Search NASA⌕ Search

SEARCH · Search NASA

Results for “Software development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

SU-F-R-25: Automatic Identification of Suspicious Recurrent/residual Disease Regions After Prostatectomy

Purpose: To automatically identify and outline suspicious regions of recurrent or residual disease in the prostate bed using Dynamic Contrast Enhanced-MRI (DCE-MRI) in patients after prostatectomy. Methods: Twenty-two patients presenting for salvage radiotherapy and with identified Gross Tumor Volume (GTV) in the prostate bed were retrospectively analyzed. The MRI data consisted of Axial T2weighted-MRI (T2w) of the pelvis: resolution 1.25×1.25×2.5 mm; Field of View (FOV): 320×320 mm; slice thickness=2.5mm; 72 slices; and Dynamic Contrast Enhanced MRI (DCE-MRI)–12 series of T1w with identical spatial resolution to T2w and at 30–34s temporal resolution. Unsupervised pattern recognition was used to decompose the 4D DCE data as the product W.H of weights W of k patterns H. A well-perfused pattern Hwp was identified and the weight map Wwp associated to Hwp was used to delineate suspicious volumes. Threshold of Wwp set at mean(Wwp)+S*std(Wwp), S=1,1.5,2 and 2.5 defined four volumes labeled as DCE1.0 to DCE2.5. These volumes were displayed on T2w and, along with GTV, were correlated with the highest pre-treatment PSA values, and with pharmacokinetic analysis constants. Results: GTV was significantly correlated with DCE2.0(ρ= 0.60, p<0.003), and DCE 2.5 (ρ=0.58, p=0.004)). Significant correlation was found between highest pre-treatment PSA and GTV(ρ=0.42, p<0.049), DCE2.0(ρ= 0.52, p<0.012), and DCE 2.5 (ρ=0.67, p<<0.01)). Kruskal-Wallis analysis showed that Ktrans median value was statistically different between non-specific prostate bed tissue NSPBT and both GTV (p<<0.001) and DCE2.5 (p<<0.001), but while median Ve was statistically different between DCE2.5 and NSPBT (p=0.002), it was not statistically different between GTV and NSPBT (p=0.054), suggesting that automatic volumes capture more accurately the area of malignancy. Conclusion: Software developed for identification and visualization of suspicions regions in DCE-MRI from post-prostatectomy patients has been validated by PSA and pharmacokinetic constants analysis showing that it generates clinically relevant volumes.

60 APPLIED LIFE SCIENCES↗

SU-F-R-45: The Prognostic Value of Radiotherapy Based On the Changes of Texture Features Between Pre-Treatment and Post-Treatment FDG PET Image for NSCLC Patients

Purpose: The purpose of this research is investigating which texture features extracted from FDG-PET images by gray-level co-occurrence matrix(GLCM) have a higher prognostic value than the other texture features. Methods: 21 non-small cell lung cancer(NSCLC) patients were approved in the study. Patients underwent 18F-FDG PET/CT scans with both pre-treatment and post-treatment. Firstly, the tumors were extracted by our house developed software. Secondly, the clinical features including the maximum SUV and tumor volume were extracted by MIM vista software, and texture features including angular second moment, contrast, inverse different moment, entropy and correlation were extracted using MATLAB.The differences can be calculated by using post-treatment features to subtract pre-treatment features. Finally, the SPSS software was used to get the Pearson correlation coefficients and Spearman rank correlation coefficients between the change ratios of texture features and change ratios of clinical features. Results: The Pearson and Spearman rank correlation coefficient between contrast and SUV maximum is 0.785 and 0.709. The P and S value between inverse difference moment and tumor volume is 0.953 and 0.942. Conclusion: This preliminary study showed that the relationships between different texture features and the same clinical feature are different. Finding the prognostic value of contrast and inverse difference moment were higher than the other three textures extracted by GLCM.

60 APPLIED LIFE SCIENCES↗

SU-G-BRB-17: Dosimetric Evaluation of the Respiratory Interplay Effect During VMAT Delivery Using IPAGAT Polymer Gel Dosimeter

Purpose: To evaluate the dosimetric impact of the interplay effect between multileaf collimator (MLC) movement and tumor respiratory motion during delivery of volumetric modulate arc therapy (VMAT) by using customized polymer gel dosimeter. Methods: Polyacrylamide-based gel dosimeter contained magnesium chloride as a sensitizer (iPAGAT) was used in this study. An excellent gas barrier PAN (BAREX) techno bottle (φ8 cm, 650 mL) filled with iPAGAT was set to the QUASAR™ respiratory motion phantom, and was moved with motion amplitudes of 1 and 2 cm with a 4 second period during VMAT delivery by the Novalis Tx linear accelerator (Varian/BrainLAB). Two spherical tumors with a 2 cm diameter (GTV1 and GTV2) were defined, and ITV1 (GTV1+1 cm) and ITV2 (GTV2+2 cm) with expansion in the superior-inferior (S-I) direction were also defined with simulated respiratory motion. PTV margin was 2 mm around the ITV considering the setup uncertainty. Two single arc VMAT plans with 30 Gy at 3 Gy per fraction (GTV: D98>100%, PTV: D95=100%) were generated by the Varian Eclipse treatment planning system. Three-dimensional dose distribution in iPAGAT was read out by the Signa 1.5T MRI system (GE), and was evaluated by dose-volume histogram (DVH) using in-house developed software. Results: According to DVH analysis by iPAGAT, D98 of GTV1 and GTV2 were more than 100% of the prescribed dose. In contrast, D95 of PTV1 and PTV2 were about 85% and 65%, respectively. Furthermore, low-to-intermediate dose was widespread with motion amplitude of 2 cm. Conclusion: DVH analysis using iPAGAT polymer gel dosimeter was performed in this study. As a result, interplay effect was negligible, since dose coverage of GTV was sufficient during VMAT delivery with simulated respiratory motion. However, the dose reduction of PTV and the spread of low-to-intermediate dose compared to the planned dose require scrupulous attention for large tumor respiratory motion.

60 APPLIED LIFE SCIENCES↗

WE-FG-BRA-04: A Portable Confocal Microscope to Image Live Cell Damage Response Induced by Therapeutic Radiation

Purpose: To construct a custom and portable fluorescence confocal laser-scanning microscope (FCLSM) that can be placed in the path of therapeutic radiation beams to study real-time radiation-induced damage response in live cells. Methods: We designed and constructed a portable FCLSM with three laser diodes for excitation (405, 488, and 635 nm). An objective lens focuses the excitation light and collects fluorescence from the sample. A pair of galvanometer mirrors scans/collects the laser beam/fluorescence along the focal plane (x/y-directions). A stepper motor stage scans in the axial direction and positions the x/y of the image field. Barrier filters and dichroic mirrors are used to route the spectral emission bands to the appropriate photodetector. An avalanche photodiode collects near-infrared fluorescence; a photodiode collects back-reflected 635 nm light; and a photomultiplier tube collects green fluorescence in the range of eGFP/eYFP. A 200-µm diameter pinhole was used to implement the confocal geometry for near-infrared and red channels and a 150-µm diameter pinhole for the green channel. Data acquisition and system control were achieved using a high-throughput data acquisition card. In-house software developed in LabVIEW was used to control the hardware, collect data from the photodetectors and reconstruct the confocal images. Results: 6 frames/s can be acquired for a 25 µm{sup 2} (128×128 pixels) field of view, visualizing the entire volume of the cell nucleus (∼10 µm depth) in <10 s. To demonstrate the usefulness of our FCLSM, we imaged gold nanoshells in live cells, radiation-induced damage in fibrosarcoma cells expressing eGFP tagged to a DNA repair protein, and neurons expressing eGFP. The system can also image particle tracks in fluorescent nuclear track detectors. Conclusion: We developed a versatile and portable FCLSM that allows radiobiology studies in live cells exposed to therapeutic radiation. The FCLSM can be placed in any vertical beam line for top-to-bottom exposures. This research was supported by the Sister Institution Network Fund and the Center for Radiation Oncology Research at The University of Texas MD Anderson Cancer Center and Cancer Prevention and Research Institute of Texas. Gabriel Sawakuchi has research support from Elekta Inc.

60 APPLIED LIFE SCIENCES↗

Resonant ultrasound spectroscopy probe for in-situ neutron scattering measurements

Resonant ultrasound spectroscopy (RUS) is an efficient, nondestructive technique to study the elastic properties of solids. A low-temperature (2-300 K) probe has been assembled and tested at the NOMAD beamline at the Spallation Neutron Source at Oak Ridge National Laboratory to assess the probe's neutronic properties, data acquisition system, and compatibility with existing sample environment. A case study on a bulk metallic glass, La 65 Cu 20 Al 10 Co 5, served to benchmark both hardware and software developments. The elastic constants of the metallic glass were determined as a function of temperature between 4 and 300 K and were used to guide neutron diffraction measurements at NOMAD. Tracking of a specific RUS peak center frequency and width enabled live monitoring of the sample temperature evolution that lagged thermometry by upwards of 40 K near room temperature. Assembly of a high-temperature (300-875 K) probe is underway and both probes are scheduled to be available to users by late-2021. Our aim is to provide users with live monitoring of an intrinsic variable at the neutron scattering beamlines, in addition to existing controls, to monitor the state of their samples and its elastic moduli and make informed decisions in real time.

Torres, James↗

Addressing the dynamic nature of reference data: a new nucleotide database for robust metagenomic classification

Accurate metagenomic classification relies on comprehensive, up-to-date, and validated reference databases. While the NCBI BLAST Nucleotide (nt) database, encompassing a vast collection of sequences from all domains of life, represents an invaluable resource, its massive size—currently exceeding 10 12 nucleotides—and exponential growth pose significant challenges for researchers seeking to maintain current nt-based indices for metagenomic classification. Recognizing that no current nt-based indices exist for the widely used Centrifuge classifier, and the last public version currently available was released in 2018, we addressed this critical gap by leveraging advanced high-performance computing resources. We present new Centrifuge-compatible nt databases, meticulously constructed using a novel pipeline incorporating different quality control measures, including reference decontamination and filtering. These measures demonstrably reduce spurious classifications, as shown through our reanalysis of published metagenomic data where Plasmodium annotations were dramatically reduced using our decontaminated database, highlighting how database quality can significantly impact research conclusions. Through temporal comparisons, we also reveal how our approach minimizes inconsistencies in taxonomic assignments stemming from asynchronous updates between public sequence and taxonomy databases. These discrepancies are particularly evident in taxa such as Listeria monocytogenes and Naegleria fowleri, where classification accuracy varied significantly across database versions. These new databases, made available as pre-built Centrifuge indexes, respond to the need for an open, robust, nt-based pipeline for taxonomic classification in metagenomics. Applications such as environmental metagenomics, forensics, and clinical metagenomics, which require comprehensive taxonomic coverage, will benefit from this resource. Our work highlights the importance of treating reference databases as dynamic entities, subject to ongoing quality control and validation akin to software development best practices. This approach is crucial for ensuring accuracy and reliability of metagenomic analysis, especially as databases continue to expand in size and complexity.

59 BASIC BIOLOGICAL SCIENCES↗

The status of MCU-5

The software developed within the framework of the MCU project which implements the Monte Carlo method for solving the transport equations for various kinds of radiation is widely used for calculating nuclear reactors of different types. The final version of MCU-5 is described. The developed libraries of constants are briefly described, and the potentialities of the MCU-5 package modules and the executable codes compiled from them are characterized. Examples of important problems of reactor physics solved with the codes from the MCU family are presented.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The dubna gas-filled recoil separator: Software and algorithms

Experiments carried out on the gas-filled separator of recoil nuclei at the Flerov Laboratory of Nuclear Reactions, Joint Institute for Nuclear Research, in the past several years have proved the hypothesis of the existence of a stability island of superheavy nuclei. The accelerator, beam diagnostics, and detector technologies underlay the success. It is the highly sensitive detecting system of the separator combined with the method of “active correlations” that allowed rare events of the decay of superheavy nuclei to be reliably detected under almost background-free conditions. In turn, to a large extent, this has been made possible owing to special algorithms and software developed for long-term experiments in the beam of {sup 48}Ca ions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Das ist der HAMMER: consistent new physics interpretations of semileptonic decays

Abstract Precise measurements of $$b\rightarrow c\tau \bar{\nu }$$ b → c τ ν ¯ decays require large resource-intensive Monte Carlo (MC) samples, which incorporate detailed simulations of detector responses and physics backgrounds. Extracted parameters may be highly sensitive to the underlying theoretical models used in the MC generation. Because new physics (NP) can alter decay distributions and acceptances, the standard practice of fitting NP Wilson coefficients to SM-based measurements of the $$R(D^{(*)})$$ R ( D ( ∗ ) ) ratios can be biased. The newly developed software tool enables efficient reweighting of MC samples to arbitrary NP scenarios or to any hadronic matrix elements. We demonstrate how allows avoidance of biases through self-consistent fits directly to the NP Wilson coefficients. We also present example analyses that demonstrate the sizeable biases that can otherwise occur from naive NP interpretations of SM-based measurements. The library is presently interfaced with several existing experimental analysis frameworks and we provide an overview of its structure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Static analysis techniques for semiautomatic synthesis of message passing software skeletons

The design of high-performance computing architectures demands performance analysis of large-scale parallel applications to derive various parameters concerning hardware design and software development. The process of performance analysis and benchmarking an application can be done in several ways with varying degrees of fidelity. One of the most cost-effective ways is to do a coarse-grained study of large-scale parallel applications through the use of program skeletons. The concept of a “program skeleton” that we discuss in this article is an abstracted program that is derived from a larger program where source code that is determined to be irrelevant is removed for the purposes of the skeleton. In this work, we develop a semiautomatic approach for extracting program skeletons based on compiler program analysis. Finally, we demonstrate correctness of our skeleton extraction process by comparing details from communication traces, as well as show the performance speedup of using skeletons by running simulations in the SST/macro simulator.

97 MATHEMATICS AND COMPUTING↗

An LLVM Instrumentation Plug-in for Score-P

Reducing application runtime, scaling parallel applications to higher numbers of processes/threads, and porting applications to new hardware architectures are tasks necessary in the software development process. Therefore, developers have to investigate and understand application runtime behavior. Tools such as monitoring infrastructures that capture performance relevant data during application execution assist in this task. The measured data forms the basis for identifying bottlenecks and optimizing the code.Monitoring infrastructures need mechanisms to record application activities in order to conduct measurements. Automatic instrumentation of the source code is the preferred method in most application scenarios. We introduce a plug-in for the LLVM infrastructure that enables automatic source code instrumentation at compile-time. In contrast to available instrumentation mechanisms in LLVM/Clang, our plug-in can selectively include/exclude individual application functions. This enables developers to fine-tune the measurement to the required level of detail while avoiding large runtime overheads due to excessive instrumentation.

Tschüter, Ronny↗

Reliability Analysis for Unreliable FSM Computations

Finite State Machines (FSMs) are fundamental in both hardware design and software development. However, the reliability of FSM computations remains poorly understood. This becomes increasingly critical as the technology scaling becomes more aggressive. Existing reliability analyses are mainly designed for generic computations and are unaware of the special error tolerance characteristics in FSM computations. In this work, we introduce RelyFSM – a state-level reliability analysis framework for FSM computations. By qualitatively reasoning about the transition structures in FSM computations, RelyFSM can precisely capture their inherent error tolerance. Basically, RelyFSM takes an FSM specification as input and analyzes its reliability for a specific execution. At the core of the analysis is a set of mathematical models that accurately define the behaviors of unreliable FSM executions. Our evaluation with a spectrum of FSM benchmarks confirms the accuracy and efficiency of RelyFSM in analyzing the reliability of real-world FSM computations.

97 MATHEMATICS AND COMPUTING↗

MemAxes Visualization Software

Hardware advancements such as Intel's PEBS and AMD's IBS, as well as software developments such as the perf_event API in Linux have made available the acquisition of memory access samples with performance information. MemAxes is a visualization and analysis tool for memory access sample data. By mapping the samples to their associated code, variables, node topology, and application dataset, MemAxes provides intuitive views of the data.

Source record↗

USGIN Lab site

This web site provides information related to service profiles and implementation in development for the US Geoscience information network (USGIN). It is meant to be a site where developers can learn about the standard in use, the objectives of the application profiles being developed, software being used or tested for implementation of services, and details about particular implementations. Forums are provided for asking questions about the services, profiles, and implemenation issues.

Clark, Ryan↗

PNNL OMICS

The PNNL Omics Library (PNNLOmics.dll) is a collection of data analysis, file I/O, and visualization routines used by several of the omics-related software developed at PNNL.

Degan, Michael↗

Java Software Extensibility Library

The Java Software Extensibility Library provides tools that help Java software developers produce flexible and extensible Java applications. The major components include a Plugin Library and a Polymorphic Map data structure. The Plugin Library provides developers with a Plugin Registry and a standard pattern for designing, versioning, registering, retrieving, and annotating plugins. It also enables advanced capabilities such as loading plugins at runtime, and creating/loading encrypted plugin packages. The Polymorphic Map data structure facilitates the storage and retrieval of objects of varying types within a single data structure; while maintaining type safety. The library also provides a standard design pattern for producing application-specific "Domain Maps" and "Closed Domain Maps".SAND2020-3816 M Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Fleschute, Christopher↗

Alquimia

Alquimia provides a generic interface between flow and transport simulators (drivers) and biogeochemical reaction capabilities (engines). Alquimia consists of two parts: an application programming interface, API, and a wrapper library. The API describes in detail how information is exchanged between the driver and the engine. This includes the function call signatures and data structures required for implementing alquimia in a mixed language (C/C++/Fortran) programming environment. The library is an implementation of the documented API, providing an interface into the biogeochemistry routines supplied by other codes: Alquimia does not do any geochemical calculations. Version 1.0 provides interfaces to the open source codes (BSD) CrunchFlow/CrunchTope and (LGPL) PFLOTRAN. Version 1.0 meets the policies set forth by (and is part of) the Extreme-scale Scientific Software Development Kit, xSDK version 0.6.0.

Andre, Benjamin [Lawrence Berkeley National Lab. (↗