Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Uncertainty Analysis of the CE-22 Advanced Nozzle Test Facility

This paper presents methods and results of a detailed measurement uncertainty analysis that was performed for the Advanced Nozzle Test Facility, CE-22, located at the NASA Glenn Research Center. Results for the uncertainty in thrust and flow coefficients, in addition to other variables of interest, are provided. Results are presented separately as random uncertainty (characterizing errors inherent to instrument or measurement environment, impacting repeatability), systematic uncertainty (capturing inaccuracies due to measurement process, calibration, installation effects or other sources which may introduce bias), and total combined uncertainty. The statistical methods and engineering judgments used to estimate elemental uncertainties are described. The analysis tool MANTUS (Measurement Analysis Tool for Uncertainty in Systems) was used to quantify instrumentation system uncertainty, and statistical analysis and engineering judgment were used to quantify other random and systematic uncertainty sources. The Monte Carlo method was used to propagate systematic and random elemental uncertainties to determine the uncertainties of various calculated variables of interest.

data quality↗

Operation of a H4RG-10 in the NASA Goddard Astrophyiscs Divison IR Detector Lab Testbed

Future space and ground based missions in the near infrared are planning to or will utilize the next generation of Teledyne's HxRG detectors, the HgCdTe 4K x 4K array (H4RG). The science cases of such missions will require optimal stability and noise performance. To assess the detailed performance of the H4RG, we have developed a small single detector testbed in NASA Goddard's Astrophysics Division IR detector lab. The testbed operates a H4RG array inside a large dewar using a room temperature Leach controller. The dewar will include two integrating spheres with controlled apertures using NIR LEDs as light sources as well as a calibrated photodiode to precisely measure flux. We present preliminary results of a banded H4RG-10 array on the bench. In the near future, we plan to use the test bed to investigate the specific origins of electronic noise in the test bed, persistence, and other flux dependent nonlinearities.

Mosby, Gregory↗

Determination of the solar angular dependence of the NOAA-20 VIIRS solar diffuser BRDF change factor

When fully illuminated by the Sun, the solar diffuser (SD) onboard of the NOAA-20 Visible Infrared Imaging Radiometer Suite (VIIRS) instrument provides a radiance source to allow for radiometric calibration of the VIIRS’s reflective solar bands (RSBs). Once on-orbit, due to solar bombardment and the space environment, the SD’s bidirectional reflectance distribution function (BRDF) changes its value. The change is denoted by a factor, known as the H-factor, that is time and wavelength dependent, as well as both incident and out-going angle dependent. Here, we use regular on-orbit solar diffuser stability monitor (SDSM) data to determine the solar angular dependence for the H-factor along the SD-to-SDSM direction. We compare the dependence with that for the VIIRS on the Suomi National Polar-orbiting Partnership satellite and apply the dependence ratio to obtain the N20 VIIRS SD H-factor along the SD-telescope direction.

N20 VIIRS↗

Efficiency calibration of the DSS 13 34-meter diameter beam waveguide antenna at 8.45 and 32 GHz

Efficiency measurements at 8.45 and 32 GHz (X and Ka bands, respectively) were carried out on the new 34 m diameter beam waveguide antenna now in use at the NASA Goldstone Deep Space Communications Complex. The use of portable test packages enabled measurements at both the Cassegrain and beam waveguide focal points. Radio sources (quasars and Venus) were used as calibrators, and updated determinations of flux and source size correction were made during the period of the measurements. Gain and efficiency determinations as a function of elevation angle are presented, and the effects of the beam waveguide system and antenna structure are clearly seen. At the beam waveguide focus, an 8.45 GHz peak efficiency of 72.38 pct. was measured; at 32 GHz, 44.89 pct. was measured.

Slobin, S. D.↗

Efficiency measurement techniques for calibration of a prototype 34-meter-diameter beam-waveguide antenna at 8.45 and 32 GHz

Efficiency measurements at 8.45 and 32 GHz (X and Ka bands, respectively) were carried out on the new 34 m diameter beam waveguide antenna now in use at the NASA Goldstone Deep Space Communications Complex. The use of portable test packages enabled measurements at both the Cassegrain and beam waveguide focal points. Radio sources (quasars and Venus) were used as calibrators, and updated determinations of flux and source size correction were made during the period of the measurements. Gain and efficiency determinations as a function of elevation angle are presented, and the effects of the beam waveguide system and antenna structure are clearly seen. At the beam waveguide focus, an 8.45 GHz peak efficiency of 72.38 pct was measured; at 32 GHz, 44.89 pct was measured.

Slobin, Stephen D.↗

SeaWiFS Postlaunch Technical Report Series: The Fifth Sea-WiFS Intercalibration Round-Robin Experiment (SIRREX-5), July 1996 - Volume 7

This report documents the fifth Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Intercalibration Round-Robin Experiment (SIRREX-5), which was held at the National Institute of Standards and Technology (NIST) on 23-30 July 1996. The agenda for SIRREX-5 was established based on recommendations made during SIRREX-4. For the first time in a SIRREX activity, instrument intercomparisons were performed at field sites, which were near NIST. The goals of SIRREX-5 were to continue the emphasis on training and the implementation of standard measurement practices, investigate the calibration methods and measurement chains in use by the oceanographic community, provide opportunities for discussion, and intercompare selected instruments. As at SIRREX-4, the day was divided between morning lectures and afternoon laboratory exercises. A set of core laboratory sessions were performed: 1) in-water radiant flux measurements; 2) in-air radiant flux measurements; 3) spectral radiance responsivity measurements using the plaque method; 4) device calibration or stability monitoring with portable field sources; and 5) various ancillary exercises designed to illustrate radiometric concepts. Before, during, and after SIRREX-5, NIST calibrated the SIRREX-5 participating radiometers for radiance and irradiance responsivity. The Facility for Automated Spectroradiometric Calibrations (FASCAL) was scheduled for spectral irradiance calibrations for standard lamps during SIRREX-5. Three lamps from the SeaWiFS community were submitted and two were calibrated.

Hooker, Stanford B.↗

(abstract) Absolute Flux Calibrations of Venus and Jupiter at 32 GHz

The microwave flux densities of Venus and Jupiter at 32 GHz have been measured using a calibration standard radio telescope system at the Owens Valley Radio Observatory (OVRO) during April and May of 1993. These measurements are part of a joint JPL/Caltech program to accurately calibrate a catalog of other radio sources using the two bright planets as flux standards.

microwave flux densities Venus Jupiter catalog cal↗

Coronal Physics and the Chandra Emission Line Project

With the launch of the Chandra X-ray Observatory, high resolution X-ray spectroscopy of cosmic sources has begun. Early, deep observations of three stellar coronal sources will provide not only invaluable calibration data, but will also give us benchmarks for plasma spectral modeling codes. These codes are to interpret data from stellar coronae, galaxies and clusters of galaxies. supernova remnants and other astrophysical sources, but they have been called into question in recent years as problems with understanding moderate resolution ASCA and EUVE data have arisen. The Emission Line Project is a collaborative effort to improve the models, with Phase 1 being the comparison of models with observed spectra of Capella, Procyon, and HR, 1099. Goals of these comparisons are (1) to determine and verify accurate and robust diagnostics and (2) to identify and prioritize issues in fundamental spectroscopy which will require further theoretical and/or laboratory work. A critical issue in exploiting the coronal data for these purposes is to understand the extent to which common simplifying assumptions (coronal equilibrium, time-independence, negligible optical depth) apply. We will discuss recent advances in our understanding of stellar coronae in this context.

Brickhouse, Nancy↗

One Galaxy Sample to Rule Them All: Halo Occupation Distribution Modeling of DES Year 3 Source Galaxies

Abstract For the joint analysis of second-order weak-lensing and galaxy clustering statistics, so-called 3 × 2 analyses, the selection and characterization of optimal galaxy samples is a major area of research. One promising choice is to use the same galaxy sample as lenses and sources, which reduces the systematics parameter space that describes the uncertainties related to galaxy samples. Such a “lens-equal-source” analysis significantly improves the self-calibration of photo- z systematics, leading to improved cosmological constraints. With the aim of enabling a lens-equal-source analysis on small scales, we investigate the halo–galaxy connection of DES Year 3 source galaxies. We develop a technique to construct mock source galaxy populations by matching COSMOS/UltraVISTA photometry to U niverse M achine galaxies. These mocks predict a source halo occupation distribution (HOD) that exhibits significant redshift evolution, nontrivial central incompleteness, and galaxy assembly bias. We produce multiple realizations of mock source galaxies drawn from the U niverse M achine posterior, with added uncertainties in the measured Dark Energy Survey photometry and galaxy shapes. We fit a modified HOD formalism to these realizations to produce priors on the galaxy–halo connection for cosmological analyses. We additionally train an emulator that predicts this HOD to ∼2% accuracy from redshift z = 0.1−1.3 that models the dependence of this HOD on (1) observational uncertainties in galaxy size and photometry and (2) uncertainties in the U niverse M achine predictions.

Salcedo, Andrés N. (ORCID:000000031420527X)↗

An Evaluation of Antarctica as a Calibration Target for Passive Microwave Satellite Missions with Climate Data Record Applications

Passive microwave remote sensing at L-band (1.4 GHz) is sensitive to soil moisture and sea surface salinity, both important climate variables. Science studies involving these variables can now take advantage of new satellite L-band observations. The first mission with regular global passive microwave observations at L-band is the European Space Agency's Soil Moisture and Ocean Salinity (SMOS), launched November, 2009. A second mission, NASA's Aquarius, was launched June, 201 I. A third mission, NASA's Soil Moisture Active Passive (SMAP) is scheduled to launch in 2014. Together, these three missions may provide a decade-long data record-provided that they are intercalibrated. The intercalibration is best performed at the radiance (brightness temperature) level, and Antarctica is proving to be a key calibration target. However, Antarctica has thus far not been fully characterized as a potential target. This paper will present evaluations of Antarctica as a microwave calibration target for the above satellite missions. Preliminary analyses have identified likely target areas, such as the vicinity of Dome-C and larger areas within East Antarctica. Physical sources of temporal and spatial variability of polar firn are key to assessing calibration uncertainty. These sources include spatial variability of accumulation rate, compaction, surface characteristics (dunes, micro-topography), wind patterns, and vertical profiles of density and temperature. Using primarily SMOS data, variability is being empirically characterized and attempts are being made to attribute observed variability to physical sources. One expected outcome of these studies is the potential discovery of techniques for remotely sensing--over all of Antarctica-parameters such as surface temperature.

Kim, Edward↗

An Evaluation of Antarctica as a Calibration Target for Passive Microwave Satellite Missions

Passive microwave remote sensing at L-band (1.4 GHz) is sensitive to soil moisture and sea surface salinity, both important climate variables. Science studies involving these variables can now take advantage of new satellite L-band observations. The first mission with regular global passive microwave observations at L-band is the European Space Agency's Soil Moisture and Ocean Salinity (SMOS), launched November, 2009. A second mission, NASA's Aquarius, was launched June, 201l. A third mission, NASA's Soil Moisture Active Passive (SMAP) is scheduled to launch in 2014. Together, these three missions may provide a decade-long data record -- provided that they are intercalibrated. The intercalibration is best performed at the radiance (brightness temperature) level, and Antarctica is proving to be a key calibration target. However, Antarctica has thus far not been fully characterized as a potential target. This paper will present evaluations of Antarctica as a microwave calibration target for the above satellite missions. Preliminary analyses have identified likely target areas, such as the vicinity of Dome-C and larger areas within East Antarctica. Physical sources of temporal and spatial variability of polar firn are key to assessing calibration uncertainty. These sources include spatial variability of accumulation rate, compaction, surface characteristics (dunes, micro-topography), wind patterns, and vertical profiles of density and temperature. Using primarily SMOS data, variability is being empirically characterized and attempts are being made to attribute observed variability to physical sources. One expected outcome of these studies is the potential discovery of techniques for remotely sensing--over all of Antarctica--parameters such as surface temperature.

Kim, Edward↗

Calibration and Validation of the SAIL Radar

Calibration of a weather radar is not a simple process, as is well described and documented in several articles (Chandrasekar, V, L Baldini, N Bharadwaj, and PL Smith. 2015. "Calibration procedures for global precipitation-measurement ground-validation radars." URSI Radio Science Bulletin 2015(355): 45–73, https://10.23919/URSIRSB.2015.7909473.). Direct hardware-based characterization is called calibration whereas indirect check with other sources such as disdrometer, or comparison with other radars or indirect means, is called validation. The validation process has its own measurement error and the comparison should fall within its limit. In the following we describe calibration and validation processes for the SAIL radar. Based on the comparison of calibration and validation, an addition of 2 dB is suggested for the SAIL radar observations, with a nuanced Z dr calibration correction, as presented. If a fixed Z dr calibration is preferred, a bias addition of 0.5 dB is suggested.

54 ENVIRONMENTAL SCIENCES↗

X-ray microscope for solidification studies

This report covers the second 6 month period for the year March 1, 1994 to February 28, 1995. The material outlined in this semi-annual report continues from the previous semi-annual report. The Fein Focus Inc. x-ray source was delivered in September and coincides with the beginning of the second 6 month effort. As a result, and as outlined in the statement of work, this period was dedicated to the evaluation, testing and calibration of the x-ray source. In addition, in this period the modeling effort was continued and extended by the Tiger series of Monte-Carlo simulation programs for photon and electron interactions with materials obtained from the Oak Ridge RISC Library. Some further calculations were also made with the absorption model.

Kaukler, William↗

Cal X-1, a Pioneer mission for absolute in-orbit flux calibration for current and future X-ray observatories

X-ray astronomy missions are now making observations capable of answering fundamental physics and cosmology questions. However, those studies are often limited by lack of absolute X-ray flux calibration; the most powerful X-ray observatories reveal discrepancies in the source fluxes at the 10-20% level. These discrepancies are plausibly related to changes in the instrument performance between the ground calibration and the orbit. We propose to overcome this problem by establishing "standard candles" in the X-ray sky. Our Cal X-1 mission, a Pioneer concept, will consist of 2 small satellites flying in tandem. One will have an X-ray telescope and the other, a pair of absolutely-calibrated X-ray sources (E=1.5 keV and 6 keV). The telescope will ping-pong between the source satellite and several well-chosen constant celestial sources, determining the accurate fluxes of those sources and turning them into standard candles for all other X-ray observatories, current and future.

Maxim Markevitch↗

Analysis of the pre-flight and post-flight calibration procedures performed on the Liulin space radiation dosimeter

Liulin, a dosimetry-radiometry system, was developed to satisfy the requirements for active flux and dose rate measurements for the flight of the second Bulgarian cosmonaut in 1988. The system consists of a compact battery-operated silicon solid state detector unit and a read/write microcomputer and telemetry unit. We describe the pre-flight calibrations with charged particles, using radioactive sources and accelerated 170 MeV/nucleon proton and alpha particles at the Dubna, Russia cyclotron. We discuss comparisons with data obtained on Mir with the French-built tissue equivalent LET spectrometer NAUSICAA. Lastly, we describe post-flight calibrations performed with 1 GeV/nucleon 56Fe ions at the Brookhaven National Laboratory AGS accelerator, where the instrument was mounted in tandem with several thin position-sensitive silicon detectors behind a stopping target. The silicon detectors provided an energy spectrum for the surviving charged nuclear fragments for which the flux and absorbed dose were recorded by Liulin.

long duration↗

Explanatory Supplement to the WISE All-Sky Release Products

The Wide-field Infrared Survey Explorer (WISE; Wright et al. 2010) surveyed the entire sky at 3.4, 4.6, 12 and 22 microns in 2010, achieving 5-sigma point source sensitivities per band better than 0.08, 0.11, 1 and 6 mJy in unconfused regions on the ecliptic. The WISE All-Sky Data Release, conducted on March 14, 2012, incorporates all data taken during the full cryogenic mission phase, 7 January 2010 to 6 August 20l0,that were processed with improved calibrations and reduction algorithms. Release data products include: (1) an Atlas of 18,240 match-filtered, calibrated and coadded image sets; (2) a Source Catalog containing positions and four-band photometry for over 563 million objects, and (3) an Explanatory Supplement. Ancillary products include a Reject Table that contains 284 million detections that were not selected for the Source Catalog because they are low signal-to-noise ratio or spurious detections of image artifacts, an archive of over 1.5 million sets of calibrated WISE Single-exposure images, and a database of 9.4 billion source extractions from those single images, and moving object tracklets identified by the NEOWISE program (Mainzer et aI. 2011). The WISE All-Sky Data Release products supersede those from the WISE Preliminary Data Release (Cutri et al. 2011). The Explanatory Supplement to the WISE All-Sky Data Release Products is a general guide for users of the WISE data. The Supplement contains an overview of the WISE mission, facilities, and operations, a detailed description of WISE data processing algorithms, a guide to the content and formals of the image and tabular data products, and cautionary notes that describe known limitations of the All-Sky Release products. Instructions for accessing the WISE data products via the services of the NASA/IPAC Infrared Science Archive are provided. The Supplement also provides analyses of the achieved sky coverage, photometric and astrometric characteristics and completeness and reliability of the All-Sky Release data products. The WISE All-Sky Release Explanatory Supplement is an on-line document that is updated frequently to provide the most current information for users of the WISE data products. The Explanatory Supplement is maintained at: http://wise2.ipac.caltech.edu/docs/release/allsky/expsup/index.html WISE is a joint project of the University of California, Los Angeles and the Jet Propulsion Laboratory/California Institute of Technology, funded by the National Aeronautics and Space Administration. NEOWISE is a project of the Jet Propulsion Laboratory/California Institute of Technology, funded by the Planetary Science Division of the National Aeronautics and Space Administration.

Source record↗

LANL MPCL Measurement System Analysis: AMPTEC 630ES Igniter Tester / Ohmmeter

This comprehensive analysis aimed to evaluate the measurement capability of the AMPTEC 630ES Explosive Safety Igniter Tester, a critical tool for organizations engaged in the measurement of High Explosive components and related Electro-Explosive devices. With a history of notable calibration issues involving specific model numbers, the Metrology Program and Calibration Laboratory (MPCL) initiated an extensive Measurement System Analysis. The analysis's primary focus was to thoroughly quantify the various sources of measurement variability intrinsic to the calibration process. It centered on two pivotal aspects: repeatability (the variation observed when the same operator uses the same instrument) and reproducibility (the variation seen when different operators perform measurements). A secondary objective was to determine whether equipment usage and age had any impact on the instrument's performance.

47 OTHER INSTRUMENTATION↗

Absolute radiometric calibration of detectors between 200-600 A

A description is given of the experimental methods used in the calibration procedure, taking into account the source of radiant energy, the monochromator, the absolute standard detector, and the transfer standards. The experimental apparatus is discussed. A graph showing the effect of beam motion on the detected signal is presented and a block diagram of the calibration electronic system is provided.

Saloman, E. B.↗