Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time resolved imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Progress Report on Mockup Irradiation Capsule Fuel Measurements at LANSCE

Irradiation tests are a key component of nuclear fuel development and identifying typical and atypical regions in the irradiated fuel volume relies on very few characterization techniques. The goal of the effort reported here is to provide complementary measurements adding to the available parameter space for post irradiation examination as well as to inform subsequent hot cell PIE examinations by identifying typical and atypical regions with respect to microstructure, tomographic data, or isotope densities. Pulsed neutrons, enabling diffraction as well as energy-resolved neutron imaging and neutron absorption resonance spectroscopy, offer unique capabilities for this purpose. Time-of-flight neutron diffraction has the potential to offer efficient, non-destructive and non-contact microstructural characterization of irradiated fuel specimen with spatial resolution of 1 mm 3 to 1 cm 3 while for energy-resolved neutron imaging (and by extension tomography) a resolution of 100 μm 3 was demonstrated. The potential results include crystallinity vs. amorphous volumes and microstructural information such as phase compositions, lattice strains (indicative of residual stresses or chemistry variations) and textures from the diffraction data as well as distances (e.g. pellet to cladding), cracks, and isotope densities of minor actinides, fission products as well as fission gas partial pressures e.g. in the plenum from energy resolved neutron imaging.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Capability for time-resolved diffraction for material phase in extreme conditions (Q2 FY24 Report)

After a series of development experiments, a new x-ray diffraction diagnostic called FIDDLE (Flexible Imaging Diffraction Diagnostic for Laser Experiments) has been designed, built, and fielded on four shots at NIF. Here we document the initial performance of FIDDLE fielded as the detector in the time-resolved x-ray diffraction experimental platform. Early challenges with EMP have been documented using offline testing in the Target Diagnostics Factory to identify EMP leaks. These techniques were used to guide the application of shielding to weak spots where EM radiation was able to penetrate inside the diagnostic. Application of shielding was found to be effective at reducing EMP leaks, enabling detection of x-ray diffraction on three temporally separated frames during a high pressure (~1Mbar) experiment where lead (Pb) was observed to undergo a phase transition from HCP to BCC.

36 MATERIALS SCIENCE↗

Simultaneous 100-kHz Acetone Planar Laser-Induced Fluorescence and OH* Chemiluminescence in a Linear Non-Premixed Detonation Channel

Reactant mixing and combustion are investigated in an optically accessible, self-excited linear detonation combustor. The mixing field is captured using 100 kHz planar laser-induced fluorescence (PLIF) imaging of acetone as a tracer in the fuel supply, while 100 kHz chemiluminescence imaging of excited-state hydroxyl (OH*) radicals simultaneously resolves the evolution of the detonation wave. Time sequences are acquired over multiple detonation cycles in each test, with acetone-PLIF images collected along multiple orthogonal planes to reveal the complex three-dimensional topography of the fuel distribution. The instantaneous and phase averaged acetone-PLIF images enable measurement of key fuel injection characteristics, such as the injector recovery time, fuel jet velocity, and refill height for a range of operating conditions. Instantaneous and phase-averaged measurements of acetone-PLIF with the time-coincident OH* chemiluminescence images also reveal a number key features, such as fuel stratification and weak detonation in the injector near field, incomplete combustion and deflagration behind the detonation wave, vitiation and deflagration of reactants ahead of the detonation wave, and fuel and oxidizer recovery time mismatch leading to combustion inefficiency. These measurements significantly enhance the ability to obtain detailed information on the intracycle and intercycle spatiotemporal evolution of the reactant refill process and its coupled effects on the detonation wave structure and propagation.

Propulsion↗

Cathodoluminescence for the 21st century: Learning more from light

Cathodoluminescence (CL) is the emission of light from a material in response to excitation by incident electrons. The technique has had significant impact in the characterization of semiconductors, minerals, ceramics, and many nanostructured materials. Since 2010, there have been a number of innovative developments that have revolutionized and expanded the information that can be gained from CL and broadened the areas of application. While the primary historical application of CL was for spatial mapping of luminescence variations (e.g., imaging dark line defects in semiconductor lasers or providing high resolution imaging of compositional variations in geological materials), new ways to collect and analyze the emitted light have expanded the science impact of CL, particularly at the intersection of materials science and nanotechnology. Current developments include (1) angular and polarized CL, (2) advances in time resolved CL, (3) far-field and near-field transport imaging that enable drift and diffusion information to be obtained through real space imaging, (4) increasing use of statistical analyses for the study of grain boundaries and interfaces, (5) 3D CL including tomography and combined work utilizing dual beam systems with CL, and (6) combined STEM/CL measurements that are reaching new levels of resolution and advancing single photon spectroscopy. This focused review will first summarize the fundamentals and then briefly describe the state-of-the-art in conventional CL imaging and spectroscopy. We also review these recent novel experimental approaches that enable added insight and information, providing a range of examples from nanophotonics, photovoltaics, plasmonics, and studies of individual defects and grain boundaries.

14 SOLAR ENERGY↗

Stereoscopic Imaging in Hypersonics Boundary Layers using Planar Laser-Induced Fluorescence

Stereoscopic time-resolved visualization of three-dimensional structures in a hypersonic flow has been performed for the first time. Nitric Oxide (NO) was seeded into hypersonic boundary layer flows that were designed to transition from laminar to turbulent. A thick laser sheet illuminated and excited the NO, causing spatially-varying fluorescence. Two cameras in a stereoscopic configuration were used to image the fluorescence. The images were processed in a computer visualization environment to provide stereoscopic image pairs. Two methods were used to display these image pairs: a cross-eyed viewing method which can be viewed by naked eyes, and red/blue anaglyphs, which require viewing through red/blue glasses. The images visualized three-dimensional information that would be lost if conventional planar laser-induced fluorescence imaging had been used. Two model configurations were studied in NASA Langley Research Center's 31-Inch Mach 10 Air Wind tunnel. One model was a 10 degree half-angle wedge containing a small protuberance to force the flow to transition. The other model was a 1/3-scale, truncated Hyper-X forebody model with blowing through a series of holes to force the boundary layer flow to transition to turbulence. In the former case, low flowrates of pure NO seeded and marked the boundary layer fluid. In the latter, a trace concentration of NO was seeded into the injected N2 gas. The three-dimensional visualizations have an effective time resolution of about 500 ns, which is fast enough to freeze this hypersonic flow. The 512x512 resolution of the resulting images is much higher than high-speed laser-sheet scanning systems with similar time response, which typically measure 10-20 planes.

Danehy, Paul M.↗

Spatial distribution of relaxation behavior on the surface of ferroelectric relaxor in the ergodic phase

Spatial homogeneity of polarization relaxation behavior on the surface of 0.9Pb(Mg{sub 1/3}Nb{sub 2/3})O{sub 3}-0.1PbTiO{sub 3} crystals in the ergodic relaxor phase is studied using three-dimensional time-resolved spectroscopic piezoresponse force microscopy. The number of statistically independent components in the spectroscopic image is determined using principal component analysis. In the studied measurement time interval, the spectra generally exhibit logarithmic behavior with spatially varying slope and offset, and the statistical distribution of these parameters are studied. The data illustrate the presence of mesoscopic heterogeneity in the dynamics of the relaxation behavior that can be interpreted as spatial variation in local Vogel-Fulcher temperatures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dose calculation for permanent prostate implants incorporating spatially anisotropic linearly time-resolving edema

Purpose: The objectives of this study were (i) to develop a dose calculation method for permanent prostate implants that incorporates a clinically motivated model for edema and (ii) to illustrate the use of the method by calculating the preimplant dosimetry error for a reference configuration of {sup 125}I, {sup 103}Pd, and {sup 137}Cs seeds subject to edema-induced motions corresponding to a variety of model parameters. Methods: A model for spatially anisotropic edema that resolves linearly with time was developed based on serial magnetic resonance imaging measurements made previously at our center to characterize the edema for a group of n=40 prostate implant patients [R. S. Sloboda et al., ''Time course of prostatic edema post permanent seed implant determined by magnetic resonance imaging,'' Brachytherapy 9, 354-361 (2010)]. Model parameters consisted of edema magnitude, {Delta}, and period, T. The TG-43 dose calculation formalism for a point source was extended to incorporate the edema model, thus enabling calculation via numerical integration of the cumulative dose around an individual seed in the presence of edema. Using an even power piecewise-continuous polynomial representation for the radial dose function, the cumulative dose was also expressed in closed analytical form. Application of the method was illustrated by calculating the preimplant dosimetry error, RE{sub preplan}, in a 5x5x5 cm{sup 3} volume for {sup 125}I (Oncura 6711), {sup 103}Pd (Theragenics 200), and {sup 131}Cs (IsoRay CS-1) seeds arranged in the Radiological Physics Center test case 2 configuration for a range of edema relative magnitudes ({Delta}=[0.1,0.2,0.4,0.6,1.0]) and periods (T=[28,56,84] d). Results were compared to preimplant dosimetry errors calculated using a variation of the isotropic edema model developed by Chen et al. [''Dosimetric effects of edema in permanent prostate seed implants: A rigorous solution,'' Int. J. Radiat. Oncol., Biol., Phys. 47, 1405-1419 (2000)]. Results: As expected, RE{sub preplan} for our edema model indicated underdosage in the calculation volume with a clear dependence on seed and calculation point positions, and increased with increasing values of {Delta} and T. Values of RE{sub preplan} were generally larger near the ends of the virtual prostate in the RPC phantom compared with more central locations. For edema characteristics similar to the population average values previously measured at our center, i.e., {Delta}=0.2 and T=28 d, mean values of RE{sub preplan} in an axial plane located 1.5 cm from the center of the seed distribution were 8.3% for {sup 131}Cs seeds, 7.5% for {sup 103}Pd seeds, and 2.2% for {sup 125}I seeds. Maximum values of RE{sub preplan} in the same plane were about 1.5 times greater. Note that detailed results strictly apply only for loose seed implants where the seeds are fixed in tissue and move in synchrony with that tissue. Conclusions: A dose calculation method for permanent prostate implants incorporating spatially anisotropic linearly time-resolving edema was developed for which cumulative dose can be written in closed form. The method yields values for RE{sub preplan} that differ from those for spatially isotropic edema. The method is suitable for calculating pre- and postimplant dosimetry correction factors for clinical seed configurations when edema characteristics can be measured or estimated.

60 APPLIED LIFE SCIENCES↗

Surface Domain Structures and Mesoscopic Phase Transition in Relaxor Ferroelectrics

Relaxor ferroelectrics are a prototypical example of ferroic systems in which interplay between atomic disorder and order parameters gives rise to emergence of unusual properties, including non-exponential relaxations, memory effects, polarization rotations, and broad spectrum of bias- and temperatureinduced phase transitions. Despite more than 40 years of extensive research following the original discovery of ferroelectric relaxors by the Smolensky group, the most basic aspect of these materials the existence and nature of order parameter has not been understood thoroughly. Using extensive imaging and spectroscopic studies by variable-temperature and time resolved piezoresponse force microscopy, we fi nd that the observed mesoscopic behavior is consistent with the presence of two effective order parameters describing dynamic and static parts of polarization, respectively. The static component gives rise to rich spatially ordered systems on the 100 nm length scales, and are only weakly responsive to electric fi eld. The surface of relaxors undergoes a mesoscopic symmetry breaking leading to the freezing of polarization fl uctuations and shift of corresponding transition temperature.

Kholkin, Andrei↗

Innovative approaches to neutron beam optimization: A case study of FP14 at LANSCE

This paper describes an experimental method to acquire high resolution energy- and spatially- resolved neutron beam spots using the time-gated neutron imaging system with Teledyne Pi-MAX4 camera. These experimental data offer a unique opportunity for benchmarking beam spot simulations. High-quality simulations depend significantly on a high-fidelity geometry model, which can be challenging for legacy facilities. We informed our MCNPX geometry model by latest metrology survey employing Leica laser tracker ATS600. It gave us a high fidelity description of our facility geometry. Such a robust integration of novel tools and methods yields a previously unattainable level of accuracy in both predicting and capturing neutron beam spots, marking a notable advancement over traditional methods reliant on static image plates. Here, to demonstrate the practical application of these tools, we are showing a non-uniform beam spot challenge at our Flight Path 14 (FP14) at the Los Alamos Neutron Science Center (LANSCE). Our precise MCNPX prediction of beam spot shifting as function of neutron energy was confirmed by experimental beam spot measured with extremely high level of detail. Results of this research demonstrate a significant leap in neutron beam optimization at LANSCE and set a new benchmark in beam spot characterization. The advanced methods presented here have potential for adoption at similar research facilities worldwide, aiming at substantial improvement in neutron beam delivery for experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 4D view on the evolution of metamorphic dehydration reactions

Metamorphic reactions influence the evolution of the Earth’s crust in a range of tectonic settings. For example hydrous mineral dehydration in a subducting slab can produce fluid overpressures which may trigger seismicity. During reaction the mechanisms of chemical transport, including water expulsion, will dictate the rate of transformation and hence the evolution of physical properties such as fluid pressure. Despite the importance of such processes, direct observation of mineral changes due to chemical transport during metamorphism has been previously impossible both in nature and in experiment. Using time-resolved (4D) synchrotron X-ray microtomography we have imaged a complete metamorphic reaction and show how chemical transport evolves during reaction. We analyse the dehydration of gypsum to form bassanite and H 2 O which, like most dehydration reactions, produces a solid volume reduction leading to the formation of pore space. This porosity surrounds new bassanite grains producing fluid-filled moats, across which transport of dissolved ions to the growing grains occurs via diffusion. As moats grow in width, diffusion and hence reaction rate slow down. Our results demonstrate how, with new insights into the chemical transport mechanisms, we can move towards a more fundamental understanding of the hydraulic and chemical evolution of natural dehydrating systems.

58 GEOSCIENCES↗

Molecular insights into photostability of fluorinated organic photovoltaic blends: role of fullerene electron affinity and donor–acceptor miscibility

In this report, the photostability of certain organic photovoltaic (OPV) active layers was demonstrated to improve by as much as a factor of five under white light illumination in air with the use of 1,7-bis-trifluoromethylfullerene (C 60 (CF 3 ) 2 ) as the acceptor in place of PC 60 BM. However, the results were highly dependent on the structure and functionality within the donor material. Twelve combinations of active layer blends were studied, comprised of six different high-performance donor polymers (two fluorinated and four non-fluorinated donors) and two fullerene acceptors (PC 60 BM and C 60 (CF 3 ) 2 ). The relative rates of irreversible photobleaching of the active layer blends were found to correlate well with the electron affinity of the fullerene when the polymer and fullerene were well blended, but a full rationalization of the photobleaching data requires consideration of both the electron affinity of the fullerene as well as the relative miscibility of the polymer–fullerene components in the blend. Miscibility of those components was probed using a combination of time-resolved photoluminescence (TRPL) measurements and scanning tunneling microscopy (STM) imaging. The presence of fluorinated aromatic units in the donor materials tend to promote more intimate mixing with C 60 (CF 3 ) 2 as compared to PC 60 BM. The full results of these photobleaching studies and measurements of donor–acceptor miscibility, considered alongside additional photoconductance measurements and preliminary device work, provide new molecular optimization insights for improving the long-term stability of OPV active layers.

36 MATERIALS SCIENCE↗

Turbulent eddies in a compressible jet in crossflow measured using pulse-burst particle image velocimetry

Pulse-burst Particle Image Velocimetry(PIV) has been employed to acquire time-resolved data at 25 kHz of a supersonic jet exhausting into a subsonic compressible crossflow. Data were acquired along the windward boundary of the jet shear layer and used to identify turbulenteddies as they convect downstream in the far-field of the interaction. Eddies were found to have a tendency to occur in closely spaced counter-rotating pairs and are routinely observed in the PIV movies, but the variable orientation of these pairs makes them difficult to detect statistically. Correlated counter-rotating vortices are more strongly observed to pass by at a larger spacing, both leading and trailing the reference eddy. This indicates the paired nature of the turbulenteddies and the tendency for these pairs to recur at repeatable spacing. Velocity spectra reveal a peak at a frequency consistent with this larger spacing between shear-layer vortices rotating with identical sign. The spatial scale of these vortices appears similar to previous observations of compressible jets in crossflow. Furthermore,super-sampled velocity spectra to 150 kHz reveal a power-law dependency of –5/3 in the inertial subrange as well as a –1 dependency at lower frequencies attributed to the scales of the dominant shear-layer eddies.

42 ENGINEERING↗

Femtosecond wavelength-tunable laser system using gain managed nonlinear amplifier

Optical parametric amplifiers require a seed energy at the spectral range of interest for amplification. In the case of pulsed laser systems, seed pulse characteristics such as spectral energy density and spectral uniformity influence laser system design and performance. In this letter, we present the design and modeling of a few micro-joules, wavelength-tunable, femtosecond parametric amplifier system. We employ a gain-managed nonlinear fiber amplifier output as the seed pulse. This seed pulse is relatively uniform across its bandwidth from 1010 to 1180 nm. Its spectral energy density averages 600 pJ/nm, 30 times higher than conventional counterparts. The overall amplification gain is 175, and the conversion efficiency is 17.5%. The inherent quasi-linear chirp of the seed pulse is utilized to alter the output wavelength. Our tunable femtosecond laser is an enabling technology for high-demand applications such as time-resolved spectroscopy, nonlinear and advanced material research, and biomedical imaging and microscopy modalities.

47 OTHER INSTRUMENTATION↗

Tomographic optical emission spectroscopy of an atmospheric pressure plasma jet and surface ionization waves on planar and structured surfaces

Here in this paper, an approach for 3D plasma structure diagnostics using tomographic optical emission spectroscopy (Tomo-OES) of a nanosecond pulsed atmospheric pressure plasma jet (APPJ) is presented. In contrast to the well-known Abel inversion, Tomo-OES does not require cylindrical symmetry to recover 3D distributions of plasma light emission. Instead, many 2D angular projections are measured with intensified cameras and the multiplicative algebraic reconstruction technique is used to recover the 3D distribution of light emission. This approach solves the line-of-sight integration problem inherent to optical diagnostics, allowing recovery of localized OES information within the plasma that can be used to better infer plasma parameters within complex plasma structures. Here, Tomo-OES was applied to investigate an APPJ operated with helium in ambient air and impinging on planar and structured dielectric surfaces. Surface charging caused the guided streamer from the APPJ to transition to a surface ionization wave (SIW) that propagated along the surface. The SIW experienced variable geometrical and electrical material properties as it propagated, leading to 3D configurations that were non-symmetric and spatially complex. Light emission from He, N$_2^+$, and N2 were imaged at ten angular projections and the respective time-resolved 3D emission distributions in the plasma were then reconstructed. The spatial resolution of each tomographic reconstruction was 7.4 µm and the temporal resolution was 5 ns, sufficient to observe the guided streamer and the effects of the structured surface on the SIW. Emission from He showed the core of the jet and emission from N$_2^+$ and N2 indicated effects of entrainment of ambient air. Penning ionization of N2 created a ring or outer layer of N$_2^+$ that spatially converged to form the 'plasma bullet' or spatially diverged across a surface as part of a SIW. The SIW entered trenches of size 150 µm, leading to decreases in plasma light emission in regions above the trenches. The plasma light emission was higher in some regions with trenches, possibly due to effects of field enhancement.

plasma interactions with complex surfaces↗

Inorganic voltage nanosensors for bioelectricity studies in bacterial communities

We developed both membrane potential nanosensors (MPNs) and voltage sensing dyes (VSDs), and quantitative optical measurement tools to measure membrane potential (MP) at the level of a single bacterial cell, with voltage resolution of ~10 mV changes. Our approach relied on (i) novel MPNs and novel VSDs that measures MPs via fluorescence lifetime; (ii) a quantitative approach to fluorescence lifetime imaging microscopy (FLIM) data based on a novel time-resolved camera and phasor analysis. We demonstrate MP measurements over time for single bacterial cells.

59 BASIC BIOLOGICAL SCIENCES↗

Seeing in with X-rays: 4D Strain and Thermometry Measurements for Thermal-Mechanical Testing

Understanding temperature-dependent material decomposition and structural deformation induced by combined thermal-mechanical environments is critical for safety qualification of hardware under accident scenarios. Seeing in with X-rays elucidated the physics necessary to develop X-ray strain and thermometry diagnostics for use in optically opaque environments. Two parallel thermometry schemes were explored: X-ray fluorescence and X-ray diffraction of inorganic doped ceramics– colloquially known as thermographic phosphors. Two parallel surface strain techniques–Path-Integrated Digital Image Correlation and Frequency Multiplexed Digital Image Correlation–were demonstrated. Finally, preliminary demonstration of time-resolved digital volume correlation was performed by taking advantage of limited view reconstruction techniques. Additionally, research into blended ceramic-metal coatings was critical to generating intrinsic thermographic patterns for the future combination of X-ray strain and thermometry measurements.

36 MATERIALS SCIENCE↗

Spatial Distribution of Resonance in the Velocity Field for Transonic Flow over a Rectangular Cavity

Pulse-burst particle image velocimetry (PIV) has been used to acquire time-resolved data at 37.5 kHz of the flow over a finite-width rectangular cavity at Mach 0.8. Power spectra of the PIV data reveal four resonance modes that match the frequencies detected simultaneously using high-frequency wall pressure sensors but whose magnitudes exhibit spatial dependence throughout the cavity. Spatio-temporal cross-correlations of velocity to pressure were calculated after bandpass filtering for specific resonance frequencies. Cross-correlation magnitudes express the distribution of resonance energy, revealing local maxima and minima at the edges of the shear layer attributable to wave interference between downstream- and upstream-propagating disturbances. Turbulence intensities were calculated using a triple decomposition and are greatest in the core of the shear layer for higher modes, where resonant energies ordinarily are lower. Most of the energy for the lowest mode lies in the recirculation region and results principally from turbulence rather than resonance. Together, the velocity-pressure cross-correlations and the triple-decomposition turbulence intensities explain the sources of energy identified in the spatial distributions of power spectra amplitudes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗