Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEST PROTOCOL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Trimethyloxonium-mediated methylation strategies for the rapid and simultaneous analysis of chlorinated phenols in various soils by electron impact gas chromatography–mass spectrometry

Abstract The efficient methylation of a panel of five industrial and environmentally-relevant chlorophenols (CPs) employing trimethyloxonium tetrafluoroborate (TMO) for their qualitative detection and identification by electron impact gas chromatography–mass spectrometry (EI-GC–MS) is presented. The protocol’s execution is simple and smoothly converts the phenols into their O-methylated counterparts conveniently at ambient temperature. The efficiency of two versions of the protocol was successfully tested in their ability to simultaneously derivatize five CPs (2-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol, pentachlorophenol and triclosan) in six distinct, separate soil matrices (Nebraska EPA standard soil, Virginia Type A soil, Ottawa sand, Baker sand, Silt and Georgia EPA standard soil) when present at low levels (~ 10 μgg −1 ). The first version involves the direct derivatization of the spiked soils with the methylating salt while the second one involves an initial soil extraction step of the CPs followed by methylation. The MDL values for each methylated CP were determined and lower values were found (4.1–13.2 ng . mL −1 ) for both sand matrices (Ottawa and Baker) as well as for the Georgia EPA standard soil, while larger values (8.2–21.8 ng . mL −1 ) were found for the Virginia Type soil, Nebraska EPA standard soil and Silt. The presented protocol offers a safer and more practical alternative to the universally employed diazomethane method and can be readily applicable to matrices other than soils. Furthermore, the protocols described herein may find applicability to the methylation of other analytes bearing acidic protons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photosynthetic pigment concentrations, gas exchange and vegetative growth for selected monocots and dicots treated with two contrasting coal fly ashes

There is uncertainty as to the rates of coal fly ash needed for optimum physiological processes and growth. In the current study we tested the hyothesis that photosynthetic pigments concentrations and CO{sub 2} assimilation (A) are more sensitive than dry weights in plants grown on media amended with coal fly ash. We applied the Terrestrial Plant Growth Test (Guideline 208) protocols of the Organization for Economic Cooperation and Development (OECD) to monocots (barley (Hordeum vulgare) and ryegrass (Secale cereale)) and dicots (canola (Brasica napus), radish (Raphanus sativus), field peas (Pisum sativum), and lucerne (Medicago sativa)) on media amended with fly ashes derived from semi-bituminous (gray ash) or lignite (red ash) coals at rates of 0, 2.5, 5.0, 10, or 20 Mg ha(-1). The red ash had higher elemental concentrations and salinity than the gray ash. Fly ash addition had no significant effect on germination by any of the six species. At moderate rates ({<=}10 Mg ha{sup -1}) both ashes increased (P < 0.05) growth rates and concentrations of chlorophylls a and b, but reduced carotenoid concentrations. Addition of either ash increased A in radish and transpiration in barley. Growth rates and final dry weights were reduced for all of the six test species when addition rates exceeded 10 Mg ha{sup -1} for gray ash and 5 Mg ha{sup -1} for red ash. We concluded that plant dry weights, rather than pigment concentrations and/or instantaneous rates of photosynthesis, are more consistent for assessing subsequent growth in plants supplied with fly ash.

01 COAL, LIGNITE, AND PEAT↗

Innovative Strategy For Long Term Monitoring Of Metal And Radionuclide Plumes

Many government and private industry sites that were once contaminated with radioactive and chemical wastes cannot be cleaned up enough to permit unrestricted human access. The sites will require long term management, in some cases indefinitely, leaving site owners with the challenge of protecting human health and environmental quality at these "legacy" sites. Long-term monitoring of groundwater contamination is one of the largest projected costs in the life cycle of environmental management at the Savannah River Site, the larger DOE complex, and many large federal and private sites. There is a need to optimize the performance and manage the cost of long term surveillance and monitoring at their sites. Currently, SRNL is initiating a pilot field test using alternative protocols for long term monitoring of metals and radionuclides. A key component of the approach is that monitoring efforts are focused on measurement of low cost metrics related to hydrologic and chemical conditions that control contaminant migration. The strategy combines careful monitoring of hydrologic boundary conditions with measurement of master variables such as chemical surrogates along with a smaller number of standard well analyses. In plumes contaminated with metals, master variables control the chemistry of the groundwater system, and include redox variables (ORP, DO, chemicals), pH, specific conductivity, biological community (breakdown/decay products), and temperature. Significant changes in these variables will result in conditions whereby the plume may not be stable and therefore can be used to predict possible plume migration. Conversely, concentration measurements for all types of contaminants in groundwater are a lagging indicator plume movement - major changes contaminant concentrations indicate that contamination has migrated. An approach based on measurement of master variables and explicit monitoring of hydrologic boundary conditions combined with traditional metrics should lead to improved monitoring while simultaneously reducing costs. This paradigm is being tested at the SRS F-Area where an innovative passive remedial system is being monitored and evaluated over the long term prior to traditional regulatory closure. Contaminants being addressed at this site are uranium, strontium-90, iodine-129, and tritium. We believe that the proposed strategies will be more effective in early identification of potential risks; these strategies will also be cost effective because controlling variables are relatively simple to measure. These variables also directly reflect the evolution of the plume through time, so that the monitoring strategy can be modified as the plume 'ages'. This transformational long-term monitoring paradigm will generate large cost savings to DOE, other federal agencies and industry and will provide improved performance and leading indicators of environmental management performance.

54 ENVIRONMENTAL SCIENCES↗

Development and field testing of a rapid and ultra-stable atmospheric carbon dioxide spectrometer

We present field test results for a new spectroscopic instrument to measure atmospheric carbon dioxide (CO 2 ) with high precision (0.02 μmol mol -1 , or ppm at 1 Hz) and demonstrate high stability (within 0.1 ppm over more than 8 months), without the need for hourly, daily, or even monthly calibration against high-pressure gas cylinders. The technical novelty of this instrument (ABsolute Carbon dioxide, ABC) is the spectral null method using an internal quartz reference cell with known CO 2 column density. Compared to a previously described prototype, the field instrument has better stability and benefits from more precise thermal control of the optics and more accurate pressure measurements in the sample cell (at the mTorr level). The instrument has been deployed at a long-term ecological research site (the Harvard Forest, USA), where it has measured for 8 months without on-site calibration and with minimal maintenance, showing drift bounds of less than 0.1 ppm. Field measurements agree well with those of a commercially available cavity ring-down CO 2 instrument (Picarro G2301) run with a standard calibration protocol. This field test demonstrates that ABC is capable of performing high-accuracy, unattended, continuous field measurements with minimal use of reference gas cylinders.

Xiang, B.↗

SU-E-QI-06: Design and Initial Validation of a Precise Capillary Phantom to Test Perfusion Systems

Purpose: To design a precise perfusion phantom mimicking capillaries of the brain vasculature which could be used to test various perfusion protocols and algorithms which generate perfusion maps. Methods: A perfusion phantom was designed in Solidworks and built using additive manufacturing. The phantom was an overall cylindrical shape of diameter and height 20mm and containing capillaries of 200μm or 300μm which were parallel and in contact making up the inside volume where flow was allowed. We created a flow loop using a peristaltic pump and contrast agent was injected manually. Digital Subtraction Angiographic images and low contrast images with cone beam CT were acquired after the contrast was injected. These images were analyzed by our own code in LabVIEW software and Time-Density Curve, MTT and TTP was calculated. Results: Perfused area was visible in the cone beam CT images; however, individual capillaries were not distinguishable. The Time-Density Curve acquired was accurate, sensitive and repeatable. The parameters MTT, and TTP offered by the phantom were very sensitive to slight changes in the TDC shape. Conclusion: We have created a robust calibrating model for evaluation of existing perfusion data analysis systems. This approach is extremely sensitive to changes in the flow due to the high temporal resolution and could be used as a golden standard to assist developers in calibrating and testing of imaging perfusion systems and software algorithms. Supported by NIH Grant: 2R01EB002873 and an equipment grant from Toshiba Medical Systems Corporation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Current Density Durability of Pt/C and PtCo/C Catalysts at Similar Particle Sizes in PEMFCs

The durability of carbon supported PtCo-alloy based nanoparticle catalysts play a key role in the longevity of proton-exchange membrane fuel cells (PEMFC) in electric vehicle applications. To improve its durability, it is important to understand and mitigate the various factors that cause PtCo-based cathode catalyst layers (CCL) to lose performance over time. These factors include i) electrochemical surface area (ECSA) loss, ii) specific activity loss, iii) H + /O 2 -transport changes and iv) Co 2+ contamination effects. We use a catalyst-specific accelerated stress test (AST) voltage cycling protocol to compare the durability of Pt and PtCo catalysts at similar average nanoparticle size and distribution. Our studies indicate that while Pt and PtCo nanoparticle catalysts suffer from similar magnitudes of electrochemical surface area (ECSA) losses, PtCo catalyst shows a significantly larger cell voltage loss at high current densities upon durability testing. The distinctive factor causing the large cell voltage loss of PtCo catalyst appears to be the secondary effects of the leached Co 2+ cations that contaminate the electrode ionomer. A 1D performance model has been used to quantify the cell voltage losses arising from various factors causing degradation of the membrane electrode assembly (MEA).

08 HYDROGEN↗

Nasa Exploration Atmosphere Tests 3 & 4: Development and Validation of Planetary Extravehicular Activity Prebreathe Protocols for Alternate Atmospheres and Suit Pressures

INTRODUCTION: Space suits operate at low pressures to optimize astronauts’ performance. The drop in pressure from the habitat environment to the suit carries a risk of decompression sickness (DCS), which is mitigated by a 95% O2 prebreathe protocol. Prebreathe protocols for the lunar surface have a significantly higher risk compared to International Space Station microgravity Extravehicular Activities (EVA). In previous studies, we validated a prebreathe protocol from a 56.5 kPa 34% O2 cabin to a 29.6 kPa EVA pressure; however, the enriched oxygen cabin environment poses a flammability risk that requires significant changes to material design and selections. Here, we report outcomes for prebreathe protocols from a sub-30% O2 cabin and associated changes necessary to control DCS risk critical to upcoming lunar missions. METHODS: Fourteen volunteers completed 11-day hypobaric chamber studies with an “alternate exploration atmosphere” of 66.2kPa, 28.5% O2. Subjects acclimated for 48 hrs and then participated in five 6-hour simulated EVAs at 29.6 or 35.6kPa, 95% O2. Prior to EVA, subjects underwent a 20, 90, or 150-minute prebreathe. The EVA simulation was designed to be representative of future planetary EVAs, proportionate to the subject’s VO2max. Decompression stress was monitored by real-time doppler and echocardiograph alternating every 15 min, as well as clinical monitoring for DCS signs/symptoms. Venous gas emboli (VGE) and DCS outcomes were verified against NASA-STD-3001 acceptance criteria. RESULTS AND DISCUSSION: Venous gas emboli (VGE) were identified during all EVAs. A neurological DCS case was identified in the 90-min/29.6kPa prebreathe, terminating further testing of this protocol. No DCS cases were identified in the 150 min/29.6kPa protocol. The 20 min/36.5kPa protocol was rejected due to a Type II DCS case. All DCS symptoms resolved with treatment, with no sequelae post initial treatment of DCS. These various test points highlighted to the significant benefit of elevated suit pressure to shorten prebreathe protocols, but also the difficulty in assessing and managing DCS during sustained EVA operations in remote planetary surfaces.

decompression sickness↗

Exploratory analysis and performance prediction of big data transfer in High-performance Networks

Big data transfer in large-scale scientific and business applications is increasingly carried out over connections with guaranteed bandwidth provisioned in High-performance Networks (HPNs) via advance bandwidth reservation. Provisioning agents need to carefully schedule data transfer requests, compute network paths, and allocate appropriate bandwidths. Such reserved bandwidths, if not fully utilized, could be simply wasted due to the exclusive access during the approved time window, and cause extra overhead and complexity for resource management. This calls for accurate performance prediction to reserve bandwidths that match actual needs and avoid over-provisioning. We employ machine learning algorithms to predict big data transfer performance based on extensive performance measurements collected in the past several years from data transfer tests using different protocols and toolkits between various end sites on several real-life physical or emulated testbeds. We first analyze the performance patterns in response to a comprehensive list of parameters in end-host systems, network connections, and data transfer applications, which motivate the use of machine learning and also help us identify the effects of latent factors. We then propose threshold- and clustering-based methods to eliminate negative effects of latent factors in data preprocessing and build a robust performance predictor based on customized domain-oriented loss functions. The performance of the proposed methods is verified by extensive experiments using SVR and RFR as well as theoretical analysis of the general performance bound.

97 MATHEMATICS AND COMPUTING↗

Radiosensitivity Differences Between Liver Metastases Based on Primary Histology Suggest Implications for Clinical Outcomes After Stereotactic Body Radiation Therapy

Purpose/Objectives: Evidence from the management of oligometastases with stereotactic body radiation therapy (SBRT) reveals differences in outcomes based on primary histology. We have previously identified a multigene expression index for tumor radiosensitivity (RSI) with validation in multiple independent cohorts. In this study, we assessed RSI in liver metastases and assessed our clinical outcomes after SBRT based on primary histology. Methods and Materials: Patients were identified from our prospective, observational protocol. The previously tested RSI 10 gene assay was run on samples and calculated using the published algorithm. An independent cohort of 33 patients with 38 liver metastases treated with SBRT was used for clinical correlation. Results: A total of 372 unique metastatic liver lesions were identified for inclusion from our prospective, institutional metadata pool. The most common primary histologies for liver metastases were colorectal adenocarcinoma (n=314, 84.4%), breast adenocarcinoma (n=12, 3.2%), and pancreas neuroendocrine (n=11, 3%). There were significant differences in RSI of liver metastases based on histology. The median RSIs for liver metastases in descending order of radioresistance were gastrointestinal stromal tumor (0.57), melanoma (0.53), colorectal neuroendocrine (0.46), pancreas neuroendocrine (0.44), colorectal adenocarcinoma (0.43), breast adenocarcinoma (0.35), lung adenocarcinoma (0.31), pancreas adenocarcinoma (0.27), anal squamous cell cancer (0.22), and small intestine neuroendocrine (0.21) (P<.0001). The 12-month and 24-month Kaplan-Meier rates of local control (LC) for colorectal lesions from the independent clinical cohort were 79% and 59%, compared with 100% for noncolorectal lesions (P=.019), respectively. Conclusions: In this analysis, we found significant differences based on primary histology. This study suggests that primary histology may be an important factor to consider in SBRT radiation dose selection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Kinetic modelling of anaerobic hydrolysis of solid wastes, including disintegration processes

Highlights: • Fractionation of solid wastes into readily and slowly biodegradable fractions. • Kinetic coefficients estimation from mono-digestion batch assays. • Validation of kinetic coefficients with a co-digestion continuous experiment. • Simulation of batch and continuous experiments with an ADM1-based model. - Abstract: A methodology to estimate disintegration and hydrolysis kinetic parameters of solid wastes and validate an ADM1-based anaerobic co-digestion model is presented. Kinetic parameters of the model were calibrated from batch reactor experiments treating individually fruit and vegetable wastes (among other residues) following a new protocol for batch tests. In addition, decoupled disintegration kinetics for readily and slowly biodegradable fractions of solid wastes was considered. Calibrated parameters from batch assays of individual substrates were used to validate the model for a semi-continuous co-digestion operation treating simultaneously 5 fruit and vegetable wastes. The semi-continuous experiment was carried out in a lab-scale CSTR reactor for 15 weeks at organic loading rate ranging between 2.0 and 4.7 g VS/L d. The model (built in Matlab/Simulink) fit to a large extent the experimental results in both batch and semi-continuous mode and served as a powerful tool to simulate the digestion or co-digestion of solid wastes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Quest for Functional Oxide Cathodes for Magnesium Batteries: A Critical Perspective

The Mg battery is an energy storage technology which has garnered significant interest in recent years. Mg batteries incorporating a metal oxide cathode (MOC) are potential candidates to supersede the state-of-the-art Li-ion battery in energy density, cost, and sustainability. However, there are significant discrepancies in reported performances and reactivities of Mg battery MOCs, with detailed analyses revealing that parasitic electrolyte reactions can contribute almost entirely to the measured capacity. This Perspective describes a holistic approach. encompassing elemental, redox, and structural probes-which is vital to robustly confirm and quantify Mg intercalation in MOCs. It critically surveys recent literature for applications of this approach to reveal true state-of-the-art MOCs for Mg batteries. We also suggest testing and analysis protocols to ensure fair comparison of future reports with these state-of-the-art materials.

25 ENERGY STORAGE↗

3D Porous Graphitic Nanocarbon for Enhancing Performance and Durability of Pt Catalysts: Balance between Graphitization and Hierarchical Porosity

Carbon supports used in oxygen-reduction cathode catalysts for proton exchange membrane fuel cells (PEMFCs) are vulnerable to corrosion under harsh operating conditions, leading to poor performance durability. To address this issue, we have developed a highly stable porous graphitic carbon (PGC) produced through pyrolysis of a 3D polymer hydrogel in combination with Mn. The resulting PGC features multilayer carbon sheets assembled in porous and flower-like morphologies. In-situ high-temperature electron microscopy was employed to dynamically monitor the carbonization process up to 1100°C, suggesting that 3D polymer hydrogel provides high porosity at multiple scales, and that Mn catalyzes the graphitization process more effectively than other metals. Compared to conventional carbons such as Vulcan, Ketjenblack, and graphitized carbon, the PGC provides an improved balance between high graphitization and hierachical porosity, which is favorable for uniform Pt nanoparticle dispersion and enhanced corrosion resistance. As a result, Pt supported on PGC exhibits remarkably enhanced stability. In addition to thorough testing in aqueous electrolytes, we also conducted fuel cell testing using durability protocols recommended by the U.S. Department of Energy (DOE). After 5000 voltage cycles from 1.0 to 1.5 V, the Pt/PGC catalyst only lost 9 mV at a current density of 1.5 A/cm 2 , dramatically exceeding the DOE support durability target (<30 mV), and surpassing commercial Pt/C catalysts. Along with the enhanced carbon corrosion resistance of the PGC support, the enhanced catalyst-support interactions are beneficial for stability improvement, likely due to nitrogen doping into carbon, which was further elucidated through X-ray absorption spectroscopy and density functional theory (DFT) calculations. Thus, the high stability and activity of PGC-based Pt catalysts are attributed to the combination of high graphitization degree, favorable surface areas and porosity, and nitrogen doping, which effectively stabilize highly dispersed Pt nanoparticles.

25 ENERGY STORAGE↗

Analysis of humidity sensitivity of silicon strip sensors for ATLAS upgrade tracker, pre- and post-irradiation

During the prototyping phase of the new ATLAS Inner-Tracker (ITk) strip sensors, a degradation of the device breakdown voltage at high humidity was observed. Although the degradation was temporary, showing a fast recovery in dry conditions, the study of the influence of humidity on the sensor performance was critical to establish counter-measures and handling protocols during production testing in order to ensure the proper performance of the upgraded detector. The work presented here has the objective to study for the first time the breakdown voltage deterioration in presence of ambient humidity of ATLAS ITk production-layout strip sensors with different surface properties, before and after proton, neutron and gamma irradiations. A study of the humidity sensitivity of miniature ATLAS ITk strip sensors, before and after proton irradiations, is also presented to compare the sensitivity of devices with different sizes. The sensors were also exposed for several days to high humidity with the aim to recreate and evaluate the influence of the detector integration environment expected during the Large Hadron Collider (LHC) Long Shutdown 3 (LS3) in 2026, where the sensors will be exposed to ambient humidity for prolonged times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bell-inequality tests with macroscopic entangled states of light

Quantum correlations may violate the Bell inequalities. Most experimental schemes confirming this prediction have been realized in all-optical Bell tests suffering from the detection loophole. Experiments which simultaneously close this loophole and the locality loophole are highly desirable and remain challenging. An approach to loophole-free Bell tests is based on amplification of the entangled photons (i.e., on macroscopic entanglement), for which an optical signal should be easy to detect. However, the macroscopic states are partially indistinguishable by classical detectors. An interesting idea to overcome these limitations is to replace the postselection by an appropriate preselection immediately after the amplification. This is in the spirit of state preprocessing revealing hidden nonlocality. Here, we examine one of the possible preselections, but the presented tools can be used for analysis of other schemes. Filtering methods making the macroscopic entanglement useful for Bell tests and quantum protocols are the subject of an intensive study in the field nowadays.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Software-defined Quantum Communication Systems

Quantum communication systems harness modern physics through state-of-the-art optical engineering to provide revolutionary capabilities. An important concern for quantum communication engineering is designing and prototyping these systems to prototype proposed capabilities. We apply the paradigm of software-defined communica- tion for engineering quantum communication systems to facilitate rapid prototyping and prototype comparisons. We detail how to decompose quantum communication terminals into functional layers defining hardware, software, and middleware concerns, and we describe how each layer behaves. Using the super-dense coding protocol as a test case, we describe implementations of both the transmitter and receiver, and we present results from numerical simulations of the behavior. We find that while the theoretical benefits of super dense coding are maintained, there is a classical overhead associated with the full implementation.

quantum communication↗

Development of a Markerless Deletion Mutagenesis System in Nitrate-Reducing Bacterium Rhodanobacter denitrificans

Rhodanobacter has been found as the dominant genus in aquifers contaminated with high concentrations of nitrate and uranium in Oak Ridge, TN, USA. The in situ stimulation of denitrification has been proposed as a potential method to remediate nitrate and uranium contamination. Among the Rhodanobacter species, Rhodanobacter denitrificans strains have been reported to be capable of denitrification and contain abundant metal resistance genes. However, due to the lack of a mutagenesis system in these strains, our understanding of the mechanisms underlying low-pH resistance and the ability to dominate in the contaminated environment remains limited. Here, we developed an in-frame markerless deletion system in two R. denitrificans strains. First, we optimized the growth conditions, tested antibiotic resistance, and determined appropriate transformation parameters in 10 Rhodanobacter strains. We then deleted the upp gene, which encodes uracil phosphoribosyltransferase, in R. denitrificans strains FW104-R3 and FW104-R5. The resulting strains were designated R3_Δupp and R5_Δupp and used as host strains for mutagenesis with 5-fluorouracil (5-FU) resistance as the counterselection marker to generate markerless deletion mutants. Further, to test the developed protocol, the narG gene encoding nitrate reductase was knocked out in the R3_Δupp and R5_Δupp host strains. As expected, the narG mutants could not grow in anoxic medium with nitrate as the electron acceptor. Overall, these results show that the in-frame markerless deletion system is effective in two R. denitrificans strains, which will allow for future functional genomic studies in these strains furthering our understanding of the metabolic and resistance mechanisms present in Rhodanobacter species.

59 BASIC BIOLOGICAL SCIENCES↗

Midmorning Point Sampling May Not Accurately Represent Nitrous Oxide Emissions Following Fertilizer Applications

A common approach for measuring N 2 O emissions is to collect midmorning or early evening gas samples from experiments utilizing the chamber-based flux methodology. However, due to high spatial and temporal variability, N 2 O estimates based on midmorning or early evening sampling may not provide accurate estimates of total emissions. This study determined the impact of sampling collection timing on the precision and accuracy of N 2 O emissions estimates. Nitrous oxide emissions, air and soil temperatures, and soil moisture were measured for 21 d following the application of 224 kg urea-N ha –1 on 20 Sept. 2017, 11 Oct. 2017, and 1 May 2018, at six time intervals (0130–0230, 0530–0630, 0930–1030, 1330–1430, 1730–1830, and 2130–2230 h) over a 24-h period. Based on multiple daily measurements, point samples collected between 0930 and 1030 h (midmorning) were inconsistent in their ability to predict N 2 O emissions. However, samples collected between 2130 and 2230 h (early evening) were similar to average emissions. The number of randomly collected point samples to be within 20% of the mean 80% of the time over a 21-d period ranged from 13 samples for fertilizer applied on 20 Sept. 2017 to 48 samples for fertilizer applied on 11 Oct. 2017. This research indicates that management and climatic variability affect N 2 O emissions, and that accurate sampling protocols vary across management and climates. To reduce uncertainty, N 2 O sampling protocol should be tested under conditions likely to occur and where possible, near-continuous measurement systems should be adopted.

54 ENVIRONMENTAL SCIENCES↗

High Temperature Electrolysis Pressurized Experiment Design, Operation, and Results

A new facility has been developed at the Idaho National Laboratory for pressurized testing of solid oxide electrolysis stacks. Pressurized operation is envisioned for large-scale hydrogen production plants, yielding higher overall efficiencies when the hydrogen product is to be delivered at elevated pressure for tank storage or pipelines. Pressurized operation also supports higher mass flow rates of the process gases with smaller components. The test stand can accommodate planar cells with dimensions up to 8.5 cm x 8.5 cm and stacks of up to 25 cells. It is also suitable for testing other cell and stack geometries including tubular cells. The pressure boundary for these tests is a water-cooled spool-piece pressure vessel designed for operation up to 5 MPa. Pressurized operation of a ten-cell internally manifolded solid oxide electrolysis stack has been successfully demonstrated up 1.5 MPa. The stack is internally manifolded and operates in cross-flow with an inverted-U flow pattern. Feed-throughs for gas inlets/outlets, power, and instrumentation are all located in the bottom flange. The entire spool piece, with the exception of the bottom flange, can be lifted to allow access to the internal furnace and test fixture. Lifting is accomplished with a motorized threaded drive mechanism attached to a rigid structural frame. Stack mechanical compression is accomplished using springs that are located inside of the pressure boundary, but outside of the hot zone. Initial stack heatup and performance characterization occurs at ambient pressure followed by lowering and sealing of the pressure vessel and subsequent pressurization. Pressure equalization between the anode and cathode sides of the cells and the stack surroundings is ensured by combining all of the process gases downstream of the stack. Steady pressure is maintained by means of a backpressure regulator and a digital pressure controller. A full description of the pressurized test apparatus is provided in this report. Results of initial testing showed the expected increase in open-cell voltage associated with elevated pressure. However, stack performance in terms of area-specific resistance was enhanced at elevated pressure due to better gas diffusion through the porous electrodes of the cells. Some issues such as cracked cells and seals were encountered during testing. Full resolution of these issues will require additional testing to identify the optimum test configurations and protocols.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗