Search NASA⌕ Search

SEARCH · Search NASA

Results for “biomedical data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

SU-F-R-33: Can CT and CBCT Be Used Simultaneously for Radiomics Analysis

Purpose: To investigate whether CBCT and CT can be used in radiomics analysis simultaneously. To establish a batch correction method for radiomics in two similar image modalities. Methods: Four sites including rectum, bladder, femoral head and lung were considered as region of interest (ROI) in this study. For each site, 10 treatment planning CT images were collected. And 10 CBCT images which came from same site of same patient were acquired at first radiotherapy fraction. 253 radiomics features, which were selected by our test-retest study at rectum cancer CT (ICC>0.8), were calculated for both CBCT and CT images in MATLAB. Simple scaling (z-score) and nonlinear correction methods were applied to the CBCT radiomics features. The Pearson Correlation Coefficient was calculated to analyze the correlation between radiomics features of CT and CBCT images before and after correction. Cluster analysis of mixed data (for each site, 5 CT and 5 CBCT data are randomly selected) was implemented to validate the feasibility to merge radiomics data from CBCT and CT. The consistency of clustering result and site grouping was verified by a chi-square test for different datasets respectively. Results: For simple scaling, 234 of the 253 features have correlation coefficient ρ>0.8 among which 154 features haveρ>0.9 . For radiomics data after nonlinear correction, 240 of the 253 features have ρ>0.8 among which 220 features have ρ>0.9. Cluster analysis of mixed data shows that data of four sites was almost precisely separated for simple scaling(p=1.29 * 10{sup −7}, χ{sup 2} test) and nonlinear correction (p=5.98 * 10{sup −7}, χ{sup 2} test), which is similar to the cluster result of CT data (p=4.52 * 10{sup −8}, χ{sup 2} test). Conclusion: Radiomics data from CBCT can be merged with those from CT by simple scaling or nonlinear correction for radiomics analysis.

60 APPLIED LIFE SCIENCES↗

MO-DE-206-00: Joint AAPM-WMIS Symposium: Metabolic Imaging of Cancer

In this symposium jointly sponsored by the World Molecular Imaging Society (WMIS) and the AAPM, luminary speakers on imaging metabolism will discuss three impactful topics. The first presentation on Cellular Metabolism of FDG will be given by Guillem Pratx (Stanford). This presentation will detail new work on looking at how the most common molecular imaging agent, fluoro-deoxy-glucose is metabolized at a cellular level. This will be followed by a talk on an improved approach to whole-body PET imaging by Simon Cherry (UC Davis). Simon’s work on a new whole-body PET imaging system promises to have dramatic improvement in our ability to detect and characterize cancer using PET. Finally, Jim Bankson (MD Anderson) will discuss extremely sophisticated approaches to quantifying hyperpolarized-13-C pyruvate metabolism using MR imaging. This technology promises to compliment the exquisite sensitivity of PET with an ability to measure not just uptake, but tumor metabolism. Learning Objectives: Understand the metabolism of FDG at a cellular level. Appreciate the engineering related to a novel new high-sensitivity whole-body PET imaging system. Understand the process of hyperpolarization, how pyruvate relates to metabolism and how advanced modeling can be used to better quantify this data. G. Pratx, Funding: 5R01CA186275, 1R21CA193001, and Damon Runyon Cancer Foundation. S. Cherry, National Institutes of Health; University of California, Davis; Siemens Medical SolutionsJ. Bankson, GE Healthcare; NCI P30-CA016672; CPRIT PR140021-P5.

60 APPLIED LIFE SCIENCES↗

Verifying the reciprocity of interparticle interaction forces in strongly coupled systems

We propose a simple criterion for revealing the breaking of pair interaction symmetry in strongly coupled dissipative systems. The criterion is based on the analysis of correlations between the velocities of strongly interacting particles, which can be measured relatively easily in experiments with macroparticles in various media. We derive analytic relations that make it possible to calculate the derivatives of the interaction force between a pair of particles from the data on the correlations of their velocities and coordinates. The proposed criterion and relations are verified using the results of numerical simulation of the dynamics of dust particles in a plasma.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-Resolution Scanning Coded-Mask-Based X-ray Multi-Contrast Imaging and Tomography

Near-field X-ray speckle tracking has been used in phase-contrast imaging and tomography as an emerging technique, providing higher contrast images than traditional absorption radiography. Most reported methods use sandpaper or membrane filters as speckle generators and digital image cross-correlation for phase reconstruction, which has either limited resolution or requires a large number of position scanning steps. Recently, we have proposed a novel coded-mask-based multi-contrast imaging (CMMI) technique for single-shot measurement with superior performance in efficiency and resolution compared with other single-shot methods. We present here a scanning CMMI method for the ultimate imaging resolution and phase sensitivity by using a coded mask as a high-contrast speckle generator, the flexible scanning mode, the adaption of advanced maximum-likelihood optimization to scanning data, and the multi-resolution analysis. Scanning CMMI can outperform other speckle-based imaging methods, such as X-ray speckle vector tracking, providing higher quality absorption, phase, and dark-field images with fewer scanning steps. Scanning CMMI is also successfully demonstrated in multi-contrast tomography, showing great potentials in high-resolution full-field imaging applications, such as in vivo biomedical imaging.

Qiao, Zhi (ORCID:0000000233928732)↗

Primate-specific miRNA-637 inhibited tumorigenesis in human pancreatic ductal adenocarcinoma cells by suppressing Akt1 expression

Highlights: • miR-637 acted as a tumor suppressor in pancreatic cancer. • Akt1 was a real target of miR-637 in pancreatic ductal adenocarcinoma (PDAC) cells. • Akt1 knockdown induced the cell growth inhibition and apoptosis in PDAC cells. As a primate-specific microRNA, miR-637 has been discovered for nearly 10 years. Our previous study demonstrated that miR-637 acted as a suppressor in hepatocellular carcinoma. However, its biomedical significance in pancreatic cancer remains obscure. In the present study, miR-637 was found to be significantly downregulated in pancreatic ductal adenocarcinoma (PDAC) cell lines and most of the PDAC specimens. Furthermore, the enforced overexpression of miR-637 dramatically inhibited cell proliferation and induced apoptosis of PDAC cells. Akt1, as a serine/threonine-protein kinase, has been identified as an oncogene in multiple cancers including pancreatic cancer. Our data confirmed that Akt1 was a novel target for miR-637, and its knockdown also induced cell growth inhibition and apoptosis in PDAC cells. In conclusion, our data indicated that miR-637 acted as a tumor-suppressor in PDAC, and the suppressive effect was mediated, at least partially, by suppressing Akt1 expression.

60 APPLIED LIFE SCIENCES↗

Middle Kittanning Coal Waste and Underclay as an Alternative Rare Earth Elements Feedstock

In order to secure domestic sources of rare earth elements (REE) from coal related materials, there must be validation of representative feedstocks. Actively producing coal mines that target the Middle Kittanning coal seam in the Appalachian Basin were compiled. These mines were cross-referenced with publicly available geochemical data such as the U.S. Geological Survey (USGS) Earth Mapping Resources Initiative geochemical data along with samples evaluated and characterized by the National Energy Technology Laboratory (NETL). This work evaluated the extent of elevated Middle Kittanning underclay concentrations of REE in comparison to other underclay formations. Therefore, further up-scaling of research associated with the separation and extraction of REE and other critical minerals can be beneficial to utilizing domestic REE supplies for various technology sectors, to include energy, biomedical, and defense. Numerous current active mines targeting the Middle Kittanning coal seam represent a geographically significant opportunity for shared feedstocks and collaborations to further understand the role of Middle Kittanning underclay as a critical mineral feedstock.

01 COAL, LIGNITE, AND PEAT↗

Life sciences payload definition and integration study. Volume 1: Management summary

The objectives of a study program to determine the life sciences payloads required for conducting biomedical experiments during space missions are presented. The objectives are defined as: (1) to identify the research functions which must be performed aboard life sciences spacecraft laboratories and the equipment needed to support these functions and (2) to develop layouts and preliminary conceptual designs of several potential baseline payloads for the accomplishment of life research in space. Payload configurations and subsystems are described and illustrated. Tables of data are included to identify the material requirements for the space missions.

Source record↗

Life sciences payload definition and integration study. Volume 2: Requirements, design, and planning studies for the carry-on laboratories

The task phase concerned with the requirements, design, and planning studies for the carry-on laboratory (COL) began with a definition of biomedical research areas and candidate research equipment, and then went on to develop conceptual layouts for COL which were each evaluated in order to arrive at a final conceptual design. Each step in this design/evaluation process concerned itself with man/systems integration research and hardware, and life support and protective systems research and equipment selection. COL integration studies were also conducted and include attention to electrical power and data management requirements, operational considerations, and shuttle/Spacelab interface specifications. A COL program schedule was compiled, and a cost analysis was finalized which takes into account work breakdown, annual funding, and cost reduction guidelines.

Source record↗

Photonic Integrated Circuit (PIC) Device Structures: Background, Fabrication Ecosystem, Relevance to Space Systems Applications, and Discussion of Related Radiation Effects

Electronic integrated circuits are considered one of the most significant technological advances of the 20th century, with demonstrated impact in their ability to incorporate successively higher numbers transistors and construct electronic devices onto a single CMOS chip. Photonic integrated circuits (PICs) exist as the optical analog to integrated circuits; however, in place of transistors, PICs consist of numerous scaled optical components, including such "building-block" structures as waveguides, MMIs, lasers, and optical ring resonators. The ability to construct electronic and photonic components on a single microsystems platform offers transformative potential for the development of technologies in fields including communications, biomedical device development, autonomous navigation, and chemical and atmospheric sensing. Developing on-chip systems that provide new avenues for integration and replacement of bulk optical and electro-optic components also reduces size, weight, power and cost (SWaP-C) limitations, which are important in the selection of instrumentation for specific flight projects. The number of applications currently emerging for complex photonics systems-particularly in data communications-warrants additional investigations when considering reliability for space systems development. This Body of Knowledge document seeks to provide an overview of existing integrated photonics architectures; the current state of design, development, and fabrication ecosystems in the United States and Europe; and potential space applications, with emphasis given to associated radiation effects and reliability.

Body of Knowledge (BOK)↗

Investigating Biological Responses to Deep Space Radiation for Missions Beyond Low Earth Orbit (LEO) using Yeast

To enable long-term spaceflight missions and establish habitation on the Moon and Mars, we require a comprehensive understanding of the effects of chronic deep space radiation exposure on humans. BioSentinel is NASA’s first biological CubeSat to venture beyond Low Earth Orbit (LEO). It utilizes Saccharomyces cerevisiae (budding yeast) as a model organism to study biological responses to deep space radiation. Yeast share significant genetic homology with humans, including basic cellular metabolism and DNA repair mechanisms. In addition, unlike human cell cultures, yeast can survive the duration and constraints of a deep space mission. BioSentinel measures biological responses using an optical system and alamarBlue oxidation-reduction (redox) dye. Two strains of yeast are studied - a wild-type and a rad51 mutant strain that is deficient in DNA repair. Changes in metabolism and growth are monitored throughout the nominal 6-month mission. Preliminary tests indicate a significant change in the alamarBlue response to low-dose ionizing radiation (IR). Additionally, rad51 cells have shown an IR dose-dependent decrease in glucose uptake and accumulation of oxidized NADH (NAD+). These biomolecules are involved in reactions responsible for basic cell processes, including growth and development, signaling, and respiration. The current study expanded upon previous data by exposing yeast to deep space-relevant radiation. Glucose and NADH/NAD+ assays were conducted on yeast subjected to varying dosages of high-energy Fe-56 and simulated galactic cosmic rays (GCRs). The resulting data was analyzed using Excel and GraphPad Prism. A particular focus was to identify biomolecules resulting from aerobic respiration, which requires the presence of oxygen, or anaerobic processes. As long-term spaceflight missions draw near, it is increasingly important to characterize biological processes affected by the conditions of deep space. Studying biomolecular damage caused by deep space radiation may enable the development of engineering controls or biomedical therapeutics that mitigate health complications for future astronauts.

Kyra Keenan↗

Variation and Control of Process Behavior

The purpose of this work was to highlight the importance of controlling process variability for successful quality assurance (QA). We describe the method of statistical process control for characterizing and controlling a process. Traditionally, QA has been performed by comparing some important measurement (e.g., linear accelerator output) against a corresponding specification. Although useful in determining the fitness of a particular measurement, this approach does not provide information about the underlying process behavior over time. A modern view of QA is to consider the time-ordered behavior of a process. Every process displays characteristic behaviors that are independent of the specifications imposed on it. The goal of modern QA is, not only to ensure that a process is on-target, but that it is also operating with minimal variation. This is accomplished by way of a data-driven approach using process behavior charts. The development of process behavior charts, historically known as control charts, and process behavior (action) limits are described. The effect these concepts have on quality management is also discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of scatter in digital mammography from use of Monte Carlo simulations and comparison to physical measurements

Purpose: Monte Carlo simulations were performed with the goal of verifying previously published physical measurements characterizing scatter as a function of apparent thickness. A secondary goal was to provide a way of determining what effect tissue glandularity might have on the scatter characteristics of breast tissue. The overall reason for characterizing mammography scatter in this research is the application of these data to an image processing-based scatter-correction program. Methods: MCNPX was used to simulate scatter from an infinitesimal pencil beam using typical mammography geometries and techniques. The spreading of the pencil beam was characterized by two parameters: mean radial extent (MRE) and scatter fraction (SF). The SF and MRE were found as functions of target, filter, tube potential, phantom thickness, and the presence or absence of a grid. The SF was determined by separating scatter and primary by the angle of incidence on the detector, then finding the ratio of the measured scatter to the total number of detected events. The accuracy of the MRE was determined by placing ring-shaped tallies around the impulse and fitting those data to the point-spread function (PSF) equation using the value for MRE derived from the physical measurements. The goodness-of-fit was determined for each data set as a means of assessing the accuracy of the physical MRE data. The effect of breast glandularity on the SF, MRE, and apparent tissue thickness was also considered for a limited number of techniques. Results: The agreement between the physical measurements and the results of the Monte Carlo simulations was assessed. With a grid, the SFs ranged from 0.065 to 0.089, with absolute differences between the measured and simulated SFs averaging 0.02. Without a grid, the range was 0.28–0.51, with absolute differences averaging −0.01. The goodness-of-fit values comparing the Monte Carlo data to the PSF from the physical measurements ranged from 0.96 to 1.00 with a grid and 0.65 to 0.86 without a grid. Analysis of the data suggested that the nongrid data could be better described by a biexponential function than the single exponential used here. The simulations assessing the effect of breast composition on SF and MRE showed only a slight impact on these quantities. When compared to a mix of 50% glandular/50% adipose tissue, the impact of substituting adipose or glandular breast compositions on the apparent thickness of the tissue was about 5%. Conclusions: The findings show agreement between the physical measurements published previously and the Monte Carlo simulations presented here; the resulting data can therefore be used more confidently for an application such as image processing-based scatter correction. The findings also suggest that breast composition does not have a major impact on the scatter characteristics of breast tissue. Application of the scatter data to the development of a scatter-correction software program can be simplified by ignoring the variations in density among breast tissues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-211: Assessing the Consistency of the ViewRay 0.35 T MRI System

Purpose: ViewRay is a novel image-guided radiotherapy approach with an integrated 0.35 T MR unit and three Cobalt-60 heads. In order to continuously ensure the high resolution and high soft tissue contrast available in MR images, we quantified a multitude of relevant imaging parameters over a period of six months to establish its stability and imaging quality. In the assessment process, consideration is also given to the need to establish the number of tests required to have confidence in the performance of the system for radiation therapy planning applications. Methods: Daily, weekly, monthly and annual imaging tests were performed over a period of six months using standardized phantoms (a 24 cm diameter sphere and the ACR phantom) to quantify the performance of the system. In addition to the ACR and NEMA recommended tests, we also included element testing, spatial integrity, Eddy current and magnetic field inhomogeneity measurements. The ACR test is used for assessing the following parameters for T1 and T2: geometric accuracy, high contrast spatial resolution, slice thickness accuracy, slice position accuracy, percent signal ghosting, low contrast object detectability. It also includes percent image uniformity (PIU) for T1. The NEMA test is primarily designed to check SNR and PIU. Results: Over the period of six months, all the parameters were maintained within the recommendations provided in the ACR and NEMA standards. PIU and SNR were found to be sensitive to malfunctions in the components of the multileaf collimators. Details of the findings will be presented. Conclusion: The data suggests that ViewRay imaging system has functioned in a consistent and reliable manner. MR imaging from ViewRay 0.35T system complies with the ACR and NEMA recommended acceptance standards.

60 APPLIED LIFE SCIENCES↗

Large area CMOS active pixel sensor x-ray imager for digital breast tomosynthesis: Analysis, modeling, and characterization

Purpose: Large area x-ray imagers based on complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) technology have been proposed for various medical imaging applications including digital breast tomosynthesis (DBT). The low electronic noise (50–300 e{sup −}) of CMOS APS x-ray imagers provides a possible route to shrink the pixel pitch to smaller than 75 μm for microcalcification detection and possible reduction of the DBT mean glandular dose (MGD). Methods: In this study, imaging performance of a large area (29 × 23 cm{sup 2}) CMOS APS x-ray imager [Dexela 2923 MAM (PerkinElmer, London)] with a pixel pitch of 75 μm was characterized and modeled. The authors developed a cascaded system model for CMOS APS x-ray imagers using both a broadband x-ray radiation and monochromatic synchrotron radiation. The experimental data including modulation transfer function, noise power spectrum, and detective quantum efficiency (DQE) were theoretically described using the proposed cascaded system model with satisfactory consistency to experimental results. Both high full well and low full well (LFW) modes of the Dexela 2923 MAM CMOS APS x-ray imager were characterized and modeled. The cascaded system analysis results were further used to extract the contrast-to-noise ratio (CNR) for microcalcifications with sizes of 165–400 μm at various MGDs. The impact of electronic noise on CNR was also evaluated. Results: The LFW mode shows better DQE at low air kerma (K{sub a} < 10 μGy) and should be used for DBT. At current DBT applications, air kerma (K{sub a} ∼ 10 μGy, broadband radiation of 28 kVp), DQE of more than 0.7 and ∼0.3 was achieved using the LFW mode at spatial frequency of 0.5 line pairs per millimeter (lp/mm) and Nyquist frequency ∼6.7 lp/mm, respectively. It is shown that microcalcifications of 165–400 μm in size can be resolved using a MGD range of 0.3–1 mGy, respectively. In comparison to a General Electric GEN2 prototype DBT system (at MGD of 2.5 mGy), an increased CNR (by ∼10) for microcalcifications was observed using the Dexela 2923 MAM CMOS APS x-ray imager at a lower MGD (2.0 mGy). Conclusions: The Dexela 2923 MAM CMOS APS x-ray imager is capable to achieve a high imaging performance at spatial frequencies up to 6.7 lp/mm. Microcalcifications of 165 μm are distinguishable based on reported data and their modeling results due to the small pixel pitch of 75 μm. At the same time, potential dose reduction is expected using the studied CMOS APS x-ray imager.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-IeP1-03: Establishment of Provincial Diagnostic Reference Levels in Pediatric Imaging

Purpose: To establish provincial diagnostic reference levels (DRLs) in pediatric general radiography and computed tomography (CT) as a tool for the optimization of exposure parameters. Methods: Patient dose survey was conducted in the only pediatric hospital in the province of Nova Scotia. The DRLs were established as the 75th percentile of patient dose distributions in different age groups. For routine radiography projections the DRLs were determined in terms of entrance surface dose (ESD) calculated from the radiation output measurements and the tube current-exposure time product (mAs) recorded for each examination. Patient thickness was measured by the technologist during the examination. The CR and DR systems, employing respectively a fixed technique and phototiming, were evaluated separately; a two-tailed Student’s t-test was used to determine the significance of differences between the means of dose distributions. The CT studies included routine head, chest, abdomen/pelvis, and chest/abdomen/pelvis. The volume CT dose index (CTDIvol) and dose-length product (DLP) values were extracted retrospectively from PACS. The correction factors based on the effective diameter of the patient were applied to the CT dosimetry metrics based on the standard phantoms. Results: The provincial DRLs were established in the following age groups: newborn, 1, 5, 10, and 15 year olds. In general radiography the DR systems demonstrated slightly lower dose than the CR for all views, however the differences were not statistically significant (p > 0.05) for all examinations. In CT the provincial DRLs were lower than the published data, except for head DLPs in all age categories. This might be due to the small patient sample size in the survey. Future work will include additional CT data collection over an extended period of time. Conclusion: Provincial DRLs were established in the dedicated children’s hospital to provide guidance for the other facilities in examinations of pediatric patients.

60 APPLIED LIFE SCIENCES↗

Perspectives on Machine Learning-assisted Plasma Medicine: Towards Automated Plasma Treatment

Cold atmospheric plasmas (CAPs) have shown great promise for medical applications through their synergistic chemical, electrical, and thermal effects, which can induce therapeutic outcomes. However, safe and reproducible plasma treatment of complex biological surfaces poses a major hurdle to the widespread adoption of CAPs for medical applications. Predictive modeling of the mutual interactions between the plasma and biological surfaces and, thus, systematic approaches to quantify and predict plasma treatment outcomes remain largely elusive due to the lack of mechanistic understanding of plasma-surface interactions that can span across vastly different length-and time-scales. In addition, real-time sensing capabilities in biomedical CAP devices are often limited, which can be detrimental to plasma treatment due to the intrinsic plasma and surface variability during the treatment, as well as sensitivity to external perturbations. All of these challenges can make reproducible and effective plasma treatment of biological surfaces difficult to realize, which is further compounded by errors due to human operation of hand-held CAP devices. Machine learning and data-driven approaches can be particularly useful in addressing these challenges in three major ways: (i) data-driven modeling of hard-to-model plasma-surface interactions and plasma treatment outcomes; (ii) learning data analytics for plasma and surface diagnostics in real-time; and (iii) developing predictive controllers that enable reliable and effective CAP treatments. Furthermore, this paper discusses the promise of machine learning to accelerate plasma medicine research in these areas, toward machine learning-assisted and automated CAP treatment of complex biological surfaces.

60 APPLIED LIFE SCIENCES↗

The voltage-gated proton channel Hv1 is expressed in pancreatic islet β-cells and regulates insulin secretion

The voltage-gated proton channel Hv1 is a potent acid extruder that participates in the extrusion of the intracellular acid. Here, we showed for the first time, Hv1 is highly expressed in mouse and human pancreatic islet β-cells, as well as β-cell lines. Imaging studies demonstrated that Hv1 resides in insulin-containing granules in β-cells. Knockdown of Hv1 with RNA interference significantly reduces glucose- and K{sup +}-induced insulin secretion in isolated islets and INS-1 (832/13) β-cells and has an impairment on glucose- and K{sup +}-induced intracellular Ca{sup 2+} homeostasis. Our data demonstrated that the expression of Hv1 in pancreatic islet β-cells regulates insulin secretion through regulating Ca{sup 2+} homeostasis.

60 APPLIED LIFE SCIENCES↗

Radiopharmaceuticals for SPECT cancer detection

The purpose of the study was to assess the efficacy of single photon emission computed tomography (SPECT) with {sup 199}Tl and {sup 99}mTc-MIBI in the detection of breast, laryngeal and hypopharyngeal cancers. A total of 220 patients were included into the study: 120 patients with breast lesions (100 patients with breast cancer and 20 patients with benign breast tumors) and 100 patients with laryngeal/hypopharyngeal diseases (80 patients with laryngeal/hypopharyngeal cancer and 20 patients with benign laryngeal/hypopharyngeal lesions). No abnormal {sup 199}Tl uptake was seen in all patients with benign breast and laryngeal lesions, indicating a 100% specificity of {sup 199}Tl SPECT. In the breast cancer patients, the increased {sup 199}Tl uptake in the breast was visualized in 94.8% patients, {sup 99m}Tc-MIBI—in 93.4% patients. The increased {sup 199}Tl uptake in axillary lymph nodes was detected in 60% patients, and {sup 99m}Tc-MIBI—in 93.1% patients. In patients with laryngeal/hypopharyngeal cancer, the sensitivity of SPECT with {sup 199}Tl and {sup 99m}Tc-MIBI was 95%. The {sup 199}Tl SPECT sensitivity in identification of regional lymph node metastases in the patients with laryngeal/hypopharyngeal cancer was 75% and the {sup 99m}Tc-MIBI SPECT sensitivity was 17%. The data obtained showed that SPECT with {sup 199}Tl and {sup 99m}Tc-MIBI can be used as one of the additional imaging methods in detection of tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗