Search NASA⌕ Search

SEARCH · Search NASA

Results for “Position Sensitive Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Poster — Thur Eve — 07: Simultaneous reconstruction of both true and scattered coincidences using a Generalized Scatter reconstruction algorithm in PET

Introduction: Scattered coincidences in PET are generally taken as noise, which reduces image contrast and compromises quantification. We have developed a method, with promising results, to reconstruct activity distribution from scattered PET events instead of simply correcting for them. The implementation of this method on clinical PET scanners is however limited by the currently available detector energy resolution. With low energy resolution we lose the ability to distinguish scattered coincidences from true events based on the measured photon energy. In addition the two circular arcs used to confine the source position for a scattered event cannot be accurately defined. Method: This paper presents a modification to this approach which accounts for limited energy resolution. A measured event is split into a true and a scattered component each with different probabilities based on the position of the pair of photon energies in the energy spectrum. For the scattered component, we model the photon energy with a Gaussian distribution and the upper and lower energy limits can be estimated and used to define inner and outer circular arcs to confine the source position. The true and scattered components for each measured event were reconstructed using our Generalized Scatter reconstruction algorithm. Results and Conclusion: The results show that the contrast and noise properties were improved by 6–9% and 2–4% respectively. This demonstrates that the performance of the algorithm is less sensitive to the energy resolution and that incorporating scattered photons into reconstruction brings more benefits than simply rejecting them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of model Titan atmospheric components using ion mobility spectrometry

The Gas Chromatograph-Ion Mobility Spectrometer (GC-IMS) was proposed as an analytical technique for the analysis of Titan's atmosphere during the Cassini Mission. The IMS is an atmospheric pressure, chemical detector that produces an identifying spectrum of each chemical species measured. When the IMS is combined with a GC as a GC-IMS, the GC is used to separate the sample into its individual components, or perhaps small groups of components. The IMS is then used to detect, quantify, and identify each sample component. Conventional IMS detection and identification of sample components depends upon a source of energetic radiation, such as beta radiation, which ionizes the atmospheric pressure host gas. This primary ionization initiates a sequence of ion-molecule reactions leading to the formation of sufficiently energetic positive or negative ions, which in turn ionize most constituents in the sample. In conventional IMS, this reaction sequence is dominated by the water cluster ion. However, many of the light hydrocarbons expected in Titan's atmosphere cannot be analyzed by IMS using this mechanism at the concentrations expected. Research at NASA Ames and PCP Inc., has demonstrated IMS analysis of expected Titan atmospheric components, including saturated aliphatic hydrocarbons, using two alternate sample ionizations mechanisms. The sensitivity of the IMS to hydrocarbons such as propane and butane was increased by several orders of magnitude. Both ultra dry (waterless) IMS sample ionization and metastable ionization were successfully used to analyze a model Titan atmospheric gas mixture.

Kojiro, D. R.↗

Pulsed, gridded electron reversal ionizer

The design and performance of a new-type source of negative ions is presented. This device retains the idea of the so-called reversal electron attachment detector to produce low-energy electrons by reversing electron trajectories at an electrode. Electrons are produced in the present device by several ribbon filaments that surround a cylindrical wire grid. They are accelerated through the grid, then decelerated to zero or near-zero velocity at the surface of a tube. The tube (anode) is perforated with small holes through which effuse the target molecules. Electrons attach to form either parent and/or fragment negative ions. Attachment takes place at a location above the anode corresponding to a match between the electron energy and the attachment resonance energy. Negative ions are pulsed out of the attachment region and focused onto the entrance plane of a quadrupole mass selector. Electron and ion trajectory calculations are presented and the performance illustrated with six molecules having attachment resonances in the range 0.0-2.2 eV. The detection sensitivity is below 1 part-per-trillion, with a calculated conversion rate of 1.3 percent. Signal nonlinearity is discussed in terms of ion space-charge effects. The device also produces positive ions, and an analogous treatment may be carried through to characterize its performance in this mode.

Boumsellek, S.↗

Calibration of the sub-aperture backscatter system on OMEGA EP

The sub-aperture backscatter (SABS) diagnostic on the OMEGA EP Laser System is a diagnostic that is used to measure the backscattered and sidescattered light during laser–plasma interaction experiments that are relevant to high-energy-density physics and inertial confinement fusion. The diagnostic collects stimulated Brillouin scattering (SBS) UV light at around 351 nm and stimulated Raman scattering (SRS) in the visible-light regime in the 420–720-nm-wavelength range and provides spectrally and temporally resolved information. Five 1-in. light collectors, composed of a lens, ground glass diffuser, and coupling into a 300-μm fiber, are positioned behind the last steering mirror on one of the four beamlines to catch a portion of the beam cross section (~1.5%) of the emission that is scattered into the beamline. The SRS light is collected in two light collectors, combined, and transported via graded index fibers to a streaked spectrometer. The SABS-SRS streak spectrometer has a temporal and spectral resolution of 100 ps and 1 nm, respectively. Three other light collectors collect, combine, and transport the SBS signal to a Hamamatsu high-voltage photodiode, where an oscilloscope digitizes the data, providing a time resolution of better than 1 ns. To obtain an absolute energy calibration of SRS measurements, light signals of known energy and wavelength were injected into the light collectors one at a time. The resulting counts on the streak camera charge-coupled device for SRS are then correlated with the incident fluence of scattered light at the light collector in order to allow a quantitative assessment of streak camera sensitivity to determine the energy of the scattered light during experiments. The measurements were performed in situ from the light collectors to the detectors. Other offline measurements provided the transmission of the optics between the target chamber center and the light collectors.

47 OTHER INSTRUMENTATION↗

ROSAT observations of the unusual supernova remnant CTB 80 containing the pulsar PSR 1951 + 32

The unusal supernova remnant CTB, 80 containing the 39.5 ms pulsar PSR 1951 + 32, has been observed with the Position Sensitive Proportional Counter (PSPC) and the High Resolution Imager (HRI) aboard ROSAT. The HRI image, centered on the pulsar, is composed of a bright compact core of approximately 1 arcminute radius containing the pulsar and a compact nebula, as well as a diffuse nebula extending approximately 5 arcminutes eastward of the pulsar. The PSPC allowed us to model the spectra of the point source, the compact nebula and the 5 arcminute diffuse nebula. For a power-law spectrum with photon index Gamma approximately 2 and an interstellar column density of N(sub H) approximately 3 x 10(exp 21)/cm(exp 21) the derived luminosities are approximately 2.3 x 10(exp 33) d(sub 2.5)(exp 2) ergs/s from the pointlike source, approximately 3.9 x 10(exp 33) d(sup 2.5)(exp 2) ergs/s from the compact nebula, and approximately 1.8 x 10(exp 33) d(sub 2.5)(exp 2) ergs/s from the 5 arcminutes diffuse nebula. In addition, the 2 deg diameter circular field of view of the PSPC reveals a hard emission feature southeast of the pulsar with a conical geometry extending out to the edge of the detector. The spectrum from this region is well described by a two-temperature Raymond-Smith thermal plasma with an average temperature of approximately 10(exp 7) K and a luminosity of approximately 10(exp 34)d(sub 2.5)(exp 2) ergs/s. Pulsations from the 39.5 ms puslar, PSR 1951 + 32, are detected at the 99% confidence level. The implied pulsed fration is approximately 35% with a complicated energy-dependent behavior. The compact core and the extended diffuse nebula can be explained as synchrotron radiation from the relativistic pulsar wind confined by the ram pressure of the surrounding inhomgeneous medium. The conelike feature detected southeast of PSR 1951 + 32 is consistent with emission from an optically thin SNR in the radiative cooling phase of its evolution.

Safi-Harb, Samar↗

Establishing a Pure Sample of Side-Piercing Through-Going Cosmic-Ray Muons for LArTPC Calibration in MicroBooNE

Measuring detector properties and performing calibrations of a near-surface Liquid Argon Time Projection Chamber (LArTPC) require large samples of well-reconstructed tracks. Cosmic-ray muon tracks are an ideal calibration source for a surface TPC for these purposes, because they cover the detector volume roughly uniformly and enter the detector volume at a high rate. In order to calibrate the TPC’s position response, the reconstructed track for the 3D trajectory of each cosmic-ray muon must be available. Because of the slow electron drift velocity, reconstructed track information along the drift-coordinate is offset with respect to the true energy deposition location. This offset can be corrected only if the time at which the track enters the detector volume (t 0 ) is also reconstructed. In this note we present a method developed for reconstructing track t 0 for the subset of cosmic-ray tracks which hit either the TPC anode-plane or cathode-plane and are through-going. Over 97% of the t 0 -tagged tracks have their t 0 correctly reconstructed in both simuation in cosmic-ray data while maintaining yield values of 0.9 tracks per 4.8 ms exposure for cathode-piercing tracks and 1.7 tracks per 4.8 ms exposure for anode-piercing tracks in simulation. Coverage maps for an off-beam cosmicray data sample of t 0 -tagged tracks produced with this method show that t 0 -tagged track coverage is as expected given cosmic track geometries in the TPC, acceptance effects, and cut sensitivities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for Heavy Neutral Leptons at the MINER$\nu$A detector

Heavy Neutral Leptons (HNL) are particles hypothesised to provide a mass generation mechanism for the active (observed) neutrino species, which are known to have nonzero mass from the definitive observation of neutrino oscillations. HNL are eigenstates of mass of the order $\mathcal{O}(0.1 − 1\,\,\mathrm{GeV}/c^{2})$, which mix into the active flavour eigenstates through the extended leptonic mixing matrix. Apart from neutrino mass, they could provide a natural dark matter candidate and a mechanism for matter-antimatter asymmetry in the early Universe, giving rise to today’s matter-dominated cosmos. Searches for HNL typically attempt to either confirm the existence of HNL through an excess in data that is most compatible with an HNL hypothesis, or by setting limits on the HNL parameter space $\left(M_{N4}, \left|U_{\alpha 4}\right|^{2}\right)$ in the case of statistically insignificant excess. Such searches are intensifying as part of a global research programme at both colliders and accelerator / atmospheric neutrino experiments. One such setting is the MINER$\nu$A experiment, located in the NuMI beamline at Fermilab. MINER$\nu$A has collected a large amount of data over seven years of operation to measure the cross-sections of neutrino-nucleus interactions necessary to drive systematic uncertainties down, in order for neutrino oscillation experiments to achieve sensitivity to CP violation in the neutrino sector. With the high-energy, high-intensity NuMI beam, and with good timing, position, and angular resolution leading to sensitivity to HNL decays, MINER$\nu$A is fertile ground for an HNL search, which is performed in this thesis. Specifically, a novel, experiment-agnostic and general simulation of HNL production and decay is presented and deployed; this simulation has been incorporated in the ubiquitous GENIE neutrino event generator for use with neutrino experiments in the future. The event selection and background characterisation is discussed in detail, including the primary background coming from charged-current coherent and diffractive pion production from neutrino-nucleus interactions, and constraints on the background using control regions from MINER$\nu$A data are derived. Finally, by means of a fake-data study given a background of $\mathcal{O}(500)$ events, the discovery potential and limit-setting capacity of MINER$\nu$A is demonstrated, and ways to improve this capacity are expounded upon.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TH-AB-201-07: Filmless Treatment Localization QA for the CyberKnife System

Purpose: Accuray recommends daily evaluation of the treatment localization and delivery systems (TLS/TDS) of the CyberKnife. The vendor-provided solution is a Winston-Lutz-type test that evaluates film shadows from an orthogonal beam pair (known as AQA). Since film-based techniques are inherently inefficient and potentially inconsistent and uncertain, this study explores a method which provides a comparable test with greater efficiency, consistency, and certainty. This test uses the QAStereoChecker (QASC, Standard Imaging, Inc., Middleton, WI), a high-resolution flat-panel detector with coupled fiducial markers for automated alignment. Fiducial tracking is used to achieve high translational and rotational position accuracy. Methods: A plan is generated delivering five circular beams, with varying orientation and angular incidence. Several numeric quantities are calculated for each beam: eccentricity, centroid location, area, major-axis length, minor-axis length, and orientation angle. Baseline values were acquired and repeatability of baselines analyzed. Next, errors were induced in the path calibration of the CK, and the test repeated. A correlative study was performed between the induced errors and quantities measured using the QASC. Based on vendor recommendations, this test should be able to detect a TLS/TDS offset of 0.5mm. Results: Centroid shifts correlated well with induced plane-perpendicular offsets (p < 0.01). Induced vertical shifts correlated best with the absolute average deviation of eccentricities (p < 0.05). The values of these metrics which correlated with the threshold of 0.5mm induced deviation were used as individual pass/fail criteria. These were then used to evaluate induced offsets which shifted the CK in all axes (a clinically-realistic offset), with a total offset of 0.5mm. This test provided high and specificity and sensitivity. Conclusion: From setup to analysis, this filmless TLS/TDS test requires 4 minutes, as opposed to 15–20 minutes for film-based methods. The techniques introduced can potentially isolate errors in individual joints of the CK robot. Spectrum Medical Physics, LLC of Greenville, SC has a consulting contract with Standard Imaging of Middleton, WI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring Electron Diffusion and Constraining the Neutral Current $\pi^0$ Background for Single-Photon Events in MicroBooNE

Liquid Argon Time Projection Chambers (LArTPCs) are a rising technology in the field of experimental neutrino physics. LArTPCs use ionization electrons and scintillation light to reconstruct neutrino interactions with exceptional calorimetric and position resolution capabilities. Here, I present two analyses conducted in the MicroBooNE LArTPC at Fermilab: a measurement of the longitudinal electron diffusion coefficient, $D_L$, in the MicroBooNE detector and a constraint of the systematic uncertainty on MicroBooNE's single-photon analysis due to the dominant neutral current (NC) \piz{} background. Longitudinal electron diffusion modifies the spatial and timing resolution of the detector, and measuring it will help correct for these effects. Furthermore, current measurements of $D_L$ in liquid argon are sparse and in tension with one another, making the MicroBooNE measurement especially valuable. We report a measurement of $3.74^{+0.28}_{-0.29}$ cm$^2$/s. MicroBooNE is searchin g for si ngle-photon events as a potential explanation for the MiniBooNE low-energy excess (LEE) of electron neutrino-like events, which has been interpreted as evidence for low-mass sterile neutrinos. However, this search is overwhelmed by a large NC \piz{} background. By performing a sideband selection of NC \piz{} events, we apply a data-driven rate constraint to the single-photon analysis to reduce the systematic uncertainties. At present, this constraint improves the single-photon analysis' median sensitivity to the LEE-like signal from 0.9$\sigma$ to $1.5\sigma$. This sensitivity is expected to improve significantly as more data become available. Both of these measurements will not only benefit MicroBooNE, but also inform future LArTPC experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Toward complete spectroscopy using β decay: The example of Cl 32 ( β γ ) S 32

$^{32}\textbf{Cl}$ is a neutron-deficient isotope with a $β$-decay half-life of 298 ms and a spin and parity of $J^π=1^+$. Previous measurements of $^{32}\textbf{Cl}$ $β$-delayed $γ$ rays have yielded a $β$-decay scheme with twelve $β$-decay transitions, contributing to studies of nuclear structure and fundamental symmetries. Those experiments have been limited to the observation of $^{32}\textbf{S}$ states with $J^π = 0^+,1^+, 2^+$. Our goal is to search for new $β$-delayed $γ$ rays and $β$-decay transitions of $^{32}\textbf{Cl}$ to $^{32}\textbf{S}$. A measurement of $^{32}\textbf{Cl}$ $β$-delayed $γ$ decay has been performed using the Clovershare array of high-purity germanium detectors at the National Superconducting Cyclotron Laboratory. By acquiring the highest-statistics $^{32}\textbf{Cl}$ $β$-delayed $γ$-ray spectrum to date and exploiting a new sensitivity to $γ-γ$ coincidences, this experiment has enabled the observation of nine previously unobserved $β$-delayed $γ$-ray transitions, leading to the inference of five $β$-decay transitions never before observed in $^{32}\textbf{Cl}$ $β$-delayed $γ$ decay. The set of observed states includes negative-parity states for the first time. By combining the new information with data from previous work, the lifetimes and partial widths of the 8861- and 9650-keV states of $^{32}\textbf{S}$ have been determined. In addition, the $^{31}\textbf{P}$($p,α$)$^{28}\textbf{Si}$ resonance strength of the 9650-keV state has been limited to $ωγ<9.8$ meV, which is an improvement over direct measurements. An enhanced decay scheme has been constructed. Most of the excited bound $^{32}\textbf{S}$ states that would correspond to allowed and first-forbidden $β$-decay transitions have been observed, demonstrating the potential of $β$-decay experiments to approach complete spectroscopy measurements at the next generation of radioactive beam facilities. The observed positive-parity levels are well matched by $sd$ shell-model calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhancing the quality of radiographic images acquired with point-like gamma-ray sources through correction of the beam divergence and attenuation

Radiographic images acquired with point-like gamma-ray sources exhibit a desirable low penumbra effects specially when positioned far away from the set object-detector. Such an arrangement frequently is not affordable due to the limited flux provided by a distant source. A closer source, however, has two main drawbacks, namely the degradation of the spatial resolution - as actual sources are only approximately punctual - and the non-homogeneity of the beam hitting the detector, which creates a false attenuation map of the object being inspected. This non-homogeneity is caused by the beam divergence itself and by the different thicknesses traversed the beam even if the object were an homogeneous flat plate. In this work, radiographic images of objects with different geometries, such as flat plates and pipes have undergone a correction of beam divergence and attenuation addressing the experimental verification of the capability and soundness of an algorithm formerly developed to generate and process synthetic images. The impact of other parameters, including source-detector gap, attenuation coefficient, ratio defective-to-main hull thickness and counting statistics have been assessed for specifically tailored test-objects aiming at the evaluation of the ability of the proposed method to deal with different boundary conditions. All experiments have been carried out with an X-ray sensitive Imaging Plate and reactor-produced {sup 198}Au and {sup 165}Dy sources. The results have been compared with other technique showing a better capability to correct the attenuation map of inspected objects unveiling their inner structure otherwise concealed by the poor contrast caused by the beam divergence and attenuation, in particular for those regions far apart from the vertical of the source.

07 ISOTOPE AND RADIATION SOURCES↗

Microstructural and Micro-Chemical Evolutions in the Irradiated UCO Fuel Kernels of AGR-1 and AGR-2 TRISO Fuel Particles

AGR-1 and AGR-2 TRISO fuel particles were fabricated with slightly different fuel kernel chemical compositions, modified fabrication processes, different fuel kernel diameters, and changed 235U enrichments. To correlate those differences with the fuel kernel responses to neutron irradiations in terms of irradiated fuel microstructure, fission products chemical and physical states, and fission gas bubble evolutions, extensive microstructural and analytical characterizations were conducted. The studies used a state of art transmission electron microscopy (TEM) equipped with Energy-dispersive X-ray spectroscopy (EDS) of four silicon solid-state detectors which have super sensitivity and fast speed. The TEM specimens were prepared from selected AGR-1 and AGR-2 irradiated fuel kernels exposed to safety testing after irradiation. The particles were chosen to represent a representative irradiation conditions with a fuel burnup within the range from 10.8 to 18.6% FIMA, and the time-average volume-average temperatures vary from 1070 to 1287°C. The 235U enrichment was 19.74 wt.% for the AGR1 fuel kernels and 14.03 wt.% for the AGR-2 fuel kernels. The TEM results show that there were significant microstructural reconstructions in the irradiated fuel kernels for both the AGR-1 and AGR-2 fuels. There are four major phases including fuel matrix of UO2 and UC, U2RuC2, and UMoC2 in the irradiated AGR2 fuel kernel. Zr and Nb form solid solution in the UC phase. UMoC2 phase often shows a detectable concentration of Tc. Pd was found to mainly locate in the buffer layer or to be associated with fission gas bubble within the UMoC2 phase. The EDS maps qualitatively show that the rare-earth fission products (Nb, et al.) preferentially reside in the UO2 phase. In contrast, in the irradiated AGR1 fuel kernel, no U2RuC2 or UMoC2 precipitates were positively identified. Instead, there is a high number of rod-shape precipitates enriched with Ru, Tc, Rh, and Pd observed in the fuel kernel center and edge zone. The difference of microstructural and micro-chemical evolutions in irradiated fuel kernels between the AGR-1 and AGR-2 TRISO fuel particle may result from a combined factor of irradiation temperature, fuel geometry and chemical composition. However, the irradiation temperature probably play a more deterministic role. Limited electron energy loss spectroscopy (EELS) characterizations on the AGR2 fuel kernel show that there is nearly no carbon in the UO2 phase while a small fraction of oxygen was detected in the UC/UMoC2 phase.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Induced Magnetic Fields in LBNF Horns and DUNE-PRISM Off-Axis Neutrinos

Deep Underground Neutrino Experiment (DUNE) is a next-generation, long-baseline neutrino oscillation experiment that will utilize an intense neutrino beam from Fermilab to measure neutrino oscillation parameters with unprecedented precision. The DUNE-PRISM near detector concept employs an off-axis measurement strategy to mitigate neutrino-nucleus interaction uncertainties; however, this approach relies critically on the accurate characterization of the neutrino flux. As statistical uncertainties are suppressed in the high-intensity Long Baseline Neutrino Facility (LBNF) beam, beamline focusing uncertainties, specifically those arising from focusing horn geometry, become an important systematic uncertainty source. This work presents Geant4 LBNF beam simulations quantifying one of the most important systematic uncertainties for off-axis fluxes: the impact of manufacturing tolerances in the LBNF horns. The focusing horns consist of coaxial inner and outer conductors. Ideally, the region inside the inner conductor is field-free, while the region between the inner and outer conductors serves as the focusing region, where the magnetic field follows a nominal $1/r$ dependence. However, inner conductor deformations such as eccentricity and ellipticity introduce asymmetry, inducing unintended magnetic fields inside the field-free region. Crucially, while the on-axis neutrino flux remains largely unaffected by these induced fields, the resulting flux fractional shifts become pronounced over a particular range of off-axis positions where the DUNE-PRISM program will perform measurements. Consequently, these inner conductor deformations can impact the precision of flux predictions, which could potentially degrade the sensitivity to oscillation parameters. Possible mitigation strategies for these effects will also be presented.

Bae, Yuri [U. Minnesota, Minneapolis (main)] (ORCI↗

Cadmium zinc telluride based infrared interferometry for X-ray detection

Cadmium Zinc Telluride (CZT) is a wide band gap semiconductor for room temperature radiation detection. The electro-optic Pockels effect of the material has been exploited in the past to study electric field non-uniformities and their consequence on conventional detector signals in CZT, by imaging the intensity distribution of infrared (IR) light transmitted through a device placed between crossed polarizers. Recently, quantitative monitoring of extremely high intensity neutron pulses through the change of transmitted IR intensity was demonstrated, offering the advantage to place sensitive electronics outside the measured radiation field. In this work, we demonstrate that X-ray intensity can be deduced directly from measuring the change in phase of 1550 nm laser light transmitted through a 7 × 7 × 2 mm{sup 3} CZT based Pockels cell in a simple Mach Zehnder interferometer. X-rays produced by a 50 kVp Mo X-ray tube incident on the CZT cathode surface placed at 7 mm distance cause a linearly increasing phase shift above 0.3 mA tube current, with 1.58 ± 0.02 rad per mA for an applied bias of 500 V across the 2 mm thick device. Pockels images confirm that the sample properties are in agreement with the literature, exhibiting electric field enhancement near the cathode under irradiation, which may cause the non-linearity at low X-ray tube anode current settings. The laser used to probe the X-ray intensity causes itself some space charge, whose spatial distribution does not seem to be exclusively determined by the incident laser position, i.e., charge carrier generation location, with respect to the electrodes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low-energy Electron-track Imaging for a Liquid Argon Time-projection-chamber Telescope Concept Using Probabilistic Deep Learning

The GammaTPC is an MeV-scale single-phase liquid argon time-projection-chamber gamma-ray telescope concept with a novel dual-scale pixel-based charge-readout system. It promises to enable a significant improvement in sensitivity to MeV-scale gamma rays over previous telescopes. The novel pixel-based charge readout allows for imaging of the tracks of electrons scattered by Compton interactions of incident gamma rays. The two primary contributors to the accuracy of a Compton telescope in reconstructing an incident gamma-ray’s original direction are its energy and position resolution. In this work, we focus on using deep learning to optimize the reconstruction of the initial position and direction of electrons scattered in Compton interactions, including using probabilistic models to estimate predictive uncertainty. We show that the deep-learning models are able to predict locations of Compton scatters of MeV-scale gamma rays from simulated 500 μm pixel-based data to better than 1 mm rms error and are sensitive to the initial direction of the scattered electron. We compare and contrast different deep-learning uncertainty estimation algorithms for reconstruction applications. Additionally, we show that event-by-event estimates of the uncertainty of the locations of the Compton scatters can be used to select those events that were reconstructed most accurately, leading to improvement in locating the origin of gamma-ray sources on the sky.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance Study of an aSi Flat Panel Detector for Fast Neutron Imaging of Nuclear Waste

Radioactive waste must be characterized to check its conformance for intermediate storage and final disposal according to national regulations. For the determination of radio-toxic and chemo-toxic contents of radioactive waste packages non-destructive analytical techniques are preferentially used. Fast neutron imaging is a promising technique to assay large and dense items providing, in complementarity to photon imaging, additional information on the presence of structures in radioactive waste packages. Therefore the feasibility of a compact Neutron Imaging System for Radioactive waste Analysis (NISRA) using 14 MeV neutrons is studied in a cooperation framework of Forschungszentrum Juelich GmbH, RWTH Aachen University and Siemens AG. However due to the low neutron emission of neutron generators in comparison to research reactors the challenging task resides in the development of an imaging detector with a high efficiency, a low sensitivity to gamma radiation and a resolution sufficient for the purpose. The setup is composed of a commercial D-T neutron generator (Genie16GT, Sodern) with a surrounding shielding made of polyethylene, which acts as a collimator and an amorphous silicon flat panel detector (aSi, 40 x 40 cm{sup 2}, XRD-1642, Perkin Elmer). Neutron detection is achieved using a general propose plastic scintillator (EJ-260, Eljen Technology) linked to the detector. The thermal noise of the photodiodes is reduced by employing an entrance window made of aluminium. Optimal gain and integration time for data acquisition are set by measuring the response of the detector to the radiation of a 500 MBq {sup 241}Am-source. Detector performance was studied by recording neutron radiography images of materials with various, but well known, chemical compositions, densities and dimensions (Al, C, Fe, Pb, W, concrete, polyethylene, 5 x 8 x 10 cm{sup 3}). To simulate gamma-ray emitting waste radiographs in presence of a gamma-ray sources ({sup 60}Co, {sup 137}Cs, {sup 241}Am) were performed. A homemade algorithm was developed to determine a value which is related to the neutron absorption of the sample with the analysis of the raw detector data. The detector was placed 42 cm away from the neutron source. Distance between detector and the samples was 0.5 cm. At the sample position the fast neutron flux was estimated to 9x10{sup 3} n cm{sup -2} s{sup -1} for a neutron emission of 10{sup 8} n s{sup -1}. The acquisition time was 15 minutes. First neutron radiographs were successfully recorded despite the low detector efficiency and low neutron emission. Analysis of the data shows a correlation between the measured signal and determined neutron absorption. Thus discrimination between different materials of same thicknesses may be achieved. The measurements and results will be presented and discussed in details.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Spectral Energy Distribution of Fermi Bright Blazars

We have conducted a detailed investigation of the broadband spectral properties of the gamma-ray selected blazars of the Fermi LAT Bright AGN Sample (LBAS). By combining our accurately estimated Fermi gamma-ray spectra with Swift, radio, infra-red, optical, and other hard X-ray /gamma-ray data, collected within 3 months of the LBAS data taking period, we were able to assemble high-quality and quasi-simultaneous spectral energy distributions (SED) for 48 LBAS blazars. The SED of these gamma-ray sources is similar to that of blazars discovered at other wavelengths, clearly showing, in the usual log v-log v Fv representation, the typical broadband spectral signatures normally attributed to a combination of low-energy synchrotron radiation followed by inverse Compton emission of one or more components. We have used these SED to characterize the peak intensity of both the low- and the high-energy components. The results have been used to derive empirical relationships that estimate the position of the two peaks from the broadband colors (i.e., the radio to optical, alpha(sub ro) , and optical to X-ray, alpha(sub ox), spectral slopes) and from the gamma-ray spectral index. Our data show that the synchrotron peak frequency (v(sup S) (sub peak)) is positioned between 10(exp 12.5) and 10(exp 14) Hz in broad-lined flat spectrum radio quasars (FSRQs) and between 10(exp 13) and 10(exp 17) Hz in featureless BL Lacertae objects. We find that the gamma-ray spectral slope is strongly correlated with the synchrotron peak energy and with the X-ray spectral index, as expected at first order in synchrotron-inverse Compton scenarios. However, simple homogeneous, one-zone, synchrotron self-Compton (SSC) models cannot explain most of our SED, especially in the case of FSRQs and low energy peaked (LBL) BL Lacs. More complex models involving external Compton radiation or multiple SSC components are required to reproduce the overall SED and the observed spectral variability. While more than 50% of known radio bright high energy peaked (HBL) BL Lacs are detected in the LBAS sample, only less than 13% of known bright FSRQs and LBL BL Lacs are included. This suggests that the latter sources, as a class, may be much fainter gamma-ray emitters than LBAS blazars, and could in fact radiate close to the expectations of simple SSC models. We categorized all our sources according to a new physical classification scheme based on the generally accepted paradigm for Active Galactic Nuclei and on the results of this SED study. Since the LAT detector is more sensitive to flat spectrum gamma-ray sources, the correlation between v(sup S) (sub peak) and gamma-ray spectral index strongly favors the detection of high energy peaked blazars, thus explaining the Fermi overabundance of this type of sources compared to radio and EGRET samples. This selection effect is similar to that experienced in the soft X-ray band where HBL BL Lacs are the dominant type of blazars.

Abdo, A. A.↗

Large Area Picosecond Photodetector (LAPPD TM ) - Pilot production and development status

Here, we discuss performance results achieved for fully functional sealed Large Area Picosecond Photodetectors (LAPPD (TM)) in tests performed at Incom Inc., as well as independent test results reported by our early adopters. The LAPPD is a microchannel plate (MCP) based large area picosecond photodetector, capable of imaging with single-photon sensitivity at high spatial and temporal resolutions in a hermetic package. The LAPPD has an active area of 350 square centimeters in an all-glass hermetic package with a fused silica window and bottom plate and sidewalls made of borosilicate float glass. Signals are generated by a bi-alkali Na 2 KSb photocathode and amplified with a stacked chevron pair of MCPs produced by applying resistive and emissive atomic layer deposition coatings to glass capillary array (GCA) substrates. Signals are collected on RF stripline anodes applied to the bottom plates which exit the detector via pin-free hermetic seals under the side walls. LAPPD test and performance results for product produced and delivered to early adopter customers during the first half of 2018 are reviewed. These results include electron gains ≥ 7.5 x 10 6 @ 850/950 V (entry/exit MCP), low dark noise rates (22 Cts/s/cm 2 ), single photoelectron (PE) timing resolution of 64 picoseconds RMS, and single photoelectron spatial resolution along and across strips of 2.8 mm and 1.3 mm RMS respectively. Many of these devices also had very high QE photocathodes that were uniform over the full 195 mm x 195 mm window active area (LAPPD #15 QE% @ 365 nm Max/Avg/Min = 25.8/22.3 ± 3/15.7). An update is additionally provided of developments that enable capacitive signal coupling from the detector to application specific pads or stripline readout patterns deployed on printed circuit boards positioned beneath the file, outside of the vacuum package. We conclude with examples of how sensors offering picosecond timing, in diverse applications can bring transformative change to detector technology and applications in future experiments.

47 OTHER INSTRUMENTATION↗