Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Status and Plans for an SRF Accelerator Test Facility at Fermilab

A superconducting RF accelerator test facility is currently under construction at Fermilab. The accelerator will consist of an electron gun, 40 MeV injector, beam acceleration section consisting of 3 TTF-type or ILC-type cryomodules, and multiple downstream beam lines for testing diagnostics and performing beam experiments. With 3 cryomodules installed this facility will initially be capable of generating an 810 MeV electron beam with ILC beam intensity. The facility can accommodate up to 6 cryomodules for a total beam energy of 1.5 GeV. This facility will be used to test SRF cryomodules under high intensity beam conditions, RF power equipment, instrumentation, and LLRF and controls systems for future SRF accelerators such as the ILC and Project-X. This paper describes the current status and overall plans for this facility.

43 PARTICLE ACCELERATORS↗

Electro-optical measurement of intense electric field on a high energy pulsed power accelerator

We describe a direct electro-optical approach to measuring a strong 118 MV/m narrow pulse width (~ 33 ns) electric field in the magnetically insulated transmission line (MITL) of a pulsed power accelerator. To date, this is the highest direct external electric field measured electro-optically in a pulsed power accelerator, and it is between two to three orders of magnitude higher than values reported in comparable high energy scientific experiments. The MITL electric field is one of the most important operating parameters in an accelerator and is critical to understanding the properties of the radiation output. However, accurately measuring these high fields using conventional pulsed power diagnostics is difficult due to the strength of interfering particles and fields. Our approach uses a free-space laser beam with a dielectric crystal sensor that is highly immune to electromagnetic interference and does not require an external calibration. Here we focus on device theory, operating parameters, laboratory and pulsed power accelerator experiments as well as challenges that were overcome in the measurement environment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Corona and solar wind

The Pinhole/Occulter Facility is a powerful tool for studying the physics of the extended corona and origins of the solar wind. Spectroscopic data acquired by the P/OF coronal instruments can greatly expand empirical information about temperatures, densities, flow velocities, magnetic fields, and chemical abundances in the corona out to r or approx. 10 solar radii. Such information is needed to provide tight empirical constraints on critical physical processes involved in the transport and dissipation of energy and momentum, the heating and acceleration of plasma, and the acceleration of energetic particles. Because of its high sensitivity, high spatial and temporal resolutions, and powerful capabilities for plasma diagnostics, P/OF can significantly increase our empirical knowledge about coronal streamers and transients and thereby advance the understanding of the physics of these phenomena. P/OF observations can be used to establish the role in solar wind generation, if any, of small-scale dynamical phenomena, such as spicules, macrospicules and coronal bullets, and the role of the fine-scale structures, such as polar plumes. Finally, simultaneous measurements by the P/OF coronal and hard X-ray instruments can provide critical empirical information concerning nonthermal energy releases and acceleration of energetic particles in the corona.

Withbroe, G. L.↗

Exploring cesium properties internal to the LANSCE H - ion source using resonant absorption spectroscopy

The Los Alamos Neutron Science Center (LANSCE) H - ion source has provided stable output for decades of LANL mission needs, but its maximum beam output has remained the same at ~15 mA. A roadblock to improving beam output has been a lack of thorough understanding of the internal mechanisms of LANSCE H - ion source. The LANSCE H - Ion Source Laser Diagnostic Stand (HLDS) was recently built and commissioned to explore these internal mechanisms using laser absorption techniques, to measure and diagnose dynamic H - and cesium densities. The cesium density probe is based on resonant absorption of a continuous wave diode laser tuned though the D 2 line of cesium (~852 nm). The diagnostic capabilities of HLDS will be reviewed, and measurements using the cesium laser diagnostic will be presented.

43 PARTICLE ACCELERATORS↗

Linear Accelerator-Based Intensity-Modulated Total Marrow Irradiation Technique for Treatment of Hematologic Malignancies: A Dosimetric Feasibility Study

Purpose: To investigate the dosimetric feasibility of linear accelerator-based intensity-modulated total marrow irradiation (IM-TMI) in patients with hematologic malignancies. Methods and Materials: Linear accelerator-based IM-TMI treatment planning was performed for 9 patients using the Eclipse treatment planning system. The planning target volume (PTV) consisted of all the bones in the body from the head to the mid-femur, except for the forearms and hands. Organs at risk (OAR) to be spared included the lungs, heart, liver, kidneys, brain, eyes, oral cavity, and bowel and were contoured by a physician on the axial computed tomography images. The three-isocenter technique previously developed by our group was used for treatment planning. We developed and used a common dose-volume objective method to reduce the planning time and planner subjectivity in the treatment planning process. Results: A 95% PTV coverage with the 99% of the prescribed dose of 12 Gy was achieved for all nine patients. The average dose reduction in OAR ranged from 19% for the lungs to 68% for the lenses. The common dose-volume objective method decreased the planning time by an average of 35% and reduced the inter- and intra- planner subjectivity. Conclusion: The results from the present study suggest that the linear accelerator-based IM-TMI technique is clinically feasible. We have demonstrated that linear accelerator-based IM-TMI plans with good PTV coverage and improved OAR sparing can be obtained within a clinically reasonable time using the common dose-volume objective method proposed in the present study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PHELIX

The Precision, High-Energy density, Liner Implosion Experiment (PHELIX) pulsed power driver is currently under development at Los Alamos National Laboratory. When operational PHELIX will provide 0.5-1.0 MJ of capacitively stored energy into cm size liners that will reach implosion velocities of 1-4 km/s with approximately 10-20 microsecond implosion time. Peak load currents will be in the 5-10 megaamp range. To do this the machine employs a reusable, multi-turn primary, single-turn secondary transformer to couple the 100-120 kV Marx capacitor system to the load. The transformer has been designed toward a coupling coefficient of 0.9. PHELIX is designed to be portable with only an 8 x 25 ft{sup 2} footprint. This will allow the machine to be taken to the experiment designer's diagnostic of choice. The first such diagnostic will be the LANL proton-radiography facility. There the multi-frame, high-resolution, imaging capability will be used to study hydrodynamic and material phenomena.

43 PARTICLE ACCELERATORS↗

Geant4 Simulations on Faraday Cup Design for PIP-II Laser Wire Scanner System

The Proton Improvement Plan-II (PIP-II) accelerator upgrade at Fermilab represents a groundbreaking leap forward in high-energy physics research. This ambitious initiative involves enhancing Fermilab's accelerator complexby replacing the current linear accelerator (linac) with awarm front end (WFE) capable of accelerating H- beamsup to 2.1 MeV. Subsequently, a superconducting linac further accelerates these beams up to 800 MeV. To preciselymeasure the transverse beam profile, a combination of traditional wire scanners at the WFE section and Laser wirescanners along the superconducting linac are planned forimplementation. This investigation is centered on refiningthe Faraday cup design for the PIP-II Laser wire scannersby utilizing GEANT4, a Monte Carlo simulation toolkit.Leveraging this method enables a comprehensive analysisof particle trajectories, energy deposition, secondary particle emission, backscattering, etc., facilitating optimizationthrough adjustments to cup geometries, materials, andplacement to maximize its efficacy in beam diagnostics.

43 PARTICLE ACCELERATORS↗

Low Speed Azimuthal Wave Characteristics In a Cathode Plume

A diagnostic technique to measure the azimuthally traveling m=1 mode in the plume of a cathode inside a HET-like magnetic field was developed. The data show the wave accelerating with the increasing magnetic field strength. While the azimuthal wave grows, the presence of a high frequency (>1MHz) instability appears. While the appearance of this wave and general characteristics were observed using this diagnostic technique, further full-thruster environment testing is needed to show the effects the HET beam has on these instabilities

space propulsion↗

A machine learning approach for particle accelerator errant beam prediction using spatial phase deviation

Particle accelerators are extremely complex systems that are expected to operate on high availability. Predicting impending failures only by utilizing data collected from diagnostic equipment already on board can help operators to avoid installing expensive sensors, unscheduled downtime and associated costs. For this purpose we explore the predictive power of Machine Learning algorithms to detect faulty beams prior to the failure. In this study, we propose a Machine Learning approach to model mapping from a pair of sensors located across the accelerator. While the model is trained to represent normal operation, we evaluate the predictive performance on known faulty beam pulses. We also investigate the model performance on unseen data through k-fold cross-validation. Then we recap the analysis with a neural architecture search and hyperparameter optimization study to fine tune our initial model. In conclusion, this paper will also introduce a sustainable framework that can standardize Machine Learning workflow applied to particle accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray power and yield measurements at the refurbished Z machine

Advancements have been made in the diagnostic techniques to measure accurately the total radiated x-ray yield and power from z-pinch implosion experiments at the Z machine with high accuracy. The Z machine is capable of outputting 2 MJ and 330 TW of x-ray yield and power, and accurately measuring these quantities is imperative. We will describe work over the past several years which include the development of new diagnostics, improvements to existing diagnostics, and implementation of automated data analysis routines. A set of experiments on the Z machine were conducted in which the load and machine configuration were held constant. During this shot series, it was observed that the total z-pinch x-ray emission power determined from the two common techniques for inferring the x-ray power, a Kimfol filtered x-ray diode diagnostic and the total power and energy diagnostic, gave 449 TW and 323 TW, respectively. Our analysis shows the latter to be the more accurate interpretation. More broadly, the comparison demonstrates the necessity to consider spectral response and field of view when inferring x-ray powers from z-pinch sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial retarding field energy analyzer measurements downstream of a helicon double layer plasma

Spatial ion energy measurements using a retarding field energy analyzer are performed in the exhaust of a 0.30 mTorr, 250 W helicon double layer plasma to investigate the divergence of the argon ion beam formed by acceleration in the double layer. Various divergence angles are computed by considering the radial distribution of beam density; the average beam ion diverging by 9 deg. The efficiency at which momentum is imparted parallel to the longitudinal axis of the thruster is calculated to be 98%. The results show that a few centimeters downstream of the source, the beam ions do not follow the magnetic field lines.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Systematic Study of Rayleigh-Taylor Growth in Directly Driven Plastic Targets in a Laser-Intensity Range from ~2 x 10^14 to ~1.5 x 10^15 W/cm^2

Direct-drive, Rayleigh–Taylor (RT) growth experiments were performed using planar plastic targets on the OMEGA Laser Facility [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)] at laser intensities between ~2 x 10^14 and ~1.5 x 10^15 W/cm^2. The primary purpose of the experiments was to test fundamental physics in hydrocodes at the range of drive intensities relevant to ignition designs. The target acceleration was measured with a streak camera using side-on, x-ray radiography, while RT growth was measured with a framing camera using face-on radiography. In a laser-intensity range from 2 to 5 x 10^14 W/cm^2, the measured RT growth agrees well with two-dimensional simulations, based on a local model of thermal-electron transport. The RT growth at drive intensities above ~1.0 x 10^15 W/cm^2 was strongly stabilized compared to the local model predictions. The experiments demonstrate that standard simulations, based on a local model of electron thermal transport, break down at peak intensities of ignition designs, although they work well at lower intensities. These results also imply that direct-drive ignition targets are significantly more stable than previously calculated using local electron-transport models at peak intensities of ignition designs. The preheating effects by nonlocal electron transport and hot electrons were identified as some of the stabilizing mechanisms.

Smalyuk, V A↗

X-ray phase-contrast imaging with an Inverse Compton Scattering source

Single-shot in-line phase-contrast imaging with the Inverse Compton Scattering X-ray source available at ATF (Accelerator Test Facility) at Brookhaven National Laboratory is experimentally demonstrated. Phase-contrast images of polymer wires are obtained with a single X-ray pulse whose time length is about 1 picosecond. The edge-enhancement effect is clearly visible in the images and simulations show a quantitative agreement with experimental data. A phase-retrieval step in the image processing leads to a accurate estimation of the projected thickness of our samples. Finally, a single-shot image of a wasp is presented as an example of a biological sample.

07 ISOTOPE AND RADIATION SOURCES↗

Artifacts in X-ray Dark-Field Tomography

Grating-based x-ray imaging provides three principle kinds of contrast: absorption, phase, and dark-field. Due to the availability of tomographic reconstruction algorithms for the dark-field contrast, it is now possible to take advantage of quantitative scatter information. However, the published algorithm is based on several assumptions that might be violated in reality. We use numerical simulations in order to identify artifacts in the reconstructions, which is crucial for the interpretation of experimental data.

07 ISOTOPE AND RADIATION SOURCES↗

New Nanoscale Imaging with a Simple Hard X-Ray Nanoslit

A simple and new procedure to measure the optimal intensity distribution of an x-ray wavefield in nanoscale resolution is proposed. A heavy-metal wire can work as a ''nanoslit'' with a nanoscale aperture size. Its basic function can be described simply with geometrical optics using total reflection. The further function is investigated with numerical calculation of a diffraction edge. In the experiment, Fresnel fringes generated by a rectangular aperture were measured by using a 300-{mu}m platinum wire as the nanoslit. Its high potential use in imaging applications is discussed.

07 ISOTOPE AND RADIATION SOURCES↗