A New Integrated Onboard Charger and Accessory Power Converter for Plug-in Electric Vehicles

In this paper, a new approach is presented for integrating the function of onboard battery charging into the traction drive system and accessory dc-dc converter of a plug-in electric vehicle (PEV). The idea is to utilize the segmented traction drive system of a PEV as the frond converter of the charging circuit and the transformer and high voltage converter of the 14 V accessory dc-dc converter to form a galvanically isolated onboard charger. Moreover, a control method is presented for suppressing the battery current ripple component of twice the grid frequency with the reduced dc bus capacitor in the segmented inverter. The resultant integrated charger has lower cost, weight, and volume than a standalone charger due to a substantially reduced component count. The proposed integrated charger topology was verified by modeling and experimental results on a 5.8 kW charger prototype.

Su, Gui-Jia↗

Synthetic, Realistic Transmission and Distribution Co-Simulation for Voltage Control Benchmarking: Preprint

As distributed energy resources play an increasing role in generation and grid services, control and market paradigms will need to be tested with models that incorporate transmission and distribution systems. The test systems will need to be realistic and accessible for researchers to form conclusions about realistic behaviors and maintain comparability and repeatability of results. These test systems also must have high resolution models of sufficient size for realistic distribution and transmission interaction. This paper demonstrates the tightly coupled co-simulation of realistic synthetic distribution and transmission models for the Austin metropolitan area and how this framework can be used to analyze resultant behaviors from distributed resources and their controls. The comparison of a distribution system run with fixed feed-in voltage is compared to the closely tied distribution-transmission co-simulation. It is determined that even without advanced voltage controls, the feed-in voltage response of the transmission system shows a lower level of voltage excursions. Therefore, control methods for voltage stability should be benchmarked on realistic transmission and distribution co-simulations for more accurate assessment of voltage profiles.

27 ARPA - Advanced Research Projects Agency-Energy↗

Systems and methods for cylinder deactivation in dedicated EGR engine

Systems, apparatus, and methods are disclosed that include a divided exhaust engine with at least one primary exhaust gas recirculation (EGR) cylinder and a plurality of non-primary EGR cylinders. The systems, apparatus and methods control the EGR fraction by deactivation of one or more of the cylinders.

Desai, Akash S.↗

DERMS Online: A New Voltage Sensitivity-Enabled Feedback Optimization Framework: Preprint

This paper proposes a distributed energy resource management system (DERMS) solution by developing a new voltage sensitivity enabled feedback optimization framework. The key idea is to adopt a measurement feedback scheme to reformulate the original nonlinear optimization into a linear programming (LP) problem via perturb and observe-based voltage sensitivity analysis. The proposed solution eliminates the dependence on load knowledge and can be implemented online thanks to an efficient open-source solver for LP problems. The proposed DERMS online platform is generalizable to deal with various types of distributed energy resources (DERs), including distributed photovoltaics (PVs), energy storage, electric vehicles, demand response, etc. Comparison results with other control methods on a realistic distribution feeder in Southern California highlight the feasibility as well as benefits for the proposed framework.

distributed energy resources management↗

Soft Actor Critic Based Volt-VAR Co-optimization in Active Distribution Grids

Modern distribution networks are undergoing several technical challenges, such as voltage fluctuations, because of high penetration of distributed energy resources (DERs). This paper proposes a deep reinforcement learning (DRL)-based Volt VAR co-optimization technique for reducing voltage fluctuations as well as power loss under high penetration of DERs. In addition, the proposed approach minimizes the operational cost of the grid. A stochastic policy optimization based soft actor critic (SAC) agent is proposed to configure the optimal set-points of the reactive power outputs of the inverters. The performance of the proposed model is verified on the modified IEEE 34- and 123-bus systems and compared with a base case scenario with no reactive supply by inverters, and a local droop control approach. The results demonstrate that the proposed framework outperforms the conventional droop control method in improving the voltage profile, minimizing the network power loss, and reducing grid operational cost.

—Distribution grids, deep reinforcement learning, ↗

NMPC for Setpoint Tracking Operation of a Solid Oxide Electrolysis Cell System

Solid oxide electrolysis cells (SOECs) are a promising technology to generate hydrogen through water electrolysis. However, intermittent renewable energy requires SOECs to transition between hydrogen production setpoints as the price of electricity fluctuates. A well-functioning control system is important to avoid cell degradation during setpoint tracking operation. In this work, we apply nonlinear model predictive control (NMPC) to an SOEC module and supporting equipment and compare NMPC performance to classical PI control while ramping between hydrogen production setpoints. We find that these control methods provide similar performance in many metrics, but NMPC significantly reduces cell thermal gradients during the setpoint transition.

Allan, Douglas↗

Two-Stage Deep Reinforcement Learning for Distribution System Voltage Regulation and Peak Load Management: Preprint

The growing integration of distributed solar photovoltaic (PV) in distribution systems could result in adverse effects during grid operation. This paper develops a soft actor critic-based deep reinforcement learning (SAC-DRL) solution to simultaneously control PV inverters and battery energy storage systems for voltage regulation and peak load demand shaving. The novel two-stage framework, featured with two different control agents, is applied for daytime and nighttime operation to enhance the control performance. Comparison results with other control methods on a real feeder in Western Colorado demonstrate that the proposed method can provide advanced voltage regulation with modest active power curtailment for peak demand reduction.

deep reinforcement learning↗

Electrochemical polymer pen lithography

Disclosed herein is a massively parallel patterning tool for the deposition of single metals or metal alloys with size and composition control. Methods of the disclosure use a hydrogel array of pyramidal pen tips as a medium for localized electrodeposition, in conjunction with a scanning probe lithography platform and a three-electrode cell. This versatile technique can be used for high-throughput 3D printing, biomolecule patterning, or screening of catalyst nanoparticles or thin films.

Mirkin, Chad A.↗

Guide to specifying a powered manipulator for operation in hazardous environments - 15510

Manipulators have been used extensively to perform remote nuclear operations, handle hazardous materials and perform decommissioning activities. As payload and reach requirements increase, manually powered tooling options are often under-powered, or too delicate to perform. When this occurs powered manipulators are often used to meet the need. Powered manipulator types commonly used are electro-mechanically powered and hydraulically powered manipulators. A number of factors will need to be weighed in order to determine the type of manipulator that best meets the needs of the application. While there is not a single manipulator type that is best suited for all applications each type has its own strengths and weaknesses. The challenge to the site operator is to determine the most effective solution for the job at hand. Operating envelope, installation methods, control system, payload, radiation levels and failure modes are some of the most important requirements to consider. Regardless of the manipulator type chosen the most economical solution is often a customized pre-engineered solution. Existing, proven designs can often be modified slightly to meet the unique needs of a project. Often times it is not possible to meet requirements with a pre-engineered solution and a custom solution must be created. Even with a custom design standard design elements can often be used to decrease cost, increase reliability and improve performance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of Cold Spraying Mild-Steel Powder onto Mild-Steel Substrate for Development of Waste Tank Repair System - 20515

Infrastructure for nuclear waste storage and processing (e.g., waste tanks, transfer pipelines, evaporators) at the U.S. Department of Energy (DOE) Hanford Site has been in service well beyond its original design life. Past corrosion control methods at Hanford for waste tanks have not been fully successful, as evidenced by leaks forming in tank AY-102, the first double-shell tank (DST) constructed, and significant degradation detected in the primary tanks of AP-102 and AY-101. Failure of infrastructure components can pose a significant risk to the environment, worker safety, and project schedules. Therefore, remotely deployable methods for repairing and extending the service life of the existing tank waste infrastructure are needed. Cold spray has been identified as a potential technique for performing in situ repairs and material buildup for life extension of waste storage and processing infrastructure. Cold-spray repair methods and technology are well-established and are used extensively by industry and the military for making repairs using dissimilar materials. Pacific Northwest National Laboratory is evaluating the process of making repairs using mild-steel powder applied to a mild-steel substrate to minimize the galvanic corrosion potential. This paper presents the initial results for a feasibility ('go/no-go') assessment as to whether low-density deposits with sound metallurgic bonds, to build-back steel plate material, can be achieved using existing commercial cold-spray equipment. An assessment of steel-on-steel deposit is necessary to determine if cold spray is a viable candidate for DST carbon steel plate restoration/repair and thus DST service life extension. Powder properties and preparation requirements have been investigated and operating conditions and parameters for depositing a cold-spray buildup of mild steel on a mild-steel substrate have been determined. Soundness of metallurgic bonding as a function of the operating parameters exercised and results from applying cold spray to lay a deposit over simulated small-diameter flaws in 1/2-inch mild-steel plate are presented. Application of in situ cold-spray repair to the DOE complex has the potential to reduce cost and schedule impacts associated with component failures and the need to procure and construct replacement infrastructure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Atalante research facility new mass limits in a unit containing plutonium and minor actinides - 14402

ATALANTE, located in Marcoule, is one of the main Nuclear Facilities of the French Alternative Energies and Atomic Energy Commission (CEA). This facility is mainly dedicated to research and development for nuclear energy related to the back end of the fuel cycle: spent fuel and final waste management. It is a large research complex housing chemistry and analytical laboratories and shielded cells (240 glove boxes and 11 shielded cells), equipped for basic studies through to demonstration experiments. Within the facility, one unit can contain plutonium and curium at the same time. In this case, nuclear criticality safety is achieved by exercising control over mass. A subcritical mass limit is defined for plutonium (280 g for {sup 239}Pu) and an exemption mass limit (3 g for {sup 245}Cm) is used for the actinide. In order to increase the maximum mass (in particular {sup 245}Cm) which can be handled in the unit, new mass control limits were studied, based on control over the sum of the mass ratio to the upper subcritical mass, noted m{sub lim}, for each nuclide (350 g for {sup 239}Pu; 34.8 g or 23 g for {sup 245}Cm) as shown in equation (1) below. m({sup 239}Pu)/ m{sub lim}({sup 239}Pu)+ m({sup 245}Cm)/m{sub lim}({sup 245}Cm)≤1 (1) To validate this criticality safety control method, a study was conducted to demonstrate that, for different masses of {sup 239}Pu and {sup 245}Cm meeting equation (1), the calculated effective multiplication factor is always lower than the effective multiplication factor corresponding to a sphere of 350 g of pure {sup 239}Pu, moderated, with 20 cm water reflection. The two pseudo fissile media are: - metallic plutonium (100% {sup 239}Pu, density 19.86), moderated with water, - metallic curium (100% {sup 245}Cm, density 13.566), moderated with water. The calculation model is a sphere of {sup 245}Cm metal positioned in a sphere of {sup 239}Pu metal, with optimum moderation for each fissile material, and a full water reflection (20 cm). The results show that, under certain conditions, the effective multiplication factor of the mixture can be higher than the effective multiplication factor of each pure fissile material when using the upper subcritical mass of 34.8 g for {sup 245}Cm. When using 23 g of {sup 245}Cm, the k{sub eff} of the mixture is always lower than the k{sub eff} of pure {sup 239}Pu. These calculations enable the safety documentation to be changed by introducing a new process operational procedure, based on equation (1). This change in procedure allows the operator to work with a larger quantity of curium in the unit. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Examining the Feasibility of Identifying Tau Neutrino Charged Current Events in the DUNE Far Detector

Neutrinos began as theoretical, massless particles, and since their first detection they have continued to be the subject of various experiments. One such experiment is DUNE, which is a long baseline neutrino experiment with the goal of studying neutrino properties, such as neutrino oscillation parameters. In this work, two projects were completed, one dealing with the hardware of DUNE and the other dealing with neutrino simulations. For the hardware project, we designed a quality control method for testing adaptor boards which make up part of the Far Detector circuit boards. This method was completed and prototyped, however was not implemented as planned due to funding changes. For the simulation project, we simulated ντ , νµ, and νe CC interactions using two simulation methods (stand alone GENIE and a full detector simulation) in order to begin to understand what a ντ CC event would look like in the Far Detector and create an initial list of kinematic properties that can be used for this purpose. We found that there is not a complete understanding of what is occurring in the full detector simulation. We also found that there is promise in using kinematic properties to be able to differentiate ντ CC events, however properties beyond those covered here, as well as a more accurate simulation, will be required for any definitive statistical statements.

Choate, Sarah↗

Reinforcement Learning to Enhance Optimal Operation of Resilient Community Energy Systems

This paper presents a novel model-free multi-agent Reinforcement Learning (RL) control method to enhance the resilience of community energy systems in island mode, which coordinates multiple objectives without the necessity of identifying system models that require expert knowledge. Specifically, a community-level coordinator agent is designed to allocate renewable energy resources among different buildings, and multiple building-level agents are developed to optimize load schedules based on limited energy resources and requirements of building loads and occupants’ comfort. In a two-day evaluation, our RL approach demonstrated a similar performance against MPC without requiring system models and formulation of optimization problems as required in MPC.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Dynamic Simulation Modeling and Control of a Desiccant Assisted Direct-expansion Air Handling Unit

Desirable built environments demand simultaneous regulation of thermal comfort and indoor air quality (IAQ) with energy-efficient operation of heating, ventilation and air conditioning (HV AC) systems, which involves controls of temperature, humidity and airborne contaminants simultaneously. This paper presents the efforts of dynamic modeling and initial development control strategy for a desiccant-assisted multi-functional air handling unit (AHU) coupled with a direct-expansion rooftop unit (RTU) system, which aims to achieve multiple functions for indoor environment conditioning with energy efficient control. The RTU-AHU system includes a desiccant wheel for dehumidification and a conceptual direct air capture (DAC) filtering device for CO2 regulation. A Modelica-based dynamic model is developed for this conceptual system, and a simple decentralized control strategy is designed, which combines a differential-enthalpy based AHU return-air ratio control, a demand-controlled ventilation, and supply-air temperature humidity control via the RTU and DW controls. The proposed control method is evaluated with the Modelica simulation model for a selected set of scenarios

Pan, Chao↗

LOCO with Constraints and Improved Fitting Technique

LOCO has been a powerful beam-based diagnostics and optics control method for storage rings and synchrotrons worldwide ever since it was established at NSLS by J. Safranek. This method measures the orbit response matrix and optionally the dispersion function of the machine. The data are then fitted to a lattice model by adjusting parameters such as quadrupole and skew quadrupole strengths in the model, BPM gains and rolls, corrector gains and rolls of the measurement system. Any abnormality of the machine that affects the machine optics can then be identified. The resulting lattice model is equivalent to the real machine lattice as seen by the BPMs. Since there are usually two or more BPMs per betatron period in modern circular accelerators, the model is often a very accurate representation of the real machine. According to the fitting result, one can correct the machine lattice to the design lattice by changing the quadrupole and skew quadrupole strengths. LOCO is so important that it is routinely performed at many electron storage rings to guarantee machine performance, especially after the Matlab-based LOCO code became available. However, for some machines, LOCO is not easy to carry out. In some cases, LOCO fitting converges to an unrealistic solution with large changes to the quadrupole strengths {Delta}K. The quadrupole gradient changes can be so large that the resulting lattice model fails to find a closed orbit and subsequent iterations become impossible. In cases when LOCO converges, the solution can have {Delta}K that is larger than realistic and often along with a spurious zigzag pattern between adjacent quadrupoles. This degeneracy behavior of LOCO is due to the correlation between the fitting parameters - usually between neighboring quadrupoles. The fitting scheme is therefore less restrictive over certain patterns of changes to these quadrupoles with which the correlated quadrupoles fight each other and the net effect is very inefficient {chi}{sup 2} reduction, i.e., small {chi}{sup 2} reduction with large changes of {Delta}K. Under effects of random noise, the fitting solution tends to crawl toward these patterns and ends up with unrealistically large {Delta}K. Such a solution is not very useful in optics correction because after the solution is dialed in, the quadrupoles will not respond as predicted by the lattice model due to magnet hysteresis. We will show that adding constraints to the fitting parameters is an effective way to combat this problem of LOCO. In fact, it improves optics calibration precision even for machines that don't show severe degeneracy behavior. LOCO fitting is essentially to solve a nonlinear least square problem with an iterative approach. The linear least square technique is applied in each iteration to move the solution toward the minimum. This approach is commonly referred to as the Gauss-Newton method. By using singular value decomposition (SVD) to invert the Jacobian matrix, this method has generally been very successful for LOCO. However, this method is based on a linear expansion of the residual vector over the fitting parameters which is valid only when the starting solution is sufficiently close to the real minimum. The fitting algorithm can have difficulties to converge when the initial guess is too far off. For example, it's possible for the {chi}{sup 2} merit function to increase after an iteration instead of decrease. This situation can be improved by using more robust nonlinear least square fitting algorithms, such as the Levenberg-Marquardt method. We will discuss the degeneracy problem in section 2 and then show how the constrained fitting can help in section 3. The application of Levenberg-Marquadt method to LOCO is shown in section 4. A summary is given in section 5.

43 PARTICLE ACCELERATORS↗

Combining model-based and model-free methods for stochastic control of distributed energy resources

Modern distribution systems are experiencing a fast transformation with the growing penetration of distributed energy resources (DERs). Along with the economic and environmental benefits of DERs, challenges arise to address the uncertainties caused by their inherent volatility. If properly coordinated, however, DERs have the potential to provide the controllability that grid operators need. Here, we propose a hierarchical control framework that combines the model-based and model-free methods for stochastic DER control in distribution systems. The upper-level scheduler considers a chance-constrained optimal power flow problem (model-based) that schedules DER setpoints to minimize the operational cost and maintain the operating reserve. The lower-level distributed DER controllers absorb real-time disturbances and uncertainties using the extremum seeking control (model-free) to achieve grid objectives. The combination of model-based and model-free methods allows us to take the advantages of both methods to effectively manage the uncertainty in distribution systems. The proposed work is demonstrated on the IEEE 13-node feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Developing a Control Strategy for Minimum Airflow Setting Considering CO2 Level and Energy Consumption in a Variable Air Volume System

In an office building equipped with a Variable Air Volume (VAV) system, this paper introduces a novel method for controlling the minimum supply airflow fraction in each zone’s VAV box, having a capability to consider indoor CO2 level and energy consumption. The EnergyPlus simulation using the medium office prototype model was employed, which evaluated the performance of the energy and CO2 concentration for five VAV box airflow control strategies. The paper focuses on CO2 concentration-based airflow control method and compares it with other four methods including conventional single-max, reduced minimum single-max, demand-controlled ventilation(DCV), and dualmax control methods according to guidelines and common practices. The newly proposed control strategy directly correlates the minimum airflow fraction to CO2 concentration. A general trend emerged when comparing CO2 concentrations—lower minimum airflow fractions were associated with higher concentrations. The proposed control method effectively maintained low CO2 concentrations and enabled a lower airflow fraction contributing to energy consumption reduction. It was confirmed that heating energy consumption in climate zone 4A, 5B, and 6A showed a maximum saving of approximately 30% compared to the conventional single-max and dual max control strategies. It was found that cooling energy consumption in climate zone 4A and 6A can achieve a maximum saving of approximately 10% compared to the conventional control strategies. The proposed CO2 concentration-based control logic is promising as it not only improves the indoor air quality lowering the CO2 concentration in the occupied spaces, but also contributes to HVAC energy savings.

Lee, Jong Man↗