response to pressure with an accuracy of 0.14 MPa (20 psi). To withstand the high pressure, the sensor was enclosed in a stainless-steel pressure housing with a wall thickness of 5.5 mm, a diameter of 73 mm, and a length of 724 mm. In the laboratory tests, the sensor exhibited no temperature-related effects on the results. The sensor did not show drift over a 14-day test period at elevated pressure. A field test was conducted where the sensor was deployed in a test wellbore at the Quest drilling test facility to a depth of 0 feet over three weeks. The sensor was attached to the production rods, along with a downhole reference sensor of PPS27 type, which is a permanent downhole monitoring system. During the testing phase, the test well annular blow-out preventer was closed, and the well was pressurized at the surface to 11 MPa (1600 psi). The sensor read the elevated bottom hole pressure of 1500 psi. A multiplexing unit was created for the sensor to deploy multiple sensors on one data transmission line in a distributed approach. The multiplexing unit was tested in a simulated environment of 3048 m (10,000 ft) with five sensors distributed. The sensors were pressurized at different intervals. The multiplexed sensors recorded the correct pressure, and the multiplexing did not interfere with the readings. The proposed concept of an all-digital pressure sensor for harsh downhole environments was designed, manufactured, and tested in the laboratory and tested at the field to a up to 69 MPa and 250°C. This technology has high-temperature tolerance and has potential in downhole areas outside oil and gas, such as carbon capture and storage (CCS) and geothermal wells. The sensor concept has been proven in this project, but to create a commercially viable product, manufacturing a sensor with a smaller diameter needs to be performed.

02 PETROLEUM↗

The Roadrunner Trap: A QSCOUT Device

The Roadrunner ion trap is a micro-fabricated surface-electrode ion trap based on silicon technology. This trap has one long linear section and a junction to allow for chain storage and reconfiguration. It uses a symmetric rf-rail design with segmented inner and outer control electrodes and independent control in the junction arms. The trap is fabricated on Sandia’s High Optical Access (HOA) platform to provide good optical access for tightly focused laser beams skimming the trap surface. It is packaged on our custom Bowtie-102 ceramic pin or land grid array packages using a 2.54 mm pitch for backside pins or pads. This trap also includes an rf sensing capacitive divider and tungsten wires for heating or temperature monitoring. The Roadrunner builds on the knowledge gained from previous surface traps fabricated at Sandia while improving ion control capabilities.

42 ENGINEERING↗

Friction Experiment Data Analysis

The Spent Fuel Waste Disposition (SFWD) program under the U.S. Department of Energy (DOE) is planning a seismic shake table test of full-scale dry storage systems of spent nuclear fuel (SNF) to close the gap related to the seismic loads on the fuel assemblies in dry storage systems. This test will allow for quantifying the strains and accelerations on surrogate fuel assembly during representative earthquakes. A concrete layer will be installed on the shake table before the test to simulate conditions representative of an ISFSI pad. In the shake table tests with the vertical cask, the cask will be free-standing because this is representative of all, except two, ISFSIs in the U.S. with vertical dry storage casks. The static and dynamic friction coefficients between the steel bottom of the cask and the concrete layer on the shake table are important parameters that will affect cask behavior during the test. These parameters must be known for the pre- and post-test modelling, data analysis, and model validation. The friction experiment was performed at the Engineering Department of the University of New Mexico (UNM) to determine the friction coefficients between a steel plate with the same finish as the bottom of the vertical cask manufactured for the test and different concrete surfaces. In this experiment the steel plate was fixed and the concrete sample was pulled over the plate with a constant displacement rate using an MTS machine. This allowed for collecting continuous horizontal force data over the length of the steel plate. Four displacement rates and three vertical loads were used. The tests were performed with four concrete blocks with different degrees of the surface roughness - light sandblast, light to medium sandblast, medium bush hammer, and heavy sandblast. The total number of tests was 48. The data were used to calculate static and dynamic friction coefficients.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Heterogeneous Integration Technologies for High-temperature, High-density, Low-profile Power Modules of Wide Bandgap Devices in Electric Drive Applications (Final Technical Report)

The goal of this project is to develop packaging technologies for making high-temperature, high-density, and low-profile wide-bandgap (WBG) power electronics modules for electric drives. These modules are aimed at enabling the DOE’s University Consortium to reach its 2025 inverter targets of ≥ 100 kW/L and ≤ 2.7 $/kW. The specific objectives are to: design and fabricate SiC half-bridge power modules with double-sided cooling and parasitic inductances < 5 nH, heat flux density > 400 W/cm 2 , and working junction temperature of 200 o C; design, fabricate, and deliver a gate driver with double-sided cooled modules for the construction of a 100 kW/L inverter at Oak Ridge National Lab; and design and prototype intelligent gate drivers with integrated current sensor and a low-profile DC-DC power supply with air-core transformer for testing power modules at 200 o C junction temperature. We followed an iterative technical approach of design, simulation, fabrication, and testing of various versions of modules, current sensors, and power supply. The state-of-the-art silicon carbide devices rated at 1.2 kV and 149 A were packaged by sintered-silver bonding on an aluminum nitride direct-bond-copper substrate for high thermal conductivity, high working temperature, and high joint reliability. Porous silver posts were used to interconnect the device’s source pads to the other direct-bond-copper substrate for low mechanical stresses, ease of manufacturing, and double-sided cooling. A current sensor based on package parasitic inductance was developed to measure switching current. A dynamic feedback scheme was developed to compensate the effect of parasitic resistance and temperature variation. A constant-current class-E dc-dc converter with air-core transformer was developed. Air-core transformer was used due to the unavailability of magnetic core at high temperatures. Gate driver and power supply were integrated with the double-side cooled, high temperature SiC power modules for testing the modules at 200 o C junction temperature. Double-pulse and continuous testing of the integrated technologies validated the design and fabrication of the three component technologies. Throughout the project, we overcame the challenge for design verification caused by low prototyping yield, which then helped train the graduate students, the future workforce, to learn the engineering know-how for low-cost manufacturing of reliable products. Below is a summary of the major accomplishments of this project: development of a prototyping process for fabricating double-side cooled (1200 V, 149 A) SiC phase-leg modules capable of working to 200 o C Tj; simulation and experimental verification of the improvement of thermo-mechanical reliability of the double-side cooled SiC phase-leg module by using rigid encapsulant; design and experimental validation of a current sensor based on package parasitic inductance and a compensation solution for eliminating the effect of parasitic resistance; design and experimental validation of a low-profile power supply with six-output air-core transformer for gate driver; functional demonstration of a SiC phase-leg module integrated with its gate driver, current sensor, and an air-core power supply at 200 o C Tj in a double-pulse switching test setup and Buck converter continuous test setup; successful completion of six PhD and two MS students who are or will work at Apple Inc., Tesla Inc., Wolfspeed Inc., Microchip Inc., Monolithic Power Systems Inc., and LG Magna Inc.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing Development of Emissions Detection (Final Report)

This document is the final report to the U.S. Department of Energy (DOE for contract DE-FE0031873) awarded to Colorado State University (CSU). CSU and partners at Harrisburg University of Science and Technology, University of Texas Arlington, and University of Texas at Austin organized several testing rounds to provide knowledge focused on advancing the detection capabilities of emissions monitoring devices. With this funding opportunity the research group began by establishing the Advancing the Development of Emission Detection (ADED) program, with the goal focused on enhancing the accuracy, reliability, and field applicability of methane detection technologies. This effort aimed to address the critical challenges of identifying and quantifying methane emissions while enabling industry stakeholders to meet regulatory compliance and environmental sustainability goals. The program engaged with industry, government, and technology stakeholders to promote adoption and consensus on testing techniques for methane detection solutions. Methane, a potent greenhouse gas, contributes significantly to global warming, and the oil and natural gas (O&G) sector is a primary source of methane emissions. Regulatory measures such as leak detection and repair (LDAR) programs have been implemented to address emissions. However, traditional LDAR approaches, reliant on handheld and component-level measurements, are resource-intensive. To address these limitations and move with evolving regulations, advanced methane technologies are emerging. These solutions include ground-based sensors, mobile systems (e.g., drones, vehicles, and aircraft), and satellite-based platforms. They offer innovative capabilities for autonomous monitoring, larger spatial coverage, and emission quantification using methods such as tracer gas techniques and inverse modeling with Gaussian plume analysis. The ADED program began with creating protocols for methane controlled release (CR) testing these continuous monitoring (CM) and survey technologies that detect and monitor methane emissions at O&G facilities. The protocols were then implemented throughout testing of CM and survey devices at CSU’s Methane Emissions Technology Evaluation Center (METEC) facility from 2021 through 2024. As apart of the protocol, solutions that tested under the ADED program installed their solutions at METEC, documented their system under test, and provided detection reports to the METEC team for analysis. The METEC team would provide the solutions with analyzed reports of their emissions and ground truth data of the releases conducted during their testing session. Under the ADED program, CMs were also tested at O&G facilities for a six week test run of challenge release (ChR) releases. The findings from the ADED program underscore the critical role of collaborative research and innovation in tackling methane emissions, offering a pathway for the oil and gas sector to achieve significant environmental and economic benefits. Results from METEC testing saw improvement of performance and accuracy across all solutions over the extent of the ADED experiments. The results also showed a variance in CM solution performance between CRs and ChRs. That variance pushed the team to further analyze the differences between CR testing environments and field conditions. With the drive from regulations and that variance in field conditions, the ADED team began designing a new CR testing protocol and additions to the METEC testing facility. The METEC team is furthering the progress made through the ADED program with awarded funding from DE-FE0032276. This funding pushes the development of METEC’s addition with new equipment, allowing for an updated facility layout. METEC still facilitates for traditional facilities, with a legacy pad, while expanding an new design based on how O&G infrastructure has Final Report - Contract Number: DE-FE0031873 been changed over the last decade. Throughout the ADED program the team has also been working with international partners to ensure staying in the trend globally. International partners have been essential in moving the new protocol forward to implement into CR testing at the METEC facility in Spring 2025.

42 ENGINEERING↗

Non-catalytic pyrolysis of associated gas to zero CO 2 hydrogen and high value carbon black

The overall objective of this work is to perform a pre-Front End Engineering Design (pre-FEED) study of the conversion of associated gas produced at an active oil pad of a Bakken oil field producer, to high value carbon black and hydrogen using the Microwave Plasma Pyrolysis of Associated Gas (MPP-AG) process developed by H Quest Vanguard, Inc (HQV). The University of North Dakota’s Center for Process Engineering Research (CPER) collaborated with HQV to complete a design and techno-economic analysis for the MPP-AG deployed at an active Bakken well site flaring an average of 54,000 standard cubic feet per day of AG. The proposed design consists of: • A Microwave Pyrolysis Unit (MPU) which consists of H Quest’s proprietary MPP technology • A patent-pending Gas Conditioning Unit (GCU) designed by the University of North Dakota to condition intermittent and variable flow gas prior to pyrolysis. • An auxiliary unit running on the associated gas to power the GCU and MPU in an “island mode” configuration.

03 NATURAL GAS↗

Hardware-Based Demonstration of Temperature Control Functions for Reactor Systems

Establishing autonomy in reactor control systems has become essential for the expansion of nuclear technologies. Thermal regulation in particular remains crucial for maintaining stable operation and ensuring the integrity of fuel. To alleviate public skepticism of the safety of nuclear reactors, demonstrating control over this key factor is pivotal. Utilizing electric heat pads to simulate the heat released in a reactor core, thermocouples for temperature monitoring, and an Arduino micro programmable logic controller (PLC) for control, a hardware-based demonstration of a reactor heating system validates the efficacy of reactor control over this key parameter. To improve precision, a proportional-integral-derivative (PID) algorithm was implemented in the heating control loop to ensure meticulous control of reactor functions. In addition, the integration of this physical system with a digital simulator tool such as RELAP5-3D establishes a foundation for a comprehensive testing environment. This allows for a refinement of temperature control under various simulated reactor conditions, bringing another layer of reliability to the operation of the system. By facilitating a physical demonstration of reactor thermal management and control strategies, this project provides a foundation for expanded testing and educational outreach. Ultimately, this system advances the broader goal of demonstrating the safety and viability of autonomous reactor operations, contributing to public trust and future reactor deployment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Project Presentation: Hardware-Based Demonstration of Temperature Control Functions for Reactor Systems

Autonomous thermal regulation in nuclear reactors remains crucial for maintaining stable operation and ensuring the integrity of fuel. To alleviate public skepticism of the safety of nuclear reactors, demonstrating control over this key factor is pivotal. Utilizing electric heat pads to simulate the heat released in a reactor core, thermocouples for temperature monitoring, and an Arduino micro programmable logic controller (PLC) with an embedded proportional-integral-derivative (PID) algorithm for control, a hardware-based demonstration of a reactor heating system will validate the efficacy of reactor control over this key parameter. This report covers internship project presentation as well as relevant experience with nuclear and proposal for project upgrade.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Update: structural uncertainty of used nuclear fuel in dry storage canisters

The Structural Uncertainty research task uses numerical modeling to help close knowledge gaps associated with extended dry storage of used nuclear fuel. Modeling helps to predict the expected range of mechanical loading on used nuclear fuel and dry storage system components, which is needed to help guide materials research. Knowledge of expected loads helps the materials researchers prioritize their research and focus only on the relevant material degradation phenomena that can have an effect on the ability of dry storage systems to function. The loads considered in this task are DSC tip-over, handling drops of the multipurpose fuel canister, and seismic loading of DSC systems while situated on the concrete pad of a storage facility. This document is a progress report that describes the work that was performed in fiscal year 2015. The work is a broad task that considers a number of physical phenomena and uses sophisticated LS-DYNA finite element models to predict used fuel and DSC system response to dynamic loads. Due to the broad list of topics and limited budgets, the topics of this task are prioritized at the beginning of the year and the priorities are subject to revision throughout the year as the Pacific Northwest National Laboratory team collaborates with other members of the Used Fuel Disposition Campaign. This year, three topics were investigated: options for modeling cladding in LS-DYNA, the effect of cladding thinning in the tip-over load case, and stress corrosion cracking in multipurpose canister welds. In each of these cases, significant progress was made. This report details the work that was done and identifies areas where more work is needed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mitigation for the demolition of the foundation of building 25-3113/3113a, area 25, Nevada national security site, NYE county, Nevada

The purpose of this letter report is to document the mitigation of adverse effects of a proposed undertaking that would demolish the foundation of Building 25-3113/3113A and the adjoining test pad at Test Cell A in Area 25 of the Nevada National Security Site (NNSS) in compliance with the terms of the 2024 Programmatic Agreement among the U.S. Department of Energy and the Nevada State Historic Preservation Officer and the Advisory Council on Historic Preservation Concerning the Protection of Historic Properties on the Nevada National Security Site, Nye County, Nevada (NNSS PA). The foundation of Building 25-3113/3113A (State Historic Preservation Office [SHPO] Resource # B2443) is a contributing element to the Nuclear Rocket Development Station (NRDS) Historic District (SHPO Resource # D424), which has been determined eligible for listing in the National Register of Historic Places (NRHP) under Criteria A, B, C, and D (Reno et al. 2023). The proposed demolition constitutes an adverse effect. The U.S. Department of Energy (DOE) National Nuclear Security Administration Nevada Field Office (NNSA/NFO) consulted with the SHPO on an adverse effect finding for the undertaking and notified the SHPO of its intent to use the standard mitigation in the NNSS PA on December 11, 2024 (Julian to Reed). The SHPO concurred on December 30, 2024 (Reed to Julian). Therefore, NNSA/NFO has prepared mitigation pursuant to the standard mitigation in the NNSS PA Appendix D.I.A for contributing elements to recorded, NRHP-eligible districts.

#B2443↗

Mechanical Characterization of the NIF Ignition Target TMPSA Bonding Flexure

The Thermo-Mechanical Package Sub-Assembly (TMPSA) provides a critical mechanical, thermal, and electrical interface between a silicon arm and a TMP aluminum can in a NIF ignition target. During assembly, sixteen silicon pads are bonded to the aluminum using a fixture that positions the components and applies a repeatable prescribed displacement through a compliant flexure. The flexure converts fixture interference into displacement and reaction force. Because bondline thickness variation must be maintained within +/-4 µm, consistent flexure behavior is important to the assembly process. With a recent string of TMPSAs exhibiting low bond strength, the flexures were inspected. Despite being manufactured to the same specifications, flexures were found to exhibit variation in measured stiffness. Additionally, the measured stiffness values did not always follow the presumed beam mechanics model. This work addresses two questions: whether the bonding fixture is working as intended, and whether the previously made stiffness measurements are accurate representations of the use case. The flexures are analyzed using Euler-Bernoulli beam theory, measured beam dimensions, finite element analysis, and tolerance stack-up calculations. The analysis shows that the fixed-guided beam mechanics model appropriately represents the flexure during TMPSA bonding, but the chisel-tip stiffness measurement method introduces a deformation to the inner ring of the flexure that is not represented during use. The measured stiffness values should therefore be interpreted as test-condition stiffness values rather than direct measurements of operational flexure stiffness. The discrepancy is therefore attributed primarily to the measurement boundary condition rather than to failure of the fixed-guided beam model. Recommendations are provided for GD&T, dimensional inspection, and a representative stiffness testing method to better control bondline variation.

42 ENGINEERING↗

Synthetic Sling Failure - Evaluations and Recommendations

The information and evaluations provided in this report were compiled to address the recurring problem of synthetic sling failure. As safety is the number one priority in all work aspects, a solution must be devised to prevent accidents from occurring. A total of thirteen cases regarding synthetic sling failure were evaluated in order to determine their causes, effects, and preventative measures. From the collected data, it was found that all cases in which the synthetic sling contacted the edge of its load resulted in sling failure. It is required that adequate synthetic sling protection devices be used to protect slings in any lift where the sling comes in direct contact with the edge or corner of its load. However, there are no consensus codes or standards stating the type, material, or purpose of the type of protective device used to protect the sling from being cut. Numerous industry standards and codes provide vague descriptions on how to protect synthetic slings. Without a clear, concise statement of how to protect synthetic slings, it is common for inadequate materials and sling protection devices to be used in an attempt to meet the intent of these requirements. The use of an inadequate sling protection device is the main cause of synthetic sling failure in all researched cases. Commercial sling protection devices come in many shapes and sizes, and have a variety of names, as well as advertised uses. 'Abrasion pads' and 'wear protectors' are two different names for products with the same intended purpose. There is no distinguishable way to determine the extent of sling protection which these devices will provide, or what specific scenarios they are made for. This creates room for error in a field where error is unacceptable. This report provides a recommended action for hoisting and rigging activities which require synthetic slings to contact a load, as well as recommended changes to industry standards which will benefit overall industry safety.

42 ENGINEERING↗

Evaluation Of Automated Low-Field Nuclear Magnetic Resonance (NMR) Relaxometry For Analysis Of Silicone Polymers

Screening studies and Design of Experiments (DoE) were performed to evaluate measurement variation of a new, non-destructive Nuclear Magnetic Resonance (NMR) test system designed to assess age-induced degradation of Outer Pressure Pads (OPP). The test method and results from 54,275 measurements are described. A reduction in measurement error was obtained after metal support struts were replaced with plastic support struts adjacent to the front position of the test chamber. However, remaining interference and a lack of detecting any age-related degradation prevent the use of the NMR system as a non-destructive surveillance test for OPPs. A cursory evaluation of the system with cellular silicone samples obtained more uniform results with increased error as measurements approached the sample’s edge.

36 MATERIALS SCIENCE↗

Basic Data Report for Drillhole SNL-18 (C-3233)

SNL -18 (permitted by the New Mexico (NM) State Engineer as C.3233) was drilled and completed during June 2006 to provide geological data and hydrological testing of the Culebra Dolomite Member of the Permian Rustler Formation along the margin of the northeastern arm of Nash Draw, north of the Waste Isolation Pilot Plant (WIPP) site. SNL -18 is in the area where upper Salado Formation halite has been dissolved and is in the mudflat facies tract of Rustler mudstone -halite units. Culebra transmissivity is expected to be relatively high. SNL -18 is located near the southeast corner of section 20, T21S, R31E, in eastern Eddy County, NM. SNL.18 was drilled to a total depth (TD) of 566 feet (ft) below ground level (bgl), based on driller’s measurements. Below the caliche pad, SNL.18 encountered poorly consolidated sands, the Mescalero caliche, and the Gatuña, Dewey Lake, and Rustler Formations. The Santa Rosa and upper Dewey Lake have been eroded at SNL -18. The Rustler was cored from the lower Forty-niner Member into the upper Culebra Dolomite Member, with generally poor recovery. Geophysical logs were acquired from the open hole to a depth near TD. Water was encountered in the interval including lower Dewey Lake to Forty -niner Member. SNL -18 was drilled to 307 ft (Dewey Lake) using air. Air and mist were used to drill and core from 307–496 ft. From 496 ft to TD, mud was used for drilling and coring with poor to no returns circulating to the surface. Coring was abandoned in the upper Culebra Dolomite due to hole conditions. Core recovery was variable, and cuttings are limited to lacking below 496 ft. Cement was pumped into the drillhole to control loss of circulation and fill during drilling. The Los Medaños was drilled through mudstone 2 (M -2) and into the top of anhydrite 1 (A -1) based on geophysical logs and drilling rates. The thickness of M -2 is normal. No cuttings were obtained.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RCRA Part A and Part B Permit Application for Waste Management Activities at the Nevada Test Site: Proposed Mixed Waste Disposal Unit (MWSU)

The proposed Mixed Waste Storage Unit (MWSU) will be located within the Area 5 Radioactive Waste Management Complex (RWMC). Existing facilities at the RWMC will be used to store low-level mixed waste (LLMW). Storage is required to accommodate offsite-generated LLMW shipped to the Nevada Test Site (NTS) for disposal in the new Mixed Waste Disposal Unit (MWDU) currently in the design/build stage. LLMW generated at the NTS (onsite) is currently stored on the Transuranic (TRU) Pad (TP) in Area 5 under a Mutual Consent Agreement (MCA) with the Nevada Division of Environmental Protection, Bureau of Federal Facilities (NDEP/BFF). When the proposed MWSU is permitted, the U.S. Department of Energy (DOE) will ask that NDEP revoke the MCA and onsite-generated LLMW will fall under the MWSU permit terms and conditions. The unit will also store polychlorinated biphenyl (PCB) waste and friable and non-friable asbestos waste that meets the acceptance criteria in the Waste Analysis Plan (Exhibit 2) for disposal in the MWDU. In addition to Resource Conservation and Recovery Act (RCRA) requirements, the proposed MWSU will also be subject to Department of Energy (DOE) orders and other applicable state and federal regulations. Table 1 provides the metric conversion factors used in this application. Table 2 provides a list of existing permits. Table 3 lists operational RCRA units at the NTS and their respective regulatory status.