Search NASA⌕ Search

SEARCH · Search NASA

Results for “Standard deviation modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Anisotropic physics-regularized interpretable machine learning of microstructure evolution

Anisotropic Physics-Regularized Interpretable Machine Learning Microstructure Evolution (APRIMME) is a general-purpose machine learning solution for grain growth simulations. In prior work, PRIMME employed a deep neural network to predict site-specific migration as a function of its neighboring sites to model normal, isotropic, grain growth behavior. This work aims to extend this method by incorporating grain boundary misorientation-based grain growth behavior. APRIMME is trained on anisotropic simulations created using the Monte Carlo-Potts (MCP) model. Furthermore, the results of this work are compared statistically using grain radius, number of sides per grain, mean neighborhood misorientations, and the standard deviation of triple junction dihedral angles, and are found to match in most cases. The exceptions are small and seem to be related to two causes: (1) the deterministic model of APRIMME is learning from the stochastic simulations of MCP, which seems to accentuate triple junction behaviors; and, (2) a bias against very small grains is made evident in a quicker decrease in grains than expected at the beginning of an APRIMME simulation. APRIMME is also evaluated for its general ability to capture anisotropic grain growth behavior by first investigating different test case initial conditions, including a circle grain, three grain, and hexagonal grain microstructures.

36 MATERIALS SCIENCE↗

Constraints on deviations from ΛCDM within Horndeski gravity

Recent anomalies found in cosmological datasets such as the low multipoles of the Cosmic Microwave Background or the low redshift amplitude and growth of clustering measured by e.g., abundance of galaxy clusters and redshift space distortions in galaxy surveys, have motivated explorations of models beyond standard ΛCDM. Of particular interest are models where general relativity (GR) is modified on large cosmological scales. Here we consider deviations from ΛCDM+GR within the context of Horndeski gravity, which is the most general theory of gravity with second derivatives in the equations of motion. We adopt a parametrization in which the four additional Horndeski functions of time α{sub i}(t) are proportional to the cosmological density of dark energy Ω{sub DE}(t). Constraints on this extended parameter space using a suite of state-of-the art cosmological observations are presented for the first time. Although the theory is able to accommodate the low multipoles of the Cosmic Microwave Background and the low amplitude of fluctuations from redshift space distortions, we find no significant tension with ΛCDM+GR when performing a global fit to recent cosmological data and thus there is no evidence against ΛCDM+GR from an analysis of the value of the Bayesian evidence ratio of the modified gravity models with respect to ΛCDM, despite introducing extra parameters. The posterior distribution of these extra parameters that we derive return strong constraints on any possible deviations from ΛCDM+GR in the context of Horndeski gravity. We illustrate how our results can be applied to a more general frameworks of modified gravity models.

79 ASTRONOMY AND ASTROPHYSICS↗

A two-step short-term probabilistic wind forecasting methodology based on predictive distribution optimization

With increasing wind penetrations into electric power systems, probabilistic wind forecasting becomes more critical to power system operations because of its capability of quantifying wind uncertainties. In this paper, a two-step probabilistic wind forecasting approach based on pinball loss optimization is developed. First, a multimodel machine learning-based ensemble deterministic forecasting framework is adopted to generate deterministic forecasts. The deterministic forecast is assumed to be the mean value of the predictive distribution at each forecasting time stamp. Then, the optimal unknown parameter (i.e., standard deviation) of the predictive distribution is estimated by a support vector regression surrogate model based on the deterministic forecasts. Lastly, probabilistic forecasts are generated from the predictive distribution. Numerical results of case studies at eight locations show that the developed two-step probabilistic forecasting methodology has improved the pinball loss metric score by up to 35% compared to a baseline quantile regression forecasting model.

17 WIND ENERGY↗

Extrapolating W -associated jet-production ratios at the LHC

Electroweak vector-boson production, accompanied by multiple jets, is an important background to searches for physics beyond the standard model. A precise and quantitative understanding of this process is helpful in constraining deviations from known physics. We study four key ratios in W + n -jet production at the LHC. We compute the ratio of cross sections for W + n - to W + (n-1)-jet production as a function of the minimum jet transverse momentum. We also study the ratio differentially, as a function of the W-boson transverse momentum; as a function of the scalar sum of the jet transverse energy, H$jets\atop{T}$; and as a function of certain jet transverse momenta. We show how to use such ratios to extrapolate differential cross sections to W + 6 -jet production at next-to-leading order, and we cross-check the method against a direct calculation at leading order. We predict the differential distribution in H$jets\atop{T}$ for W + 6 jets at next-to-leading order using such an extrapolation. We use the BlackHat software library together with SHERPA to perform the computations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Equivalence Principle and Gravitational Redshift

We investigate leading order deviations from general relativity that violate the Einstein equivalence principle in the gravitational standard model extension. We show that redshift experiments based on matter waves and clock comparisons are equivalent to one another. Consideration of torsion balance tests, along with matter-wave, microwave, optical, and Moessbauer clock tests, yields comprehensive limits on spin-independent Einstein equivalence principle-violating standard model extension terms at the 10{sup -6} level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evidence for Exotic Hadron Contributions to Λ b 0 → J / ψ p π – Decays

A full amplitude analysis of Λ 0 b →J/ψpπ – decays is performed with a data sample acquired with the LHCb detector from 7 and 8 TeV pp collisions, corresponding to an integrated luminosity of 3 fb –1 . A significantly better description of the data is achieved when, in addition to the previously observed nucleon excitations N→pπ – , either the P c (4380) + and P c (4450) + →J/ψp states, previously observed in Λ 0 b →J/ψpK – decays, or the Z c (4200) – →J/ψπ – state, previously reported in B 0 →J/ψK + π – decays, or all three, are included in the amplitude models. The data support a model containing all three exotic states, with a significance of more than three standard deviations. Within uncertainties, the data are consistent with the P c (4380) + and P c (4450) + production rates expected from their previous observation taking account of Cabibbo suppression.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of the $γγ → ττ$ Process in $\mathrm{Pb + Pb}$ Collisions and Constraints on the $\tau$-Lepton Anomalous Magnetic Moment with the ATLAS Detector

This Letter reports the observation of τ-lepton pair production in ultraperipheral lead-lead collisions, Pb+Pb→Pb(γγ→ττ)Pb, and constraints on the τ-lepton anomalous magnetic moment, a τ . The dataset corresponds to an integrated luminosity of 1.44 nb -1 of LHC Pb+Pb collisions at $\sqrt{s_{NN}}$ =5.02 TeV recorded by the ATLAS experiment in 2018. Selected events contain one muon from a τ-lepton decay, an electron or charged-particle track(s) from the other τ-lepton decay, little additional central-detector activity, and no forward neutrons. The γγ→ττ process is observed in Pb+Pb collisions with a significance exceeding 5 standard deviations, and a signal strength of μ ττ =1.03$^{+0.06}_{-0.05}$ assuming the Standard Model value for a τ . To measure a τ , a template fit to the muon transverse-momentum distribution from τ-lepton candidates is performed, using a dimuon (γγ→μμ) control sample to constrain systematic uncertainties. The observed 95% confidence-level interval for aτ is -0.057 < a τ < 0.024.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-39: A Logistic Function-Based Model to Predict Organ-At-Risk (OAR) DVH in IMRT Treatment Planning

Purpose: To investigate the feasibility of a logistic function-based model to predict organ-at-risk (OAR) DVH for IMRT planning. The predicted DVHs are compared to achieved DVHs by expert treatment planners. Methods: A logistic function is used to model the OAR dose-gradient function. This function describes the percentage of the prescription dose as a function of the normal distance to PTV surface. The slope of dose-gradient function is function of relative spatial orientation of the PTV and OARs. The OAR DVH is calculated using the OAR dose-gradient function assuming that the dose is same for voxels with same normal distance to PTV. Ten previously planned prostate IMRT plans were selected to build the model, and the following plan parameters were calculated as possible features to the model: the PTV maximum/minimum dose, PTV volume, bladder/rectum volume in the radiation field, percentage of bladder/rectum overlapping with PTV, and the distance between the bladder/rectum centroid and PTV. The bladder/rectum dose-gradient function was modeled and applied on 10 additional test cases, and the predicted and achieved clinical bladder/rectum DVHs were compared: V70 (percentage of volume receiving 70Gy and above), V65, V60, V55, V50, V45, V40. Results: The following parameters were selected as model features: PTV volume, and distance of centroid of rectum/bladder to PTV. The model was tested with 10 additional patients. For bladder, the absolute difference (mean±standard deviation) between predicted and clinical DVHs is V70=−0.3±3.2, V65=−0.8±3.9, V60=1.5±4.3, V55=1.7±5.3, V50=−0.6±6.4, V45=0.6±6.5, and V40=0.9±5.7, the correlation coefficient is 0.96; for rectum, the difference is V70=1.5±3.8, V65=1.2±4.2, V60=−0.1±5.3, V55=1.0±6.6, V50=1.6±8.7, V45=1.9±9.8, and V40=1.5±10.1, and the correlation coefficient is 0.87. Conclusion: The OAR DVH can be accurately predicted using the OAR dose-gradient function in IMRT plans. This approach may be used as a quality control tool and aid less experienced planners determine benchmarks for plan quality.

60 APPLIED LIFE SCIENCES↗

First evidence for WW and WZ diboson production with semi-leptonic decays at a Hadron Collider

Presented is a measurement of the simultaneous production of a W ± boson in association with a second weak boson (W ± or Z 0 ) in p$\bar{p}$ collisions at √s = 1.96 TeV. Events are consider with one electron or one muon, missing transverse energy, and at least two hadronic jets. The data were collected by the D0 detector in Run IIa of the Tevatron accelerator and correspond to 1.07 fb -1 of integrated luminosity for each of the two channels (WW/WZ → evq$\bar{q}$ and WW/WZ → μvq$\bar{q}$). The cross section for WW + WZ production is measured to be 20.2 ± 2.5(stat) ± 3.6(sys) ± 1.2(lum) pb with a Gaussian significance of 4.4 standard deviations above the background-only scenario. This measurement is consistent with the Standard Model prediction and represents the first direct evidence for WW and WZ production with semi-leptonic decays at a hadron collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spitzer IRAC Photometry of JWST Calibration Stars

We present infrared photometry of all 36 potential JWST calibrators for which there is archival Spitzer IRAC data. This photometry can then be used to inform the stellar models necessary to provide absolute calibration for all JWST instruments. We describe in detail the steps necessary to measure IRAC photometry from archive retrieval to photometric corrections. To validate our photometry, we examine the distribution of uncertainties from all detections in all four IRAC channels as well as compare the photometry and its uncertainties to those from models, ALLWISE, and the literature. Seventy-five percent of our detections have standard deviations per star of all observations within each channel of less than 3%. The median standard deviations are 1.2%, 1.3%, 1.1%, and 1.9% in [3.6]–[8.0], respectively. We find less than 8% standard deviations in differences of our photometry with ALLWISE and excellent agreement with literature values (less than 3% difference), lending credence to our measured fluxes. JWST is poised to do groundbreaking science, and accurate calibration and cross-calibration with other missions will be part of the underpinnings of that science.

47 OTHER INSTRUMENTATION↗

Increase in the Amplitude of Line-of-sight Velocities of the Small-scale Motions in a Solar Filament before Eruption

We present a study on the evolution of the small-scale velocity field in a solar filament as it approaches the eruption. The observation was carried out by the Solar Dynamics Doppler Imager (SDDI) that was newly installed on the Solar Magnetic Activity Research Telescope at Hida Observatory. The SDDI obtains a narrowband full-disk image of the Sun at 73 channels from H α − 9.0 Å to H α + 9.0 Å, allowing us to study the line-of-sight (LOS) velocity of the filament before and during the eruption. The observed filament is a quiescent filament that erupted on 2016 November 5. We derived the LOS velocity at each pixel in the filament using the Becker’s cloud model, and made the histograms of the LOS velocity at each time. The standard deviation of the LOS velocity distribution can be regarded as a measure for the amplitude of the small-scale motion in the filament. We found that the standard deviation on the previous day of the eruption was mostly constant around 2–3 km s{sup −1}, and it slightly increased to 3–4 km s{sup −1} on the day of the eruption. It shows a further increase, with a rate of 1.1 m s{sup −2}, about three hours before eruption, and another increase, with a rate of 2.8 m s{sup −2}, about an hour before eruption. From this result we suggest that the increase in the amplitude of the small-scale motions in a filament can be regarded as a precursor of the eruption.

79 ASTRONOMY AND ASTROPHYSICS↗

Higgs boson search in the H->ZZ{sup (*)} decay channels with the CMS detector

A study of the sensitivity for the inclusive production of Standard Model Higgs bosons H decaying in ZZ{sup (*)} pairs is presented with the CMS experiment at the CERN LHC pp collider at 14 TeV centre of mass energy, for the integrated luminosity of 1 fb{sup -1}. The analysis is performed for the leptonic decay channels H->ZZ{sup (*)}->4l with l = e,mu and for a mass m{sub H} in the range from 120 to 250 GeV/c{sup 2}. A simple m{sub H} independent sequence of cuts is established which provides a clean sample of 4l events while preserving the highest signal detection efficiency. A signal with a significance above 2 standard deviations is found unlikely for a Higgs boson with a mass m{sub H} lying anywhere in the mass range considered. In absence of significant deviations from background expectations, upper limits on the production cross-section of a Standard Model-like Higgs boson can be established. The limits extend beyond existing constraints.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Predicting Patient-specific Dosimetric Benefits of Proton Therapy for Skull-base Tumors Using a Geometric Knowledge-based Method

Purpose: To predict the organ at risk (OAR) dose levels achievable with proton beam therapy (PBT), solely based on the geometric arrangement of the target volume in relation to the OARs. A comparison with an alternative therapy yields a prediction of the patient-specific benefits offered by PBT. This could enable physicians at hospitals without proton capabilities to make a better-informed referral decision or aid patient selection in model-based clinical trials. Methods and Materials: Skull-base tumors were chosen to test the method, owing to their geometric complexity and multitude of nearby OARs. By exploiting the correlations between the dose and distance-to-target in existing PBT plans, the models were independently trained for 6 types of OARs: brainstem, cochlea, optic chiasm, optic nerve, parotid gland, and spinal cord. Once trained, the models could estimate the feasible dose–volume histogram and generalized equivalent uniform dose (gEUD) for OAR structures of new patients. The models were trained using 20 patients and validated using an additional 21 patients. Validation was achieved by comparing the predicted gEUD to that of the actual PBT plan. Results: The predicted and planned gEUD were in good agreement. Considering all OARs, the prediction error was +1.4 ± 5.1 Gy (mean ± standard deviation), and Pearson's correlation coefficient was 93%. By comparing with an intensity modulated photon treatment plan, the model could classify whether an OAR structure would experience a gain, with a sensitivity of 93% (95% confidence interval: 87%-97%) and specificity of 63% (95% confidence interval: 38%-84%). Conclusions: We trained and validated models that could quickly and accurately predict the patient-specific benefits of PBT for skull-base tumors. Similar models could be developed for other tumor sites. Such models will be useful when an estimation of the feasible benefits of PBT is desired but the experience and/or resources required for treatment planning are unavailable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the universal late X-ray emission of binary-driven hypernovae and its possible collimation

It has previously been discovered that there is a universal power-law behavior exhibited by the late X-ray emission (LXRE) of a “golden sample” of six long energetic GRBs, when observed in the rest frame of the source. This remarkable feature, independent of the different isotropic energy (E {sub iso}) of each GRB, has been used to estimate the cosmological redshift of some long GRBs. This analysis is extended here to a new class of 161 long GRBs, all with E{sub iso}>10{sup 52} erg. These GRBs are indicated as binary-driven hypernovae (BdHNe) in view of their progenitors: a tight binary system composed of a carbon–oxygen core (CO{sub core}) and a neutron star undergoing an induced gravitational collapse (IGC) to a black hole triggered by the CO{sub core} explosion as a supernova (SN). We confirm the universal behavior of the LXRE for the “enlarged sample” (ES) of 161 BdHNe observed up to the end of 2015, assuming a double-cone emitting region. We obtain a distribution of half-opening angles peaking at θ=17.62{sup ∘}, with a mean value of 30.05{sup ∘}, and a standard deviation of 19.65{sup ∘}. This, in turn, leads to the possible establishment of a new cosmological candle. Within the IGC model, such universal LXRE behavior is only indirectly related to the GRB and originates from the SN ejecta, of a standard constant mass, being shocked by the GRB emission. The fulfillment of the universal relation in the LXRE and its independence of the prompt emission, further confirmed in this article, establishes a crucial test for any viable GRB model.

79 ASTRONOMY AND ASTROPHYSICS↗

Preliminary Modeling, Testing, and Analysis of a Gas Tankless Water Heater: Preprint

Today's gas tankless water heaters offer significant energy savings over conventional gas storage tank water heaters, but savings depends on the draw pattern. A one-node model incorporating heat exchanger mass is used to address this and other issues. Key model parameters are determined from least-squares regression on short-term data, including burner efficiency, thermal capacitance, and thermal loss coefficient. The calibrated model agrees with data to ~5% on Qgas, with temperature RMS deviation of ~4..deg..C. Efficiency with a standard realistic draw is 71%, compared to 81% predicted from standard energy-factors. Adding a small tank controlled by the tankless heater solves issues of oscillations with solar pre-heat, low-flow and hot-water-delay issues. Future work includes model refinements and developing optimal data protocols for model parameter extraction.

14 SOLAR ENERGY↗

Assessment of beating parameters in human induced pluripotent stem cells enables quantitative in vitro screening for cardiotoxicity

Human induced pluripotent stem cell (iPSC)-derived cardiomyocytes show promise for screening during early drug development. Here, we tested a hypothesis that in vitro assessment of multiple cardiomyocyte physiological parameters enables predictive and mechanistically-interpretable evaluation of cardiotoxicity in a high-throughput format. Human iPSC-derived cardiomyocytes were exposed for 30 min or 24 h to 131 drugs, positive (107) and negative (24) for in vivo cardiotoxicity, in up to 6 concentrations (3 nM to 30 uM) in 384-well plates. Fast kinetic imaging was used to monitor changes in cardiomyocyte function using intracellular Ca{sup 2+} flux readouts synchronous with beating, and cell viability. A number of physiological parameters of cardiomyocyte beating, such as beat rate, peak shape (amplitude, width, raise, decay, etc.) and regularity were collected using automated data analysis. Concentration–response profiles were evaluated using logistic modeling to derive a benchmark concentration (BMC) point-of-departure value, based on one standard deviation departure from the estimated baseline in vehicle (0.3% dimethyl sulfoxide)-treated cells. BMC values were used for cardiotoxicity classification and ranking of compounds. Beat rate and several peak shape parameters were found to be good predictors, while cell viability had poor classification accuracy. In addition, we applied the Toxicological Prioritization Index (ToxPi) approach to integrate and display data across many collected parameters, to derive “cardiosafety” ranking of tested compounds. Multi-parameter screening of beating profiles allows for cardiotoxicity risk assessment and identification of specific patterns defining mechanism-specific effects. These data and analysis methods may be used widely for compound screening and early safety evaluation in drug development. - Highlights: • Induced pluripotent stem cell-derived cardiomyocytes are promising in vitro models. • We tested if evaluation of cardiotoxicity is possible in a high-throughput format. • The assay shows benefits of automated data integration across multiple parameters. • Quantitative assessment of concentration–response is possible using iPSCs. • Multi-parametric screening allows for cardiotoxicity risk assessment.

60 APPLIED LIFE SCIENCES↗

SU-E-I-46: Sample-Size Dependence of Model Observers for Estimating Low-Contrast Detection Performance From CT Images

Purpose: Recently, task-based assessment of diagnostic CT systems has attracted much attention. Detection task performance can be estimated using human observers, or mathematical observer models. While most models are well established, considerable bias can be introduced when performance is estimated from a limited number of image samples. Thus, the purpose of this work was to assess the effect of sample size on bias and uncertainty of two channelized Hotelling observers and a template-matching observer. Methods: The image data used for this study consisted of 100 signal-present and 100 signal-absent regions-of-interest, which were extracted from CT slices. The experimental conditions included two signal sizes and five different x-ray beam current settings (mAs). Human observer performance for these images was determined in 2-alternative forced choice experiments. These data were provided by the Mayo clinic in Rochester, MN. Detection performance was estimated from three observer models, including channelized Hotelling observers (CHO) with Gabor or Laguerre-Gauss (LG) channels, and a template-matching observer (TM). Different sample sizes were generated by randomly selecting a subset of image pairs, (N=20,40,60,80). Observer performance was quantified as proportion of correct responses (PC). Bias was quantified as the relative difference of PC for 20 and 80 image pairs. Results: For n=100, all observer models predicted human performance across mAs and signal sizes. Bias was 23% for CHO (Gabor), 7% for CHO (LG), and 3% for TM. The relative standard deviation, σ(PC)/PC at N=20 was highest for the TM observer (11%) and lowest for the CHO (Gabor) observer (5%). Conclusion: In order to make image quality assessment feasible in the clinical practice, a statistically efficient observer model, that can predict performance from few samples, is needed. Our results identified two observer models that may be suited for this task.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗