Search NASA⌕ Search

SEARCH · Search NASA

Results for “computerized procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Excitonic couplings between molecular crystal pairs by a multistate approximation

In this paper, we present a diabatization scheme to compute the excitonic couplings between an arbitrary number of states in molecular pairs. The method is based on an algebraic procedure to find the diabatic states with a desired property as close as possible to that of some reference states. In common with other diabatization schemes, this method captures the physics of the important short-range contributions (exchange, overlap, and charge-transfer mediated terms) but it becomes particularly suitable in presence of more than two states of interest. The method is formulated to be usable with any level of electronic structure calculations and to diabatize different types of states by selecting different molecular properties. These features make the diabatization scheme presented here especially appropriate in the context of organic crystals, where several excitons localized on the same molecular pair may be found close in energy. In this paper, the method is validated on the tetracene crystal dimer, a well characterized case where the charge transfer (CT) states are closer in energy to the Frenkel excitons (FE). The test system was studied as a function of an external electric field (to explore the effect of changing the relative energy of the CT excited state) and as a function of different intermolecular distances (to probe the strength of the coupling between FE and CT states). Additionally, we illustrate how the approximation can be used to include the environment polarization effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical constants of Cu(In, Ga)Se{sub 2} for arbitrary Cu and Ga compositions

The optical constants of Cu(In, Ga)Se{sub 2} (CIGS)-based polycrystalline layers with different Cu and Ga compositions are parameterized completely up to a photon energy of 6.5 eV assuming several Tauc-Lorentz transition peaks. Based on the modeled optical constants, we establish the calculation procedure for the CIGS optical constants in a two-dimensional compositional space of (Cu, Ga) by taking the composition-induced shift of the critical point energies into account. In particular, we find that the variation of the CIGS optical constants with the Cu composition can be modeled quite simply by a spectral-averaging method in which the dielectric function of the target Cu composition is estimated as a weighted average of the dielectric functions with higher and lower Cu compositions. To express the effect of the Ga composition, on the other hand, an energy shift model reported earlier is adopted. Our model is appropriate for a wide variety of CIGS-based materials having different Cu and Ga compositions, although the modeling error increases slightly at lower Cu compositions [Cu/(In + Ga) < 0.69]. From our model, the dielectric function, refractive index, extinction coefficient, and absorption coefficient for the arbitrary CIGS composition can readily be obtained. The optical database developed in this study is applied further for spectroscopic ellipsometry analyses of CIGS layers fabricated by single and multi-stage coevaporation processes. We demonstrate that the compositional and structural characterizations of the CIGS-based layers can be performed from established analysis methods.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TU-G-204-04: A Unified Strategy for Bi-Factorial Optimization of Radiation Dose and Contrast Dose in CT Imaging

Purpose: To substantiate the interdependency of contrast dose, radiation dose, and image quality in CT towards the patient- specific optimization of the imaging protocols Methods: The study deployed two phantom platforms. A variable sized (12, 18, 23, 30, 37 cm) phantom (Mercury-3.0) containing an iodinated insert (8.5 mgI/ml) was imaged on a representative CT scanner at multiple CTDI values (0.7–22.6 mGy). The contrast and noise were measured from the reconstructed images for each phantom diameter. Linearly related to iodine-concentration, contrast-to-noise ratio (CNR), were calculated for 16 iodine-concentration levels (0–8.5 mgI/ml). The analysis was extended to a recently developed suit of 58 virtual human models (5D XCAT) with added contrast dynamics. Emulating a contrast-enhanced abdominal image procedure and targeting a peak-enhancement in aorta, each XCAT phantom was “imaged” using a simulation platform (CatSim, GE). 3D surfaces for each patient/size established the relationship between iodine-concentration, dose, and CNR. The ratios of change in iodine-concentration versus dose (IDR) to yield a constant change in CNR were calculated for each patient size. Results: Mercury phantom results show the image-quality size- dependence on CTDI and IC levels. For desired image-quality values, the iso-contour-lines reflect the trade off between contrast-material and radiation doses. For a fixed iodine-concentration (4 mgI/mL), the IDR values for low (1.4 mGy) and high (11.5 mGy) dose levels were 1.02, 1.07, 1.19, 1.65, 1.54, and 3.14, 3.12, 3.52, 3.76, 4.06, respectively across five sizes. The simulation data from XCAT models confirmed the empirical results from Mercury phantom. Conclusion: The iodine-concentration, image quality, and radiation dose are interdependent. The understanding of the relationships between iodine-concentration, image quality, and radiation dose will allow for a more comprehensive optimization of CT imaging devices and techniques, providing the methodology to balance iodine-concentration and dose based on patient’s attributes.

60 APPLIED LIFE SCIENCES↗

SU-E-T-10: A Clinical Implementation and the Dosimetric Evidence in High Dose Rate Vaginal Multichannel Applicator Brachytherapy

Purpose: The multichannel cylindrical applicator has a distinctive modification of the traditional single channel cylindrical applicator. The novel multichannel applicator has additional peripheral channels that provide more flexibility both in treatment planning process and outcomes. To protect by reducing doses to adjacent organ at risk (OAR) while maintaining target coverage with inverse plan optimization are the goals for such novel Brachytherapy device. Through a series of comparison and analysis of reults in more than forty patients who received HDR Brachytherapy using multichannel vaginal applicator, this procedure has been implemented in our institution. Methods: Multichannel planning was CT image based. The CTV of 5mm vaginal cuff rind with prescribed length was well reconstructed as well as bladder and rectum. At least D95 of CTV coverage is 95% of prescribed dose. Multichannel inverse plan optimization algorithm not only shapes target dose cloud but set dose avoids to OAR’s exclusively. The doses of D2cc, D5cc and D5; volume of V2Gy in OAR’s were selected to compare with single channel results when sole central channel is only possibility. Results: Study demonstrates plan superiorly in OAR’s doe reduction in multi-channel plan. The D2cc of the rectum and bladder were showing a little lower for multichannel vs. single channel. The V2Gy of the rectum was 93.72% vs. 83.79% (p=0.007) for single channel vs. multichannel respectively. Absolute reduced mean dose of D5 by multichannel was 17 cGy (s.d.=6.4) and 44 cGy (s.d.=15.2) in bladder and rectum respectively. Conclusion: The optimization solution in multichannel was to maintain D95 CTV coverage while reducing the dose to OAR’s. Dosimetric advantage in sparing critical organs by using a multichannel applicator in HDR Brachytherapy treatment of the vaginal cuff is so promising and has been implemented clinically.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-T-02: Dosimetric Accuracy of the CrystalBallâ„¢: New Reusable Radiochromic Polymer Gel Dosimeter for Patient QA in Proton Therapy

Purpose: To evaluate the accuracy of monoexponential normalization in a new class of commercial, reusable, human-soft-tissue-equivalent, radiochromic polymer gel dosimeters for patient-specific QA in proton therapy. Methods: Eight formulations of the dosimeter (sealed in glass spheres of 166 mm OD), were exposed to a 150 MeV proton beam (5 cm x 5 cm square field, range 15 cm, modulation10 cm), with max dose ranging from 2.5 Gy to 20 Gy, depending on formulation. Exposed dosimeters were promptly placed in the commercial OCTOPUS™ laser CT scanner which was programmed to scan the central slice every 5 minutes for 20 hours (15 seconds per slice scan). This procedure was repeated several times. Reconstructed data were analyzed using the log-lin scale to determine the time range over which a monoexponential relaxation model could be applied. Next, a simple test plan was devised and delivered to each dosimeter. The OCTOPUS™ was programmed to rescan the central slice at the end of each volume scan, for signal relaxation reference. Monoexponential normalization was applied to sinograms before FBP reconstruction. Dose calibration was based on a volume-lookup table built within the central spherical volume of 12 cm diameter. 3D gamma and sigma passing rates were measured at 3%/3mm criteria down to 50% isodose. Results: Approximately monoexponential signal relaxation time ranges from 25 minutes to 3.5 hours, depending on formulation, followed by a slower-relaxation component. Noise in reconstructed OD/cm images is less than 0.5%. Dose calibration accuracy is better than 99%. Measured proton PDDs demonstrate absence of Bragg-peak quenching. Estimated number of useful cycles is at least 20, with a theoretical limit above 100. 3D gamma and sigma passing rates exceed 95%. Conclusion: Monoexponential normalization was found to yield adequate dosimetric accuracy in the new class of commercial radiochromic polymer gel dosimeters for patient QA in proton therapy.

60 APPLIED LIFE SCIENCES↗

Quantifying uncertainty in LCA-modelling of waste management systems

Highlights: Black-Right-Pointing-Pointer Uncertainty in LCA-modelling of waste management is significant. Black-Right-Pointing-Pointer Model, scenario and parameter uncertainties contribute. Black-Right-Pointing-Pointer Sequential procedure for quantifying uncertainty is proposed. Black-Right-Pointing-Pointer Application of procedure is illustrated by a case-study. - Abstract: Uncertainty analysis in LCA studies has been subject to major progress over the last years. In the context of waste management, various methods have been implemented but a systematic method for uncertainty analysis of waste-LCA studies is lacking. The objective of this paper is (1) to present the sources of uncertainty specifically inherent to waste-LCA studies, (2) to select and apply several methods for uncertainty analysis and (3) to develop a general framework for quantitative uncertainty assessment of LCA of waste management systems. The suggested method is a sequence of four steps combining the selected methods: (Step 1) a sensitivity analysis evaluating the sensitivities of the results with respect to the input uncertainties, (Step 2) an uncertainty propagation providing appropriate tools for representing uncertainties and calculating the overall uncertainty of the model results, (Step 3) an uncertainty contribution analysis quantifying the contribution of each parameter uncertainty to the final uncertainty and (Step 4) as a new approach, a combined sensitivity analysis providing a visualisation of the shift in the ranking of different options due to variations of selected key parameters. This tiered approach optimises the resources available to LCA practitioners by only propagating the most influential uncertainties.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hemorrhagic Complications of Percutaneous Cryoablation for Renal Tumors: Results from a 7-year Prospective Study

PurposeCryoablation of renal tumors is assumed to have a higher risk of hemorrhagic complications compared to other ablative modalities. Our purpose was to establish the exact risk and to identify hemorrhagic risk factors.Materials and MethodsThis IRB approved, 7-year prospective study included 261 renal cryoablations. Procedures were under conscious sedation and CT guidance. Pre- and postablation CT was obtained, and hemorrhagic complications were CTCAE tabulated. Age, gender, tumor size, histology, and probes number were tested based on averages or proportions using their exact permutation distribution. “High-risk” subgroups (those exceeding the thresholds of all variables) were tested for each variable alone, and for all combinations of variable threshold values. We compared the subgroup with the best PPV using one variable, with the subgroup with the best PPV using all variables (McNemmar test).ResultsThe hemorrhagic complication rate was 3.5 %. Four patients required transfusions, two required emergent angiograms, one required both a transfusion and angiogram, and two required bladder irrigation for outlet obstruction. Perirenal space hemorrhage was more clinically significant than elsewhere. Univariate risks were tumor size >2 cm, number of probes >2, and malignant histology (P = 0.005, 0.002, and 0.033, respectively). Multivariate analysis showed that patients >55 years with malignant tumors >2 cm requiring 2 or more probes yielded the highest PPV (7.5 %).ConclusionsAlthough older patients (>55 years old) with larger (>2 cm), malignant tumors have an increased risk of hemorrhagic complications, the low PPV does not support the routine use of embolization. Percutaneous cryoablation has a 3.5 % risk of significant hemorrhage, similar to that reported for other types of renal ablative modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-275: Impact of the Intra and Inter Observer Variability in the Delineation of Parotid Glands On the Dose Calculation During Head and Neck Helical Tomotherapy

Purpose: The intra- and inter-observer variability in delineation of the parotids on the kilo-voltage computed tomography (kVCT) and mega-voltage computed tomography (MVCT) were examined to establish their impact on the dose calculation during adaptive head and neck helical tomotherapy (HT). Methods: Three observers delineated left and right parotids for ten randomly selected patients with oropharynx cancer treated on HT. The pre-treatment kVCT and the MVCT from the first fraction of irradiation were selected to delineation. The delineation procedure was repeated three times by each observer. The parotids were delineated according to the institutional protocol. The analyses included intra-observer reproducibility and inter-structure, -observer and -modality variability of the volume and dose. Results: The differences between the left and right parotid outlines were not statistically significant (p>0.3). The reproducibility of the delineation was confirmed for each observer on the kVCT (p>0.2) and on the MVCT (p>0.1). The inter-observer variability of the outlines was significant (p<0.001) as well as the inter-modality variability (p<0.006). The parotids delineated on the MVCT were 10% smaller than on the kVCT. The inter-observer variability of the parotids delineation did not affect the average dose (p=0.096 on the kVCT and p=0.176 on the MVCT). The dose calculated on the MVCT was higher by 3.3% than dose from the kVCT (p=0.009). Conclusion: Usage of the institutional protocols for the parotids delineation reduces intra-observer variability and increases reproducibility of the outlines. These protocols do not eliminate delineation differences between the observers, but these differences are not clinically significant and do not affect average doses in the parotids. The volumes of the parotids delineated on the MVCT are smaller than on the kVCT, which affects the differences in the calculated doses.

60 APPLIED LIFE SCIENCES↗

Enhancing power plant safety through simulated cyber events - 341

There are gaps in understanding how a cyber-attack would manifest itself within power plants and what these events would look like within the control room from an operator's perspective. This is especially true for nuclear power plants where safety has much broader consequences than nonnuclear plants. The operating and emergency procedures that operators currently use are likely inadequate for targeted cyber-attacks. This research focuses on understanding how a cyber event would affect the operation of the plant, how an operator would perceive the event, and if the operator's actions would keep the plant in a safe condition. This research is part of Sandia's Laboratory Directed Research and Development program where a nuclear power plant cyber model of the control system digital architecture is coupled with a generic pressurized water reactor plant training simulator. Cyber event scenarios will be performed on the coupled system with plant operators. The scenarios simulate plant conditions that may exist during a cyber-attack, component failure, or insider sabotage, and provide an understanding of the displayed information and the actual plant conditions. These scenarios will determine if plant operators can 1) recognize that they are under cyber-attack and 2) take appropriate actions to keep the plant safe. This will also provide the opportunity to assess the operator cognitive workload during such events and identify where improvements might be made. Experiments with nuclear power plant operators will be carried out over FY 2018 and results of the research are expected by the end of FY 2018. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Statistical and sensitivity analysis of failing rods in EPR LBLOCA

A statistical fuel failure analysis procedure has been developed, and is now applied in full scale to a large break loss-of-coolant accident (LBLOCA) scenario in EPR-type nuclear power plant. The goal is to statistically determine the number of failing fuel rods. It is also important to bring out the underlying causes for rod failures, and therefore a sensitivity analysis procedure for the preceding complex calculation chain is outlined and adopted. In order to produce a statistically reliable estimation on the number of failing rods, a large number of simulations are required. In the analysis, single rods are simulated with the coupled fuel performance - thermal hydraulics code FRAPTRAN-GENFLO. The statistically varied factors are divided into global and local by their range of influence. Transient thermal hydraulic and power history boundary conditions and model parameters are global and affect all the rods. Fuel rod manufacturing parameters and other rod position related factors are local and are related to a certain rod. The number of global scenarios is 59 as dictated by the Wilks' formula, and 1000 randomly sampled rods are simulated in each scenario. The thermal hydraulic and transient power boundary conditions for the fuel performance code are calculated with a statistical version of the system code APROS. The steady-state irradiation histories are simulated with FRAPCON, and the steady-state power histories used as boundary conditions for FRAPCON are obtained from SIMULATE calculations. Thus, a multistage calculation chain is required to consolidate the procedure. As an outcome, in the worst global scenario, 1.4% of the simulated rods failed. It can be concluded that the Finnish safety regulations, i.e. max. 10% of the rods allowed to fail, are met. In order to find out which input parameters have significance to the outcome of the analysis, a sensitivity analysis is done. At the moment, only the worst global scenario is considered but later on it is possible to include also the sensitivities of the global factors. Due to complexity of the existing data, first the relevant input parameters for the sensitivity analysis have to be specified. Data visualization with a cobweb graph is used for the screening. Then, selected sensitivity measures are calculated between the chosen input and output parameters. The sensitivity indices calculated are the Borgonovo's delta measure, the first order Sobol sensitivity index, and squared Pearson correlation coefficients. The first mentioned is a novelty in this context. As an outcome, the most relevant parameters with respect to the cladding integrity were determined to be the decay heat power during the transient, the thermal hydraulic conditions in the rod's location in the reactor, and the steady-state irradiation history of the rod as represented in this analysis by the rod burnup. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Poster — Thur Eve — 12: Implementation of a Clinical Lung Tumour High Dose Containment Verification Procedure using Respiratory Cone-Beam CT (4DCBCT) on a Varian TrueBeam Linac

Lung tumours move due to respiratory motion. This is managed during planning by acquiring a 4DCT and capturing the excursion of the GTV (gross tumour volume) throughout the breathing cycle within an IGTV (Internal Gross Tumour Volume) contour. Patients undergo a verification cone-beam CT (CBCT) scan immediately prior to treatment. 3D reconstructed images do not consider tumour motion, resulting in image artefacts, such as blurring. This may lead to difficulty in identifying the tumour on reconstructed images. It would be valuable to create a 4DCBCT reconstruction of the tumour motion to confirm that does indeed remain within the planned IGTV. CBCT projections of a Quasar Respiratory Motion Phantom are acquired in Treatment mode (half-fan scan) on a Varian TrueBeam accelerator. This phantom contains a mobile, low-density lung insert with an embedded 3cm diameter tumour object. It is programmed to create a 15s periodic, 2cm (sup/inf) displacement. A Varian Real-time Position Management (RPM) tracking-box is placed on the phantom breathing platform. Breathing phase information is automatically integrated into the projection image files. Using in-house Matlab programs and RTK (Reconstruction Tool Kit) open-source toolboxes, the projections are re-binned into 10 phases and a 4DCBCT scan reconstructed. The planning IGTV is registered to the 4DCBCT and the tumour excursion is verified to remain within the planned contour. This technique successfully reconstructs 4DCBCT images using clinical modes for a breathing phantom. UBC-BCCA ethics approval has been obtained to perform 4DCBCT reconstructions on lung patients (REB#H12-00192). Clinical images will be accrued starting April 2014.

60 APPLIED LIFE SCIENCES↗

Assessing pellet-clad interaction with VERA: WBN1, cycles 6-7

The Consortium for Advanced Simulation of Light Water Reactors (CASL) aims to provide high fidelity simulations of nuclear reactors through the development of the Virtual Environment for Reactor Applications (VERA). One of the primary goals of CASL is to estimate local cladding failure through pellet-clad interaction (PCI). While this capability is being pursued through several different approaches, the procedure presented here focuses on running independent fuel performance calculations with the BISON fuel performance code being developed by Idaho National Laboratory using the multicycle output data from coupled neutron transport/thermal-hydraulics simulations generated by MPACT, CTF, and MAMBA. This type of approach is consistent with traditional fuel performance analysis methods, where the fuel performance analyses are typically separate from core simulation analyses. Recent work simulating 12 cycles of Watts Bar Unit 1 (WBN1) with VERA are capitalized upon, and stand-alone quarter-core BISON results can be obtained for several cycles, assessing parameters of interest to PCI (e.g., maximum centerline fuel temperature, maximum clad hoop stress, minimum gap thickness, and cumulative damage index). This is accomplished by using the coupled neutronics/thermal-hydraulics output power and temperature distributions as inputs for each BISON fuel rod case. Building on previous work which demonstrated this capability for Cycles 1 through 3, this paper presents the results for Cycles 6 and 7. Cycle 7 is of particular interest because significant CRUD-induced power shift was observed. While the current results do not immediately indicate that any rods are at an extreme risk of failure, further analysis on rods highlighted by this work may shed additional light on the likelihood of failure. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Determination of critical experiment correlations for experiments involving highly enriched uranium solutions

Quantifying the correlations among critical experiments has become a topic of interest over the last 10-15 years. The correlations arise from the shared use of fissile material, non-fissile materials, fixtures, and procedures in multiple experiments or multiple experiment series. A Monte Carlo sampling technique proposed as a viable technical method to evaluate these correlations has been implemented within the SCALE 6.2 Sampler sequence. This paper presents the investigation of the use of this new tool and technique for highly enriched uranium solution experiments. One of the first attempts to quantify the correlations among critical experiments examined a series of highly enriched solution experiments, including the HST-001 series. These correlations are included in the International Criticality Safety Benchmark Evaluation Project Handbook, and they form a basis for methodology comparisons. Results generated using the Sampler implementation are compared with these previously published results. Additional studies involving the HST-001 experiment series are also presented. A range of different assumptions of the independence of the geometry components, enrichments, and other material compositions are implemented to investigate the impact of these assumptions on the correlation coefficients. These effects are investigated with these experiments because the calculation time is shorter for the solution experiments than for the low-enriched lattice experiments discussed in a companion paper. The magnitude of the effects of different independence assumptions on the correlation coefficients is important to establish which parameters must be clearly identified as shared or unique for accurate correlation determinations. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Toward Transpulmonary Chemoembolization with Degradable Starch Microspheres: Systematic Analysis of Local and Systemic Effects in a Porcine Model

Purpose: To investigate local and systemic effects of transpulmonary chemoembolization (TPCE) with degradable starch microspheres (DSM) and doxorubicin. The long-term goal is to establish DSM-TPCE as a treatment option for pulmonary malignancies. Materials and Methods: Nine pigs underwent TPCE of either the right or left lower lobe pulmonary artery (LLPA) and bland embolization (TPE) of the contralateral LLPA. Before the procedures, macroaggregated albumin (MAA) particles were injected into both LLPAs, to exclude systemic shunting. Pulmonary arterial pressure, heart rate and oxygenation were recorded immediately before and at 1, 3, 5 and 10 min after treatment. To investigate possible nontarget embolization, animals underwent cerebral MRI (cMRI). We killed the animals after a contrast-enhanced chest computed tomography (CT) and performed a pathologic examination at 12 h (3), 24 h (3) and 72 h (3) after treatment. Results: All experiments were technically successful. Mean injected DSM dose until stasis was similar in TPCE and TPE (4.3 ± 1.4 vs. 4.0 ± 1.4 mL). Pulmonary arterial pressure increased significantly 3 min after treatment (TPE: 17 ± 5 vs. 27 ± 7 mmHg; TPCE: 22 ± 6 vs. 36 ± 8 mmHg). No significant changes in heart rate or peripheral oxygenation levels occurred. We observed no evidence of structural lung damage or permanent perfusion disruption on CT. MAA test injection and cMRI revealed no shunting or nontarget embolization. The pathologic assessment revealed nonspecific local inflammation of the lung parenchyma. Conclusion: In this large-animal model, TPCE and TPE appear feasible and safe. We observed a mild increase in pulmonary arterial pressure. Nontarget embolization did not occur. TPCE, as well as TPE, did not cause structural damage to the normal lung parenchyma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High performance techniques for micro channel plate computations in photo multipliers

Monte Carlo - MC methods, requiring heavy computations of large data volume, can be used to predict the amplitude distribution and variance of outputted electron charge in Micro Channel Plates - MCPs, which are fed with primary emitted electrons in their inputs. The concept of parallel and serial combination of separate stages of such stochastic processes, which can be applied in MCP systems and simulated using MC computations, has recently proposed and shown interesting theorems and results. Separating the electron multiplication procedures, occurring in the channels of MCP systems, into sub-procedures, which are similar in nature and occur either in parallel or in consecutive manners, is equivalent to splitting the relevant stochastic system calculations into smaller ones, which can be performed concurrently and/or sequentially. In this way, calculations similar in nature, can be executed only once, thus, eliminating a great percentage of heavy computations. However, when designing and implementing the calculation inferences of the derived theorems using High Performance Computation - HPC techniques, the overall computation cost can further and significantly be reduced. In this paper, the hardware mappings of the relevant theorem inferences onto parallel computing architectures, resulting in circuits of computing blocks for calculation purposes of MCP system stochastic processes, are investigated. Each of the designed and implemented computing circuits corresponds to a theorem inference or to a combination of inferences. The parallelism of the proposed circuits consists of both the concurrent functioning of all the system blocks and of the simultaneous operation of each block, which is processing pieces of data, for many parts of the whole circuit in which it belongs. All the circuits are designed and tested using Altera Quartus II environment and can be implemented as chips, which can be incorporated in computing devices to assist Monte Carlo computations for the estimation of different MCP electron multiplication system performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-I-20: Comprehensive Quality Assurance Test of Second Generation Toshiba Aquilion Large Bore CT Simulator Based On AAPM TG-66 Recommendations

Purpose: AAPM radiation therapy committee task group No. 66 (TG-66) published a report which described a general approach to CT simulator QA. The report outlines the testing procedures and specifications for the evaluation of patient dose, radiation safety, electromechanical components, and image quality for a CT simulator. The purpose of this study is to thoroughly evaluate the performance of a second generation Toshiba Aquilion Large Bore CT simulator with 90 cm bore size (Toshiba, Nasu, JP) based on the TG-66 criteria. The testing procedures and results from this study provide baselines for a routine QA program. Methods: Different measurements and analysis were performed including CTDIvol measurements, alignment and orientation of gantry lasers, orientation of the tabletop with respect to the imaging plane, table movement and indexing accuracy, Scanogram location accuracy, high contrast spatial resolution, low contrast resolution, field uniformity, CT number accuracy, mA linearity and mA reproducibility using a number of different phantoms and measuring devices, such as CTDI phantom, ACR image quality phantom, TG-66 laser QA phantom, pencil ion chamber (Fluke Victoreen) and electrometer (RTI Solidose 400). Results: The CTDI measurements were within 20% of the console displayed values. The alignment and orientation for both gantry laser and tabletop, as well as the table movement and indexing and scanogram location accuracy were within 2mm as specified in TG66. The spatial resolution, low contrast resolution, field uniformity and CT number accuracy were all within ACR’s recommended limits. The mA linearity and reproducibility were both well below the TG66 threshold. Conclusion: The 90 cm bore size second generation Toshiba Aquilion Large Bore CT simulator that comes with 70 cm true FOV can consistently meet various clinical needs. The results demonstrated that this simulator complies with the TG-66 protocol in all aspects including electromechanical component, radiation safety component, and image quality component. Employee of Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

A robust geometry estimation method for spiral, sequential and circular cone-beam micro-CT

Purpose: The authors propose a novel method for misalignment estimation of micro-CT scanners using an adaptive genetic algorithm. Methods: The proposed algorithm is able to estimate the rotational geometry, the direction vector of table movement and the displacement between different imaging threads of a dual source or even multisource scanner. The calibration procedure does not rely on dedicated calibration phantoms and a sequence scan of a single metal bead is sufficient to geometrically calibrate the whole imaging system for spiral, sequential, and circular scan protocols. Dual source spiral and sequential scan protocols in micro-computed tomography result in projection data that-besides the source and detector positions and orientations-also require a precise knowledge of the table direction vector to be reconstructed properly. If those geometric parameters are not known accurately severe artifacts and a loss in spatial resolution appear in the reconstructed images as long as no geometry calibration is performed. The table direction vector is further required to ensure that consecutive volumes of a sequence scan can be stitched together and to allow the reconstruction of spiral data at all. Results: The algorithm's performance is evaluated using simulations of a micro-CT system with known geometry and misalignment. To assess the quality of the algorithm in a real world scenario the calibration of a micro-CT scanner is performed and several reconstructions with and without geometry estimation are presented. Conclusions: The results indicate that the algorithm successfully estimates all geometry parameters, misalignment artifacts in the reconstructed volumes vanish, and the spatial resolution is increased as can be shown by the evaluation of modulation transfer function measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Validation of a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial HDR brachytherapy

Purpose: In current clinical practice, there is no integrated 3D ultrasound (3DUS) guidance system clinically available for breast brachytherapy. In this study, the authors present a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial high dose rate (HDR) brachytherapy treatment. Methods: For this work, a new computer controlled robotic 3DUS system was built to perform a hybrid motion scan, which is a combination of a 6 cm linear translation with a 30° rotation at both ends. The new 3DUS scanner was designed to fit on a modified Kuske assembly, keeping the current template grid configuration but modifying the frame to allow the mounting of the 3DUS system at several positions. A finer grid was also tested. A user interface was developed to perform image reconstruction, semiautomatic segmentation of the surgical bed as well as catheter reconstruction and tracking. A 3D string phantom was used to validate the geometric accuracy of the reconstruction. The volumetric accuracy of the system was validated with phantoms using magnetic resonance imaging (MRI) and computed tomography (CT) images. In order to accurately determine whether 3DUS can effectively replace CT for treatment planning, the authors have compared the 3DUS catheter reconstruction to the one obtained from CT images. In addition, in agarose-based phantoms, an end-to-end procedure was performed by executing six independent complete procedures with both 14 and 16 catheters, and for both standard and finer Kuske grids. Finally, in phantoms, five end-to-end procedures were performed with the final CT planning for the validation of 3DUS preplanning. Results: The 3DUS acquisition time is approximately 10 s. A paired Student t-test showed that there was no statistical significant difference between known and measured values of string separations in each direction. Both MRI and CT volume measurements were not statistically different from 3DUS volume (Student t-test: p > 0.05) and they were significantly correlated to 3DUS measurement (Pearson test: MRI p < 0.05 and CT p < 0.001). The mean angular separation distance between catheter trajectories segmented from 3DUS and CT images was 0.42° ± 0.24°, while the maximum and mean trajectory separations were 0.51 ± 0.19 and 0.37 ± 0.17 mm, respectively. Overall, the new finer grid has performed significantly better in terms of dosimetric indices. The planning target volume dosimetric indices were not found statistically different between 3DUS and CT planning (Student t-test, p > 0.05). Both the skin and the pectoral muscle dosimetric indices were within ABS guidelines. Conclusions: A novel robot-assisted 3DUS system was designed and validated. To their knowledge, this is the first system capable of performing real-time guidance and planning of breast multicatheter HDR brachytherapy treatments. Future investigation will test the feasibility of using the system in the clinic and for permanent breast brachytherapy.

60 APPLIED LIFE SCIENCES↗