Cyber-Physical Dynamic System (CPDS) Modeling for Frequency Regulation and AGC Services of Distributed Energy Resources

The substantial integration of renewable energy brings significant challenges to balance the system in real time because of the variability and intermittency of renewable power. For the reliable system operation, the frequency regulation service is used to stabilize the system frequency through automatically balancing the system generation and load. On one hand, with the substantially increasing deployment of renewable energy in electricity system, the requirement of frequency regulation (FR) services increases significantly. On the other hand, the current main resource of FR services, the controllable conventional generation, is continuously decreasing in the system generation mix. This means that in the future high renewable penetration power system, additional and alternative reliable FR services providers such as distributed energy storage (DES) resources should be explored. Although the capability of utility-scale energy storage to provide FR services has been demonstrated, the integrated control and dynamic modeling of distributed energy resource (DER) providing frequency regulation grid services has been rarely explored. There are several challenges to adopt DERs to provide reliable grid services as illustrated in FERC 755. First, the distributed installation of DES requires a comprehensive cyber-physical dynamic system (CPDS) modeling to fully consider the impacts of the communication latency variability on its real time FR provision capability. Unlike the conventional generators, there are two-layer communication between DERs and system operators which increase the communication delay. Second, unlike the conventional generators whose dynamic models have been comprehensively studied, the difference among individual DER components' power-dynamic characteristic brings challenges in the accurate dynamic AGC modeling of its power-frequency relationship. Third, the temporal dependent state of charge uncertainty of DERs challenges DERs' power and frequency regulation capacities scheduling in the look-ahead generation scheduling. Therefore, the aggregator should optimize the frequency regulation provision from individual DER in real time. To overcome these challenges, this project proposes a cyber-physical dynamic system (CPDS) model to handle the uncertainty of DERs two-layer communication latency and power dynamics. The variability of DERs' communication delay and dynamic constraints will be comprehensively modeled. The DERs' AGC model with communication delay is designed to validate DESs' frequency regulation services. Like current performance-based frequency regulation evaluation, the delivery of DERs' frequency regulation will be assessed through post-analysis of the actual AGC response with respect to the AGC control signal from system operators. Consequently, the reliability improvement with DERs providing reliable frequency regulation services can be evaluated from a comprehensive perspective considering all the dynamics of communication and power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Radon monitoring and early low background counting at the Sanford Underground Laboratory

Radon detectors have been deployed underground at the Sanford Underground Laboratory at the site of the former Homestake Mine in Lead, SD. Currently, no radon mitigation measures are in place in the underground environment, and the continuing evolution of the facility ventilation systems has led to significant variations in early airborne radon concentrations. The average radon concentration measured near the primary ventilation intake for the 4850-ft level (Yates shaft) is 391 Bq/m{sup 3}, based on approximately 146 days of data. The corresponding average radon concentration near the other main ventilation intake for the 4850-ft level (Ross shaft) is 440 Bq/m{sup 3} based on approximately 350 days of data. Measurements have also been collected near the 1250-ft level Ross shaft, with average radon concentrations at 180 Bq/m{sup 3}. Secondary factors that may increase the baseline radon level underground include the presence of iron oxide and moisture, which are known to enhance radon emanation. The results of the current radon monitoring program will be used for the planning of future measurements and any potential optimization of ventilation parameters for the reduction of radon in relevant areas underground.

54 ENVIRONMENTAL SCIENCES↗

Power Hardware-in-the-Loop Interfaces for Inverter-Based Microgrid Experiments Including Transitions: Preprint

Microgrids continue to proliferate, particularly those that rely on inverter-based resources as the microgrid's voltage and frequency leader. Hardware-in-the-loop (HIL) simulations can de-risk microgrid deployments, and therefore we need power-hardware-in-the-loop (PHIL) interfaces for grid-forming (GFM) inverters to enable simulations of seamless transitions between islanded and grid-connected operation. Such microgrid interfaces are particularly challenging to model when the inverters need to switch modes, i.e., between grid-following (GFL) and GFM as the microgrid transitions between grid-connected and islanded operation. This paper presents two PHIL interfaces for such microgrids and the preliminary experimental results: One interface is suitable for those who have access to a power amplifier that can operate as a controllable current source, and the other is for those who need a solution that uses a voltage-mode power amplifier.

battery energy storage system↗

On-Line Monitoring and Real-Time Characterization of Low Level Waste and Off-Gas Condensate Samples using Raman Spectroscopy - 19274

The demand for Hanford waste property analysis is expected to significantly increase as the U.S. Department of Energy River Protection Project progresses toward transferring waste to the Hanford Waste Treatment and Immobilization Plant. The analysis of waste includes chemical, radionuclide, and physical property characterizations, with the goal of achieving safe/informed transfer and processing. Waste sampling followed by offline laboratory analysis is the current baseline analytical approach. The addition of field-deployed/in situ instruments has the potential to provide improvements and benefits over offline analysis in the areas of 1) Worker Safety: by reducing the need for sampling and thereby reducing the need for worker interaction with waste during sample handling; 2) Operational Efficiency: by reducing analysis turnaround times and offsetting demand on analytical laboratories; and 3) Accuracy: continuous analysis of a flowing waste stream allows cumulative results to be produced for the batch, which is more representative than discrete samples of batch properties. This paper describes the development and application of an online monitor to provide chemical characterizations; specifically, Raman spectroscopy is utilized to identify and quantify tank components. Accurate quantification is achieved through the use of chemometric analysis, which can be configured to provide real-time analysis in field deployment settings. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reliability of emergency and standby diesel generators: Impact on energy resiliency solutions

Emergency diesel generators are the most common form of backup power for critical loads when the grid fails and are most often deployed as stand-alone generators (<2000 kW) tied to individual buildings for hospitals, emergency services, military bases, ports, airports, industries, and commercial facilities. Understanding the finite reliability of emergency diesel generators during continuous operation is critical for energy planners, managers, and end-users. A new analysis of two large non-public emergency diesel generator operational data sets shows that commonly used reliability metrics are inadequate to predict the performance during a grid outage. Additional metrics addressing the likelihood of an emergency diesel generator to be available at the time an outage starts, successfully start and carry load, and constantly run for the duration of the outage are needed to predict the continuous run-time reliability of emergency diesel generators during a grid outage. This is the first analysis of the reliability of modern generators that follow standard maintenance protocols commonly used for backup power and these new metrics are shown to be dependent on the level of emergency diesel generator maintenance with values that can vary by more than an order of magnitude. Even using the new metrics for well-maintained emergency diesel generators, the analysis shows that the single emergency diesel generators configurations are only 80% likely to provide power for the duration of a two-week grid outage.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

The Economic Impacts of High Wind Penetration Scenarios in the United States

The U.S. electric sector is experiencing rapid increases in renewable generation with an expectation of continued growth. We examine the impacts of increased wind electricity on the U.S. economy using a hybrid model that links a detailed electric sector model (the National Renewable Energy Laboratory's Regional Energy Deployment System [ReEDS]) with a computable general equilibrium model of the U.S. economy (the Massachusetts Institute of Technology's U.S. Regional Energy Policy [USREP] model). Increasing wind capacity displaces fossil fuels for electricity generation, which depresses fossil fuel prices and reduces economy-wide CO 2 emissions. Competitive wind deployment in the reference scenario achieves these outcomes with lower electricity prices than a scenario with wind capacity fixed at 2016 levels. Lower fossil fuel and electricity prices benefit low-income households, but the dominant economic impacts are driven by increased electric sector investment and capital returns, which primarily benefit those with higher incomes. Overall, cost-competitive wind provides benefits to the U.S. economy that are initially low but rise beyond 2030 to achieve cumulative welfare and GDP improvements of $110 and $111 billion through 2050. Prescribing additional wind deployment (meeting 35% of demand by 2050) increases post-2030 electricity prices but not more so than keeping wind capacity fixed at 2016 levels. The negative effect of higher prices on welfare, however, is outweighed by higher returns from the additional wind investment. While these changes favor higher income classes, we find economy-wide benefits through 2040. These benefits diminish by 2050, but the cumulative additional gains through 2050, beyond the reference case, are $192 billion in welfare and $150 billion in GDP.

17 WIND ENERGY↗

An assessment of U.S. rare earth availability for supporting U.S. wind energy growth targets

Global initiatives are focused on deploying clean energy technologies that decrease greenhouse gas emissions. However, many of these technologies rely heavily on a volatile rare earth element (REE) supply chain. In 2016, the global supply of these REEs continues to be concentrated within a small number of countries while clean energy demand continues to grow. To address the critical nature of these REEs, global efforts have been made to diversify supply of REEs. However, it is unclear if the success of these efforts, combined with the most-promising domestic REO production capacity, will be enough to ensure REE supply for domestic clean energy technology demand, including wind energy. We apply a static and dynamic approach to estimate U.S. REE production capacity and its associated effect on U.S. wind energy growth out to 2030. Our static approach shows that U.S. light REE supply from the Mountain Pass, Bear Lodge and potential Phosphate mines operating at maximum production capacity could provide significant light REE supply to satisfy U.S. targets for wind energy REE consumption. Furthermore, when we consider market dynamics, domestic light REE production is inadequate for alleviating the supply constraint which limits overall U.S. wind energy growth out to 2030.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

TESTING OF THE DUAL ROTARY FILTER SYSTEM

The Savannah River National Laboratory (SRNL) installed and tested two hydraulically connected SpinTek rotary microfilter (RMF) units to determine the behavior of a multiple filter system. Both units were successfully controlled by a control scheme written in DELTA-V architecture by Savannah River Remediation (SRR) Process Control Engineering personnel. The control system was tuned to provide satisfactory response to changing conditions during the operation of the multi-filter system. Stability was maintained through the startup and shutdown of one of the filter units while the second was still in operation. The installation configuration originally proposed by the Small Colum Ion Exchange (SCIX) project of independent filter and motor mountings may be susceptible to vibration. Significant stiffening of the filter and motor mounts was required to minimize the vibration. Alignment of the motor to the filter was a challenge in this test configuration. The deployment configuration must be easy to manipulate and allow for fine adjustment. An analysis of the vibration signature of the test system identified critical speeds. Whether it corresponds to the resonance frequency of a rotor radial vibration mode that was excited by rotor unbalance is uncertain based upon the measurements. A relative motion series should be completed on the filter with the final shaft configuration to determine if the resonances exist in the final filter design. The instrumentation selected for deployment, including the concentrate discharge control valve and flow meters, performed well. Automation of the valve control integrated well with the control scheme and when used in concert with the other control variables, allowed automated control of the dual RMF system. The one area of concern with the instrumentation was the condition resulting when the filtrate flow meter operated with less than three gpm. This low flow was at the lower range of performance for the flow meter. This should not be an issue in deployment where the desired flow rate will be within the normal operating range of the meter. Testing demonstrated that the use of a flexible line for the filtrate discharge is highly desired at the outlet of the rotary union to transition to the system piping. Isolating the vibration from the rotary union will significantly improve the lifetime of the seals. Methods to monitor and isolate individual filters should be considered during deployment. The ability to diagnose issues and isolate individual filters would allow isolation prior to failure. Thus, filters may be cleaned or repaired instead of requiring complete replacement if the condition were to continue unnoticed. Isolating the filtrate line of each filter during startup will minimize the premature buildup of solids on the filter disks. Several tests have shown that the method of filter startup can improve performance lifetime of the filters. The installation must factor in an air inlet for the draining of a filter that does not involve a reverse flow through the filter disks. The reverse flow may cause deformation of the disks or may damage other components of the filters themselves.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Automated Mobility District Implementation Catalog, 2nd Edition: Safe and Efficient Automated Vehicle Fleet Operations for Public Mobility

This second volume of the Automated Mobility District (AMD) Implementation Catalog series has been prepared in three parts to assist readers in their review and understanding of the technical information herein. The material may be more easily ingested if each of the three parts is read and then contemplated for its ramifications to the specific interest of the reader before continuing to the next part. Further, each part has been prepared with the intent that it could be read independently from the others. Part 1 is Progress of Automated Vehicle R&D for Deployments in Passenger Service; Part 2 is 10 Early Deployment Sites as Prototypes of AMD Implementation; Part 3 is Five Cardinal Principles for AMD Implementation.

33 ADVANCED PROPULSION SYSTEMS↗

Addressing Electric Aviation Infrastructure Cybersecurity Implementation

This technical report evaluates key considerations of cybersecurity systems in preparation for the electrification of both legacy and new aviation services. The objectives are to consider the landscape of components and interconnections, review sensitivities and the criticality of data and operations, and aim to understand the applicability of existing best practices or the need for new ones associated with the cybersecurity of electric charging systems for the aviation sector. Given the early stages of electric aviation deployment, developers have the opportunity to plan and integrate cybersecurity strategies into the complete electric aviation system during the initial stages of design and procurement and will benefit from employing a framework for continuous cybersecurity monitoring. This paper presents initial considerations of key cybersecurity strategies and their application to forthcoming electric aviation systems.

airports↗

Demonstration of the Blending of the H-Canyon 2nd U Cycle with Natural U to Produce a HALEU Solution

Continued growth in the demand for high assay low enriched uranium (HALEU) is projected to support the conversion of US high performance research reactors from high to low enrichment and the development and deployment of a new generation of advanced reactors. Current options to meet the growing US need for HALEU include (1) blend-down of excess of highly enriched uranium (HEU) from the nuclear weapons programs, (2) blend-down of HEU metal from other stockpiles, or (3) recycle of irradiated HEU recovered from spent nuclear fuel (SNF). The recycle of HEU from SNF has been performed at the Savannah River Site (SRS) H-Canyon facility for nearly two decades to produce 4.95 wt % U-235 for sale and subsequent use in fuel for Tennessee Valley Authority (TVA) reactors. The HALEU produced in H-Canyon will not exceed the U-236 concentration limit in the ASTM C1462 standard for U metal enriched to more than 15% and less than 20% U-235, which applies to advanced reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High Performance Solvent for NGCC Flue Gas CO 2 Capture (Final Technical Report)

Amine-based solvent absorption is the most mature and reliable technology for large scale CO 2 capture, dating back to the 1930s when monoethanolamine (MEA) was used to treat acid gases from oil refineries. However, while strategic advancements have optimized the CO2 capture process, the cost of capture remains high, where current estimates suggest that CO 2 capture costs are around $\$$72/tonne of CO 2 . To address this, solvent development and optimization have become a focus of current research. This project sought to develop a high-performance solvent to reduce the overall cost of CO 2 capture from NGCC flue gas. Here, solvent optimization focused on: (1) reducing the energy required for CO 2 desorption in a reboiler, (2) improving CO 2 absorption and desorption reaction kinetics, (3) improving solvent stability, and (4) reducing environmental impacts. Susteon has developed and evaluated a promoted solvent, Sustenol™, for NGCC flue gas CO 2 capture. The optimized Sustenol™ also shows a higher dynamic CO 2 absorption capacity of ~0.5 mol CO2 /mol amine compared to 0.25 mol CO2 /mol amine for 30 wt% MEA. Additionally, the solvent is oxidatively, thermally and hydrothermally stable, which leads to lower solvent loss and emissions. These advancements have resulted in a solvent regeneration energy of 2.16 GJ/tonne of CO 2 which is >30% lower than current state-of-the-art commercial and emerging solvents. Combined with empirical data from the bench and pilot scale testing, this preliminary TEA study indicated the cost of CO 2 capture by Sustenol™ for 97% CO 2 removal at $\$$54/tonne and for 90% removal at $\$$49/tonne, with a pathway to achieve $\$$45/tonne of CO 2 with continued process and solvent advancements. Susteon has developed a technology roadmap to reduce the cost of CO 2 capture to <$\$$45/tonne for NGCC flue gas. Susteon plans to derisk this technology for commercial deployment through comprehensive solvent degradation testing, long-term testing in a pilot plant at 5 tonne CO2 /day and demonstration scale testing at 100 tonne CO2 /day with NGCC flue gas and engineering design studies to qualify Sustenol™ as a drop-in replacement solvent.

03 NATURAL GAS↗

Digital camera imagery for vegetation phenology, Seward Peninsula, Alaska, 2019-2021

Time lapse camera images from Kougarok mile marker (MM) 64 and Teller MM 27 NGEE-Arctic field sites on the Seward Peninsula, Alaska, captured from July 2019 to August 2021. Thirty three Wingscape Timelapse Pro cameras were deployed targeting patches of low and tall shrubs (including Alnus sp. and Salix sp.) and general vegetation and landscape views. Images from were recorded at hourly intervals from 11 AM to 2 PM, continuously for 25 months and capture vegetation phenology, snow accumulation and snow melt events. This data package includes images (*.jpg), organized by site and camera ID, and metadata with details of the cameras used, number of images recorded, start and end dates, GPS locations and example fields of view. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Integration of facility modeling capabilities for nuclear nonproliferation analysis

Developing automated methods for data collection and analysis that can facilitate nuclearnonproliferation assessment is an important research area with significant consequences for the effective global deployment of nuclear energy. Facilitymodeling that can integrate and interpret observations collected from monitored facilities in order to ascertain their functional details will be a critical element of these methods. Although improvements are continually sought, existing facilitymodeling tools can characterize all aspects of reactor operations and the majority of nuclear fuel cycle processing steps, and include algorithms for data processing and interpretation. Assessing nonproliferation status is challenging because observations can come from many sources, including local and remote sensors that monitor facility operations, as well as open sources that provide specific business information about the monitored facilities, and can be of many different types. Although many current facility models are capable of analyzing large amounts of information, they have not been integrated in an analyst-friendly manner. This paper addresses some of these facilitymodelingcapabilities and illustrates how they could be integrated and utilized for nonproliferationanalysis. The inverse problem of inferring facility conditions based on collected observations is described, along with a proposed architecture and computer framework for utilizing facilitymodeling tools. After considering a representative sampling of key facilitymodelingcapabilities, the proposed integration framework is illustrated with several examples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

On-Line Monitoring and Real-Time Characterization of Low Level Waste and Off-Gas Condensate Samples using Raman Spectroscopy

The demand for Hanford waste property analysis is expected to significantly increase as the U.S. Department of Energy River Protection Project progresses toward transferring waste to the Hanford Waste Treatment and Immobilization Plant. The analysis of waste includes chemical, radionuclide, and physical property characterizations, with the goal of achieving safe/informed transfer and processing. Waste sampling followed by offline laboratory analysis is the current baseline analytical approach. The addition of field-deployed/in situ instruments has the potential to provide improvements and benefits over offline analysis in the areas of 1) Worker Safety: by reducing the need for sampling and thereby reducing the need for worker interaction with waste during sample handling; 2) Operational Efficiency: by reducing analysis turnaround times and offsetting demand on analytical laboratories; and 3) Accuracy: continuous analysis of a flowing waste stream allows cumulative results to be produced for the batch, which is likely to be more representative than discrete samples of batch properties. This paper describes the development and application of an online monitor to provide chemical characterizations; specifically, Raman spectroscopy is utilized to identify and quantify tank components. Accurate quantification is achieved through the use of chemometric analysis, which can be configured to provide real-time analysis in field deployment settings.

Lines, Amanda M.↗

Activating Opportunity Zones for Rapid Solar+Storage Deployment in Low Income Communities (Final Report)

Millions of Texans choose their own power provider, giving them the option to have low-cost and even renewable energy delivered through their retail electric plan. However, Texans with less disposable income often pay more for electricity and have limited access to green energy and emergency backup power even though the costs of solar and wind power are at record lows and continue to decline. The Powered for Good initiative aimed to help deliver clean, affordable, 100% renewable electricity to low-income households in Texas’s Competitive Retail Areas, where households can choose their electricity provider. Objectives: The primary goal of this project was to develop and validate one or more affordable solar+storage products (i.e., priced less than of $0.14/kWh) that Retail Electricity Providers (REP) can offer to LI households. The team achieved three objectives: 1. Investigate how to best reduce electricity costs and increase availability of emergency power for LI customers; 2. Build momentum for, and facilitate an approach to, a Texas-based pilot deployment of such solar+storage products, with a goal of greatly expanding this approach to a large segment of the LI population in Texas; 3. Provide the structural framework, finance model, and roadmap to potentially increase investment of solar+storage projects in LI communities across U.S. states when modified to meet their state-specific laws and regulations. The team evaluated the market of viable solutions for low-income Texans through interviews and focus groups with professionals and residents with lived experience. The team then piloted a low-cost retail electric product. Following the pilot, the team developed educational materials, including fact sheets, a Go Green Save Green interactive guide, and an Electricity Bill Analysis Tool. The team is now working to increase power resilience and reduce energy insecurity with micro solar and storage in partnership with local entities in the Harris County area. Key Findings: Informed by Powered for Good research, including the experiences on Texas residents and electricity system experts, the Powered for Good team developed a pilot that was implemented by Energy Well Texas, a new company formed in late 2020. The pilot featured a combination of a 100% clean residential energy offering delivered through the electrical grid plus a selection of batteries, lights and a solar panel that provided participants with varying levels of backup power. For the 8 customers who submitted previous bills, the Energy Well Texas pilot reduced energy bills by about 30%. In Houston, residents earning less than 30% of Area median Income (AMI) spend an average 13% of their income on energy or about $1,555 per year. Repeating the pilot results for these residents could yield $466 in savings per customer or about 4% of their income. While this will not end energy poverty, it is a big step toward that goal. The Powered for Good and Energy Well Texas teams are currently planning their post-pilot phase of service offerings.

14 SOLAR ENERGY↗

Aerosol Particle Mixing State and Composition at AMF3 (Interim Field Campaign Report)

The campaign is designed to support deployment of aerosol sampling equipment at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s third ARM Mobile Facility (AMF3) to enable both singe-particle and bulk characterization of the aerosol particles at the field site in Bankhead National Forest, northern Alabama. We are proposing to do this work as part of our proposal “Generalizing aerosol mixing state: synthesis from observations and connection to models,” which has the pre-proposal tracking number PRE-0000035878. The full proposal has Dr. Rachel O’Brien as the Principal Investigator (PI) and Dr. Andy Ault and Dr. Nicole Riemer as Co-PIs. We sought to deploy instruments in winter 2025 and summer 2025 to obtain samples in different seasons, but were delayed by AMF3 set-up and availability of students and PIs. We just completed our first deployment this summer (2025) and we are interested in obtaining samples during this upcoming fall and winter to see the seasonal trends in aerosol mixing state at the site. This will provide a comparison of the impact of biogenic emissions on the mixing state and the chemical composition of the aerosol particles. Overall, the proposed study will provide key information regarding the mixing state of aerosol particles at AMF3 with direct ties to impacts of the particles on cloud formation and light scattering/absorption. From our deployment that ended las week we have some visible observations from our samples. We are observing a regular amount of black carbon on stage 6 of our Micro-Orifice Uniform Deposit Impactor (MOUDI) and we have also observed some short, large increases in aerosol loading. We hope to continue observations of these two features to determine the sources/aging for the black carbon and the physical mixing state as well as the sources for the short (a few minutes) increases in the aerosol loading and determine if the source for these is dust or sea salt or another source. We are also interested in comparing the black carbon we see here to samples collected during the agriculture burns in January/February and in comparing the larger particles to bioaerosols in the spring. To obtain these comparisons, we will need to collect more samples in the other seasons. Finally, we have some size-resolved particle collectors that can be deployed at the same time as the tethered balloon launches. We have discussed with Swarup China about trying to get the timing to work in August and we are interested in coordinating again later, if possible. This will give us ground-level and vertical aerosol mixing state sample sets that will be very exciting to analyze.

54 ENVIRONMENTAL SCIENCES↗

Dish systems for CSP

Parabolic dish technology, for concentrating solar power (CSP) applications, has been continuously modified and improved since the pioneering work in the 1970s. Best practice dishes now have features such as lightweight structure, balanced design, high-quality, low-cost mirror panels, and can be deployed rapidly with little in-field labour. This review focuses on the evolution of dish design, by examining features such as mode of tracking, structure and mirror design, for a wide selection of CSP dish examples. Finally, the review includes a brief summary of power generation options – both on-dish and central plant – as well as a discussion about options for storage and hybridisation.