Search NASA⌕ Search

SEARCH · Search NASA

Results for “Paper”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Recent Advances in the Use of TRIPOLI-4 Monte Carlo Code for Radiation Protection and Shielding Calculations - Paper 47

TRIPOLI-4 is a general purpose radiation transport code. It uses the continuous-energy Monte Carlo method to simulate neutron, photon, electron and positron transport in three-dimensional geometries. The main application areas of TRIPOLI-4 code include radiation protection and shielding, fission reactor physics, nuclear criticality safety, fusion reactor design, and nuclear instrumentation. For the radiation protection and shielding calculations with TRIPOLI-4 code, miscellaneous radiation sources options, various variance reduction options, and many useful tally options are available. Perturbation calculations on material densities and nuclide concentrations are routinely used in radiation protection applications. Parallel calculations with TRIPOLI-4 are also easy to perform with a PC under the linux/unix OS. To help the users to get the feedback from their test runs during the input data preparation and adjustment and to analyze the intermediate and final results from their production runs, several user-interface tools have been introduced. By using some application cases in the fields of radiation shielding, radiation dosimetry, and gamma spectrometry, this paper summarizes and demonstrates some essential improvements and possibilities in the use of TRIPOLI-4 code on fixed source calculations. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

On the Ill-Posed Nature of Inverse Problems: An Exactly Solvable Paradigm Inverse Neutron Diffusion Problem Illustrating the Solution's Non-Computability - Paper 48

In general, a physical system and/or the result of an indirect experimental measurement are modeled mathematically in terms of: (a) A system of linear and/or nonlinear equations that relate the system's independent variables and parameters to the system's state (i.e., dependent) variables; (b) Probability distributions, moments thereof, inequality and/or equality constraints that define the range of variations of the system's parameters; (c) One or several quantities, customarily referred to as system responses (or objective functions, or indices of performance), which are computed using the mathematical model. The 'direct problem' solves the 'parameter-to-output' mapping that describes the 'cause-to-effect' relationship in the respective physical process. In practice, the model parameters and/or responses are experimentally measured quantities and are therefore subject to uncertainties. Many measurement problems are 'inverse' to the direct problem in that they seek to determine the properties of the medium (i.e., various cross sections), or the properties of the source, and/or the size of the medium on its boundaries from measurements of quantities that depend on the neutron flux (or from direct measurements of the neutron flux). In general, two problems are called inverses of one another if the formulation of each involves all or part of the solution of the other. Some authors further group such inverse problems into 'invasive', when the interior flux is accessible for measurements as opposed to 'non-invasive', in which only fluxes on the boundary of (or exterior to) the medium can be measured. Examples of inverse radiative transfer problems have been reviewed by McCormick, while examples of inverse source problems for neutron transport have been provided by Sanchez and McCormick. More recently, Bledsoe et al., have presented two methods (the Levenberg-Marquard, and 'differential evolution method') for addressing numerically inverse transport problems. However, although these works (as well as other works cited therein) mentioned the detrimental effects of 'small perturbations in the input data', none of the works published thus far on inverse problems for particle transport or diffusion actually showed explicitly the effects that uncertainties in the measured responses (e.g., detector measurements) would actually have on the 'inverse' deduction (from such measurements) of the underlying medium's properties, sources, etc. This work highlights explicitly the nature of the difficulties encountered in so-called 'inverse problems' by presenting a paradigm inverse neutron diffusion problem admitting an exact solution, in which the 'inverse problem' is to determine the medium's diffusion coefficient from flux measurements. It will be shown explicitly (analytically) that this is not possible to achieve in a unique manner, even in the absence of measurement uncertainties, unless additional error-free information is provided about the quantity to be determined (in this case, the medium's diffusion coefficient). It if further shown that, even if this additional error-free information about the diffusion coefficient to be determined is available, the unavoidable experimental measurements errors, albeit it vanishingly small, in the measured flux render the 'exact solution' useless for computational purposes, since the exact solution turns out to be a divergent series. As discussed in this paper's ENDNOTES section, the paradigm problem presented in this work also underscores the need for 'regularization', which is a qualifier indicating that the inverse problem is to be solved in some approximate manner. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Parallel Monte Carlo Methods for Heterogeneous Hardware Computer Systems Using GPUs and Coprocessors: Recent Development of ARCHER Code - Paper 54

Traditional methods of accelerating Monte Carlo (MC) calculations typically use CPUs as the computing unit. The parallelism is based upon multithreading on a multi-core processor, and message passing interface (MPI) across many processors and nodes. In recent years, the hardware accelerators have been introduced by the high performance computing industry as an alternative approach to achieve massive parallelism. Hardware accelerators have the advantage of high Floating-point Operations Per Second (FLOPS) and high energy efficiency. Examples include graphics processing units (GPUs) and coprocessors. Compute-intensive programs can be off-loaded to them to be concurrently executed by hundreds or thousands of active threads. Existing production MC codes, however, cannot be directly compiled or executed on the new platforms. It is therefore necessary to rewrite or redevelop the code using the hardware accelerator specific programming models and APIs. Several studies have been conducted on using GPUs to accelerate MC calculations in reactor analysis and medical physics. In this paper, we present the recent progress at Rensselaer Polytechnic Institute (RPI) in developing a new parallel MC code called ARCHER (Accelerated Radiation-transport Computations in Heterogeneous Environments) for coupled photon-electron transport simulations. The code is designed as a test bed to evaluate the efficacy of heterogeneous computing systems for low-cost MC-based radiation dosimetric calculations. The code has three variants corresponding to three parallel hardware platforms: ARCHER-CPU (multi-core CPU), ARCHER-GPU (Nvidia GPU) and ARCHER-COP (Intel Xeon Phi coprocessor). The code has been used for several applications, including CT imaging dosimetry, radiotherapy dosimetry and radiation shielding design. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Colloid Rates of Radionuclides in Cooling Water of the 120-GeV Proton Accelerator Facilities at Fermilab - Paper 58

Cooling water systems for high-energy accelerators are typically equipped with a deionizer to keep water pure for accelerator materials and to remove radionuclides for radioactivity control. Although the deionizers are expected to collect the entire radionuclides, more radioactivity than expected remains in the cooling water in typical cooling water operations at J-PARC and the Tsukuba Campus of High Energy Accelerator Research Organization (KEK), Japan. For example, specific activity of {sup 7}Be in the cooling water for magnetic horns at the J-PARC Neutrino Experimental Facility was observed to be comparable to the limit of {sup 7}Be activity for drain (30 Bq/mL) after enough deionization duration. Removing this activity from the cooling water is an important problem that must be solved before the water can be released into the environment. In our previous study, it was found that some radionuclides had weak retention on ion-exchange resins in the cooling water deionizer system for the K2K target and magnetic horns at the 12-GeV proton accelerator in KEK, Japan. Incomplete adsorption in the deionizer was attributed to colloid formation. Therefore, understanding the colloid formation of radionuclides in cooling water is important for understanding the activity remaining in the cooling water. Colloid formation in water under high-intensity radiation fields has been investigated by previous irradiation experiments. Under 120-GeV proton irradiation of Cu foils in water, it was found that the colloid formation rates of Mg, Mn, Co, Ni, and Cu isotopes and those of {sup 7}Be, {sup 24}Na, {sup 42}K, and {sup 43}K were approximately 30% and 1.8-3.9%, respectively. Sc, Cr, and Fe isotopes were missing from the water. In the photon irradiation of water in a Cu tube using Bremsstrahlung from an electron linear accelerator and a {sup 60}Co γ-ray source at Kyoto University Research Reactor Institute, we observed Cu colloid formation in consequence of the corrosion of Cu. It is possible that radionuclides attach to the colloids formed by the corrosion of accelerator materials and pass through the deionizer. To enhance the understanding of the behavior of radionuclides in cooling water in a high-energy accelerator environment, we investigated the colloid formation of radionuclides in cooling waters at the 120-GeV proton accelerator facilities at Fermilab, USA. We have already reported the previous results of specific activities of γemitting radionuclides and {sup 3}H in water samples collected from eight cooling water systems. Following the previous study, this paper is concerned with the measurement of colloid formation rates of radionuclides in cooling waters. (authors)

43 PARTICLE ACCELERATORS↗

Application of the GBFP Method to Electron Partial-Wave Expansion Elastic Scattering Differential Cross Sections Within the Geant4 Toolkit - Paper 69

Analog Monte Carlo simulation of electrons in complex material geometries is generally impractical because the long range Coulomb interactions result in highly peaked differential cross sections (DCS) for scattering and energy-loss and extremely small collision mean free paths (mfp). The condensed history (CH) Monte Carlo method attempts to alleviate this limitation by advancing electrons in fixed steps and sampling angular deflections and energy losses from precomputed distributions obtained from approximate solutions to the underlying transport equation that are valid only for thin layers. Though CH is efficient and is widely employed in production codes (ITS, MCNP, EGS, Geant), step size restrictions and inconsistent handling of material and free surface boundaries limit the ultimate accuracy possible with this approach, especially in applications to highly heterogeneous media. Recently proposed alternatives to the CH method, such as the Generalized Boltzmann Fokker-Planck (GBFP) method, restore the correct transport mechanics by simulating single events based on a Boltzmann transport equation but with efficiency and accuracy achieved through the use of reduced-physics interaction models. Motivated by Lewis theory, various moment-preserving strategies are employed in the GBFP approach to construct DCSs that are less singular, and with mfps shorter than analog. Specifically, the approximate cross sections are constructed to rigorously preserve a finite number of angular and energy-loss moments of the analog DCSs while all higher moments are approximated in terms of the exact lower moments. By systematically increasing the number of moments retained, any desired accuracy can be obtained for integrated quantities, such as dose, reflection and transmission yields, as well as distributed quantities such as energy and angular distributions. For relativistic Rutherford cross section models, the GBFP method has been demonstrated in Monte Carlo simulation to yield accuracy comparable to analog but at a fraction of the cost. One advantage of the GBFP approach is that angular deflection and energy-loss interactions depend only on Legendre moments and energy-loss moments and not the detailed form of the analog DCSs. This feature allows moment-preservation to be enforced through DCSs expressed as a superposition of discrete (i.e., using delta-functions) angular deflections and discrete energy losses. This promotes extremely efficient computation when compared to analog and completely continuous or hybrid discrete-continuous moment-based DCS reconstructions, while yielding highly accurate results for integrated and distributed quantities. In this paper, we demonstrate that the moment-preserving algorithms central to our fully discrete GBFP method can be readily extended to apply to tabulated DCS data, specifically to the partial-wave expansion (PWE) elastic scattering DCSs. Since data libraries for the PWE DCSs for energy and material combinations of interest can be prohibitively large, the GBFP method provides a means to reduce data storage requirements. We implemented our algorithm in the Geant4 Monte Carlo code and all numerical results are obtained using this implementation. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation Protection and Dosimetry in Medicine - An Overview - Paper 82

In recent years, radiological protection, radiation safety and dosimetry issues have emerged concerning the medical applications of ionizing radiation. Amongst several other issues, the dissemination of the use of Computer Tomography (CT), including for paediatric exams and the growing number of interventional radiology and interventional cardiology procedures have contributed to raise the concerns about the need to more fully justify the medical practices using ionizing radiation and to optimize the protection, reducing the dose to the patients and to the medical staff in the medical applications of ionizing radiation. The importance of implementing the principle of justification in the medical exposures and to further progress in the implementation of the principle of optimization of the protection is of paramount importance for the establishment of a robust international system of radiological protection. The consideration of radiosensitivity issues became mandatory in order to address different issues such as the paediatric CT exposures and the risk of secondary cancer induction in patients years or decades after radiation treatments. Low-dose radiation research also gained a renewed interest in order to overcome longstanding unresolved issues concerning namely the relationship between the radiological risk versus dose in the low dose region characteristic of the medical radiodiagnostic procedures and to shed some light in the mechanisms associated to the biological effects induced by ionizing radiation. Last but not least, the safety of radiotherapy treatments has also driven considerable efforts from the international community of experts, with the aim of reducing the number of incidents and accidents leading to the overexposure of patients to ionizing radiation. In this paper, an overview of the aforementioned topics is provided, considering the international Basic Safety Standards, European Union Directives and national regulations. Views and policies from international organizations such as the IAEA, the WHO and studies and reports from institutions such as the UNSCEAR, ICRP and the NCRP will be conveyed. Recent or ongoing epidemiological studies will be mentioned. Radiological protection and dosimetry of the patient and the workers in the medical applications of ionizing radiation will be discussed. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Testing the Delayed Gamma Capability in MCNP6 - Paper 86

The mission of the Domestic Nuclear Detection Office (DNDO) is to quickly and reliably detect unauthorized attempts to import or transport special nuclear material (SNM) for use against the United States. Developing detection equipment to meet this objective requires accurate simulation of both the detectable signature and detection mechanism. MCNP6 is capable of transporting the various types of radiation encountered in these scenarios; however, the accuracy of MCNP6 must be quantified such that we can be confident in the results of the simulations. Delayed gamma transport is one important component of these detection scenarios. Delayed gamma transport is defined as the combination of gamma emission from radioactive and subsequent transport through matter. MCNP always possessed the ability to emit delayed neutrons from fission; however, these delayed neutron spectra and intensity were functional fits and not directly sampled from the created fission products. Furthermore, there existed no method to emit the decay photons from radioactive fission products (or any radioactive nucleus) A delayed particle capability was initially added to MCNPX 2.6.A in 2005 to sample the radioactive fission product parents and emit decay particles resulting from the decay chain. At the point of capture, a residual nucleus is created and decayed using the CINDER90 depletion code. MCNP only sends CINDER90 a residual radioactive nucleus and not a flux (i.e. capture rate). As a result, the Bateman equations for the solution are coupled first order differential equations with constant coefficients. Theoretically, these equations could be solved analytically; however, CINDER90 employs a numerical Markov linear chain scheme to solve these equations. This paper addresses a more simplified approach to benchmarking in order to best assess: (1) whether or not deficiencies exist in the current methodology for certain types of decay chains; and (2) paths forward for improving the delayed particle emission capability. We utilize closed form analytic solutions to the granddaughter equations for particular sets of isotope systems to compare the accuracy of the delayed gamma capability in MCNP6. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Identification of Leakage Spectra from Neutron Activation in Glass/Cherenkov Detectors - Paper 96

Oak Ridge National Laboratory has developed a new detector system concept that can be deployed in major US cities to identify the leakage spectrum of a nuclear weapon detonation. The detector is based on a small piece of glass that has been doped with an element that has a high activation cross section and creates a radioactive activation product with a reasonable length half-life. The decay of the activation product(s) after exposure creates Cherenkov light which can propagate to a photomultiplier and can be turned into a count-rate signal. The signal from each glass in each detector in a city can be individually analyzed to determine the amount of activation products produced in the initial exposure. Several activation products can be determined in a single glass if the half-lives are not the same. With a known source location and a detailed 3D model of a city, neutron transport simulations can be made by using a library of known sources to predict the activation amounts each source would have made in the glass detectors. A simple comparison of the measured activation amounts and the predicted activation amounts can identify the source spectrum contained in the library that is the best match. Choosing dopants with a large range in the threshold energy for the activation reactions can help to differentiate the spectra in the library. The method of matching the measured activation amounts to the predicted activation amounts to identify the source spectrum is similar to the analysis used for the passive Activation Foil Integrated Detector System (AFIDS), also developed at Oak Ridge National Laboratory. In AFIDS, wires or foils of known mass and isotopic composition are deployed before and then collected after exposure. Counting gammas in a nearby laboratory determines the activation amounts. The glass/Cherenkov system is active - it uses a battery-powered detector to count flashes of Cherenkov light and to communicate its count rates to a remote location for further analysis. Work has been performed in several areas, including glass making, automated detection and communication systems and software tools for analysis of the signal and source spectrum identification. Bell and Boatner have developed phosphate glasses that incorporate elements with high capture cross sections, and Hayward has simulated the response with Geant4 and measured the response with isotopic gamma sources. This paper will focus on the software tools for determining the activation amounts from the Cherenkov count-rate signal and finding the best matching source spectrum. A test problem in an urban environment is used to demonstrate the potential of a spectrum identification system using neutron activation. The analysis methods developed to identify the neutron leakage spectra from Cherenkov light given off by neutron activation in doped glasses work well. The calculation used to unfold the count-rate information into the number of actual activation products uses robust algorithms that can also compute associated uncertainties. These uncertainties and the known uncertainties of the glass tube material compositions are incorporated into the matching analysis to determine which of the source spectra in the library best matches the measured activation data. Any measurement method used to identify a neutron source spectrum relies at some point on a comparison against known sources; no identification method is definitive. Detection systems measure some physical aspect of the source, not its serial number. Many systems measure the physical aspect to determine that the source has some property, and then leave it to experts to determine which potential sources share that property. The analysis system presented here incorporates the comparison into the analysis itself. The statistical tests show which of the known library sources match the measured data the best and whether that match is a good match. If the best match still does not fit the measured data well (a very high χ{sup 2} value), that indicates the true source is not one of the sources in the library. This is still valuable information for decision makers. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dose Rate Analysis of As-Loaded Spent Nuclear Fuel Casks - Paper 97

Used Nuclear Fuel Storage, Transportation and Disposal Analysis Resource and Data System (UNF-ST[and]DARDS) is a comprehensive data and calculation capability for UNF safety assessments currently being developed at Oak Ridge National Laboratory through a collaborative effort of multiple national laboratories and industry participants. The purpose of UNF-ST[and]DARDS is to provide a unified domestic UNF system of data and analysis capabilities in support of U.S. Department of Energy waste management and fuel cycle-related objectives. UNF-ST[and]DARDS is designed to provide safety assessments for UNF storage, transportation, and disposal systems based on actual characteristics of the as-loaded UNF (e.g., fuel assembly burnup, enrichment, decay time, cladding integrity, etc.). The cask-specific safety evaluations allow quantification of realistic safety margins and conditions and provide the technical basis for addressing concerns related to potential fuel failure (e.g., for high-burnup fuel). This paper describes the UNF-ST[and]DARDS methodology for calculating radiation dose rates for U.S. Nuclear Regulatory Commission (NRC) licensed casks based on actual UNF canister contents. Realistic dose rate values based on actual canister contents may be used in place of bounding dose rate values to support development of repackaging operations procedures, evaluation of radiation-related transportation risks, and communication with stakeholders. UNF-ST[and]DARDS capabilities have been recently expanded to include automated radiation source term calculations and dose rate analyses of as-loaded transportation casks. This unique capability determines realistic dose rate values based on actual canister UNF contents that may be used in radiation dose assessments to demonstrate safe transportation of commercial UNF. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Activation Neutronics for a Swiss PWR: Simulations and Validation - Paper 102

In Switzerland 40% of the electricity generation is produced by nuclear power. With all four NPPs being already beyond their 30. year of operation, Nagra in collaboration with the utilities periodically contributes to the Swiss NPP decommissioning cost estimation studies. The neutron induced activation of structures and components of the NPPs is of particular relevance for the planning of the dismantling actions, the waste-packaging concept, the waste-management considerations and, therefore, the estimation of decommissioning costs. In this context, Nagra has developed a calculation sequence in order to perform state-of-the-art neutron transport and activation calculations. In this paper, aspects relevant to the neutron transport calculations for estimating the residual radioactivity within a Swiss PWR are presented. More specifically, the MCNP5 modeling approach together with the use of the ADVANTG-hybrid code for accelerating the variance reduction efforts is outlined. Additionally, the validation of the neutron transport calculations with in-situ full-cycle foil activation campaigns is discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Use of the portable decay gamma source feature in the R2Smesh code system for the accurate estimation of photon radiation dose fields around activated ITER components - Paper 111

The R2Smesh ('Rigorous 2-step') code system, developed by KIT for the determination of shut-down dose rate distribution on mesh grid, can be utilized to provide photon radiation dose field around activated components which are moved from the irradiation site in fusion reactor to another external location. R2Smesh couples MCNP transport calculations and FISPACT inventory calculations through suitable interfaces utilizing MCNP mesh tally capability. Neutron flux and the decay gamma source are provided with high resolution on the mesh grid superimposed to the real geometry to take into account the spatial variations of the flux and the decay gamma source distributions. This feature enables the decay gamma source distribution to be transferred from the irradiation site in the reactor to any other external location for the determination of photon flux and dose rate distributions. In this work, we applied the feature of the portable decay gamma source in R2Smesh code system to a dose rate analysis for a tunnel connecting the ITER tokamak complex building (TCB) and the hot cell facility building (HCFB). This paper presents the use of the portability feature of the decay gamma source in R2Smesh interface code system developed by KIT for a dose rate analysis of the ITER tunnel connecting TCB and HCFB. This application shows that the decay gamma source of the activated components could be transferred successfully from one coordinate system to another coordinate system and superimposed to the geometry of the components. This is very useful when the activated components need to be transported from the reactor to somewhere else for maintenance, testing or storage and the dose rate analysis is requested. Another portable feature, which could convert the 3D decay gamma source distribution generated by R2Smesh system to the MCNP 'SDEF' card source description and avoid the use of source sampling subroutine, is under consideration. With this feature, one decay gamma source result for the specific reactor components could be shared by different institutions who need to use the same decay gamma source for different analysis. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Air Activation Calculations for Electron Linear Accelerators - Paper 114

Electron linear accelerators produce x-ray photons when the beam interacts with material such as beam stops or beamline components. These photons subsequently cause radioactivation in air, primarily through ({gamma},n) reactions. While most of these nuclides have short half-lives, they can lead to doses to personnel entering the accelerator or experimental areas and can be released to the environment. Accurate calculations are needed for the production, decay, and clearance of these nuclides. This paper discusses two treatments of air activation. An approximate treatment makes use of the fact that the Bremsstrahlung photon fluence is proportional to beam power and the path length in air, but does not account for heavily shielded loss points or how far the beam energy is above each reaction threshold. Using detailed radiation transport codes like MCNPX avoids these problems. Examples are provided for two electron linear accelerators at Argonne National Laboratory: the Low-Energy Accelerator Facility (LEAF) and the Argonne Wakefield Accelerator (AWA). MCNPX was used to calculate photonuclear reaction rates in the air at two electron accelerators at Argonne. Combined with realistic models for air exhaust, these results were used to calculate effects to facility staff, other personnel, and the environment. (authors)

43 PARTICLE ACCELERATORS↗

Preliminary Results of a New Deterministic Iterative Image Reconstruction Algorithm - Paper 117

Iterative reconstruction techniques have become the standard for Single Photon Emission Computed Tomography (SPECT). Advances in computing have allowed these techniques to incorporate more and more detail; however, computation time must be balanced against increased detail. Monte Carlo methods are generally used for modeling the physics of a SPECT study, but can have long computation times. Advances in Monte Carlo-based scatter correction have shown reasonable results, but scatter estimation by measuring narrow energy windows remains more common. An iterative reconstruction technique using a deterministic transport code has been proposed as an alternative. This paper presents preliminary results of the new technique in which the TITAN deterministic code completes the forward projection step in a maximum likelihood expectation maximization (ML-EM) reconstruction of SPECT data. The effectiveness of the deterministic algorithm is examined for a 2-dimensional phantom. This work demonstrates the feasibility of using the TITAN code in an iterative reconstruction algorithm. The appropriate deterministic parameters were chosen by comparing sinograms produced with different mesh sizes, quadrature sets, and anisotropic scattering orders. The TITAN code was then successfully used as the forward projection step in an iterative reconstruction algorithm with a 2-dimensional homogeneous phantom. The impact of deterministic parameters on reconstruction quality is being investigated, along with the incorporation of a smoothing filter. The TITAN source code is being modified to include the ML-EM algorithm and iteration steps. This will significantly improve computation time by eliminating the repeated reading and writing of files for each iteration and allowing some steps to be completed in parallel. Further testing of the new reconstruction algorithm for more realistic phantoms is also underway. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Neutronics for diagnostics in ITER - Paper 121

ITER, currently under construction in the south of France, will be the first tokamak producing large amounts of neutrons and having a fusion energy gain factor, which is the ratio between the fusion power produced and the input power necessary to maintain the plasma, greater than 10. ITER will be able to generate 500 MW of fusion power, from which 400 MW are 14.1 MeV neutrons from the Deuterium-Tritium fusion reactions in the thermonuclear plasma. For such nuclear machine neutronics are of paramount importance, being a design driver for many of its components, in particular its Ports and its numerous Diagnostics, for which the influence of neutronics is especially important in three main areas: - Shielding: there is a strong need to provide nuclear shielding to areas where human access is foreseen for maintenance. Also, to minimize any impact in the primary shielding components (blankets) in order to avoid significant increases in the heating of the Vacuum Vessel (VV) and Superconductive Coils. - Sensors and diagnostic components: most of the diagnostics have sensitive components that need to be shielded against radiation to survive. Efficient shielding is not always possible, and the radiation levels are usually the decisive factor for selecting the most appropriate component. - Neutron measurements: a large set of neutron diagnostics will be implemented to measure the neutron production and its emissivity profile. Although the scale and performance of ITER will not be very far from a commercial reactor, it is ultimately an experiment to improve the understanding of reactor-grade tokamak plasmas and their effect on plasma facing components. To accomplish this task, large efforts are being dedicated to design over 45 different diagnostics systems. This paper gives an overview of the main activities related to neutronics within the ITER Diagnostics Division. They include the neutron streaming problems in the Ports and the common neutronics issues of the diagnostics housed inside them, as well as the challenges of the in vessel diagnostics. Also the special calculations needed for the neutron diagnostics. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of CSG-based radiation shielding module for ARCHER: preliminary results for photons - Paper 126

ARCHER is a parallel Monte Carlo radiation transport code being developed for various hardware platforms including multi-core CPUs, the emerging Nvidia graphics processing units (GPUs) and Intel Xeon Phi coprocessors. Previous studies have demonstrated the accuracy and speed for CT imaging and radiotherapy dosimetry applications. Radiation shielding applications, however, require ARCHER to be more flexible in defining and handling geometries, in addition to the voxel phantom geometries that are commonly used in medical physics calculations. In this paper, we present the development of a general geometry module used for radiation protection and shielding problems in ARCHER. The methods of geometry design and particle transport for the GPUs are introduced. Preliminary results comparing against the MCNP code for cases involving Cs-137 0.662 MeV gammas are reported. The radiation shielding design module of ARCHER has been developed, which supports general geometry setups in the CSG format. The code was implemented using CUDA on Nvidia GPUs, and the performance was benchmarked against the MCNP code for a simple radiation shielding problem. Results showed that ARCHER worked properly and achieved impressive speedup due to highly parallel computing nature of the Nvidia GPUs compared to the MCNP code running on multi-core CPUs. Further optimization of the geometry module will be carried out using advanced geometry structures and variance reduction techniques to improve the precision and performance of ARCHER. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Determination of attenuation coefficients of heavyweight concretes containing colemanite by using {sup 133}Ba radioactive isotope source - Paper 140

As it is well known, colemanite is a boron ore. Boron is one of the most important underground richness of Turkey. Boron is employed as a constituent material of neutron shielding because of its high absorption of thermal neutrons. Barite ore includes BaSO{sub 4}, which is a well photon radiation absorbent. The literature about radiation attenuation in heavy concretes (including boron and barite ores) is fairly abundant. Abdo and Abdo et al. theoretically calculated and determined cross section by using XCOM computer program for photon and neutron radiations shielding. Akkurt et al. measured radiation transmission of heavy concretes including normal and barite aggregates for different γ-ray energies and calculated linear attenuation coefficients. Bashter et al. studied heavy concretes including hematite-serpentine, ilmenite-limonite as control absorber in nuclear reactors γ-rays and neutron particles shielding. Bashter and Bashter et al. studied heavy concretes including hematite-serpentine, ilmenite-limonite, basalt-magnetite, ilmenite, basalt, steel and magnetite for only photon radiation shielding and calculated linear and mass attenuation coefficients from 10 keV to 1 GeV. Dealmeid et al. studied radiation transmission and angular distribution for 25 MV X-rays by using LINAC. Demir and Keles measured radiation transmission of concrete including boron waste for 59.54 and 80.99 keV γ-rays. Kaplan reported about many heavy concretes studies in his book. Kitis et al. studied heavy concretes including barite aggregates for cyclotron shielding. Mollah et al. determined concretes including ilmenite and magnetite aggregates for neutron shielding by using {sup 252}Cf radioactive source and BF{sub 3} neutron detector. Yarar and Bayuelken studied concretes including colemanite aggregates for neutron shielding. In this paper, we have measured radiation transmission of thirteen different heavy concretes produced by using barite, colemanite and normal aggregates for 276, 303, 356 and 383 keV γ-ray energies of {sup 133}Ba radioactive isotope by using CdTe semiconductor detector and calculated linear and mass attenuation coefficients. Results were compared to X-ray mass attenuation coefficient values of NIST. The attenuation of γ-ray photons is governed primarily by the atomic number and density of the concrete as a shielding material. Photon attenuation depends on pair production, photoelectric effect and Compton scattering. In this study, linear attenuation coefficients (μ) decrease with the increasing the photon energy for these concretes. Heavy elements there is a fairly sharp minimum in the absorption cross section at about this energy region. It is indicated that attenuation coefficient is useful parameter for radiation shielding. As known, the linear attenuation coefficients of the concretes used in this study at these γ-ray energies are not available in the literature by using CdTe semiconductor detectors. The data shows the effects of including boron-rich colemanite or barium-rich barite in addition to normal aggregate in the concrete mixtures. As would be expected, the barite is desirable for photon attenuation, while the colemanite is desirable for neutron attenuation. The concretes including barite and colemanite would be preferred as materials for building construction of radiation oncology departments, radiology departments, nuclear reactors and radiation research laboratories against photon and neutron particle radiations. But other aggregate properties of colemanite such as abrasion resistance and freeze-thaw durability are also found to be important for concrete but they cannot be quantified at this study. (authors)

36 MATERIALS SCIENCE↗

Estimated External Doses to Members of the Public from Patients with {sup 131}I Treatment - Paper 143

To protect individuals from the radiation emitted by a patient receiving {sup 131}I treatment a licensee must estimate the maximum likely effective dose to members of the public. Under current guidance by the United States Nuclear Regulatory Commission (NRC), a licensee may authorize the release of the patient if the effective dose is unlikely to exceed 5 mSv. NRC provides guidance to its licensees, in NRC Regulatory Guide 8.39, on acceptable methods that may be used to calculate the dose to a member of the public that may result from releasing the patient. To further assist licensees in implementing the regulation, NRC used conservative assumptions to estimate the activity of radionuclide in a patient, and the dose rate at 1 meter from the patient, that would be indicators of a potential dose to a member of the public of 5 mSv. Licensees may use these tables as operational criteria for releasing a patient if the conservative assumptions are considered acceptable. Licensees may also perform their own calculations, using case-specific assumptions, to show compliance with 5 mSv release criterion. The scope of this work is to provide dose coefficients for a variety of plausible public exposure scenarios that could be used by licensees to to show compliance. In the patient-specific calculations, the licensee is free to consider factors such as occupancy factor, effective half-life of the radionuclide in the patient's body, and tissue shielding. A conservative method of calculating the maximum likely dose to members of the public is provided in NRC Reg. Guide 8.39, which assumes no tissue attenuation of by the patient's body, no biological component that reduces the effective half-life of the radionuclide, and the patient's body burden is a point source. The assumption of no biological removal from the body introduces some conservatism into dose estimates for {sup 131}I. Also, it has been shown that the assumption of a point source with no tissue attenuation substantially overestimates the dose rate to nearby persons. The current method for calculating the maximum dose rate to members of the public from a nuclear medicine patient provided in US-NRC Regulatory Guide 8.39 assumes the patient's body burden is a point-source. Lack of consideration of tissue attenuation by the patient's body and biological removal of the radionuclide leads to a substantial overestimate of the actual external dose rate to a nearby member of the public. However, use of these assumptions in estimating potential dose to a member of the public simplifies the calculations considerably and, although generally conservative, the calculations serve as a useful screening tool. Many, if not most patients, could be released on that basis. If not, then refined calculations may be used, and the coefficients described in this paper provide one of the means for refining the calculations in cases where the screening calculations were not adequate. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Photon Organ and Effective Dose Coefficients for Cranial and Caudal Irradiation Geometries - Paper 148

With the introduction of new recommendations of the ICRP in Publication 103 the methodology for determining the protection quantity effective dose has been modified. The modifications include changes in organ/tissue weighting factors as well as some changes in radiation weighting factors. Computations of protection dose coefficients now require the use of reference male and female voxel phantoms, see ICRP Publication 110. Computations of equivalent doses in organs and tissues are now performed in each phantom and the average is used to compute the effective dose. The latest set of external dose coefficients using the new reference phantoms and the latest guidance from the ICRP were performed by the ICRP DOCAL task group and reported in ICRP Publication 116, the revision of ICRP Publication 74 and ICRU Report 57. The coefficients were determined for the following irradiation geometries: anterior-posterior (AP), posterior-anterior (PA), right and left lateral (RLAT and LLAT), rotational (ROT), and isotropic (ISO). For all geometries, except the ISO geometry, parallel beams are used to compute the dose coefficients. In this paper, the methodology of ICRP Publication 116 was used to compute dose coefficients for photons for irradiations of the body with parallel beams directed upward from below the feet (caudal) and directed downward from above the head (cranial). These geometries may be encountered in the workplace for personnel standing on contaminated surfaces or volumes and from overhead sources. In this work calculations of organ and tissue kerma and absorbed doses for caudal and cranial exposures to photons ranging in energy from 10 keV to 10 GeV have been performed using the MCNP6.1 radiation transport code and the adult reference phantoms of ICRP Publication 110. Dose coefficients for caudal and cranial irradiation geometries have been calculated in accordance with ICRP Publication 103. The coefficients differ significantly from AP values for both organ and tissues of ICRP Publication 116, as would be expected. For workers in these scenarios organ and effective doses can differ significantly from AP values. For common photon energies (i.e. 100 keV to a few MeV) the AP effective dose overestimates the caudal and cranial values by about a factor of ten. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗