Search NASA⌕ Search

SEARCH · Search NASA

Results for “Volatile analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Analysis of organogenic compounds in Apollo 11, 12, and 14 lunar samples.

DCl was used to distinguish hydrocarbons produced by acid treatment from hydrocarbons originally present in the samples when volatiles released by acid and thermal treatments from Apollo 11, 12, and 14 lunar samples were studied by quadrupole mass spectrometry and gas chromatography mass spectrometry. Multiple ion plotting permitted separation of deuterated from nondeuterated hydrocarbons in the DCl products. Stepwise thermal treatment was used to distinguish the source of the volatile compounds. The presence of LM rocket exhaust products was traced in two samples, and the presence of high-temperature stable nitrides in some samples is indicated.

Flory, D. A.↗

Lunar sample analysis

Flameless atomic abosrption, X-ray photoemission spectroscopy, ferromagnetic resonance, scanning electron microscopy, and Moessbauer spectroscopy were used to investigate the evolution of the lunar regolith, the transport of volatile trace metals, and the surface composition of lunar samples. The development of a model for lunar volcanic eruptions is also discussed.

Housley, R. M.↗

WF/PC internal molecular contamination during system thermal-vacuum test

During the recent system thermal vacuum test of the Wide-Field/Planetary Camera (WF/PC), instrumentation was added to the WF/PC to characterize the internal molecular contamination and verify the instrument throughput down to 1470 angstroms. Analysis of data elements revealed two contaminants affecting the far-ultraviolet (FUV) performance of the WF/PC. The one contaminant (heavy volatile) is correlated with the electronic and housing temperature, and the contamination is significantly reduced when the electronics are operated below plus 8 degrees to plus 10 degrees C. The other contaminant (light volatile) is controlled by the heat pipe temperature, and the contamination is significantly reduced when the Thermal Electric Cooler (TEC) hot-junction temperature is below minus 40 degrees to minus 50 degrees C. The utility of contamination sensors located behind instruments during system tests was demonstrated.

Taylor, Daniel M.↗

SiC Recession Due to SiO2 Scale Volatility Under Combustor Conditions

One of today's most important and challenging technological problems is the development of advanced materials and processes required to design and build a fleet of supersonic High Speed Civil Transport (HSCT) airliners, a follow-up to the Concorde SST. The innovative combustor designs required for HSCT engines will need high-temperature materials with long-term environmental stability. Higher combustor liner temperatures than today's engines and the need for lightweight materials will require the use of advanced ceramic-matrix composites (CMC's) in hot-section components. The HSCT is just one example being used to demonstrate the need for such materials. This thesis evaluates silicon carbide (SiC) as a potential base material for HSCT and other similar applications. Key issues are the environmental durability for the materials of interest. One of the leading combustor design schemes leads to an environment which will contain both oxidizing and reducing gas mixtures. The concern is that these environments may affect the stability of the silica (SiO2) scale on which SiC depends for environmental protection. A unique High Pressure Burner Rig (HPBR) was developed to simulate the combustor conditions of future gas turbine engines, and a series of tests were conducted on commercially available SiC material. These tests are intended as a feasibility study for the use of these materials in applications such as the HSCT. Linear weight loss and surface recession of the SiC is observed as a result of SiO2 volatility for both fuel-lean and fuel-rich gas mixtures. These observations are compared and agree well with thermogravimetric analysis (TGA) experiments. A strong Arrhenius-type temperature dependence exists. In addition, the secondary dependencies of pressure and gas velocity are defined. As a result, a model is developed to enable extrapolation to points outside the experimental space of the burner rig, and in particular, to potential gas turbine engine conditions.

Robinson, Raymond Craig↗

Impacts of Microbial Growth on the Air Quality of the International Space Station

An understanding of the various sources of non-methane volatile organic compounds (NMVOCs) is one facet to ensuring the habitability of crewed spacecraft. Even though the International Space Station (ISS) atmosphere is relatively well characterized in terms of what is in the atmosphere and approximately how much, linking the majority of these trace contaminants detected to their source is virtually impossible. Albeit a few of can be associated to a single source, the majority of these trace contaminants have their origins from multiple sources. On crewed spacecraft such as ISS, trace contaminants are broadly categorized as either coming from equipment, which includes systems and payloads, or from the metabolic processes of the crew members. Such widely encompassing categories clearly illustrate the difficulty in linking air contaminants to their source(s). It is well known that microbial growth in ISS can flourish if left unchecked. Although processes are in place to limit microbial growth, in reality, microbial growth has pervaded the habitable environment of ISS. This is simply a consequence of having crewed spacecraft, as humans are the largest contributor to the bioload. As with crew members, microbes also have metabolic processes which, in many ways, are comparable to human metabolism. As such, it can be expected that microbial growth can lead to the release of volatile organic compounds into the ISS atmosphere. Given a large enough microbial population, the impact to the air quality of ISS can be potentially large. A survey of the microbiology found in ISS will be presented as well as the possible types of volatile organic compounds that can result from such organisms. This will be correlated to the observations provided by ground-based analysis of ISS atmosphere samples.

Macatangay, Ariel V.↗

Impacts of Microbial Growth on the Air Quality of the International Space Station

An understanding of the various sources of non-methane volatile organic compounds (NMVOCs) is one facet to ensuring the habitability of crewed spacecraft. Even though the International Space Station (ISS) atmosphere is relatively well characterized in terms of what is in the atmosphere and approximately how much, linking the majority of these trace contaminants detected to their source is virtually impossible. Albeit a few of can be associated to a single source, the majority of these trace contaminants have their origins from multiple sources. On crewed spacecraft such as ISS, trace contaminants are broadly categorized as either coming from equipment, which includes systems and payloads, or from the metabolic processes of the crew members. Such widely encompassing categories clearly illustrate the difficulty in linking air contaminants to their source(s). It is well known that microbial growth in ISS can flourish if left unchecked. Although processes are in place to limit microbial growth, in reality, microbial growth has pervaded the habitable environment of ISS. This is simply a consequence of having crewed spacecraft, as humans are the largest contributor to the bioload. As with crew members, microbes also have metabolic processes which, in many ways, are comparable to human metabolism. As such, it can be expected that microbial growth can lead to the release of volatile organic compounds into the ISS atmosphere. Given a large enough microbial population, the impact to the air quality of ISS can be potentially large. A survey of the microbiology found in ISS will be presented as well as the possible types of volatile organic compounds that can result from such organisms. This will be correlated to the observations provided by ground-based analysis of ISS atmosphere samples

Macatangay, Ariel V.↗

The Sample Analysis at Mars Investigation and Instrument Suite

The Sample Analysis at Mars (SAM) investigation of the Mars Science Laboratory (MSL) addresses the chemical and isotopic composition of the atmosphere and volatiles extracted from solid samples. The SAM investigation is designed to contribute substantially to the mission goal of quantitatively assessing the habitability of Mars as an essential step in the search for past or present life on Mars. SAM is a 40 kg instrument suite located in the interior of MSL's Curiosity rover. The SAM instruments are a quadrupole mass spectrometer, a tunable laser spectrometer, and a 6-column gas chromatograph all coupled through solid and gas processing systems to provide complementary information on the same samples. The SAM suite is able to measure a suite of light isotopes and to analyze volatiles directly from the atmosphere or thermally released from solid samples. In addition to measurements of simple inorganic compounds and noble gases SAM will conduct a sensitive search for organic compounds with either thermal or chemical extraction from sieved samples delivered by the sample processing system on the Curiosity rover's robotic arm,

Mahaffy, Paul↗

Effect of the Presence of Chlorates and Perchlorates on the Pyrolysis of Organic Compounds: Implications for Measurements Done with the SAM Experiment Onboard the Curiosity Rover

The Mars Science Laboratory (MSL) Curiosity Rover carries a suite of instruments, one of which is the Sample Analysis at Mars (SAM) experiment. SAM is devoted to the in situ molecular analysis of gases evolving from solid samples collected by Curiosity on Mars surface/sub-surface. Among its three analytical devices, SAM has a gaschromatograph coupled to a quadrupole mass spectrometer (GC-QMS). The GC-QMS is devoted to the separation and identification of organic and inorganic material. Before proceeding to the GC-QMS analysis, the solid sample collected by Curiosity is subjected to a thermal treatment thanks to the pyrolysis oven to release the volatiles into the gas processing system. Depending on the sample, a derivatization method by wet chemistry: MTBSTFA of TMAH can also be applied to analyze the most refractory compounds. The GC is able to separate the organic molecules which are then detected and identified by the QMS (Figure 1). For the second time after the Viking landers in 1976, SAM detected chlorinated organic compounds with the pyrolysis GC-QMS experiment. The detection of perchlorates salts (ClO4-) in soil at the Phoenix Landing site suggests that the chlorohydrocarbons detected could come from the reaction of organics with oxychlorines. Indeed, laboratory pyrolysis experiments have demonstrated that oxychlorines decomposed into molecular oxygen and volatile chlorine (HCl and/or Cl2) when heated which then react with the organic matter in the solid samples by oxidation and/or chlorination processes.

Millan, M.↗

Space weathering features of anhydrous minerals in fine grains from the C-type asteroid Ryugu

Materials exposed to the space environment are expected to show optically and chemically modified properties. This process is called as space weathering and is caused mainly by micrometeoroid bombardments and solar wind implantation [1]. Thus far, the space weathering of carbonaceous asteroids has not been well understood. Regolith samples were successfully recovered from C-type asteroid Ryugu by the Hayabusa mission [2]. Ryugu samples will provide insights into the ongoing space weathering of Ryugu [3]. In this study, we investigated the space weathering of anhydrous minerals including iron sulfides, magnetite, and carbonates, which are major reservoirs of volatiles including carbon, oxygen, and sulfur in Ryugu materials. We performed scanning electron microscopy (SEM) and transmission/scanning transmission electron microscopy (TEM/STEM) analysis for Ryugu samples.

Toru Matsumoto↗

Investigation of Geomorphological Signatures of Permafrost in the Polar Lunar Areas With VIPER

A study of images of the polar regions shows that small craters near the poles of the Moon are distinguished by the following features: 1. they have a smoother shape - see Fig (a); 2. patterned ground (“wrinkled skin”) is often observed in and around the crater - see Figs (a,b,c); 3. outside the craters landslides and cracks are noticeable - see Fig (d); 4. layers or scarps are often visible on the inner slope - see Fig (e). These features (scarps and patterned ground) are typical for Martian craters in the permafrost zone (see Fig f), as well as for similar zones on Earth. It is hypothesized that these features of lunar craters are associated with the presence of permafrost in the polar regions of the Moon. In 2023, the VIPER rover will investigate the distribution of ice (volatile) deposits in the region of the Moon's South Pole. VIPER navigation cameras represent a unique opportunity for the geomorphological analysis of the lunar surface and the study of physical properties of regolith due to multiple key factors: - A large number of high-quality digital images with a good resolution of the South Pole of the Moon, which is a key region for the landing of manned expeditions. - A low position of the Sun, which generates long shadows, creates favorable conditions for object recognition algorithms. - A presence of a rover track in the images enables VIPER wheels to be used as tools for the study of the regolith and the development of a geotechnical model of regolith in the South Pole region. Rover navigation cameras will allow investigation of the distribution and shape of small craters and other structures along the path of the rover and test the hypothesis about geomorphological signatures of permafrost in the lunar polar areas. If a relationship between characteristics of lunar craters and the distribution of permafrost is confirmed, this will open a possibility to remotely determine the deposits of lunar ice from satellite imagery.

VIPER↗

C-O-H ratios of silicate melt inclusions in basalts from the Galapagos Spreading Center near 95 degrees W: a laser decrepitation mass spectrometry study

Volatile ratios (primarily of H2O and CO2) in individual silicate melt (glass) inclusions in minerals have been analyzed using laser volatilization and mass spectrometry. A Nd-glass laser was used to produce 50-micrometer diameter pits in silicate melt inclusions. Released volatiles were analyzed directly with a computer-controlled quadrupole mass spectrometer. The detection limits for CO2 and H2O were on the order of 3 x 10(-14) and 3 x 10(-13) moles, respectively. The reproducibility for CO2/H2O was better than +/- 9%. The total range of volatile ratios from vitreous silicate glass inclusions contained in a suite of Galapagos lavas were: 0.018 to 1.193 for CO2/H2O; 0.002 to 0.758 for CO/H2O; 0 to 0.454 for CH4/H2O; and 0 to 0.432 for Ar/H2O. The mean CO2/H2O from the propagating rift (0.245 +/- 0.068) silicate glass inclusions is significantly lower than that of the actively failing rift (0.641 +/- 0.241); this difference probably reflects different degrees of degassing during magmatic histories for the two regions. Relatively undifferentiated failing rift magmas must have relatively short crustal residence times prior to eruption and, therefore, have not undergone significant degassing of CO2, as would appear to be the case for the more highly fractionated propagating rift magmas. The laser-mass spectrometric system described herein has the ability to act as a point-source probing device that can differentiate between the various volatile sites in minerals and rocks (as well as synthetic materials) on a micrometer scale.

NASA Discipline Exobiology↗

Precision cleaning verification of fluid components by air/water impingement and total carbon analysis

NASA personnel at Kennedy Space Center's Material Science Laboratory have developed new environmentally sound precision cleaning and verification techniques for systems and components found at the center. This technology is required to replace existing methods traditionally employing CFC-113. The new patent-pending technique of precision cleaning verification is for large components of cryogenic fluid systems. These are stainless steel, sand cast valve bodies with internal surface areas ranging from 0.2 to 0.9 sq m. Extrapolation of this technique to components of even larger sizes (by orders of magnitude) is planned. Currently, the verification process is completely manual. In the new technique, a high velocity, low volume water stream impacts the part to be verified. This process is referred to as Breathing Air/Water Impingement and forms the basis for the Impingement Verification System (IVS). The system is unique in that a gas stream is used to accelerate the water droplets to high speeds. Water is injected into the gas stream in a small, continuous amount. The air/water mixture is then passed through a converging/diverging nozzle where the gas is accelerated to supersonic velocities. These droplets impart sufficient energy to the precision cleaned surface to place non-volatile residue (NVR) contaminants into suspension in the water. The sample water is collected and its NVR level is determined by total organic carbon (TOC) analysis at 880 C. The TOC, in ppm carbon, is used to establish the NVR level. A correlation between the present gravimetric CFC113 NVR and the IVS NVR is found from experimental sensitivity factors measured for various contaminants. The sensitivity has the units of ppm of carbon per mg/sq ft of contaminant. In this paper, the equipment is described and data are presented showing the development of the sensitivity factors from a test set including four NVRs impinged from witness plates of 0.05 to 0.75 sq m.

Barile, Ronald G.↗

Characterization of urania vaporization with transpiration coupled thermogravimetry

Determining equilibrium vapor pressures of materials is made easier by transpiration measurements. However, the traditional technique involves condensing the volatiles entrained in a carrier gas outside of the hot measurement zone. One potential problem is deposition en route to a cooled collector. Thermogravimetric analysis (TGA) can be used to measure in situ mass loss due to vaporization and therefore obviate the need to analyze the entire gas train due to premature plating of vapor species. Therefore, a transpiration coupled TGA technique was used to determine equilibrium pressures of UO3 gas over fluorite structure UO2+x and U3O8 at T = (1573 and 1773) K. Moreover, we compared to calculations from models and databases in the open literature. Our study gives clarity to the thermochemical data for UO3 gas and validates the mass loss transpiration method using thermogravimetry for determining equilibrium vapor pressures of non-stoichiometric oxides.

36 MATERIALS SCIENCE↗

Aerosol synthesis and Rietveld analysis of tetragonal (β₁) PdZn

The {beta}{sub 1} PdZn intermetallic of nominal 50:50 Pd:Zn at% was synthesized using an aerosol method. The aerosol method provided atomically mixed precursor oxy-nitrate powder that was then reduced to form {beta}{sub 1} PdZn, having a surface area amenable to catalytic measurements. Formation of the {beta}{sub 1} PdZn during reduction was found to occur rapidly (4 h) and at moderate temperature (500 C), serving to minimize the loss of volatile Zn. Chemical and structural characterization confirms that {beta}{sub 1} PdZn (95-99 wt% phase pure) of the same composition as the nitrate feedstock solution can be prepared using this method. Detailed structural analysis shows that this material contains little or no vacancies and minimal Pd/Zn disorder.

36 MATERIALS SCIENCE↗

Precision Cleaning Verification of Fluid Components by Air/Water Impingement and Total Carbon Analysis

NASA personnel at Kennedy Space Center's Material Science Laboratory have developed new environmentally sound precision cleaning and verification techniques for systems and components found at the center. This technology is required to replace existing methods traditionally employing CFC-113. The new patent-pending technique of precision cleaning verification is for large components of cryogenic fluid systems. These are stainless steel, sand cast valve bodies with internal surface areas ranging from 0.2 to 0.9 m(exp 2). Extrapolation of this technique to components of even larger sizes (by orders of magnitude) is planned. Currently, the verification process is completely manual. In the new technique, a high velocity, low volume water stream impacts the part to be verified. This process is referred to as Breathing Air/Water Impingement and forms the basis for the Impingement Verification System (IVS). The system is unique in that a gas stream is used to accelerate the water droplets to high speeds. Water is injected into the gas stream in a small, continuous amount. The air/water mixture is then passed through a converging-diverging nozzle where the gas is accelerated to supersonic velocities. These droplets impart sufficient energy to the precision cleaned surface to place non-volatile residue (NVR) contaminants into suspension in the water. The sample water is collected and its NVR level is determined by total organic carbon (TOC) analysis at 880 C. The TOC, in ppm carbon, is used to establish the NVR level. A correlation between the present gravimetric CFC-113 NVR and the IVS NVR is found from experimental sensitivity factors measured for various contaminants. The sensitivity has the units of ppm of carbon per mg-ft(exp 2) of contaminant. In this paper, the equipment is described and data are presented showing the development of the sensitivity factors from a test set including four NVR's impinged from witness plates of 0.05 to 0.75 m(exp 2).

Barile, Ronald G.↗

Predictions of the glass transition temperature and viscosity of organic aerosols from volatility distributions

Abstract. Volatility and viscosity are important properties of organic aerosols (OA), affecting aerosol processes such as formation, evolution, and partitioning of OA. Volatility distributions of ambient OA particles have often been measured, while viscosity measurements are scarce. We have previously developed a method to estimate the glass transition temperature (Tg) of an organic compound containing carbon, hydrogen, and oxygen. Based on analysis of over 2400 organic compounds including oxygenated organic compounds, as well as nitrogen- and sulfur-containing organic compounds, we extend this method to include nitrogen- and sulfur-containing compounds based on elemental composition. In addition, parameterizations are developed to predict Tg as a function of volatility and the atomic oxygen-to-carbon ratio based on a negative correlation between Tg and volatility. This prediction method of Tg is applied to ambient observations of volatility distributions at 11 field sites. The predicted Tg values of OA under dry conditions vary mainly from 290 to 339 K and the predicted viscosities are consistent with the results of ambient particle-phase-state measurements in the southeastern US and the Amazonian rain forest. Reducing the uncertainties in measured volatility distributions would improve predictions of viscosity, especially at low relative humidity. We also predict the Tg of OA components identified via positive matrix factorization of aerosol mass spectrometer (AMS) data. The predicted viscosity of oxidized OA is consistent with previously reported viscosity of secondary organic aerosols (SOA) derived from α-pinene, toluene, isoprene epoxydiol (IEPOX), and diesel fuel. Comparison of the predicted viscosity based on the observed volatility distributions with the viscosity simulated by a chemical transport model implies that missing low volatility compounds in a global model can lead to underestimation of OA viscosity at some sites. The relation between volatility and viscosity can be applied in the molecular corridor or volatility basis set approaches to improve OA simulations in chemical transport models by consideration of effects of particle viscosity in OA formation and evolution.

54 ENVIRONMENTAL SCIENCES↗

Standard operating procedures for the comprehensive and reliable analysis of cannabis terpenes

Terpenes are the primary determinants of cannabis flower aroma, and ongoing research tests their potential for impacting the overall experience. Frustratingly, despite the importance of terpenes in cannabis physiology and commercial uses, literature reports vary widely regarding the major constituents of volatile blends and the concentrations of individual terpenes. Here, in this article, we provide detailed descriptions of complementary approaches that will allow researchers to determine the identity and quantity of cannabis terpenes unequivocally and reliably. These standard operating procedures will guide decisions about which method to employ to address specific analytical goals. We are including two application examples to illustrate the utility of different approaches for tackling the analysis of terpenes in cannabis flower samples.

Polito, Joshua↗

Volatility in the lunar crust: Trace element analyses of lunar minerals by PIXE proton microprobe

In situ determination of mineral compositions using microbeam techniques can characterize magma compositions through mineral-melt partitioning, and be used to investigate fine-grained or rare phases which cannot be extracted for analysis. Abundances of Fe, Mn, Sr, Ga, Zr, Y, Nb, Zn, Cu, Ni, Se, and Sb were determined for various mineral phases in a small number of lunar highlands rocks using the PIXE proton microprobe. Sr/Ga ratios of plagioclase and Mn/Zn ratios of mafic silicates show that the ferroan anorthosites and Mg-suite cumulates are depleted in volatile lithophile elements to about the same degree compared with chondrites and the Earth. This links the entire lunar crust to common processes or source compositions. In contrast, secondary sulfides in Descartes breccia clasts are enriched in chalcophile elements such as Cu, Zn, Ni, Se, and Sb, and represent a potential resource in the lunar highlands.

Norman, M. D.↗