Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Nanoscale imaging of whole cells using a liquid enclosure and a scanning transmission electron microscopy

Nanoscale imaging techniques are needed to investigate cellular function at the level of individual proteins and to study the interaction of nanomaterials with biological systems. We imaged whole fixed cells in liquid state with a scanning transmission electron microscope (STEM) using a micrometer-sized liquid enclosure with electron transparent windows providing a wet specimen environment. Wet-STEM images were obtained of fixed E. coli bacteria labeled with gold nanoparticles attached to surface membrane proteins. Mammalian cells (COS7) were incubated with gold-tagged epidermal growth factor and fixed. STEM imaging of these cells resulted in a resolution of 3 nm for the gold nanoparticles. The wet-STEM method has several advantages over conventional imaging techniques. Most important is the capability to image whole fixed cells in a wet environment with nanometer resolution, which can be used, e.g., to map individual protein distributions in/on whole cells. The sample preparation is compatible with that used for fluorescent microscopy on fixed cells for experiments involving nanoparticles. Thirdly, the system is rather simple and involves only minimal new equipment in an electron microscopy (EM) laboratory.

59 BASIC BIOLOGICAL SCIENCES↗

Sensitivity of Beam Parameters to a Station C Solenoid Scan on Axis II

Magnet scans are a standard technique for determining beam parameters in accelerators. Beam parameters are inferred from spot size measurements using a model of the beam optics. The sensitivity of the measured beam spot size to the beam parameters is investigated for typical DARHT Axis II beam energies and currents. In a typical S4 solenoid scan, the downstream transport is tuned to achieve a round beam at Station C with an envelope radius of about 1.5 cm with a very small divergence with S4 off. The typical beam energy and current are 16.0 MeV and 1.625 kA. Figures 1-3 show the sensitivity of the bean size at Station C to the emittance, initial radius and initial angle respectively. To better understand the relative sensitivity of the beam size to the emittance, initial radius and initial angle, linear regressions were performed for each parameter as a function of the S4 setting. The results are shown in Figure 4. The measured slope was scaled to have a maximum value of 1 in order to present the relative sensitivities in a single plot. Figure 4 clearly shows the beam size at the minimum of the S4 scan is most sensitive to emittance and relatively insensitive to initial radius and angle as expected. The beam emittance is also very sensitive to the beam size of the converging beam and becomes insensitive to the beam size of the diverging beam. Measurements of the beam size of the diverging beam provide the greatest sensitivity to the initial beam radius and to a lesser extent the initial beam angle. The converging beam size is initially very sensitive to the emittance and initial angle at low S4 currents. As the S4 current is increased the sensitivity to the emittance remains strong while the sensitivity to the initial angle diminishes.

43 PARTICLE ACCELERATORS↗

Interferometric 4D-STEM for Lattice Distortion and Interlayer Spacing Measurements of Bilayer and Trilayer 2D Materials

Van der Waals materials composed of stacks of individual atomic layers have attracted considerable attention due to their exotic electronic properties that can be altered by, e.g., manipulating the twist angle of bilayer materials or the stacking sequence of trilayer materials. To fully understand and control the unique properties of these few-layer materials, a technique that can provide information about their local in-plane structural deformations, twist direction, and out-of-plane structure is needed. In principle, interference in overlap regions of Bragg disks originating from separate layers of a material encodes 3D information about the relative positions of atoms in the corresponding layers. Here, an interferometric 4D scanning transmission electron microscopy technique is described that utilizes this phenomenon to extract precise structural information from few-layer materials with nm-scale resolution. It is demonstrated how this technique enables measurement of local pm-scale in-plane lattice distortions as well as twist direction and average interlayer spacings in bilayer and trilayer graphene, and therefore provides a means to better understand the interplay between electronic properties and precise structural arrangements of few-layer 2D materials.

36 MATERIALS SCIENCE↗

The M. D. Anderson proton therapy system

Purpose: The purpose of this study is to describe University of Texas M. D. Anderson proton therapy system (PTC-H) including the accelerator, beam transport, and treatment delivery systems, the functionality and clinical parameters for passive scattering and pencil beam scanning treatment modes, and the results of acceptance tests. Methods: The PTC-H has a synchrotron (70-250 MeV) and four treatment rooms. An overall control system manages the treatment, physics, and service modes of operation. An independent safety system ensures the safety of patients, staff, and equipment. Three treatment rooms have isocentric gantries and one room has two fixed horizontal beamlines, which include a large-field treatment nozzle, used primarily for prostate treatments, and a small-field treatment nozzle for ocular treatments. Two gantry treatment rooms and the fixed-beam treatment room have passive scattering nozzles. The third gantry has a pencil beam scanning nozzle for the delivery of intensity modulated proton treatments (IMPT) and single field uniform dose (SFUD) treatments. The PTC-H also has an experimental room with a fixed horizontal beamline and a passive scattering nozzle. The equipment described above was provided by Hitachi, Ltd. Treatment planning is performed using the Eclipse system from Varian Medical Systems and data management is handled by the MOSAIQ system from IMPAC Medical Systems, Inc. The large-field passive scattering nozzles use double scattering systems in which the first scatterers are physically integrated with the range modulation wheels. The proton beam is gated on the rotating range modulation wheels at gating angles designed to produce spread-out-Bragg peaks ranging in size from 2 to 16 g/cm{sup 2}. Field sizes of up to 25x25 cm{sup 2} can be achieved with the double scattering system. The IMPT delivery technique is discrete spot scanning, which has a maximum field size of 30x30 cm{sup 2}. Depth scanning is achieved by changing the energy extracted from the synchrotron (energy can be changed pulse to pulse). The PTC-H is fully integrated with DICOM-RT ION interfaces for imaging, treatment planning, data management, and treatment control functions. Results: The proton therapy system passed all acceptance tests for both passive scattering and pencil beam scanning. Treatments with passive scattering began in May 2006 and treatments with the scanning system began in May 2008. The PTC-H was the first commercial system to demonstrate capabilities for IMPT treatments and the first in the United States to treat using SFUD techniques. The facility has been in clinical operation since May 2006 with up-time of approximately 98%. Conclusions: As with most projects for which a considerable amount of new technology is developed and which have duration spanning several years, at project completion it was determined that several upgrades would improve the overall system performance. Some possible upgrades are discussed. Overall, the system has been very robust, accurate, reproducible, and reliable. The authors found the pencil beam scanning system to be particularly satisfactory; prostate treatments can be delivered on the scanning nozzle in less time than is required on the passive scattering nozzle.

43 PARTICLE ACCELERATORS↗

Structural and impedance properties of KBa{sub 2}V{sub 5}O{sub 15} ceramics

The polycrystalline sample of KBa{sub 2}V{sub 5}O{sub 15} ceramics was prepared by a mixed oxide method at low temperature (i.e., at 560 deg. C). The formation of the compound was confirmed using an X-ray diffraction technique at room temperature. Scanning electron micrograph of the material showed uniform grain distribution on the surface of the sample. Detailed studies of dielectric properties of the compound as a function of temperature at different frequencies suggest that the compound has a dielectric anomaly of ferroelectric to paraelectric type at 323 deg. C, and exhibits diffuse phase transition. Electrical properties of the material were analyzed using a complex impedance technique. The Nyquists plot showed the presence of both grain (>10{sup 3} Hz) and the grain boundary (<10{sup 3} Hz) effects in the material. Studies of electrical conductivity over a wide temperature range suggest that the compound exhibits the negative temperature coefficient of resistance behavior. The ac conductivity spectrum was found to obey Jonscher's universal power law.

36 MATERIALS SCIENCE↗

Structural and Magnetic Properties of Thermal- and Deformation-Induced Martensite in an Fe-27%Ni-4%Mn-1%Zn Alloy

Deformation- and thermal-induced martensite properties were examined according to existing martensite morphology and magnetic properties for same prior austenite homogenization conditions in Fe-27%Ni-4%Mn-1%Zn alloy. Scanning electron microscope (SEM) and vibrating sample magnetometer (VSM) characterization techniques were employed for the investigation. Scanning electron microscope observations showed that while martensite formation in the austenite phase of alloy exhibited a lath morphology by thermal effect, elongated deformation-induced martensite morphology exists after deformation. The Curie temperatures were detected at about 201 K for thermal-induced martensite and at about 226 K for deformation-induced martensite from VSM measurements. The magnetic saturation values were determined as about 21 emu g{sup −1} for thermal-induced martensite and 23 emu g{sup −1} for deformation-induced martensite. We found that magnetic saturation increased with deformation effect. On the other hand, VSM offered the soft ferromagnetic characteristic with coersive values of 36 Oe for thermal-induced martensite and the soft ferromagnetic characteristic with 47 Oe for deformation-induced martensite. The changes in the magnetic properties resulting from the thermal and deformation affect were clearly determined. Deformation caused magnetic stabilization in Fe-27%Ni-4%Mn-1%Zn alloy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-T-375: Passive Scattering to Pencil-Beam-Scanning Comparison for Medulloblastoma Proton Therapy: LET Distributions and Radiobiological Implications

Purpose: To compare the linear energy transfer (LET) distributions between passive scattering and pencil beam scanning proton radiation therapy techniques for medulloblastoma patients and study the potential radiobiological implications. Methods: A group of medulloblastoma patients, previously treated with passive scattering (PS) proton craniospinal irradiation followed by prosterior fossa or involved field boost, were selected from the patient database of our institution. Using the beam geometry and planning computed tomography (CT) image sets of the original treatment plans, pencil beam scanning (PBS) treatment plans were generated for the cranial treatment for each patient, with average beam spot size of 8mm (sigma in air at isocenter). 3-dimensional dose and LET distributions were calculated by Monte Carlo methods (TOPAS) both for the original passive scattering and new pencil beam scanning treatment plans. LET volume histograms were calculated for the target and OARs and compared for the two delivery methods. Variable RBE weighted dose distributions and volume histograms were also calculated using a variable dose and LET-based model. Results: Better dose conformity was achieved with PBS planning compared to PS, leading to increased dose coverage for the boost target area and decreased average dose to the structures adjacent to it and critical structures outside the whole brain treatment field. LET values for the target were lower for PBS plans. Elevated LET values for OARs close to the boosted target areas were noticed, due to end of range of proton beams falling inside these structures, resulting in higher RBE weighted dose for these structures compared to the clinical RBE value of 1.1. Conclusion: Transitioning from passive scattering to pencil beam scanning proton radiation treatment can be dosimetrically beneficial for medulloblastoma patients. LET–guided treatment planning could contribute to better decision making for these cases, especially for critical structures at close proximity to the boosted target area.

60 APPLIED LIFE SCIENCES↗

Automated Scoring of Morphological Changes in Images of Pentaerythritol Tetranitrate

Recent advances in characterization techniques that generate large datasets of material microstructure images require robust, automated image-processing. We applied an unsupervised anomaly detection method called feature anomaly detection system (FADS) to automatically detect and quantify microstructure changes in images of the explosive pentaerythritol tetranitrate (PETN) aged at various temperatures. We demonstrated the FADS approach on two-dimensional images extracted from computed tomography scans, but the same technique can be readily applied to other imaging modalities. FADS calculates anomaly scores on the basis of differences in filter activations of nominal and test data in pretrained convolutional neural networks. The FADS scores successfully differentiated between pristine PETN and PETN aged at a temperature where material coarsening occurred. Morphological metric analysis of segmented images verified observed trends in FADS scores as a function of aging temperature and aging time, specifically by calculating volume fractions, specific boundary lengths, two-point correlation functions, and local thicknesses. Here, the FADS technique has two important advantages compared to traditional morphological analysis: First, it uses grayscale images as input, rather than images that are segmented to separate the appropriate phases; and second, FADS scores capture any type of changes among image sets, rather than requiring prior knowledge or selection of a relevant set of metrics.

Accelerated aging↗

Determination of the magnetic penetration depth in a superconducting Pb film

By means of scanning Hall probe microscopy technique, we accurately map the magnetic field pattern produced by Meissner screening currents in a thin superconducting Pb stripe. The obtained field profile allows us to quantitatively estimate the Pearl length Λ without the need of pre-calibrating the Hall sensor. This fact contrasts with the information acquired through the spatial field dependence of an individual flux quantum where the scanning height and the magnetic penetration depth combine in a single inseparable parameter. The derived London penetration depth λ{sub L} coincides with the values previously reported for bulk Pb once the kinetic suppression of the order parameter is properly taken into account.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Rapid Laser Induced Crystallization of Amorphous NiTi Films Observed by Nanosecond Dynamic Transmission Electron Microscopy (DTEM)

The crystallization processes of the as-deposited, amorphous NiTi thin films have been studied in detail using techniques such as differential scanning calorimetry and, in-situ TEM. The kinetic data have been analyzed in terms of Johnson-Mehl-Avrami-Kolomogrov (JMAK) semi-empirical formula. The kinetic parameters determined from this analysis have been useful in defining process control parameters for tailoring microstructural features and shape memory properties. Due to the commercial push to shrink thin film-based devices, unique processing techniques have been developed using laser-based annealing to spatially control the microstructure evolution down to sub-micron levels. Nanosecond, pulse laser annealing is particularly attractive since it limits the amount of peripheral heating and unwanted microstructural changes to underlying or surrounding material. However, crystallization under pulsed laser irradiation can differ significantly from conventional thermal annealing, e.g., slow heating in a furnace. This is especially true for amorphous NiTi materials and relevant for shape memory thin film based microelectromechanical systems (MEMS) applications. There is little to no data on the crystallization kinetics of NiTi under pulsed laser irradiation, primarily due to the high crystallization rates intrinsic to high temperature annealing and the spatial and temporal resolution limits of standard techniques. However, with the high time and spatial resolution capabilities of the dynamic transmission electron microscope (DTEM) constructed at Lawrence Livermore National Laboratory, the rapid nucleation events occurring from pulsed laser irradiation can be directly observed and nucleation rates can be quantified. This paper briefly explains the DTEM approach and how it used to investigate the pulsed laser induced crystallization processes in NiTi and to determine kinetic parameters.

36 MATERIALS SCIENCE↗

Luminescence-based magnetic imaging with scanning x-ray transmission microscopy

We demonstrate the imaging of the magnetic domain configuration of cobalt structures fabricated on MgO(001) using x-ray induced optical luminescence in a scanning transmission microscope. The technique relies on the measurement of the magnetization-dependent x-ray absorption probed by the optical luminescence radiated from the MgO substrate and induced by the x-rays transmitted through the magnetic layer. This method enables the measurement of the electronic and magnetic spectroscopic properties of single crystalline layers and buried heterostructures with nanometer lateral resolution and elemental sensitivity and opens scanning transmission x-ray microscopy to materials which cannot be grown on membranes or as freestanding thin films.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A study on the structural and mechanical properties of nanocrystalline CuS thin films grown by chemical bath deposition technique

We report a chemical route for the deposition of nanocrystalline thin films of CuS, using aqueous solutions of Cu(CH{sub 3}COO){sub 2}, SC(NH{sub 2}){sub 2} and N(CH{sub 2}CH{sub 2}OH){sub 3} [triethanolamine, i.e. TEA] in proper concentrations and ratios. The films were structurally characterized using X-ray diffraction technique (XRD), field emission scanning electron microscopy (FESEM) and optical analysis [both photo luminescence (PL) and ultraviolet-visible (UV-vis)]. Optical studies showed a large blue shift in the band gap energy of the films due to quantum confinement effect exerted by the nanocrystals. From both XRD and FESEM analyses, formation of CuS nanocrystals with sizes within 10-15 nm was evident. A study on the mechanical properties was carried out using nanoindentation and nanoscratch techniques, which showed good mechanical stability and high adherence of the films with the bottom substrate. Such study on the mechanical properties of the CuS thin films is being reported here for the first time. Current-voltage (I-V) measurements were also carried out for the films, which showed p-type conductivity.

36 MATERIALS SCIENCE↗

Electrochemical behavior of potentiodynamically deposited cobalt oxyhydroxide (CoOOH) thin films for supercapacitor application

Graphical abstract: Scanning electron micrograph (SEM) images of cobalt oxyhydroxide thin film at (a) 2000 Multiplication-Sign and (b) 10,000 Multiplication-Sign magnifications. Highlights: Black-Right-Pointing-Pointer Simple method for the synthesis of CoOOH thin films. Black-Right-Pointing-Pointer Supercapacitor with maximum specific capacitance of 449 F g{sup -1}. Black-Right-Pointing-Pointer High charge/discharge efficiency. -- Abstract: In the present study, we report, for the first time, the synthesis of cobalt oxyhydroxide thin films on inexpensive stainless steel substrate using potentiodynamic electrodeposition method. These films were characterized by X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR) and scanning electron microscopy (SEM) techniques. The orthorhombic crystal structure was revealed by the X-ray diffraction study. The FT-IR spectrum confirmed the formation of cobalt oxyhydroxide. The SEM studies showed the nanoflakes-like morphology with an average thickness of 100 nm. The cyclic voltammetry study of the cobalt oxyhydroxide films in 1 M KOH showed maximum specific capacitance of 449 F g{sup -1} at scan rate of 5 mV s{sup -1}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantification of surface displacements and electromechanical phenomena via dynamic atomic force microscopy

Detection of dynamic surface displacements associated with local changes in material strain provides access to a number of phenomena and material properties. Contact resonance-enhanced methods of atomic force microscopy (AFM) have been shown capable of detecting ~1–3 pm-level surface displacements, an approach used in techniques such as piezoresponse force microscopy, atomic force acoustic microscopy, and ultrasonic force microscopy. Here, based on an analytical model of AFM cantilever vibrations, we demonstrate a guideline to quantify surface displacements with high accuracy by taking into account the cantilever shape at the first resonant contact mode, depending on the tip–sample contact stiffness. The approach has been experimentally verified and further developed for piezoresponse force microscopy (PFM) using well-defined ferroelectric materials. These results open up a way to accurate and precise measurements of surface displacement as well as piezoelectric constants at the pm-scale with nanometer spatial resolution and will allow avoiding erroneous data interpretations and measurement artifacts. Furthermore, this analysis is directly applicable to all cantilever-resonance-based scanning probe microscopy (SPM) techniques.

36 MATERIALS SCIENCE↗

Transmission Kikuchi diffraction and transmission electron forescatter imaging of electropolished and FIB manufactured TEM specimens

We present a study of the efficiency of the utility of scanning electron microscope (SEM)-based transmission methods for characterizing grain structure in thinned bulk metals. Foils of type 316 stainless steel were prepared by two methods commonly used for transmission electron microscopy — double-jet electropolishing and focused ion beam milling. A customized holder allowed positioning of the foils in a configuration appropriate for both transmission electron forward scatter diffraction, and for transmission imaging by the use of a forescatter detector with two diodes. We found that both crystallographic orientation maps and dark-field transmitted images could be obtained for specimens prepared by either method. However, for both methods, preparation-induced artifacts may affect the quality or accuracy of transmission SEM data, especially those acquired by the use of transmission Kikuchi diffraction. Generally, the quality of orientation data was better for specimens prepared by electropolishing, due to the absence of ion-induced damage. - Highlights: • The transmission imaging and diffraction techniques are emerging in scanning electron microscopy (SEM) as promising new field of materials characterization. • The manuscript titled: “Transmission Kikuchi Diffraction and Transmission Electron Forescatter Imaging of Electropolished and FIB Manufactured TEM Specimens” documents how different specimen thinning procedures can effect efficiency of transmission Kikuchi diffraction and transmission electron forescatter imaging. • The abilities to make precision crystallographic orientation maps and dark-field images in transmission was studied on electropolished versus focus ion beam manufactured TEM specimens. • Depending on the need, electropolished and focused ion beam technique may produce suitable specimens for transmission imaging and diffraction in SEM.

36 MATERIALS SCIENCE↗

Low-Voltage Scanning Electron Microscopy and Energy-Dispersive X-Ray Microanalysis of the Interface of Multilayer Polymer Composite

The morphology of the layer of polyelectrolyte complex, which is formed in the composite based on chitosan and sulfoethyl cellulose during the contact of a solution of one of them with a gel film of the other one, has been investigated by the low-voltage (≤3 kV) scanning electron microscopy. A technique for eliminating the effects related to charge accumulation on the dielectric film surface is proposed.

36 MATERIALS SCIENCE↗