Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Portland cement paste behaviour under gamma radiation field in geological repository - 15272

The Radioactive Waste Management Laboratory at the Nuclear and Energy Research Institute in Sao Paulo, Brazil (IPEN-CNEN-SP), is developing the concept of a repository for disposition of disused sealed radioactive sources in a deep borehole in which cement paste is intended to be used as a backfill between the steel casing and the geological formation around the borehole. The cement paste is intended to function as structural material, a blockage against the transport of water between the different strata of the geological setting, and as an additional barrier against the migration of radionuclides. The assessment of the cement paste behaviour in long term is necessary to increase the confidence that the material will perform as required during the service life of the facility. Under radiation, pore water present in cement paste suffers radiolysis and some products can be highly reactive, as electrons and hydroxyl radicals and hydrogen peroxide. These radiolysis products will interact with cement paste and its hydration products, forming a wide range of compounds. Previous work focused on assessing the synergic effects of radiation and environmental conditions, like higher temperature and aggressive groundwater chemicals, on cement paste. Examination of samples detected small differences in mineralogy and microstructure. However, the radiation dose to which samples were exposed (400 kGy) was only a fraction of the expected accumulated dose in cement paste until complete decay of some sealed sources in the repository. Therefore, several thousand kilo-grays must be tested the possibility of radiation to alter cement mineralogy and, as a consequence, its durability The objective of this research is to evaluate the changes in mineralogy and microstructure of irradiated cement paste specimens, in an attempt to establish a relationship between irradiation and durability. Cubic Portland cement specimens were casted and exposed to the gamma radiation of a 60 Co multipurpose irradiator, at IPEN-CNEN/SP. The effects of doses between 1000 kGy and 4000 kGy are evaluated by X-Ray Diffraction, Scanning Electron Microscopy, X-ray micro tomography, neutrongraphy and neutron scattering. This report presents the changes in cement paste mineralogy when samples are examined by XRD. Results indicate that durability can be affected because of the observed changes. Results are expected to indicate the induced changes in cement paste under high radiation doses and to provide hints on its behaviour in the long-term and service-life. The results can be used in safety analysis for deep geological repositories that use cement based materials as engineered barriers. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Strategies for Minimizing Occupational Radiation Exposure in Cardiac Imaging

Purpose of Review: Radiation safety has been at the center of interest of both researchers and healthcare institutions. This review will summarize and shed light on the various techniques adapted to reduce staff exposure to ionizing radiation (IR) in the field of cardiac imaging. Recent Findings: In the last years, with the advance of awareness and the development of new technologies, there have been several tools and techniques adapted. The breakthrough of several technologies to lower radiation dose and shorten the duration of diagnostic tests associated with IR, the use of protection devices by staff members, and mostly the awareness of exposure to IR are the hallmark of these advances. Using all these measures has led to a significant decrease in staff exposure to IR. Summary: Reducing staff exposure to meet the “As Low As Reasonably Achievable” principle is feasible. This review introduces the most important strategies applied in cardiac imaging.

61 RADIATION PROTECTION AND DOSIMETRY↗

Phase 3 Multi-Center, Prospective, Randomized Trial Comparing Single-Dose 24 Gy Radiation Therapy to a 3-Fraction SBRT Regimen in the Treatment of Oligometastatic Cancer

This prospective phase 3 randomized trial was designed to test whether ultra high single-dose radiation therapy (24 Gy SDRT) improves local control of oligometastatic lesions compared to a standard hypofractionated stereotactic body radiation therapy regimen (3 × 9 Gy SBRT). The secondary endpoint was to assess the associated toxicity and the impact of ablation on clinical patterns of metastatic progression.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation-Induced Large Vessel Cerebral Vasculopathy in Pediatric Patients With Brain Tumors Treated With Proton Radiation Therapy

Purpose: The purpose of this research was to evaluate the incidence, time to development, imaging patterns, risk factors, and clinical significance of large vessel cerebral vasculopathy in pediatric patients with brain tumors treated with proton radiation therapy. Methods and Materials: A retrospective study was performed on 75 consecutive pediatric patients with primary brain tumors treated with proton radiation therapy. Radiation-induced large vessel cerebral vasculopathy (RLVCV) was defined as intracranial large vessel arterial stenosis or occlusion confirmed on magnetic resonance angiography, computed tomographic angiography, catheter angiography, or a combination of these within an anatomic region with previous exposure to proton beam therapy and not present before radiation therapy. Clinical records were used to determine the incidence, timing, radiation dose to the large vessels, and clinical significance associated with the development of large vessel vasculopathy in these patients. Results: RLVCV was present in 5 of 75 (6.7%) patients and included tumor pathologic features of craniopharyngioma (n=2), ATRT (n=1), medulloblastoma (n=1), and anaplastic astrocytoma (n=1). The median time from completion of radiation therapy to development was 1.5 years (mean, 3.0 years; range, 1.0-7.5 years). Neither mean age at the time of radiation therapy (5.1 years) nor mean radiation therapy dose to the large vessels (54.5 Gy) was a statistically significant risk factor. Four of the 5 patients with RLVCV presented with acute stroke and demonstrated magnetic resonance imaging evidence of acute infarcts in the expected vascular distributions. Angiography studies demonstrated collateral vessel formation in only 2 of the patients with RLVCV. No patients demonstrated acute hemorrhage or aneurysm. Two patients were treated with pial synangiomatosis surgery. Conclusions: RLVCV can occur in pediatric patients with brain tumors treated with proton radiation therapy. Further studies are necessary to determine potential risk factors for large vessel vasculopathy with proton radiation therapy in comparison with conventional photon radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Changing the Rules of the Game: Used Fuel Studies Outside of a Remote Handling Facility

Recent advances in micro-fabrication tools like the FEI Helios NanoLab 660 dual Focused Ion Beam (FIB) and Scanning Electron Microscope (SEM) now make it possible to easily and reliably prepare micron (or smaller) specimens for analyses or further experimentation. Pacific Northwest National Laboratory (PNNL) has leveraged this capability at the Category II Nuclear Facility, the Radiochemical Processing Laboratory, to facilitate nuclear materials analysis and experimentation of used nuclear fuel. Micron-scale specimens of un-irradiated UO2 fuel pellets of various enrichments from depleted to 4.95% enriched, relative to 235U, were prepared at PNNL and shipped to the University of Missouri’s Research Reactor (MURR) for irradiation. Prior to shipping, samples were attached to commercially available Transmission Electron Microscopy half-grids via ion deposition, which were then housed in specially designed aluminum sample holders approved for use at the reactor facility. This minimized handling and preparation requirements prior to materials analysis after irradiation. Samples were irradiated to a burnup equivalent of 8 – 3,700 MWd/MTU. Additionally, by reducing the size of the specimens, and therefore their emitted radiation dose, the required cooling time after irradiation and prior to analysis was greatly diminished, and handling of these samples could proceed outside of a hot cell facility. Results from these experiments provided insight into the initial production of noble metal phase particles in used nuclear fuel at extremely low burnup levels. Some incompatibility with the container was observed at higher burnup. Micro-scale irradiation experiments were performed at roughly 1/7th of the time, effort and expense a similar bulk-scale study requiring a shielded hot cell facility would require. Conducting nuclear materials analysis at the micron-scale holds the promise of enhancing collaboration and material accessibility to the broader research community, improving accessibility to cutting edge research tools by the nuclear materials science community, lowering the risk to the scientist by reducing radiation dose and exposure, reducing facility and research costs associated with the requirement to conduct nuclear materials science within glovebox or remote handling facilities, and minimizing waste.

Schwantes, Jon M.↗

Uncovering Special Nuclear Materials by Low-energy Nuclear Reaction Imaging

Weapons-grade uranium and plutonium could be used as nuclear explosives with extreme destructive potential. The problem of their detection, especially in standard cargo containers during transit, has been described as “searching for a needle in a haystack” because of the inherently low rate of spontaneous emission of characteristic penetrating radiation and the ease of its shielding. Currently, the only practical approach for uncovering well-shielded special nuclear materials is by use of active interrogation using an external radiation source. However, the similarity of these materials to shielding and the required radiation doses that may exceed regulatory limits prevent this method from being widely used in practice. We introduce a low-dose active detection technique, referred to as low-energy nuclear reaction imaging, which exploits the physics of interactions of multi-MeV monoenergetic photons and neutrons to simultaneously measure the material’s areal density and effective atomic number, while confirming the presence of fissionable materials by observing the beta-delayed neutron emission. For the first time, we demonstrate identification and imaging of uranium with this novel technique using a simple yet robust source, setting the stage for its wide adoption in security applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NUHOMS{sup R} EOS (Extended Optimized Storage): Robust, Advanced, and Dual Purpose Dry Storage System - 16472

AREVA TN has completed the design, analysis, and US NRC license submittal for the NUHOMS{sup R} Extended Optimized Storage (EOS) system. NUHOMS{sup R} EOS offers a large capacity and high heat load dry storage and transportation solution for UNF. EOS is not a new system, but an evolution of the already-proven safe and low-risk horizontal NUHOMS{sup R} storage system, which is one of the most widely used UNF dry storage systems in the United States. The EOS system features a 37PTH dry shielded canister (DSC) for 37 PWR UNF assemblies and an 89BTH DSC for the 89 BWR UNF assemblies. The EOS DSCs will be stored inside a horizontal storage module (HSM) that is a robust, fortress-like concrete storage overpack. Designed with the lessons learned from the Fukushima event in Japan in mind, EOS has robust margins for beyond design basis (BDB) events and offers the lowest risk and highest safety margin of any dry storage system design for recovery from BDB events. EOS also offers innovative aging management features with an aging management program (AMP) to assure safe and low dose long-term storage at the utility sites. EOS incorporates ports for AMP inspections and offers the option of using duplex stainless steel (DSS) for the DSC shell in order to negate corrosion issues. EOS is stored horizontally and above ground, making it easy and quick to access for visual inspection, monitoring, and mitigating actions during AMP. NUHOMS{sup R} EOS is optimized for high capacity, high burnup, high enrichments, and very low cooling times for UNF assemblies. It enables the highest heat load per canister (50 kW) and low dose rates. Even with high heat loads, EOS has significant margins to design basis limits. As the future of used fuel disposition will require the need to move fuel off-site to interim or consolidated storage, EOS is the ideal solution as it enables on-site loading and unloading operations that mitigate risk when transferring fuel on-site or transporting fuel off-site. The EOS design can be safely located in a traditional outdoor setting with fortress-like concrete reinforced modules that offer superior resistance to attack or can be safely operated inside of a building enclosure for those utilities desiring a more discreet siting for its used fuel storage systems. EOS has an innovative basket design that is made of high strength low alloy (HSLA) material and is easy to fabricate due to its non-welded design. Its innovative inlet and outlet air vent design, which incorporates dose reduction hardware, allows for optimal ambient airflow for highly efficient heat transfer with minimal radiation dose. The NUHOMS{sup R} EOS storage modules are interlocked in a side-by-side configuration offering superior and robust seismic performance. The license application for NUHOMS{sup R} EOS is currently under US NRC review and this system will be available for deployment in 2017. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

EVALUATION OF EXISTING PUBLIC DOSE LIMITS APPLIED TO RECREATIONAL SPACEFLIGHT

Abstract Establishing realistic radiation dose limits with a solid scientific basis is a key component of the ‘as low as reasonably achievable’ (ALARA) principle. Although existing occupational dose limits have been established for civil astronauts, with the rise in popularity and technological maturation of the ‘space tourism’ sector, there does not appear to be considerable discussion on the subject of non-occupational astronaut dose limits. The necessity to come to a collective decision on dose limits and radiation safety procedures for recreational spaceflight is urgent and imperative to maintain ALARA goals, as existing federal dose limits to the public cannot be adequately or universally applied to the space tourism sector. Development of an entirely new set of regulations and guidelines should also provide long-term benefits in public perception as evidence of safety commitments from decision makers and the community in protecting passengers from radiological risks balanced with other spaceflight hazards.

Long, Michael A. (ORCID:0000000181363476)↗

A Novel Self-Expandable, Radioactive Airway Stent Loaded with {sup 125}I Seeds: A Feasibility and Safety Study in Healthy Beagle Dog

PurposeAirway stent placement is an effective treatment for the immediate palliation of malignant airway obstruction. However, restenosis caused by tumor ingrowth and/or overgrowth after stenting is common. The purpose of this study was to investigate the feasibility and safety of a novel self-expandable stent loaded with {sup 125}I seeds in healthy beagle dog.Materials and MethodsUnder fluoroscopic guidance, forty-eight self-expandable airway stents loaded with {sup 125}I seeds were perorally placed in the main trachea of 48 healthy beagle dogs, who were randomly divided into four groups (Group A: 0.3 mCi; Group B: 0.6 mCi; Group C: 0.9 mCi; Control group: 0 mCi). The estimated radiation dose was calculated using the isotropic point source approximation. Radiological follow-up examinations and histopathological examinations of stented tracheal segments and their adjacent organs and tissues were performed at 2, 4, 8, and 16 weeks following the stenting.ResultsAll stents were successfully deployed in the targeted tracheal segment in the beagle dogs without procedure-related complications. Tracheal stenosis became severe gradually in all the four groups, which was not associated with the radioactivity of {sup 125}I seeds (p > 0.05). The tracheal injury scores increased along with the higher dose of radioactive seeds which reached peak at 8 weeks and then turned back slightly at 16 weeks. The adjacent tissue did not show pathohistological changes under microscope, while mild and reversible ultrastructure changes were showed under electronic microscope.ConclusionsThis study demonstrates that it is feasible and safe to insert this novel self-expandable airway stent loaded with {sup 125}I seeds in healthy beagle dog.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of silicon 3D pixel detectors for the ATLAS Forward Physics experiment

The ATLAS Forward Physics (AFP) project aims to measure protons scattered under a small angle from the pp collisions in ATLAS. In order to perform such measurements, a new silicon tracker, together with a time-of-flight detector for pile-up removal, are planned to be installed at ∼210 m from the interaction point and at 2-3 mm from the LHC proton beam. To cope with such configuration and maximize the physics outcome, the tracker has to fulfil three main requirements: endure highly non-uniform radiation doses, due to the very inhomogeneous beam profile, have slim and efficient edges to improve the acceptance of the tracker, and provide good position resolution. Recent laboratory and beam test characterization results of AFP prototypes will be presented. Slim-edged 3D pixel detectors down to 100-200 μm were studied and later non-uniformly irradiated (with a peak fluence of several 10{sup 15} n{sub eq}/cm{sup 2}) to determine the fulfilment of the AFP requirements. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A study of the dosimetric characteristics between different fixed-field IMRT and VMAT in early-stage primary mediastinal B-cell lymphoma

This analysis was designed to compare dosimetric parameters among different fixed-field intensity-modulated radiation therapy (IMRT) solutions and volumetric-modulated arc therapy (VMAT) to identify which can achieve the lowest risk of organs at risk (OARs) and treatment delivery efficiently. A total of 16 patients (8 male and 8 female) with early-stage primary mediastinal large B-cell lymphoma (PMBCL) were enrolled with planned gross tumor volume (PGTV) 45 Gy and planning target volume (PTV) 40 Gy. Four different plans were generated: 5-, 7, 9-field IMRT, and VMAT. The dose distributions for PGTV and PTV OARs (lungs, left ventricle, heart, thyroid gland, and breasts) were compared. The monitor units (MUs) and treatment delivery time were also evaluated. Mean conformity index (CI) and homogeneity index (HI) for PGTV in 5F-, 7F-, 9F-IMRT, and VMAT were 1.01 and 1.10, 1.01 and 1.10, 1.01 and 1.10, and 1.01 and 1.11 (p = 0.963 and 0.843), whereas these 2 indices for PTV were 1.04 and 1.22, 1.03 and 1.19, 1.03 and 1.17, and 1.08 and 1.14 (p = 0.964 and 0.969), respectively. D{sub mean} (Gy), V4 (%), D50 (Gy), and D80 (Gy) to the left and right breasts increased by 0.7 Gy and 0.1 Gy, 6.8% and 7.7%, 0.9 Gy and 1.7 Gy, and 1.0 Gy and 1.5 Gy in VMAT, respectively. The 9-beam IMRT plan had the highest MUs (25,762.4 MUs) and the longest treatment delivery time (10.7 minutes); whereas, the VMAT had the lowest MUs (13,345.0) and the shortest treatment delivery time (5.9 minutes). Seven- and 9-field IMRT and VMAT provide improved tumor coverage compared with 5F-IMRT, whereas VMAT shows higher treatment delivery efficiency than IMRT technique. Seven- and 9-field IMRT slightly reduce the low dose radiation exposure of breasts compared with VMAT technique. The 7- and 9-field IMRT and VMAT techniques both can be safely and efficiently delivered to patients with PMBCL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A thermodynamics-based damage model for the non-linear mechanical behavior of SiC/SiC ceramic matrix composites in irradiation and thermal environments

A damage model is developed and validated with experimental data for the non-linear mechanical behavior of SiC/SiC composite materials in nuclear applications. Cyclic thermal and mechanical loading associated with neutron irradiation effects of these composites leads to wide-spread and progressive micro-cracking that leads to loss of thermal conductivity and further enhancement of thermo-mechanical damage. A physics-based model of wide-spread micro-cracking is developed within the thermodynamic framework of continuum damage mechanics. Evolution equations for damage parameters that describe the growth of continuum damage are developed, where the material variables are obtained from experiments. The model novelty is in coupling mechanical, thermal, and irradiation damage through a consistent thermodynamic framework, including loss of thermal conductivity due to the evolution of mechanically induced micro-cracks. A number of thermo-mechanical experiments were conducted to confirm model assumptions. The model is shown to be validated with out-of-pile experiments, and then implemented using commercial finite element code COMSOL to the fuel cladding problem with normal and high radiation dose cases.

Materials Science↗

SU-C-207-03: Optimization of a Collimator-Based Sparse Sampling Technique for Low-Dose Cone-Beam CT

Purpose: In computed tomography (CT) imaging, radiation dose delivered to the patient is one of the major concerns. Sparse-view CT takes projections at sparser view angles and provides a viable option to reducing dose. However, a fast power switching of an X-ray tube, which is needed for the sparse-view sampling, can be challenging in many CT systems. We have earlier proposed a many-view under-sampling (MVUS) technique as an alternative to sparse-view CT. In this study, we investigated the effects of collimator parameters on the image quality and aimed to optimize the collimator design. Methods: We used a bench-top circular cone-beam CT system together with a CatPhan600 phantom, and took 1440 projections from a single rotation. The multi-slit collimator made of tungsten was mounted on the X-ray source for beam blocking. For image reconstruction, we used a total-variation minimization (TV) algorithm and modified the backprojection step so that only the measured data through the collimator slits are to be used in the computation. The number of slits and the reciprocation frequency have been varied and the effects of them on the image quality were investigated. We also analyzed the sampling efficiency: the sampling density and data incoherence in each case. We tested three sets of slits with their number of 6, 12 and 18, each at reciprocation frequencies of 10, 30, 50 and 70 Hz/ro. Results: Consistent results in the image quality have been produced with the sampling efficiency, and the optimum condition was found to be using 12 slits at 30 Hz/ro. As image quality indices, we used the CNR and the detectability. Conclusion: We conducted an experiment with a moving multi-slit collimator to realize a sparse-sampled cone-beam CT. Effects of collimator parameters on the image quality have been systematically investigated, and the optimum condition has been reached.

60 APPLIED LIFE SCIENCES↗

Regional Lymph Node Uptake of [{sup 18}F]Fluorodeoxyglucose After Definitive Chemoradiation Therapy Predicts Local-Regional Failure of Locally Advanced Non-Small Cell Lung Cancer: Results of ACRIN 6668/RTOG 0235

Purpose: The American College of Radiology Imaging Network (ACRIN) 6668/Radiation Therapy Oncology Group (RTOG) 0235 study demonstrated that standardized uptake values (SUV) on post-treatment [{sup 18}F]fluorodeoxyglucose-positron emission tomography (FDG-PET) correlated with survival in locally advanced non-small cell lung cancer (NSCLC). This secondary analysis determined whether SUV of regional lymph nodes (RLNs) on post-treatment FDG-PET correlated with patient outcomes. Methods and Materials: Included for analysis were patients treated with concurrent chemoradiation therapy, using radiation doses ≥60 Gy, with identifiable FDG-avid RLNs (distinct from primary tumor) on pretreatment FDG-PET, and post-treatment FDG-PET data. ACRIN core laboratory SUV measurements were used. Event time was calculated from the date of post-treatment FDG-PET. Local-regional failure was defined as failure within the treated RT volume and reported by the treating institution. Statistical analyses included Wilcoxon signed rank test, Kaplan-Meier curves (log rank test), and Cox proportional hazards regression modeling. Results: Of 234 trial-eligible patients, 139 (59%) had uptake in both primary tumor and RLNs on pretreatment FDG-PET and had SUV data from post-treatment FDG-PET. Maximum SUV was greater for primary tumor than for RLNs before treatment (P<.001) but not different post-treatment (P=.320). Post-treatment SUV of RLNs was not associated with overall survival. However, elevated post-treatment SUV of RLNs, both the absolute value and the percentage of residual activity compared to the pretreatment SUV were associated with inferior local-regional control (P<.001). Conclusions: High residual metabolic activity in RLNs on post-treatment FDG-PET is associated with worse local-regional control. Based on these data, future trials evaluating a radiation therapy boost should consider inclusion of both primary tumor and FDG-avid RLNs in the boost volume to maximize local-regional control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Flux Estimation of a PuBe source using Delayed Gamma Neutron Activation Analysis

For handling and storage of a highly radioactive source, it is necessary to have an accurate knowledge of the radioactive source as well as the neutron flux. Recently, due to radiation safety requirements, a PuBe alpha-neutron source at an activation facility at IIT-Kanpur had to be taken out of its original damaged howitzer and placed inside a new shielded container. While, this effort was successful in reducing the radiation dose, and making the setup safe for laboratory measurements, the new source moderator configuration left the new Pu-Be source spectrum unknown. Therefore, in this work we have used delayed gamma neutron activation analysis (DGNAA) of aluminum, copper, iron, manganese (found in iron), and silver for thermal neutron flux estimation of the Pu-Be neutron source. A series of DGNAA measurements with different samples were carried out to find the value of the average thermal neutron flux of a Pu-Be neutron source at Indian Institute of Technology-Kanpur. The order of the thermal neutron flux is found to be nearly 1.64 x 10{sup 5} excluding aluminum. Upon including aluminum, the value of thermal neutron flux decreases to 1.57x10{sup 5}. We have used common metals (like aluminum, silver, copper and iron) to calculate the thermal neutron flux. The calculated value of the thermal neutron flux is consistent for all the metals except for iron. Iron is giving a value almost four times larger than the average calculated value of the thermal neutron flux using other six samples. The reason is currently being investigated. The DGNAA technique came out to be a very useful technique. Now that we know the thermal neutron flux of the Pu-Be source, our future work will include improving the safety and shielding calculations for our activation facility at IIT-Kanpur. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-373: A Motorized Stage for Fast and Accurate QA of Machine Isocenter

Purpose: Precision delivery of radiation dose relies on accurate knowledge of the machine isocenter under a variety of machine motions. This is typically determined by performing a Winston-Lutz test consisting of imaging a known object at multiple gantry/collimator/table angles and ensuring that the maximum offset is within specified tolerance. The first step in the Winston-Lutz test is careful placement of a ball bearing at the machine isocenter as determined by repeated imaging and shifting until accurate placement has been determined. Conventionally this is performed by adjusting a stage manually using vernier scales which carry the limitation that each adjustment must be done inside the treatment room with the risks of inaccurate adjustment of the scale and physical bumping of the table. It is proposed to use a motorized system controlled outside of the room to improve the required time and accuracy of these tests. Methods: The three dimensional vernier scales are replaced by three motors with accuracy of 1 micron and a range of 25.4mm connected via USB to a computer in the control room. Software is designed which automatically detects the motors and assigns them to proper axes and allows for small shifts to be entered and performed. Input values match calculated offsets in magnitude and sign to reduce conversion errors. Speed of setup, number of iterations to setup, and accuracy of final placement are assessed. Results: Automatic BB placement required 2.25 iterations and 13 minutes on average while manual placement required 3.76 iterations and 37.5 minutes. The average final XYZ offsets is 0.02cm, 0.01cm, 0.04cm for automatic setup and 0.04cm, 0.02cm, 0.04cm for manual setup. Conclusion: Automatic placement decreased time and repeat iterations for setup while improving placement accuracy. Automatic placement greatly reduces the time required to perform QA.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-295: Simultaneous Beam Sampling and Aperture Shape Optimization for Station Parameter Optimized Radiation Therapy (SPORT)

Purpose: Station Parameter Optimized Radiation Therapy (SPORT) was recently proposed to fully utilize the technical capability of emerging digital LINACs, in which the station parameters of a delivery system, (such as aperture shape and weight, couch position/angle, gantry/collimator angle) are optimized altogether. SPORT promises to deliver unprecedented radiation dose distributions efficiently, yet there does not exist any optimization algorithm to implement it. The purpose of this work is to propose an optimization algorithm to simultaneously optimize the beam sampling and aperture shapes. Methods: We build a mathematical model whose variables are beam angles (including non-coplanar and/or even nonisocentric beams) and aperture shapes. To solve the resulting large scale optimization problem, we devise an exact, convergent and fast optimization algorithm by integrating three advanced optimization techniques named column generation, gradient method, and pattern search. Column generation is used to find a good set of aperture shapes as an initial solution by adding apertures sequentially. Then we apply the gradient method to iteratively improve the current solution by reshaping the aperture shapes and updating the beam angles toward the gradient. Algorithm continues by pattern search method to explore the part of the search space that cannot be reached by the gradient method. Results: The proposed technique is applied to a series of patient cases and significantly improves the plan quality. In a head-and-neck case, for example, the left parotid gland mean-dose, brainstem max-dose, spinal cord max-dose, and mandible mean-dose are reduced by 10%, 7%, 24% and 12% respectively, compared to the conventional VMAT plan while maintaining the same PTV coverage. Conclusion: Combined use of column generation, gradient search and pattern search algorithms provide an effective way to optimize simultaneously the large collection of station parameters and significantly improves quality of resultant treatment plans as compared with conventional VMAT or IMRT treatments.

07 ISOTOPE AND RADIATION SOURCES↗

The Legislative and Regulatory Histories Related to Greater-Than-Class-C Low-Level Radioactive Waste - 18602

The history surrounding the legislative and regulatory developments regarding Greater-Than-Class C Low Level Radioactive Waste (GTCC LLW) is both interesting and complex. On October 25, 1978, the U.S. Nuclear Regulatory Commission (NRC) published an Advanced Notice of Proposed Rulemaking pertaining to the development of regulations for the land disposal of LLW. This regulation was one of the first undertaken by NRC since its inception pursuant to the Energy Reorganization Act of 1974. Given the problematic challenges that many States were facing with releases of radioactivity from waste disposal facilities at the time, the technical bases supporting this rulemaking were both forward-thinking and comprehensive. The rule included a waste classification system that was tiered in four waste classes: Class A, B, C and GTCC LLW. On December 27, 1982, the NRC finalized the requirements for disposing of these classes of radioactive waste in Title 10 of the Code of Federal Regulations, Part 61 (10 CFR 61). The NRC established the waste classification system to protect both members of the public and individuals that may someday inadvertently intrude in the waste placed in the disposal facility after expiration of the institutional control period. This waste classification was developed to ensure that radiation doses to members of the public and an inadvertent intruder would not exceed 0.25 mSv y{sup -1} (25 mrem y{sup -1}) or 5.0 mSv y{sup -1} (500 mrem y{sup -1}), respectively. At the time the regulation was promulgated, GTCC LLW was considered generally not suitable for near surface disposal. It was recognized that disposal of GTCC LLW would require disposal technologies having greater confinement capacity or protection than 'normal' near-surface disposal. In 1980 Congress enacted the Low-Level Waste Policy Act of 1980, as amended in 1985 (LLWPAA of 1985) that assigned responsibility of disposing of GTCC LLW generated in the commercial sector or owned or generated by the federal government to the U.S. Department of Energy (DOE). At the time States were having difficulties in developing disposal facilities within the time constraints mandated in the LLWPA of 1980. Therefore, Congress believed that if DOE was assigned responsibility of developing disposal facilities for GTCC LLW, then the States would be more likely to develop new LLW disposal facilities. Congress also assigned the NRC with the responsibility to license the disposal of GTCC LLW generated or owned by the federal government or by the commercial sector. Lastly, Congress changed the definition of LLW that had been defined in the LLWPA of 1980 removing the 'transuranic' exclusionary language. Four years later, on May 25, 1989, the NRC promulgated its regulation needed to implement the mandates specified in the LLWPAA of 1985. The NRC revised 10 CFR 61.55 specifying that the NRC was responsible for licensing the disposal of GTCC LLW. However, it inadvertently did not revise the definition of LLW needed to remove the 'transuranic' exclusionary language in this rulemaking consistent with the LLWPAA of 1985. This seemingly inconsequential omission was not discovered until a Petition for Rulemaking was filed in Texas in July 2014. Moreover, this omission has effectively orphaned waste with certain transuranic radionuclides with concentrations exceeding 100 nanocuries per gram (100 nCi/g). In December 2015, the NRC Commissioners directed its staff to move forward with a rulemaking to resolve this issue and to perform a regulatory analysis to determine whether or not an Agreement State can license the disposal of GTCC LLW pursuant to Section 274 of the Atomic Energy Act of 1954. The paper will discuss past and current legislation, rulemaking, and regulatory developments pertaining to resolving the transuranic waste discrepancy and providing a pathway to disposition GTCC LLW. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗