Search NASA⌕ Search

SEARCH · Search NASA

Results for “Random vibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Ruggedizing a Commercial Depth Camera for Novel Lunar Exploration.

The novel contribution of this instrument is to take the first depth images on the moon. A commercial Kinect camera from Microsoft has been ruggedized for a CLPS mission to the Lunar South Pole. The 12-megapixel color camera is combined with a 1-megapixel color time-of-flight (ToF) depth sensor. The solid-state depth sensor/LIDAR provides greater resolution, a wider field of view, pixel binning, and reduced power consumption. The high-resolution data collected from the mission can be used to construct a near-field virtual environment of the lunar surface for scientific applications. The depth camera can provide a 360-degree view of the target area by combining ToF data with RGB imagery and rover turning. The unit was evaluated for space flight compliant materials and parts at NASA Ames. The microphone array, RF shield, front face, and outer body parts were removed to reduce mass. Plastic parts were replaced with vacuum-compatible materials; manufactured cables were added to properly interface with the host rover, built by Lunar Outpost. The environmental testing was performed on the Kinect with Random Vibration/Sine Testing (Fig 1a), per GEVS (NASA’s General Environmental Verification Standard for spaceflight launch survival). Thermal Vacuum testing cycled the instrument between expected hot (+ 85 C) and cold survival temperatures, as well as +50 C and -25 C operational temps (Fig 1b). The instrument functioned nominally at the conclusion of vibration and thermal cycling tests. The Azure Kinect is manifested on the Nova-C lander which flies on the Intuitive Machines mission IM-2, landing at the lunar south pole for a mission duration of 14 days (one lunar daylight cycle). The unit will be integrated to the MAPP (Mobile Autonomous Prospecting Platform) rover at Lunar Outpost. The Azure Kinect with ToF feature will improve the resolution of lunar geology data near the south pole and enable ground-based VR experience of details of the lunar surface (Fig 1c).

V. Jha↗

Modeling, Detection, and Disambiguation of Sensor Faults for Aerospace Applications

Sensor faults continue to be a major hurdle for systems health management to reach its full potential. At the same time, few recorded instances of sensor faults exist. It is equally difficult to seed particular sensor faults. Therefore, research is underway to better understand the different fault modes seen in sensors and to model the faults. The fault models can then be used in simulated sensor fault scenarios to ensure that algorithms can distinguish between sensor faults and system faults. The paper illustrates the work with data collected from an electro-mechanical actuator in an aerospace setting, equipped with temperature, vibration, current, and position sensors. The most common sensor faults, such as bias, drift, scaling, and dropout were simulated and injected into the experimental data, with the goal of making these simulations as realistic as feasible. A neural network based classifier was then created and tested on both experimental data and the more challenging randomized data sequences. Additional studies were also conducted to determine sensitivity of detection and disambiguation efficacy to severity of fault conditions.

Balaban, Edward↗

Microgravity vibration isolation technology: Development to demonstration

The low gravity environment provided by space flight has afforded the science community a unique area for the study of fundamental and technological sciences. However, the dynamic environment observed on space shuttle flights and predicted for Space Station Freedom has complicated the analysis of prior 'microgravity' experiments and prompted concern for the viability of proposed space experiments requiring long term, low gravity environments. Thus, isolation systems capable of providing significant improvements to this random environment have been developed. This dissertation deals with the design constraints imposed by acceleration sensitive, microgravity experiment payloads in the unique environment of space. A theoretical background for the inertial feedback and feedforward isolation of a payload was developed giving the basis for two experimental active inertial isolation systems developed for the demonstration of these advanced active isolation techniques. A prototype six degree of freedom digital active isolation system was designed and developed for the ground based testing of an actively isolated payload in three horizontal degrees of freedom. A second functionally equivalent system was built for the multi-dimensional testing of an active inertial isolation system in a reduced gravity environment during low gravity aircraft trajectories. These multi-input multi-output control systems are discussed in detail with estimates on acceleration noise floor performance as well as the actual performance acceleration data. The attenuation performance is also given for both systems demonstrating the advantages between inertial and non-inertial control of a payload for both the ground base environment and the low gravity aircraft acceleration environment. A future goal for this area of research is to validate the technical approaches developed to the 0.01 Hz regime by demonstrating a functional active inertial feedforward/feedback isolation system during orbital flight. A NASA IN-STEP flight experiment has been proposed to accomplish this goal, and the expected selection for the IN-STEP program has been set for Jul. of 1993.

Grodsinsky, Carlos M.↗

GOES-R Active Vibration Damping Controller Design, Implementation, and On-Orbit Performance

GOES-R series spacecraft feature a number of flexible appendages with modal frequencies below 3.0 Hz which, if excited by spacecraft disturbances, can be sources of undesirable jitter perturbing spacecraft pointing. In order to meet GOES-R pointing stability requirements, the spacecraft flight software implements an Active Vibration Damping (AVD) rate control law which acts in parallel with the nadir point attitude control law. The AVD controller commands spacecraft reaction wheel actuators based upon Inertial Measurement Unit (IMU) inputs to provide additional damping for spacecraft structural modes below 3.0 Hz which vary with solar wing angle. A GOES-R spacecraft dynamics and attitude control system identified model is constructed from pseudo-random reaction wheel torque commands and IMU angular rate response measurements occurring over a single orbit during spacecraft post-deployment activities. The identified Fourier model is computed on the ground, uplinked to the spacecraft flight computer, and the AVD controller filter coefficients are periodically computed on-board from the Fourier model. Consequently, the AVD controller formulation is based not upon pre-launch simulation model estimates but upon on-orbit nadir point attitude control and time-varying spacecraft dynamics. GOES-R high-fidelity time domain simulation results herein demonstrate the accuracy of the AVD identified Fourier model relative to the pre-launch spacecraft dynamics and control truth model. The AVD controller on-board the GOES-16 spacecraft achieves more than a ten-fold increase in structural mode damping of the fundamental solar wing mode while maintaining controller stability margins and ensuring that the nadir point attitude control bandwidth does not fall below 0.02 Hz. On-orbit GOES-16 spacecraft appendage modal frequencies and damping ratios are quantified based upon the AVD system identification, and the increase in modal damping provided by the AVD controller for each structural mode is presented. The GOES-16 spacecraft AVD controller frequency domain stability margins and nadir point attitude control bandwidth are presented along with on-orbit time domain disturbance response performance.

Active Vibration Damping↗

Diagnosis of Corrosion Process in Nuclear Power Plant Secondary Piping Structures

Corrosion inside secondary pipe structures in Nuclear Power Plants is difficult to detect without intrusion. Statistical and machine learning techniques are used to predict corrosion using pipe vibration data. 3D accelerometers were used to record pipe vibration data in three directions using six sensors. Vibration data were processed using the Hilbert-Huang Transformation, which is known for its adaptable basis function to non-linear and non-stationary signals. Hilbert-Huang Transformation using empirical mode functions generates multiple intrinsic mode functions of different amplitude and frequency levels from raw vibration data. From intrinsic mode functions features are extracted which include phase, energy, entropy, mean, standard deviation, skewness, and kurtosis. Logistic regression using only phase information correctly distinguished mass additions from baseline data in roughly 83% and 85% of the cases. Phase information varied substantially among different baseline runs and within trials of the same run. Random Forest resulted in >95% testing accuracy for both mass addition and mass removal data. Support Vector Machine had ~98% testing accuracy for mass removal and ~92% testing accuracy for mass additions when using Permutation Importance feature selection. When using Principle Component Analysis with Support Vector Machine, testing accuracy was ~68% testing accuracy for mass additions and ~85% testing accuracy for mass.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved spacecraft radio science using an on-board atomic clock: Application to gravitational wave searches

Recent advances in space-qualified atomic clocks (low-mass, low power-consumption, frequency stability comparable to that of ground-based clocks) can enable interplanetary spacecraft radio science experiments at unprecedented Doppler sensitivities. The addition of an on-board digital receiver would allow the up- and down-link Doppler frequencies to be measured separately. Such separate, high-quality measurements allow optimal data combinations that suppress the currently leading noise sources: phase scintillation noise from the Earth's atmosphere and Doppler noise caused by mechanical vibrations of the ground antenna. Here we provide a general expression for the optimal combination of ground and on-board Doppler data and compute the sensitivity such a system would have to low-frequency gravitational waves (GWs). Assuming a plasma scintillation noise calibration comparable to that already demonstrated with the multilink CASSINI radio system, the space-clock/digital-receiver instrumentation enhancements would give GW strain sensitivity of 3.7x10{sup -14} Hz{sup -1/2} for randomly polarized, monochromatic GW signals isotropically distributed over the celestial sphere, over a two-decade ({approx}0.0001-0.01 Hz) region of the low-frequency band. This is about an order of magnitude better than currently achieved with traditional two-way coherent Doppler experiments. The utility of optimally combining simultaneous up- and down-link observations is not limited to GW searches. The Doppler tracking technique discussed here could be performed at minimal incremental cost to improve also other radio science experiments (i.e., tests of relativistic gravity, planetary and satellite gravity field measurements, atmospheric and ring occultations) on future interplanetary missions.

79 ASTRONOMY AND ASTROPHYSICS↗

Ab initio determination of the proton affinities of small neutral and anionic molecules

The proton affinity of a molecule in the gas phase is a fundamental measure of its basicity and is the factor controlling the course of many ion-molecule reactions. In this article, ab initio molecular orbital theory at the MP4/6-311 ++ G(3df, 3pd) level of theory is demonstrated to predict proton affinities (PA's) for small neutral and anionic bases to within 2 kcal mol-1. Furthermore, the errors are random, indicating that there are likely no systematic errors in either the experimental or theoretical PA's. Also, this level of theory is used to calibrate less sophisticated theoretical models which are suitable for larger molecules; the MP4/6-311 ++ G(2d, 2p) and MP2/6-311 ++ G(d, p) theoretical models should be particularly useful. A procedure for predicting the vibrational frequencies for anion is proposed and applied to CH3-, NH2-, OH-, and CN-.

Non-NASA Center↗

Predicting surface deformation during mechanical attrition of metallic alloys

Extensive efforts have been devoted in both the engineering and scientific domains to seek new designs and processing techniques capable of making stronger and tougher materials. One such method for enhancing such damage-tolerance in metallic alloys is a surface nano-crystallization technology that involves the use of hundreds of small hard balls which are vibrated using high-power ultrasound so that they impact onto the surface of a material at high speed (termed Surface Mechanical Attrition Treatment or SMAT). However, few studies have been devoted to the precise underlying mechanical mechanisms associated with this technology and the effect of processing parameters. As SMAT is dynamic plastic deformation process, here we use random impact deformation as a means to investigate the relationship between impact deformation and the parameters involved in the processing, specifically ball size, impact velocity, ball density and kinetic energy. Using analytical and numerical solutions, we examine the size of the indents and the depths of the associated plastic zones induced by random impacts, with results verified by experiment in austenitic stainless steels. In addition, global random impact and local impact frequency models are developed to analyze the statistical characteristics of random impact coverage, together with a description of the effect of random multiple impacts, which are more reflective of SMAT. We believe that these models will serve as a necessary foundation for further, and more energy-efficient, development of such surface nano-crystalline processing technologies for the strengthening of metallic materials.

36 MATERIALS SCIENCE↗

TH-A-207B-00: Shear-Wave Imaging and a QIBA US Biomarker Update

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

TH-A-207B-01: Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

TH-A-207B-02: QIBA Ultrasound Elasticity Imaging System Biomarker Qualification and User Testing of Systems

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

The effects of excitation waveforms and shaker moving mass on the measured modal characteristics of a 2- by 5-foot aluminum plate

Ground vibration tests were conducted to compare and to investigate the effects of five excitation waveforms and the shaker moving mass (equipment and armature used to attach the shaker to the structure) on the experimental modal characteristics of a 2- by 5-ft aluminum plate using fast Fourier transform techniques. The five types of excitation waveforms studied were sine dwell, random, impact, sine sweep, and impulsive sine. The results showed that the experimental modal frequencies for all types of excitation were within 3 percent, while the modal damping data exhibited greater scatter. The sets of mode shapes obtained by the five types of excitation were consistent. The results of the shaker moving mass investigation on the 2- by 5-ft aluminum plate showed that modal frequency decreases and modal damping remains relatively constant with an increase in shaker moving mass. The generalized mass of the structure appears to decrease with an increase in shaker moving mass. In addition, it was seen that having a shaker near a node line can reduce some of the effects of the added shaker moving mass on the frequencies and the damping.

Voracek, David F.↗

First-principles study on the mechanical and thermodynamic properties of MoNbTaTiW

Refractory high-entropy alloys (RHEAs) are emerging as new materials for high temperature structural applications because of their stable mechanical and thermal properties at temperatures higher than 2273 K. In this study, the mechanical properties of MoNbTaTiW REDEA are examined by applying calculations based on first-principles density functional theory (DFT) and using a large unit cell with 100 randomized atoms. The phase calculation of MoNbTaTiW with CALPHAD method shows the existence of a stable body-centered cubic structure at a high temperature and a hexagonal closely packed phase at a low temperature. The predicted phase, shear modulus, Young’s modulus, Poisson’s ratio, and hardness values are consistent with available experimental results. The linear thermal expansion coefficient, vibrational entropy, and vibrational heat capacity of MoNbTaTiW RHEA are investigated in accordance with Debye-Grüneisen theory. These results may provide a basis for future research related to the application of RHEAs.

36 MATERIALS SCIENCE↗

Particlelike Phonon Propagation Dominates Ultralow Lattice Thermal Conductivity in Crystalline Tl 3 VSe 4

We explore the microscopic mechanisms of ultralow lattice thermal conductivity ($\kappa_{l}$) in Tl$_{3}$VSe$_{4}$~by combining a first-principles density-functional theory (DFT) based framework of anharmonic lattice dynamics with the Peierls-Boltzmann transport equation (PBTE) for phonons. We include contributions of the three- and four-phonon scattering processes to the phonon lifetimes as well as the temperature-dependent anharmonic renormalization of phonon energies arising from an unusually strong quartic anharmonicity in Tl$_{3}$VSe$_{4}$. In contrast to a recent report by Mukhopadhyay~\etal [\textcolor{blue}{Science 360, 1455 (2018)}] which suggested that a significant contribution to $\kappa_{l}$ arises from random walks among uncorrelated oscillators, we show that particle-like propagation of phonon excitations can successfully explain the experimentally observed ultralow $\kappa_{l}$. Our results are also supported by explicit calculations of the off-diagonal terms of the heat-current operator, which are found to be small and indicate that wave-like tunneling of heat-carrying vibrations is of minor importance. Our results (i) resolve the discrepancy between the theoretical and experimental $\kappa_{l}$, (ii) offer new insights into the minimum $\kappa_{l}$ achievable in \TlVSe, and (iii) highlight the importance of high-order anharmonicity in low-$\kappa_{l}$ systems. The methodology demonstrated here may be used to resolve the discrepancies between the experimentally measured and the theoretically calculated $\kappa_{l}$ in skutterides and perovskites, as well as to understand the glasslike $\kappa_{l}$ in complex crystals with strong anharmonicity, leading towards the goal of rational design of new materials.

36 MATERIALS SCIENCE↗

Desorption Kinetics of O and CO from Graphitic Carbon Surfaces

The desorption of O/CO from graphitic carbon surfaces is investigated using a one-dimensional model describing the adsorbate interactions with the surface phonon bath. The kinetics of desorption are described through the solution of a master equation for the time-dependent population of the adsorbate in an oscillator state, which is modified through thermal fluctuations at the surface. The interaction of the adsorbate with the surface phonons is explicitly captured by using the computed phonon density Of states (PDOS) of the surface. The coupling of the adsorbate with the phonon bath results in the transition of the adsorbate up and down a vibrational ladder. The adsorbate-surface interaction is represented in the model using a Morse potential, which allows for the desorption process to be directly modeled as a transition from bound to free (continuum) state. The PDOS is a property of the material and the lattice; and is highly sensitive to the presence of defects. The effect of etch pits along with random surface defects on the PDOS is considered in the present work. The presence of defects causes a redshift and broadening of the PDOS, which in turn changes the phonon frequency modes available for adsorbate coupling at the surface. Using the realistic PDOS distributions, the phonon-induced desorption (PID) model was used to compute the transition and desorption rates for both pristine and defective systems. Mathissen’s rule is used to compute the phonon relaxation time for pristine and defective systems based on the phonon scattering times for each of the different scattering processes. First, the desorption rates of the pristine system is fitted against the experimental values to obtain the Morse potential parameters for each of the observed adatoms. These Morse potential parameters are used along with the defective PDOS and phonon relaxation time to compute the desorption rates for the defective system. The defective system rates (both transition and desorption) were consistently lower in comparison with the pristine system. The difference between the transition rates is more significant at lower initial states due to higher energy spacing between the levels. In the case of the desorption rates, the difference between the defective and pristine system is more significant at higher temperatures. The desorption rates for each of the system shows an order of magnitude decrease with the strongly bound systems exhibiting the greatest reduction in the desorption rates.

Swaminathan-Gopalan, Krishnan↗

Stimulated Raman scattering of laser dye mixtures dissolved in multiple scattering media

Stimulated Raman scattering (SRS) of a mixture of rhodamine 6G and pyrromethene 605 laser dyes in vesicular films is studied. It is shown that a peculiar interaction of dyes occurs under conditions of multiple scattering of light from vesicles. This interaction manifests itself as SRS excitation of one of the dyes by random lasing of the other dye, provided that the random lasing spectrum overlaps the Stokes lines of the first dye. In addition, there is energy transfer between molecules of these dyes if their luminescence and absorption spectra overlap. The results obtained confirm that the mechanism of SRS from laser dyes in multiple scattering media is similar to that in coherent-active Raman spectroscopy. These results extend the possibility of determining the vibrational spectrum of dye molecules from their secondary radiation in these media. (nonlinear optical phenomena)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vibration localization in mono- and bi-coupled bladed disks - A transfer matrix approach

A transfer matrix approach to the analysis of the dynamics of mistuned bladed disks is presented. The study focuses on mono-coupled systems, in which each blade is coupled to its two neighboring blades, and bi-coupled systems, where each blade is coupled to its four nearest neighbors. Transfer matrices yield the free dynamics, both the characteristic free wave and the normal modes - in closed form for the tuned assemblies. Mistuned assemblies are represented by random transfer matrices and an examination of the effect of mistuning on harmonic wave propagation yields the localization factor - the average rate of spatial wave amplitude decay per blade - in the mono-coupled assembly. Based on a comparison of the wave propagation characteristics of the mono- and bi-coupled assemblies, important conclusions are drawn about the effect of the additional coupling coordinate on the sensitivity to mistuning and the strength of mode localization predicted by a mono-coupled analysis.

Ottarsson, Gisli↗

Suppression of biodynamic interference in head-tracked teleoperation

The utility of helmet-tracked sights to provide pointing commands for teleoperation of cameras, lasers, or antennas in aircraft is degraded by the presence of uncommanded, involuntary heat motion, referred to as biodynamic interference. This interference limits the achievable precision required in pointing tasks. The noise contributions due to biodynamic interference consists of an additive component which is correlated with aircraft vibration and an uncorrelated, nonadditive component, referred to as remnant. An experimental simulation study is described which investigated the improvements achievable in pointing and tracking precision using dynamic display shifting in the helmet-mounted display. The experiment was conducted in a six degree of freedom motion base simulator with an emulated helmet-mounted display. Highly experienced pilot subjects performed precision head-pointing tasks while manually flying a visual flight-path tracking task. Four schemes using adaptive and low-pass filtering of the head motion were evaluated to determine their effects on task performance and pilot workload in the presence of whole-body vibration characteristic of helicopter flight. The results indicate that, for tracking tasks involving continuously moving targets, improvements of up to 70 percent can be achieved in percent on-target dwelling time and of up to 35 percent in rms tracking error, with the adaptive plus low-pass filter configuration. The results with the same filter configuration for the task of capturing randomly-positioned, stationary targets show an increase of up to 340 percent in the number of targets captured and an improvement of up to 24 percent in the average capture time. The adaptive plus low-pass filter combination was considered to exhibit the best overall display dynamics by each of the subjects.

Lifshitz, S.↗