Search NASA⌕ Search

SEARCH · Search NASA

Results for “Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Active Co-Storage of Cryogenic Propellants for Lunar Explortation

Long-term storage of cryogenic propellants is a critical requirement for NASA's effort to return to the moon. Liquid hydrogen and liquid oxygen provide the highest specific impulse of any practical chemical propulsion system, and thus provides the greatest payload mass per unit of launch mass. Future manned missions will require vehicles with the flexibility to remain in orbit for months, necessitating long-term storage of these cryogenic liquids. For decades cryogenic scientific satellites have used dual cryogens with different temperatures to cool instruments. This technology utilizes a higher temperature cryogen to provide a stage that efficiently intercepts a large fraction of the heat that would otherwise be incident on the lower temperature cryogen. This interception reduces the boil-off of the lower temperature cryogen and increasing the overall life-time of the mission. The Active Co-Storage concept is implemented similarly; the 101 K liquid oxygen thermally shields the 24 K liquid hydrogen. A thermal radiation shield that is linked to the liquid oxygen tank shrouds the liquid hydrogen tank, thereby preventing the liquid hydrogen tank from being directly exposed to the 300 K external environment. Modern cryocooler technology can eliminate the liquid oxygen boil-off and also cool the thermal radiation shield thereby reducing the liquid hydrogen boil-off to a small fraction of the unshielded rate. The thermal radiation shield can be a simple conductive shroud or a more sophisticated but lighter Broad Area Cooling (BAC) shroud. The paper describes the design impact of an active co-storage system for the Altair Descent Vehicle. This paper also compares the spacecraft-level impacts of the conductive shroud and the BAC shroud active co-storage concepts with a passive storage option in the context of the different scales of spacecraft that will be used for the lunar exploration effort - the Altair Ascent and Descent Vehicles, the Orion, and the Ares V Earth Departure Stage. The paper also reports on a subscale test of this active co-storage configuration. The test tank is 0.7 m in diameter, approximately one-third the dimension of tanks that would be needed in a lunar ascent module. A thin-walled fiberglass skirt supports and isolates the tank from a 100 K stage. A similar thin-walled skirt supports the lOOK stage from the ambient temperature structure. An aluminum shield with a heavy MLI blanket surrounds the tank and is attached at the 100 K stage. In this initial phase of the project, there is no tank on the 100 K stage, but it is actively cooled by a single-stage cryocooler similar in design to the one used on the RHESSI mission. The test configuration includes a number of innovative elements, including a helical support heat exchanger and an external thermodynamic vent/heat interception system. To avoid the complexity of an explosive gas handling system, testing will be done with liquid helium and liquid neon as simulant fluids. The properties of these fluids bracket the properties of liquid hydrogen. Instrumentation allows tank temperature and shield temperature profiles, tank liquid levels, and pressure drops through the flow lines, to be measured.

Mustafi, S.↗

Compartmentalized storage tank for electrochemical cell system

A compartmentalized storage tank is disclosed. The compartmentalized storage tank includes a housing, a first fluid storage section disposed within the housing, a second fluid storage section disposed within the housing, the first and second fluid storage sections being separated by a movable divider, and a constant force spring. The constant force spring is disposed between the housing and the movable divider to exert a constant force on the movable divider to cause a pressure P1 in the first fluid storage section to be greater than a pressure P2 in the second fluid storage section, thereby defining a pressure differential.

Piecuch, Benjamin Michael↗

Vent System Analysis for the Cryogenic Propellant Storage Transfer Ground Test Article

To test and validate key capabilities and technologies required for future exploration elements such as large cryogenic propulsion stages and propellant depots, NASA is leading the efforts to develop and design the Cryogenic Propellant Storage and Transfer (CPST) Cryogenic Fluid Management (CFM) payload. The primary objectives of CPST payload are to demonstrate: 1) in-space storage of cryogenic propellants for long duration applications; and 2) in-space transfer of cryogenic propellants. The Ground Test Article (GTA) is a technology development version of the CPST payload. The GTA consists of flight-sized and flight-like storage and transfer tanks, liquid acquisition devices, transfer, and pressurization systems with all of the CPST functionality. The GTA is designed to perform integrated passive and active thermal storage and transfer performance testing with liquid hydrogen (LH2) in a vacuum environment. The GTA storage tank is designed to store liquid hydrogen and the transfer tank is designed to be 5% of the storage tank volume. The LH2 transfer subsystem is designed to transfer propellant from one tank to the other utilizing pressure or a pump. The LH2 vent subsystem is designed to prevent over-pressurization of the storage and transfer tanks. An in-house general-purpose computer program was utilized to model and simulate the vent subsystem operation. The modeling, analysis, and the results will be presented in the final paper.

Hedayat, A↗

Groundwater Storage Changes: Present Status from GRACE Observations

Satellite gravity measurements from the Gravity Recovery and Climate Experiment (GRACE) provide quantitative measurement of terrestrial water storage (TWS) changes with unprecedented accuracy. Combining GRACE-observed TWS changes and independent estimates of water change in soil and snow and surface reservoirs offers a means for estimating groundwater storage change. Since its launch in March 2002, GRACE time-variable gravity data have been successfully used to quantify long-term groundwater storage changes in different regions over the world, including northwest India, the High Plains Aquifer and the Central Valley in the USA, the North China Plain, Middle East, and southern Murray-Darling Basin in Australia, where groundwater storage has been significantly depleted in recent years (or decades). It is difficult to rely on in situ groundwater measurements for accurate quantification of large, regional-scale groundwater storage changes, especially at long timescales due to inadequate spatial and temporal coverage of in situ data and uncertainties in storage coefficients. The now nearly 13 years of GRACE gravity data provide a successful and unique complementary tool for monitoring and measuring groundwater changes on a global and regional basis. Despite the successful applications of GRACE in studying global groundwater storage change, there are still some major challenges limiting the application and interpretation of GRACE data. In this paper, we present an overview of GRACE applications in groundwater studies and discuss if and how the main challenges to using GRACE data can be addressed.

Australia↗

Could Blobs Fuel Storage-Based Convergence between HPC and Big Data?

The increasingly growing data sets processed on HPC platforms raise major challenges for the underlying storage layer. A promising alternative to POSIX-IO- compliant file systems are simpler blobs (binary large objects), or object storage systems. Such systems offer lower overhead and better performance at the cost of largely unused features such as file hierarchies or permissions. Similarly, blobs are increasingly considered for replacing distributed file systems for big data analytics or as a base for storage abstractions such as key-value stores or time-series databases. This growing interest in such object storage on HPC and big data platforms raises the question: Are blobs the right level of abstraction to enable storage-based convergence between HPC and Big Data? In this paper we study the impact of blob-based storage for real-world applications on HPC and cloud environments. The results show that blobbased storage convergence is possible, leading to a significant performance improvement on both platforms

Matri, Pierre↗

Rapid fill compressed gas storage tank

A method for rapidly filling a compressed gas storage tank with a moderated temperature rise using a Coanda nozzle to inject the feed gas into the tank and using the Coanda nozzle to direct the feed gas along the inner surface of the storage tank; entraining the stored gas with the feed gas that is flowing under the influence of the Coanda effect to flow along the inner surface of the gas storage tank; and transferring heat from the flowing gas to the external walls of the tank. Also, a compressed gas storage tank for rapid filling with a moderated temperature rise comprising: a gas storage tank and a Coanda nozzle capable of directing feed gas that is injected into the gas storage tank along the inner surface of the gas storage tank.

Jayaraman, Ambalavanan↗

Carbon Storage Technical Viability Approach and National Data Assessment

Carbon Storage Technical Viability Approach is a comprehensive evaluation of potential geologic carbon storage sites that includes classic subsurface resource assessment components such as reservoir suitability in addition to hazard, environmental, social, regulatory, and jurisdiction components that may enhance or hinder successful carbon storage. Data for assessments of technically viable carbon storage span many categories, types; are disparate and numerous. Variables and types of data required to support CS assessments were previously not clearly defined and documented. Contextualizing available data indicates their utility, potential uncertainty, and gaps. This presentation details the Carbon Storage Technical Viability Approach, the associated matrix and database, and initial results from a portion of the national data availability assessment that contextualizes the data available to support carbon storage projects. Presented at the American Association of Petroleum Geologists' Carbon Capture Utilization and Storage (SPE-AAPG-SEG CCUS 2024) conference in Houston, TX, March 11-13, 2024.

Mark-Moser, Mackenzie K.↗

A simulation study of carbon storage with active reservoir management

As part of the Integrated Midcontinent Stacked Carbon Storage Hub (IMSCS-Hub) project led by Battelle Memorial Institute, a study was conducted to determine the feasibility of storing carbon dioxide (CO 2 ) in the stacked saline rock formations of the Sleepy Hollow Field (SHF), located in Red Willow County, southern Nebraska. A series of CO 2 injection simulation scenarios, with and without active reservoir management (ARM; brine extraction), were evaluated to investigate the feasibility of storing 50+ million tonnes (Mt) of CO 2 . The results indicated CO 2 injection combined with ARM may enable permanent storage of 50+ Mt of CO 2 . The area of review (AOR), the area in which underground sources of drinking water (USDWs) might be endangered during CO 2 injection, was assessed for the simulation scenarios. In comparison to a case without ARM, brine extraction resulted in a much smaller AOR, covering an area of 42 square miles (108.8 km 2 ), roughly one-fourth the size of an AOR resulting from CO 2 injection without ARM. Our findings, presented in this paper, indicate that CO 2 injection with ARM can improve the CO 2 storage capacity of a geologic storage complex up to 100% while also reduce the rate of pressure buildup in the subsurface, resulting in a 75% reduction in AOR. This may help in lowering carbon capture and storage project costs, risks, and effort needed to meet monitoring requirements for a storage project.

54 ENVIRONMENTAL SCIENCES↗

Energy Storage as an Equity Asset

Abstract Purpose of Review This review offers a discussion on how energy storage deployment advances equitable outcomes for the power system. It catalogues the four tenets of the energy justice concept—distributive, recognition, procedural, and restorative—and shows how they relate to inequities in energy affordability, availability, due process, sustainability, and responsibility. Recent Findings Energy storage systems have been deployed to support grid reliability and renewable resource integration, but there is additional emerging value in considering the connections between energy storage applications and equity challenges in the power system. Through a thorough review of the energy justice and energy transitions literature, this paper offers the equity dimensions of storage project design and implementations. Summary Emerging energy programs and projects are utilizing energy storage in pursuit of improved equity outcomes. Future research and policy design should integrate energy justice principles to align storage penetration with desired equity outcomes.

25 ENERGY STORAGE↗

Thermo-hydro-mechanical analysis of subsurface ice-based thermal energy storage

Ice-based thermal energy storage systems are widely utilized for cooling and managing peak electrical demand globally, offering daily or weekly storage capabilities for both individual homes and larger office buildings. However, scaling these systems for district-level cooling or integrating them with renewable energy sources presents challenges, especially in accommodating larger volumes and addressing seasonal storage requirements in densely populated urban areas. This paper proposes a novel solution by evaluating subsurface ice-based thermal energy storage, in which the underground is subjected to seasonal freeze/thaw cycles. However, these cycles may influence ground behavior, affecting pore pressure and inducing ground movement. To systematically investigate these challenges, we enhance the TOUGH-FLAC simulator by integrating water/ice phase change capabilities and updating the effective stress–strain constitutive relation. Both modifications are validated against analytical solutions or experimental data. Through numerical simulations spanning a decade with ten seasonal freeze/thaw cycles, we evaluate the performance and long-term stability of a generic subsurface ice-based thermal energy storage system, considering factors such as ground permeability, freezing pipe spacing, freeze/thaw damage, and glycol solution temperature. The simulations indicate that ice formation induces pore pressure variations that drive seasonal surface heave and settlement, controlled by ground permeability, pipe spacing, and glycol solution temperature, along with tensile and localized shear deformation around freeze pipes. This highlights the need for accurate ground property characterization and geomechanical analysis for subsurface ice-based thermal energy storage.

Ground freezing↗

Comparison of Pt-BaO/Al 2 O 3 and Pt-CeO 2 /Al 2 O 3 for NOx storage and reduction: Impact of cycling frequency

NOx reduction under net lean and near-stoichiometric conditions was carried out on Pt/Al 2 O 3 , Pt/CeO 2 /Al 2 O 3 and Pt/BaO/Al 2 O 3 washcoated monoliths to compare performance features and identify reaction pathways. The impact of the storage components (BaO, CeO 2 ) on the NOx conversion and byproduct (NH 3 and N 2 O) yields was quantified for a range of feed temperatures, reductant types (H 2 , and C 3 H 6 ), O 2 feed concentrations, and cycle times. The NOx storage functionality is essential for NOx reduction under net lean conditions while the oxygen storage functionality promotes NOx reduction for near-stoichiometric conditions. NOx conversion by H 2 under lean conditions is dependent on the NOx storage capacity of the catalyst, with Pt/CeO 2 /Al 2 O 3 and Pt/BaO/Al 2 O 3 exhibiting the highest NOx conversion below and above 300 °C, respectively. High NOx conversion is achieved over Pt/CeO 2 /Al 2 O 3 for anaerobic rich feeds at temperatures above 400 °C. Increasing the O 2 feed concentration enhances NOx conversion over Pt/CeO 2 /Al 2 O 3 below 400 °C but inhibits NOx conversion above 400 °C. The former is attributed to promotion of NO oxidation leading to NOx storage while the latter is attributed to O 2 inhibition of NO decomposition/reduction. Shorter cycle times increase the NOx conversion with C 3 H 6 as reductant over Pt/BaO/Al 2 O 3 under lean conditions and over PCA for the near-stoichiometric feed. The findings confirm that improved NOx storage utilization is mainly responsible for NOx conversion enhancement. A ceria redox pathway has only a secondary effect on NOx conversion under excess O 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical modeling study of a man-made low-permeability barrier for the compressed air energy storage in high-permeability aquifers

Compressed air energy storage (CAES) is a grid-scale energy storage technology for intermittent energy, as proven by the decades-long successful operation of two existing compressed air energy storage in cavern (CAESC) power plants. Because of the limited availability of salt domes appropriate for CAESC, the more widely available aquifers (compressed air energy storage in aquifers, CAESA) have recently attracted considerable attention as candidates for CAES. An ideal aquifer for CAESA is highly permeable around the well to facilitate easy injection and withdrawal of air, but the high-permeability region is surrounded by low-permeability zones to minimize the loss of injected air and decrease in energy efficiency. However, such ideal geological structures are not always available in nature. Therefore, the potential of creating man-made low-permeability barrier in high-permeability aquifers is very interesting. In this paper, we investigate the feasibility of man-made low-permeability barriers in high-permeability aquifers using the numerical simulator TOUGH2/Gel to calculate the three-component flow (including a miscible gelling liquid). The simulation results show that an expected low-permeability barrier can be created by injecting grout with certain properties, and the altered aquifer performs well for CAESA. Additional sensitivity studies are also performed to reveal the effects of the various factors on the success of the low-permeability barrier creation, including the critical solidification concentration, the scale factor of the time dependence of the grout viscosity, the relative density of the grout, and the volume of the follow-up water injection. The results indicate that, in a horizontal aquifer, low critical solidification concentrations, and small scale factors are generally preferred and the density of grout should be close to that of the in situ water. For the given volume of the injected grout, there is an optimal follow-up water injection that will create the largest storage space without damaging the barrier. Furthermore, these results may help to extend the candidate sites for CAESA and the prospect of large scale energy storage.

25 ENERGY STORAGE↗

A Market Feedback Framework for Improved Estimates of the Arbitrage Value of Energy Storage Using Price-Taker Models

Price-taker (PT) models are often used to assess the potential value or revenue of energy arbitrage opportunities for energy storage in wholesale markets. But as greater amounts of energy storage are deployed on the grid, current PT models fail to predict the effects that energy storage itself can have on market prices. This can lead to an overestimation of the economic value of storage and an inability to capture price suppression. In this paper, we propose the use of a modified PT model to simulate the impact of increased storage deployment on energy prices and the resulting impact on revenue. Our method uses a gradient-boosting regressor to estimate the impact on prices, and we apply our method on historical price data from the PJM and California Independent System Operator wholesale markets. We use this approach to explore possible causes of electricity price suppression that occur from storage capacity additions, which is generally not possible with PT models.

arbitrage↗

Cost analysis of distributed storage in AC and DC microgrids

Building and microgrid designs with highly-distributed electrical storage have potential advantages over today's conventional topologies with centralized storage. Herein this paper studies the capital cost benefits of several residential behind-the-meter distributed-storage topologies, including AC and DC versions of systems with load-packaged batteries and resilient sub-networks. The study begins by defining the block configuration of each topology. This work then develops a model for the cost of the power electronics necessary to interface with the storage elements. Finally, the analysis develops a model for the total cost of each storage topology, incorporating the installation and soft costs. The results suggest that while the cost of power electronics is lower in centralized topologies, the total cost is lower for distributed storage due to the avoided costs of installation and permitting. This paper also explores the benefits of load-packaged batteries for savings in electrical infrastructure.

25 ENERGY STORAGE↗

Synergies and trade-offs between storage, transmission, and sector coupling in high renewable energy systems

Energy storage, transmission, and sector coupling are some prominent flexibility solutions to support variable renewable energy (VRE) integration. However, investment cost uncertainties and public acceptance could hamper the deployment of these flexibility solutions. This raises questions about the development and cost-effectiveness of future energy systems, especially on how the dependence on local and cross-border solutions of flexibility would evolve if the uptake of these solutions is restricted. In this context, this paper identifies the synergies among flexibility options under restrictions on transmission expansion or increased costs of energy storage. It contributes to determining whether investments in energy storage and/or transmission expansion offer the least-cost transition and investigates the impact of sector coupling on these solutions. A long-term energy system planning and optimisation model towards 2050 is developed using the open-source energy system optimisation tool Balmorel, and a case study of the countries surrounding the Baltic Sea and the North Sea is established. Five cases with restrictions imposed on transmission expansion and higher energy storage technology costs are analysed at different levels of sector coupling. The results highlight the importance of transmission expansion at all levels of sector coupling. As the level of sector coupling increases, uncertainties around the cost of energy storage drive the least-cost pathways. Optimal investment solutions are found to have a mix of transmission and energy storage in capacity expansion at all levels of sector coupling.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nanoengineering of 2D MBenes for energy storage applications: A review

2D transition metal borides (MBenes), a flourishing member of the 2D nanomaterial family, show great potential in a number of study areas. MBenes have received increasing attention thanks to their excellent electrical conductivity, structural and mechanical properties, and chemical stability, which have captivated researchers and sparked further exploration. Extensive theoretical and experimental investigations have unveiled its remarkable potential as electrode materials for electrochemical storage applications, making MBenes a subject of great interest. Despite the growing interest and numerous studies conducted, there is a lack of a comprehensive and systematic appraisal of MBenes' applications in electrochemical energy storage systems. Here, in light of this, firstly, we provide an overview of the current progress in the fabrication and characterization of MAB phases and MBenes. For the synthesis of MBenes, the following fabrication techniques were discussed; liquid-phase exfoliation, solid-state mechanical exfoliation, chemical vapor deposition, high-pressure chemical vapor deposition, microwave-assisted chemical etching, and ultrasound-assisted chemical etching methods. Then, we delve into the captivating potential of MBenes, specifically in the realm of energy storage applications and their role in enhancing electrochemical storage capabilities. The discussion encompasses their application in lithium-ion, lithium-sulfur, and lithium-selenide batteries, supercapacitors and other energy storage systems, providing a comprehensive perspective on their contributions to the energy landscape. Finally, a brief but significant summary of the challenges and opportunities of MBenes in practical applications was summarized. The present review provides a guide and scientific motivation for creating and developing advanced MBene-based nanomaterials, addressing the growing demand for cutting-edge energy storage systems.

25 ENERGY STORAGE↗

Energy storage planning for enhanced resilience of power systems against wildfires and heatwaves

Extreme weather events pose significant risks to power grid stability due to their severe consequences and potential for widespread failures. Energy storage systems hold great potential for enhancing grid resilience against such events by providing reliable power during peak demand periods. However, accurately quantifying the size, location, and investment costs of new energy storage assets is a complex task, as energy storage planning decisions depend on the investment choices of other generation technologies and the integration of new transmission projects. Here, this paper presents a novel capacity expansion planning framework that simultaneously optimizes investments in energy storage, generation, and transmission, determining their optimal size, location, and type, while incorporating extreme weather events into long-term planning. More specifically, our stress-event-informed planning framework integrates the impact of heatwaves and wildfires into the planning process, identifying least-cost investment solutions that comply with policy goals and enhance grid resilience. The proposed framework employs machine-learning-based modeling to project heatwave-induced loads and performance-based risk assessment to evaluate wildfire-driven transmission line derates. Using industry-standard datasets to accurately represent the transmission topology of the Western Interconnection (WI) system, the proposed framework is applied to the WI 40-zone system, with investment decisions reported for the years 2030, 2035, and 2040. Simulation results reveal that with just a 10% increase in investment costs, resilience against extreme events can be significantly improved, with investment decisions heavily favoring energy storage, particularly 4-hour energy storage systems.

25 ENERGY STORAGE↗

Modeling of a thermal energy storage system based on coupled metal hydrides (magnesium iron – sodium alanate) for concentrating solar power plants

Concentrating solar power plants represent low cost and efficient solutions for renewable electricity production only if adequate thermal energy storage systems are included. Metal hydride thermal energy storage systems have demonstrated the potential to achieve very high volumetric energy densities, high exergetic efficiencies, and low costs. The current work analyzes the technical feasibility and the performance of a storage system based on the high temperature Mg 2 FeH 6 hydride coupled with the low temperature Na 3 AlH 6 hydride. To accomplish this, a detailed transport model has been set up and the coupled metal hydride system has been simulated based on a laboratory scale experimental configuration. Proper kinetics expressions have been developed and included in the model to replicate the absorption and desorption process in the high temperature and low temperature hydride materials. The system showed adequate hydrogen transfer between the two metal hydrides, with almost complete charging and discharging, during both thermal energy storage and thermal energy release. The system operating temperatures varied from 450°C to 500°C, with hydrogen pressures between 30 bar and 70 bar. This makes the thermal energy storage system a suitable candidate for pairing with a solar driven steam power plant. The model results, obtained for the selected experimental configuration, showed an actual thermal energy storage system volumetric energy density of about 132 kWh/m 3 , which is more than 5 times the U.S. Department of Energy SunShot target (25 kWh/m 3 ).

14 SOLAR ENERGY↗