Advanced Power Measurement and Control for the Trinity Supercomputer.
Abstract not provided.
Design and Validation of Advanced Controls for Networked Power Systems.
Abstract not provided.
Overview of Sensors and Controls Research for Power Generation at the NETL Research & Innovation Center
Presented by NETL at ISA Power Industry Division Symposium, 06/17
Grid Voltage Control Analysis for Heavy-Duty Electric Vehicle Charging Stations: Preprint
This paper presents an analysis of voltage control strategies for heavy duty electric vehicle (EV) charging stations. The performance of three voltage control approaches including power factor control, preset volt-var curve control, and customized volt-var curve control, have been investigated and evaluated for three different sizes of charging stations, including single-port small charging station, three-port middle size charging station, and 6-port travel center. The charging stations have been placed on various locations of four different types of distribution systems, to obtain a comprehensive performance analysis of the three voltage control approaches under different scenarios. To quantitively compare the performance of the three voltage control approaches, a series of metrics have been designed to quantify the performance and contribute to the comprehensive analysis summary.
Distributed control of electric power grids
A method for determining power output levels of a plurality of nodes in an electric power system includes receiving, at a first node of the plurality of nodes, voltage information and multipliers of all neighboring nodes of the first node within the electric power system, determining, by the first node, a local power generation and a local voltage using the voltage information and the multipliers of the neighboring nodes and distributing the local power generation and the local voltage to the neighboring nodes, determining, by the first node, an estimated voltage of each of the neighboring nodes and distributing the estimated voltage to each of the neighboring nodes, and updating, by the first node, a local multiplier using the voltage information received from the neighboring nodes and the estimated voltage of each of the neighboring nodes determined by the node.
Enabling Power Measurement and Control on Astra: The First Petascale Arm Supercomputer.
Abstract not provided.
Sensitivity and Importance Measure Analyses for Various Design Architectures for High Safety-Significant Safety-Related Digital Instrumentation and Control Systems of Nuclear Power Plants
A transition from analog instrumentation and control (I&C) technologies to digital I&C technologies is taking place for license renewals of existing nuclear power plants and for operating licenses of new advanced reactors. This transition necessitates research on risk and economic assessments of digital I&C technologies to ensure the long-term safety and reliability of vital systems, reduce uncertainty in licensing costs in addition to timeline, support integration of digital I&C systems in the plant, and find the most efficient technology upgrades. Adding redundancy within systems or components is a common means of improving design safety; however, it can also make designs more prone to common-cause failures (CCFs). Introducing diversity into redundant systems or components is a way to mitigate and possibly eliminate CCFs, but it also increases plant complexity and may be costly. The balance between redundancy and diversity remains a challenge for digital I&C systems. This study performs sensitivity and importance analyses for four design architectures of two digital I&C systems—the reactor-trip system and the engineered safety features actuation system. For each system, two architectures are examined, including a redundant, non-diverse configuration and a redundant, diverse configuration. The sensitivity analysis will provide insights on the impact of introducing diversity to system reliability. The importance results will help identify risk-significant and risk-sensitive components and failure modes, which may be good candidates for future design improvement.
Final Technical Report on Quantifying Dependability Attributes of Software Based Safety Critical Instrumentation and Control Systems in Nuclear Power Plants
With the current transition from analog to digital instrumentation and control systems in nuclear power plants, the number and variety of software-based systems have significantly increased. The sophisticated nature and increasing complexity of software raises trust in these systems as a significant challenge. The trust placed in a software system is typically termed software dependability. Software dependability analysis faces uncommon challenges since software systems’ characteristics differ from those of hardware systems. The lack of systematic science-based methods for quantifying the dependability attributes in software-based instrumentation as well as control systems in safety critical applications has proved itself to be a significant inhibitor to the expanded use of modern digital technology in the nuclear industry. Dependability refers to the ability of a system to deliver a service that can be trusted. Dependability is commonly considered as a general concept that encompasses different attributes, e.g., reliability, safety, security, availability and maintainability. Dependability research has progressed significantly over the last few decades. For example, various assessment models and/or design approaches have been proposed for software reliability, software availability and software maintainability. Advances have also been made to integrate multiple dependability attributes, e.g., integrating security with other dependability attributes, measuring availability and maintainability, modeling reliability and availability, quantifying reliability and security, exploring the dependencies between security and safety and developing integrated analysis models. However, there is still a lack of understanding of the dependencies between various dependability attributes as a whole and of how such dependencies are formed. To address the need for quantification and give a more objective basis to the review process -- therefore reducing regulatory uncertainty -- measures and methods are needed to assess dependability attributes early on, as well as throughout the life-cycle process of software development. In this research, extensive expert opinion elicitation is used to identify the measures and methods for assessing software dependability. Semi-structured questionnaires were designed to elicit expert knowledge. A new notation system, Causal Mechanism Graphing, was developed to extract and represent such knowledge. The Causal Mechanism Graphs were merged, thus, obtaining the consensus knowledge shared by the domain experts. In this report, we focus on how software contributes to dependability. However, software dependability is not discussed separately from the context of systems or socio-technical systems. Specifically, this report focuses on software dependability, reliability, safety, security, availability, and maintainability. Our research was conducted in the sequence of stages found below. Each stage is further examined in its corresponding chapter. Stage 1 (Chapter 2): Elicitation of causal maps describing the dependencies between dependability attributes. These causal maps were constructed using expert opinion elicitation. This chapter describes the expert opinion elicitation process, the questionnaire design, the causal map construction method and the causal maps obtained. Stage 2 (Chapter 3): Elicitation of the causal map describing the occurrence of the event of interest for each dependability attribute. The causal mechanisms for the “event of interest” were extracted for each of the software dependability attributes. The “event of interest” for a dependability attribute is generally considered to be the “attribute failure”, e.g. security failure. The extraction was based on the analysis of expert elicitation results obtained in Stage 1. Stage 3 (Chapter 4): Identification of relevant measurements. Measures for the “events of interest” and their causal mechanisms were obtained from expert opinion elicitation for each of the software dependability attributes. The measures extracted are presented in this chapter. Stage 4 (Chapter 5): Assessment of the coverage of the causal maps via measures. Coverage was assessed to determine whether the measures obtained were sufficient to quantify software dependability, and what measures are further required. Stage 5 (Chapter 6): Identification of “missing” measures and measurement approaches for concepts not covered. New measures, for concepts that had not been covered sufficiently as determined in Stage 4, were identified using supplementary expert opinion elicitation as well as literature reviews. Stage 6 (Chapter 7): Building of a detailed quantification model based on the causal maps and measurements obtained. Ability to derive such a quantification model shows that the causal models and measurements derived from the previous stages (Stage 1 to Stage 5) can form the technical basis for developing dependability quantification models. Scope restrictions have led us to prioritize this demonstration effort. The demonstration was focused on a critical system, i.e. the reactor protection system. For this system, a ranking of the software dependability attributes by nuclear stakeholders was developed. As expected for this application, the stakeholder ranking identified safety as the most critical attribute to be quantified. A safety quantification model limited to the requirements phase of development was built. Two case studies were conducted for verification. A preliminary control gate for software safety for the requirements stage was proposed and applied to the first case study. The control gate allows a cost effective selection of the duration of the requirements phase.
Improved PV System Control Strategies to Reduce Power Management Costs in Nanogrids
An improved PV system control method is proposed to reduce nanogrid operation costs in this paper. A model including it various components such as photovoltaic (PV) systems, energy storage systems (ESSs), gateways, and household loads is considered with the constraints of the ESS, PV irradiance from real data, and household load. We designed an optimal economic dispatch strategy with an improved PV system control method. Combining the proposed optimal economic dispatch and PV system control strategies, it can improve the control performance for both transient and steady-state responses thereby enabling the maximum power to be extracted from the PV. Consequently, the PV power is maximized, which allows the ESS to use less power and sell the surplus to external power sources, which means the proposed method decreases the nanogrid operation costs. Furthermore, this performance is verified via nanogrid simulations and PV experimental kit.
Baseline Human Factors and Ergonomics in Support of Control Room Modernization at Nuclear Power Plants
As part of control room modernization at a nuclear power plant, a utility should carefully follow the four phases prescribed by the U.S. Nuclear Regulatory Commission in NUREG-0711, Human Factors Engineering Program Review Model . These four phases include Planning and Analysis, Design, Verification and Validation, and Implementation and Operation. While NUREG-0711 is a useful guideline, it is written primarily from the perspective of regulatory review, and it therefore does not provide a nuanced account of many of the steps the utility might undertake as part of control room modernization. The guideline is largely summative—meant to catalog final products—rather than formative—meant to guide the overall modernization process. In this report, we highlight two crucial formative subelements of the Planning and Analysis phase specific to control room modernization that are not covered in NUREG-0711. These two subelements are the usability and ergonomics baseline evaluations. A baseline evaluation entails evaluating the system as-built and currently in use. The usability baseline evaluation provides key insights into operator performance using the control system currently in place. The ergonomic baseline evaluation identifies possible deficiencies in the physical configuration of the control system. Both baseline evaluations feed into the design of the replacement system and help ensure that control room modernization represents the successful evolution of the control system.
Improving Transient Stability of Interconnected Power Systems Through HVDE Controls
AC-DC corridors have been extensively used for bulk power transmission. In many of the cases, the power transfer through the parallel A C lines is restricted due to stability limits. Fast active power modulations of the HVDC link could enhance transient stability of interconnected power systems. This could be achieved by effectively utilizing the available headroom of the HVDC link, especially the transient overloading capability of classic HVDC link. In this paper, control schemes for HVDC power modulations are discussed. The effectiveness of HVDC link power modulations is demonstrated through the improved transient stability of the Pacific A C and DC Interties of North America under critical disturbances. System studies are performed using the detailed dynamic model of the Western Interconnection system.
Baseline Evaluations to Support Control Room Modernization at Nuclear Power Plants
For any major control room modernization activity at a commercial nuclear power plant (NPP) in the U.S., a utility should carefully follow the four phases prescribed by the U.S. Nuclear Regulatory Commission in NUREG-0711, Human Factors Engineering Program Review Model. These four phases include Planning and Analysis, Design, Verification and Validation, and Implementation and Operation. While NUREG-0711 is a useful guideline, it is written primarily from the perspective of regulatory review, and it therefore does not provide a nuanced account of many of the steps the utility might undertake as part of control room modernization. The guideline is largely summative—intended to catalog final products—rather than formative—intended to guide the overall modernization process. In this paper, we highlight two crucial formative sub-elements of the Planning and Analysis phase specific to control room modernization that are not covered in NUREG-0711. These two sub-elements are the usability and ergonomics baseline evaluations. A baseline evaluation entails evaluating the system as-built and currently in use. The usability baseline evaluation provides key insights into operator performance using the control system currently in place. The ergonomics baseline evaluation identifies possible deficiencies in the physical configuration of the control system. Both baseline evaluations feed into the design of the replacement system and subsequent summative benchmarking activities that help ensure that control room modernization represents a successful evolution of the control system.
Online Identification of Power Required for Self-Sustainability of the Battery in Hybrid Electric Vehicles
Hybrid electric vehicles have shown great potential for enhancing fuel economy and reducing emissions. Deriving a power management control policy to distribute the power demanded by the driver optimally to the available subsystems (e.g., the internal combustion engine, motor, generator, and battery) has been a challenging control problem. One of the main aspects of the power management control algorithms is concerned with the self-sustainability of the electrical path, which must be guaranteed for the entire driving cycle. This paper considers the problem of identifying online the power required by the battery to maintain the state of charge within a range of the target value. An algorithm is presented that realizes how much power the engine needs to provide to the battery so that self-sustainability of the electrical path is maintained.
Dynamic Modeling of Adjustable-Speed Pumped Storage Hydropower Plant: Preprint
Hydropower is the largest producer of renewable energy in the U.S. More than 60% of the total renewable generation comes from hydropower. There is also approximately 22 GW of pumped storage hydropower (PSH). Conventional PSH uses a synchronous generator, and thus the rotational speed is constant at synchronous speed. This work details a hydrodynamic model and generator/power converter dynamic model. The optimization of the hydrodynamic model is executed by the hydro-turbine controller, and the electrical output real/reactive power is controlled by the power converter. All essential controllers to perform grid-interface functions and provide ancillary services are included in the model.
Common Cause Failure Analysis for Nuclear Power Plant Instrumentation and Control Systems
This presentation is prepared for the IAEA Virtual Consultancy Meeting on Preparation of a Coordinated Research Project on Common Cause Failures in Nuclear Power Plant Instrumentation and Control Systems from February 5 ? 8, 2024. It provides an overview of the INL activities on the common cause failure analysis for instrumentation and control system in nuclear power plants.