Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensitive data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Rapid phylogenetic and functional classification of short genomic fragments with signature peptides

Background: Classification is difficult for shotgun metagenomics data from environments such as soils, where the diversity of sequences is high and where reference sequences from close relatives may not exist. Approaches based on sequence-similarity scores must deal with the confounding effects that inheritance and functional pressures exert on the relation between scores and phylogenetic distance, while approaches based on sequence alignment and tree-building are typically limited to a small fraction of gene families. We describe an approach based on finding one or more exact matches between a read and a precomputed set of peptide 10-mers. Results: At even the largest phylogenetic distances, thousands of 10-mer peptide exact matches can be found between pairs of bacterial genomes. Genes that share one or more peptide 10-mers typically have high reciprocal BLAST scores. Among a set of 403 representative bacterial genomes, some 20 million 10-mer peptides were found to be shared. We assign each of these peptides as a signature of a particular node in a phylogenetic reference tree based on the RNA polymerase genes. We classify the phylogeny of a genomic fragment (e.g., read) at the most specific node on the reference tree that is consistent with the phylogeny of observed signature peptides it contains. Using both synthetic data from four newly-sequenced soil-bacterium genomes and ten real soil metagenomics data sets, we demonstrate a sensitivity and specificity comparable to that of the MEGAN metagenomics analysis package using BLASTX against the NR database. Phylogenetic and functional similarity metrics applied to real metagenomics data indicates a signal-to-noise ratio of approximately 400 for distinguishing among environments. Our method assigns ~6.6 Gbp/hr on a single CPU, compared with 25 kbp/hr for methods based on BLASTX against the NR database. Conclusions: Classification by exact matching against a precomputed list of signature peptides provides comparable results to existing techniques for reads longer than about 300 bp and does not degrade severely with shorter reads. Orders of magnitude faster than existing methods, the approach is suitable now for inclusion in analysis pipelines and appears to be extensible in several different directions.

59 BASIC BIOLOGICAL SCIENCES↗

Log-N/Period Sensitivity Analysis

The Log-N/Period system utilizes a compensated ion chamber to measure neutron radiation in the reactor core. This analysis focuses on determining a more accurate value for the sensitivity of the installed compensated ion chambers for the Log-N/Period system at the ATR. Using calibration procedures a formula for indirectly calculating the sensitivity of the chambers was derived. Using historical data from approximately ten reactor cycles a new average sensitivity for both channels of the Log-N/Period system was determined.

42 ENGINEERING↗

Image-plate sensitivity to x rays at 2 to 60 keV

The sensitivity of Fuji SR and MS image plates (IPs) used in x-ray spectrometers on OMEGA and the National Ignition Facility has been measured using two techniques. A set of radioisotopes has been used to constrain image-plate sensitivity between 6 and 60 keV, while a Manson source has been used to expose image plates to x rays at energies between 1.5 and 8 keV. These data have shown variation in sensitivity on the order of 5% for a given IP type and scanner settings. The radioisotope technique has also been used to assess IP fading properties for MS-type plates over long times. IP sensitivity as a function of scanner settings and pixel size has been systematically examined, showing variations of up to a factor of 2 depending on IP type. Furthermore cross-calibration of IP scanners at different facilities is necessary to produce a consistent absolute sensitivity curve spanning the energy range of 2 to 60 keV.

47 OTHER INSTRUMENTATION↗

Arrangements for communicating data in a computing system using multiple processors

Data employed in computations amongst multiple processors in a computing system is processed so that less bits than a full representation of the data needs to be communicated yet all of the relevant information is communicated. More specifically, a sensitivity value is determined for various items of the data which reflect the number of bits in the data items that are not garbage bits, and only information in the data items that are indicated by the sensitivity value to not be garbage bits are necessarily effectively retained. At least the information that is not garbage bits and the corresponding associated sensitivity are packed together. The results of computations that are performed using the data items as at least one of the operands for the computation are associated with a sensitivity that is derived from the individual sensitivities of the operands used in the computation.

Gonzalez, Juan Guillermo↗

A NOVEL, FULLY AUTOMATED PIPELINE FOR PERIOD ESTIMATION IN THE EROS 2 DATA SET

We present a new method to discriminate periodic from nonperiodic irregularly sampled light curves. We introduce a periodic kernel and maximize a similarity measure derived from information theory to estimate the periods and a discriminator factor. We tested the method on a data set containing 100,000 synthetic periodic and nonperiodic light curves with various periods, amplitudes, and shapes generated using a multivariate generative model. We correctly identified periodic and nonperiodic light curves with a completeness of ∼90% and a precision of ∼95%, for light curves with a signal-to-noise ratio (S/N) larger than 0.5. We characterize the efficiency and reliability of the model using these synthetic light curves and apply the method on the EROS-2 data set. A crucial consideration is the speed at which the method can be executed. Using a hierarchical search and some simplification on the parameter search, we were able to analyze 32.8 million light curves in ∼18 hr on a cluster of GPGPUs. Using the sensitivity analysis on the synthetic data set, we infer that 0.42% of the sources in the LMC and 0.61% of the sources in the SMC show periodic behavior. The training set, catalogs, and source code are all available at http://timemachine.iic.harvard.edu.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An atmospheric pressure high-temperature laminar flow reactor for investigation of combustion and related gas phase reaction systems

A new high-temperature flow reactor experiment utilizing the powerful molecular beam mass spectrometry (MBMS) technique for detailed observation of gas phase kinetics in reacting flows is presented. The reactor design provides a consequent extension of the experimental portfolio of validation experiments for combustion reaction kinetics. Temperatures up to 1800 K are applicable by three individually controlled temperature zones with this atmospheric pressure flow reactor. Detailed speciation data are obtained using the sensitive MBMS technique, providing in situ access to almost all chemical species involved in the combustion process, including highly reactive species such as radicals. Strategies for quantifying the experimental data are presented alongside a careful analysis of the characterization of the experimental boundary conditions to enable precise numeric reproduction of the experimental results. The general capabilities of this new analytical tool for the investigation of reacting flows are demonstrated for a selected range of conditions, fuels, and applications. A detailed dataset for the well-known gaseous fuels, methane and ethylene, is provided and used to verify the experimental approach. Furthermore, application for liquid fuels and fuel components important for technical combustors like gas turbines and engines is demonstrated. Besides the detailed investigation of novel fuels and fuel components, the wide range of operation conditions gives access to extended combustion topics, such as super rich conditions at high temperature important for gasification processes, or the peroxy chemistry governing the low temperature oxidation regime. These demonstrations are accompanied by a first kinetic modeling approach, examining the opportunities for model validation purposes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nuclear data uncertainties by the PWR MOX/UO{sub 2} core rod ejection benchmark

Rod ejection transient of the OECD/NEA and U.S. NRC PWR MOX/UO{sub 2} core benchmark is considered under the influence of nuclear data uncertainties. Using the GRS uncertainty and sensitivity software package XSUSA the propagation of the uncertainties in nuclear data up to the transient calculations are considered. A statistically representative set of transient calculations is analyzed and both integral as well as local output quantities are compared with the benchmark results of different participants. It is shown that the uncertainties in nuclear data play a crucial role in the interpretation of the results of the simulation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Amplified luminescence in organo-curium nanocrystal hybrids

We present here the first report of ligand-sensitized, actinide luminescence in a lanthanide nanoparticle host. Amplified luminescence of 248 Cm 3+ doped in a NaGdF 4 lattice is achieved through optical pumping of a surface-localized metal chelator, 3,4,3-LI(1,2-HOPO), capable of sensitizing Cm 3+ excited states. The data suggest the possibility of using such materials in theranostic applications, with a ligand-sensitized actinide or radio-lanthanide serving the dual roles of a nuclear decay source for radiotherapeutics, and as a luminescent center or energy transfer conduit to another emissive metal ion, for biological imaging.

36 MATERIALS SCIENCE↗

Second ARM Aerosol Chemical Speciation Monitor Users’ Meeting Report

The aerosol chemical speciation monitor (ACSM) was developed to adapt the technology of the aerosol mass spectrometer (AMS) to routine, long-term, standalone monitoring. The calculation of particulate mass concentration from ACSM data requires the measurement of the response of the instrument to aerosol of specific size and composition as well as assumptions about the instrument response based on laboratory measurements and field experience acquired over more than two decades of operation of AMS and a decade of operation of the ACSM. Three parameters in the concentration calculations that are particularly important are the NO3 response factor (RFNO3), relative ionization efficiency (RIE), and the collection efficiency (CE). The values of RFNO3 and RIEs are determined from calibration, however the jump calibration method previously used in calibration can result in errors in the RIE for sulfate. This has been corrected by implementing a continuous calibration method. The default collection efficiency is 0.5. This has been shown to result in mass loadings that do not agree with mass determinations from other instruments because of effects of composition on the vaporization of the particles. The previous work of investigators addressing this issue is discussed. After preliminary work on ACSM and scanning mobility particle sizer (SMPS) data from the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) observatory collected in late 2016 and 2017 produced a parameterization of composition dependent collection efficiency very different from the results of previous studies, SMPS data were examined and we determined that there was significant mass that the instrument did not capture because the particles with diameters larger than 465 nm are not counted by this instrument. Data for the ultra-high-sensitivity aerosol spectrometer (UHSAS), SMPS, and ACSM are available for nearly all of 2019. The data from UHSAS and SMPS collected in 2019 were compared. We found that the UHSAS data has particle counts and total volumes significantly less than measured by the condensation particle counter (CPC) and SMPS. The SMPS data were extended by fitting the average volume distribution with a log normal curve and using this relationship to estimate a mass value for the SMPS over extended diameter range. The extended SMPS mass values result in a CDCE parameterization that is in better agreement with the results of other investigators, but is still different from other formulations. The working group recommends that the ACSM data be processed with a collective efficiency (CE)=1, that this be documented clearly in the metadata, and the use of the default CE of 0.5 or a formulation of composition-dependent collection efficiencies (CDCE) chosen by the user should be implemented based on the ammonium nitrate mass fraction. This is clearly necessary for the wintertime SGP ACSM data because of the high nitrate concentrations.

47 OTHER INSTRUMENTATION↗

Sensitivity Coefficients Calculated for the Prompt Neutron Decay Constant at or Near Delayed Critical [Abstract]

Experimenters at Los Alamos National Laboratory (LANL) measure the prompt neutron decay constant for many experiments at the National Criticality Experiments Research Center (NCERC) to infer reactivity and the effective neutron multiplication factor. These quantities are very important for nuclear criticality safety and validating nuclear data. Uncertainty in measures of criticality of an experimental configuration can be determined prior to physically performing the experiment by applying first order perturbation theory to Monte Carlo codes, such as MCNP®. The first order perturbation theory produces first derivatives of some nuclear parameter to nuclear data (e.g., cross section data). This first derivative is commonly referred to as a sensitivity coefficient. Currently, the MCNP® software has the capability of computing effective neutron multiplication factor sensitivity coefficients to cross section data. This work builds off of this MCNP® capability and the first order perturbation theory to provide a method of calculating sensitivity coefficients for the prompt neutron decay constant at or near delayed critical to cross section data. The prompt neutron decay constant sensitivity coefficient calculated in this work does not depend on any modification of the MCNP® source code. Prompt neutron decay constant sensitivity coefficient calculations can be used to infer reactivity and effective neutron multiplication factor sensitivity coefficient values as well. By investigating the trends of prompt neutron decay constant sensitivity coefficients for nuclide-reaction pairs across energy spectra, experiments can be designed to maximize or minimize the uncertainty in the prompt neutron decay constant in a particular energy region, which can lead to further optimization studies. Prompt neutron decay constant sensitivity coefficients will be calculated for the Jezebel benchmark. Subsequently, these sensitivity coefficients will be used in a data assimilation process to determine if there is or are optimal experiments that can be performed to provide insight into adjustments of uncertain/inaccurate cross section data. Specifically, the effect of the prompt neutron decay constant sensitivity coefficients on the nuclear data-induced uncertainty in the effective neutron multiplication factor will be examined

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

From sequence to protein structure and conformational dynamics with artificial intelligence/machine learning

The 2024 Nobel Prize in Chemistry was awarded in part for de novo protein structure prediction using AlphaFold2, an artificial intelligence/machine learning (AI/ML) model trained on vast amounts of sequence and three-dimensional structure data. AlphaFold2 and related models, including RoseTTAFold and ESMFold, employ specialized neural network architectures driven by attention mechanisms to infer relationships between sequence and structure. At a fundamental level, these AI/ML models operate on the long-standing hypothesis that the structure of a protein is determined by its amino acid sequence. More recently, AlphaFold2 has been adapted for the prediction of multiple protein conformations by subsampling multiple sequence alignments. Herein, we provide an overview of the deterministic relationship between sequence and structure, which was hypothesized over half a century ago with profound implications for the biological sciences ever since. We postulate that protein conformational dynamics are also determined, at least in part, by amino acid sequence and that this relationship may be leveraged for construction of AI/ML models dedicated to predicting protein conformational ensembles. Accordingly, we describe a conceptual model architecture, which may be trained on sequence data in combination with conformationally sensitive structural information, coming primarily from nuclear magnetic resonance (NMR) spectroscopy. Notwithstanding certain limitations in this context, NMR offers abundant structural heterogeneity conducive to conformational ensemble prediction. As NMR and other data continue to accumulate, sequence-informed prediction of protein structural dynamics with AI/ML has the potential to emerge as a transformative capability across the biological sciences.

Artificial intelligence↗

MHz gravitational wave constraints with decameter Michelson interferometers

A new detector, the Fermilab Holometer, consists of separate yet identical 39-meter Michelson interferometers. Strain sensitivity achieved is better than 10 –21 /√Hz between 1 to 13 MHz from a 130-h data set. This measurement exceeds the sensitivity and frequency range made from previous high frequency gravitational wave experiments by many orders of magnitude. Constraints are placed on a stochastic background at 382 Hz resolution. The 3σ upper limit on Ω GW , the gravitational wave energy density normalized to the closure density, ranges from 5.6 × 10 12 at 1 MHz to 8.4 × 10 15 at 13 MHz. Another result from the same data set is a search for nearby primordial black hole binaries (PBHB). There are no detectable monochromatic PBHBs in the mass range 0.83–3.5 × 10 21 g between the Earth and the Moon. Projections for a chirp search with the same data set increase the mass range to 0.59–2.5 × 10 25 g and distances out to Jupiter. Furthermore, this result presents a new method for placing limits on a poorly constrained mass range of primordial black holes. Additionally, solar system searches for PBHBs place limits on their contribution to the total dark matter fraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LITTLE THINGS

We present LITTLE THINGS (Local Irregulars That Trace Luminosity Extremes, The H I Nearby Galaxy Survey), which is aimed at determining what drives star formation in dwarf galaxies. This is a multi-wavelength survey of 37 dwarf irregular and 4 blue compact dwarf galaxies that is centered around H I-line data obtained with the National Radio Astronomy Observatory (NRAO) Very Large Array (VLA). The H I-line data are characterized by high sensitivity ({<=}1.1 mJy beam{sup -1} per channel), high spectral resolution ({<=}2.6 km s{sup -1}), and high angular resolution ({approx}6''). The LITTLE THINGS sample contains dwarf galaxies that are relatively nearby ({<=}10.3 Mpc; 6'' is {<=}300 pc), that were known to contain atomic hydrogen, the fuel for star formation, and that cover a large range in dwarf galactic properties. We describe our VLA data acquisition, calibration, and mapping procedures, as well as H I map characteristics, and show channel maps, moment maps, velocity-flux profiles, and surface gas density profiles. In addition to the H I data we have GALEX UV and ground-based UBV and H{alpha} images for most of the galaxies, and JHK images for some. Spitzer mid-IR images are available for many of the galaxies as well. These data sets are available online.

79 ASTRONOMY AND ASTROPHYSICS↗

Updates and Validation for the n+ 63,65 Cu Cross Sections [Abstract]

The neutron induced total, elastic, and capture cross sections of 63,65 Cu isotopes were selected for evaluation in the resolved and unresolved resonance energy ranges by the National Criticality Safety Program to resolve discrepancies related to benchmark performance. This is especially evident for the series of ZEUS benchmarks in which copper is used as a reflector. Because copper is also used as structural material in both fission and fusion reactors, the need to address benchmark discrepancies linked to nuclear data deficiencies is a task of primary importance. The aim of this work is to describe the steps of evaluation work towards a consistent improvement of the benchmark performance. The R-matrix analysis with the SAMMY code focused on the 63 Cu(n,γ) reaction channel between 100-300 keV coupled to unresolved resonance region parameters up to 650 keV to fit average cross section data from a recent experiment. Due to the high sensitivity of many benchmarks to elastic scattering angular distribution data, especially for the 65 Cu isotope, the impact of these data was tested by generating Legendre coefficients from both resonance parameters and the Hauser-Feshbach model. Guided by the findings of Shaw et al., the performance of the current evaluation for 65 Cu was compared to that of ENDF/B-VII.1 and ENDF/B-VIII.0 by testing the reactivity coefficients corresponding to the validation suite of experimental criticality benchmarks for thermal, intermediate, and fast systems taken from the International Criticality Safety Benchmark Experiments Project Handbook. The benchmark performance is especially sensitive to 63 Cu(n,γ) and 65 Cu elastic scattering for neutron energies in the 100–500 keV region, whereas 100 keV is the upper limit of the resolved resonance region in the ENDF/B-VIII.0 evaluations for 63,65 Cu. The results highlight the need to handle the transition from the resolved resonance region to the high energy region carefully.

07 ISOTOPE AND RADIATION SOURCES↗

Deuterium-tritium neutron yield measurements with the 4.5 m neutron-time-of-flight detectors at NIF

The first several campaigns of laser fusion experiments at the National Ignition Facility (NIF) included a family of high-sensitivity scintillator/photodetector neutron-time-of-flight (nTOF) detectors for measuring deuterium-deuterium (DD) and DT neutron yields. The detectors provided consistent neutron yield (Y{sub n}) measurements from below 10{sup 9} (DD) to nearly 10{sup 15} (DT). The detectors initially demonstrated detector-to-detector Y{sub n} precisions better than 5%, but lacked in situ absolute calibrations. Recent experiments at NIF now have provided in situ DT yield calibration data that establish the absolute sensitivity of the 4.5 m differential tissue harmonic imaging (DTHI) detector with an accuracy of {+-}10% and precision of {+-}1%. The 4.5 m nTOF calibration measurements also have helped to establish improved detector impulse response functions and data analysis methods, which have contributed to improving the accuracy of the Y{sub n} measurements. These advances have also helped to extend the usefulness of nTOF measurements of ion temperature and downscattered neutron ratio (neutron yield 10-12 MeV divided by yield 13-15 MeV) with other nTOF detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostic Models for Wind Turbine Gearbox Components Using SCADA Time Series Data: Preprint

This paper presents a scalable, autonomous framework for diagnostics of wind turbine gearbox failures using a multi-feature supervisory control and data acquisition data set spanning multiple years. Because of the size of the data set studied, all algorithms were constructed to be scalable using a Spark-Hadoop data framework. An unsupervised approach was used to detect significant failures based on predetermined criteria. The initial criteria selected were an abnormal spike in turbine component temperature followed by a turbine power off, which helps reduce the number of potential false alarms. To detect abnormal spikes in component temperature, a model was introduced to adjust the temperature data for effects caused by ambient temperature and normal temperature increases when loaded. This study evaluates methods for normalizing temperature sensor data to identify anomalies. The models that performed the best were a linear regression and a multivariate polynomial regression. The proposed process for finding failures has tunable parameters that can be adjusted to be more or less sensitive. The combination of sensor data normalization and application of these criteria is successful in finding turbine failures resulting in downtime. The proposed methods can operate without failure or maintenance logs and can be utilized for offline analysis of large high-resolution data sets.

17 WIND ENERGY↗