Search NASA⌕ Search

SEARCH · Search NASA

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Lunar Impact Basins: Stratigraphy, Sequence and Ages from Superposed Impact Crater Populations Measured from Lunar Orbiter Laser Altimeter (LOLA) Data

Impact basin formation is a fundamental process in the evolution of the Moon and records the history of impactors in the early solar system. In order to assess the stratigraphy, sequence, and ages of impact basins and the impactor population as a function of time, we have used topography from the Lunar Orbiter Laser Altimeter (LOLA) on the Lunar Reconnaissance Orbiter (LRO) to measure the superposed impact crater size-frequency distributions for 30 lunar basins (D ≥ 300 km). These data generally support the widely used Wilhelms sequence of lunar basins, although we find significantly higher densities of superposed craters on many lunar basins than derived by Wilhelms (50% higher densities). Our data also provide new insight into the timing of the transition between distinct crater populations characteristic of ancient and young lunar terrains. The transition from a lunar impact flux dominated by Population 1 to Population 2 occurred before the mid-Nectarian. This is before the end of the period of rapid cratering, and potentially before the end of the hypothesized Late Heavy Bombardment. LOLA-derived crater densities also suggest that many Pre-Nectarian basins, such as South Pole-Aitken, have been cratered to saturation equilibrium. Finally, both crater counts and stratigraphic observations based on LOLA data are applicable to specific basin stratigraphic problems of interest; for example, using these data, we suggest that Serenitatis is older than Nectaris, and Humboldtianum is younger than Crisium. Sample return missions to specific basins can anchor these measurements to a Pre-Imbrian absolute chronology.

Fassett, C. I.↗

Using the Chandra Source-Finding Algorithm to Automatically Identify Solar X-ray Bright Points

This poster details a technique of bright point identification that is used to find sources in Chandra X-ray data. The algorithm, part of a program called LEXTRCT, searches for regions of a given size that are above a minimum signal to noise ratio. The algorithm allows selected pixels to be excluded from the source-finding, thus allowing exclusion of saturated pixels (from flares and/or active regions). For Chandra data the noise is determined by photon counting statistics, whereas solar telescopes typically integrate a flux. Thus the calculated signal-to-noise ratio is incorrect, but we find we can scale the number to get reasonable results. For example, Nakakubo and Hara (1998) find 297 bright points in a September 11, 1996 Yohkoh image; with judicious selection of signal-to-noise ratio, our algorithm finds 300 sources. To further assess the efficacy of the algorithm, we analyze a SOHO/EIT image (195 Angstroms) and compare results with those published in the literature (McIntosh and Gurman, 2005). Finally, we analyze three sets of data from Hinode, representing different parts of the decline to minimum of the solar cycle.

Adams, Mitzi L.↗

Real-time data processing for serial crystallography experiments

We report the use of streaming data interfaces to perform fully online data processing for serial crystallography experiments, without storing intermediate data on disk. The system produces Bragg reflection intensity measurements suitable for scaling and merging, with a latency of less than 1 s per frame. Our system uses the CrystFEL software in combination with the ASAP::O data framework. In a series of user experiments at PETRA III, frames from a 16 megapixel Dectris EIGER2 X detector were searched for peaks, indexed and integrated at the maximum full-frame readout speed of 133 frames per second. The computational resources required depend on various factors, most significantly the fraction of non-blank frames ('hits'). The average single-thread processing time per frame was 242 ms for blank frames and 455 ms for hits, meaning that a single 96-core computing node was sufficient to keep up with the data, with ample headroom for unexpected throughput reductions. Further significant improvements are expected, for example by binning pixel intensities together to reduce the pixel count. We discuss the implications of real-time data processing on the `data deluge' problem from recent and future photon-science experiments, in particular on calibration requirements, computing access patterns and the need for the preservation of raw data.

47 OTHER INSTRUMENTATION↗

LLNL International Working Group on Gamma Spectrometry - Preparation of IDB Dataset

The spectral information and associated metadata, including source information, detector setup, and shielding configuration is described in human readable, comma-separated text files (csv). Five csv files are associated with each material type and include the following information (where [Isotope] is U, Pu, and MOX): [Isotope]_measurement_metadata - Metadata of the measurement configuration, including material composition at time of acquisition (decay corrected from certificate date). Data that is unique to a measurement configuration e.g. detector geometry, source-detector distance, analyzer and other electronics used, attenuating materials are provided in this file. [Isotope]_spectrum_metadata - The information that is unique to the spectrum. This includes detector specifications (e.g. date of acquisition, number of channels, gain (keV/channel), energy range, real and live time, full width half-maximum (FWHM) of the 186 or 208 peak for uranium or plutonium measurements, respectively. [Isotope]_source_metadata - The source material used for the measurement, this includes the ratio and uncertainties of isotopes present and processing information of the material. In addition, the certificate information for the source material is listed. [Isotope]_spectrum_counts_metadata - The counts per channel for each spectrum. This data is linked via the UID.spectrum index to the measurement_metadata file. [Isotope]_spectrum_checksum_metadata The MD5 checksum for the original spectrum file. This data is linked via the UID.spectrum index to the measurement_metadata file. This information is provided to prevent duplication of entries in the database.

42 ENGINEERING↗

LLNL International Working Group on Gamma Spectrometry - Preparation of IDB Dataset [Slides]

The spectral information and associated metadata, including source information, detector setup, and shielding configuration is described in human readable, comma-separated text files (csv). Six csv files are associated with each material type and include the following information (where [Isotope] is U, Pu, and MOX): [Isotope]_measurement_metadata Metadata of the measurement configuration, including material composition at time of acquisition (decay corrected from certificate date). Data that is unique to a measurement configuration e.g. detector geometry, source-detector distance, analyzer and other electronics used, attenuating materials are provided in this file. [Isotope]_spectrum_metadata The information that is unique to the spectrum. This includes detector specifications (e.g. date of acquisition, number of channels, gain (keV/channel), energy range, real and live time, full width half-maximum (FWHM) of the 186 or 208 peak for uranium or plutonium measurements, respectively. [Isotope]_source_metadata The source material used for the measurement, this includes the ratio and uncertainties of isotopes present and processing information of the material. In addition, the certificate information for the source material is listed. [Isotope]_spectrum_counts_metadata The counts per channel for each spectrum. This data is linked via the UID.spectrum index to the measurement_metadata file. [Isotope]_spectrum_checksum_metadata The MD5 checksum for the original spectrum file. This data is linked via the UID.spectrum index to the measurement_metadata file. This information is provided to prevent duplication of entries in the database. [Isotope]_provenance Details on the csv data provider, including laboratory and contract information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Total Measurement Uncertainty in Neutron Coincidence Multiplicity Analysis

Neutron multiplicity counting is the most commonly used nondestructive assay technique for determining the plutonium mass within containers of scrap PuO 2 or mixed oxide (MOX). In multiplicity analysis, the 240 Pu eff mass, leakage multiplication, and alpha ratio (the ratio of [α, n]-to-spontaneous fission neutron production) are the three primary unknown sample properties. They must be determined simultaneously. To solve for these three unknowns in a multiplicity assay, three measured values are needed: the singles, doubles, and triples neutron count rates. While the analysis is limited to solving for three unknowns, there are many additional factors that impact the observed count rates and contribute to the measurement uncertainty. In this study we investigate the various uncertainty contributors for the multiplicity analysis through a combination of traditional uncertainty propagation techniques supplemented by Monte Carlo simulations to address the dependences not explicitly expressed by the point source model. Uncertainties arising from counting statistics, calibration parameters, calibration method, nuclear data, and various material characteristics (isotopic abundances, chemical form, density, and impurities) are considered. A Total Measurement Uncertainty (TMU) estimate is then developed from these uncertainty contributors. This study is confined to multiplicity analysis of items commonly encountered in international safeguards applications. That is, the study focused on Pu oxides and MOX materials for the masses ranging up to 4000 grams total Pu. Multiplicity measurements were simulated using MCNP V6 based on the Plutonium Scrap Multiplicity Counter (PSMC), Epithermal Multiplicity Counter (ENMC), Pyrochemical Multiplicity Counter, and Large Epithermal Multiplicity Counter (LEMC) for this study; however, this report focuses on the parameterization of the uncertainties for the PSMC. The performance differences between the PSMC and the other multiplicity counting systems are relatively small, primarily manifesting in the impact on measurement precision so that the evaluation developed for the PSMC can be applied to the other multiplicity counting systems. Finally an analysis tool, the Multiplicity TMU Estimator, was developed from this study to serve as an aid for evaluation of the total measurement uncertainty of multiplicity assay results obtained from the commonly used INCC acquisition and analysis software.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a Photon Counting System for Differential Lidar Signal Detection

Photon counting has been chosen as a means to extend the detection range of current airborne DIAL ozone measurements. Lidar backscattered return signals from the on and off-line lasers experience a significant exponential decay. To extract further data from the decaying ozone return signals, photon counting will be used to measure the low light levels, thus extending the detection range. In this application, photon counting will extend signal measurement where the analog return signal is too weak. The current analog measurement range is limited to approximately 25 kilometers from an aircraft flying at 12 kilometers. Photon counting will be able to exceed the current measurement range so as to follow the mid-latitude model of ozone density as a function of height. This report describes the development of a photon counting system. The initial development phase begins with detailed evaluation of individual photomultiplier tubes. The PMT qualities investigated are noise count rates, single electron response peaks, voltage versus gain values, saturation effects, and output signal linearity. These evaluations are followed by analysis of two distinctive tube base gating schemes. The next phase is to construct and operate a photon counting system in a laboratory environment. The laboratory counting simulations are used to determine optimum discriminator setpoints and to continue further evaluations of PMT properties. The final step in the photon counting system evaluation process is the compiling of photon counting measurements on the existing ozone DIAL laser system.

Elsayed-Ali, Hani↗

Photon temporal-mode readout for inference of neutron star merger remnant gravitational waves

Gravitational waves emitted after neutron star binary coalescences and the information they carry about dense matter are a high-priority target for next-generation detectors. Even though such detectors are expected to observe millions of signals, detectable postmerger emission will remain rare. Here, in this work, we explore postmerger detectability and inference through an alternative detector readout scheme for data dominated by quantum-noise, which is the case above 1 kHz; photon-counting. In such a readout, signals and noise become quantized into discrete distributions corresponding to the detection of single photons measured in a chosen basis of modes. Through simulated data, we demonstrate that photon counting can be efficient even for weak signals. We find ∼1 in 100 signals with a postmerger signal-to-noise ratio of 0.2 can result in a single photon and thus be detected. Furthermore, after 2 ×10 4 signals—equivalent to 10 −2 to 1.5 years of observation—photon counting results in a twofold improvement in the measurement of the radius of a 1.6⁢𝑀 ⊙ neutron star. Constraints can be further tightened if the detector classical noise is reduced. Photon counting offers a promising alternative to traditional homodyne readout techniques for extracting information from low signal-to-noise ratio postmerger signals.

gravitational wave detection↗

Time encoded radiation imaging

The various technologies presented herein relate to detecting nuclear material at a large stand-off distance. An imaging system is presented which can detect nuclear material by utilizing time encoded imaging relating to maximum and minimum radiation particle counts rates. The imaging system is integrated with a data acquisition system that can utilize variations in photon pulse shape to discriminate between neutron and gamma-ray interactions. Modulation in the detected neutron count rates as a function of the angular orientation of the detector due to attenuation of neighboring detectors is utilized to reconstruct the neutron source distribution over 360 degrees around the imaging system. Neutrons (e.g., fast neutrons) and/or gamma-rays are incident upon scintillation material in the imager, the photons generated by the scintillation material are converted to electrical energy from which the respective neutrons/gamma rays can be determined and, accordingly, a direction to, and the location of, a radiation source identified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing Axial Symmetry Breaking in the Galaxy with Gaia Data Release 2

We study a set of solar neighborhood ($d < 3$ kpc) stars from Gaia Data Release 2 to determine azimuthal star count differences, i.e., left and right of the line from the Galactic center through the sun - and compare these differences north and south. In this companion paper to Gardner et al. (2020), we delineate our procedures to remove false asymmetries from sampling effects, incompleteness, and/or interloper populations, as this is crucial to tests of axisymmetry. Particularly, we have taken care to make appropriate selections of magnitude, color, in-plane Galactocentric radius and Galactic $|b|$ and $|z|$. We find that requiring parallax determinations of high precision induces sampling biases, so that we eschew such requirements and exclude, e.g., regions around the lines of sight to the Magellanic clouds, along with their mirror-image lines of sight, to ensure well-matched data sets. After making conservative cuts, we demonstrate the existence of azimuthal asymmetries, and find differences in those, north and south. These asymmetries give key insights into the nature and origins of the perturbations on Galactic matter, allowing us to assess the relative influence of the Magellanic Clouds (LMC & SMC), the Galactic bar, and other masses on the Galactic mass distribution, as described in Gardner et al. (2020). The asymmetry's radial dependence reveals variations that we attribute to the Galactic bar, and it changes sign at a radius of $(0.95 \pm 0.03) R_0$, with $R_0$ the Sun-Galactic-Center (GC) distance, to give us the first direct assessment of the outer Lindblad resonant radius.

79 ASTRONOMY AND ASTROPHYSICS↗

Predicting Biological Cleanliness: An Empirical Bayes Approach for Spacecraft Bioburden Accounting

To comply with the international planetary protection policy set forth by the Committee on Space Research and NASA Agency level requirements, spacecraft destined to biologically sensitive planetary bodies have to minimize terrestrial biological contamination. Analysis, testing and inspection are the standard forward verification activities that are used to demonstrate compliance with the biological contamination requirements. For testing of spacecraft surface areas, a swab or wipe sample is collected from surfaces prior to last access and subsequently processed in the lab using NASA Approved Planetary Protection Methods for Culture Based Assays. Raw data resulting from this assay is then statistically treated employing a mathematical paradigm stemming from the 1970’s Viking Lander Project to generate the bioburden density and total microbial bioburden present. This standard approach arbitrarily accounts for error and provides an upper conservative bound as it reports the maximum number of spores estimated to be present on flight hardware surfaces. A bioburden density estimate factors in the following variables: the observed bioburden count, representative volume processed, sampling efficiencies. Notably, to account for error in the approach, a 0 observed count is arbitrarily changed to a count of 1 for each hardware grouping. The data generated by spacecraft bioburden verification campaigns in the past have resulted in <80% of wipes and <90% of swabs containing a bioburden count of 0. As such, having a robust and well documented statistical approach for dealing with the probability of low incident rates is necessary to be able to estimate spacecraft bioburden. Being able to statistically describe the bioburden distribution and associated confidence level is a gamechanger for the development of bioburden allocations during mission design and will allow for tighter management of risk throughout spacecraft build. Thus, Empirical Bayes statistical approach was evaluated to estimate the microbial bioburden on spacecraft to mitigate the aforementioned mathematical concerns and provide a probabilistic bioburden distribution of the flight hardware surface. For application of this approach to performing bioburden calculations, a range of non-informative prior assumptions on hardware surfaces are explored for Bayesian analyses while informative priors using posterior distributions from prior assays are utilized for Empirical Bayes analyses. Several non-informative priors are currently under investigation to assess fitness including use of these priors to serve as a foundation to build off of NASA specification values or a basis of risk to account for unknowns during the integration and testing process. Informative priors under consideration are generated using sampled bioburden values from hardware originating within like processing environments (e.g. vendor cleaning process or similar assembly process), temporal spacecraft status events as a prediction for hardware cleanliness of future samples, and heritage system bioburden actuals to predict allocation for subsequent missions. Informative priors and probabilistic bioburden distributions are then validated using data sets from the Mars Exploration Rover, Mars Science Laboratory, and InSight missions. Using Empirical Bayes approach to generate a probabilistic bioburden distribution as demonstrated through mission use cases provides a valid approach for use in the end-to-end requirements verification process.

97 MATHEMATICS AND COMPUTING↗

Bayesian Framework for Bioburden Density Estimation in Planetary Protection

To comply with the international planetary protection policy set forth by the Committee on Space Research and NASA Agency level requirements, spacecraft destined to biologically sensitive planetary bodies have to minimize terrestrial biological contamination. Analysis, testing and inspection are the standard forward verification activities that are used to demonstrate compliance with the biological contamination requirements. For testing of spacecraft surface areas, a swab or wipe sample is collected from surfaces prior to last access and subsequently processed in the lab using NASA Approved Planetary Protection Methods for Culture Based Assays. Raw data resulting from this assay is then statistically treated employing a mathematical paradigm stemming from the 1970’s Viking Lander Project to generate the bioburden density and total microbial bioburden present. This standard approach arbitrarily accounts for error and provides an upper conservative bound as it reports the maximum number of spores estimated to be present on flight hardware surfaces. A bioburden density estimate factors in the following variables: the observed bioburden count, representative volume processed, sampling efficiencies. Notably, to account for error in the approach, a 0 observed count is arbitrarily changed to a count of 1 for each hardware grouping. The data generated by spacecraft bioburden verification campaigns in the past have resulted in <80% of wipes and <90% of swabs containing a bioburden count of 0. As such, having a robust and well documented statistical approach for dealing with the probability of low incident rates is necessary to be able to estimate spacecraft bioburden. Being able to statistically describe the bioburden distribution and associated confidence level is a gamechanger for the development of bioburden allocations during mission design and will allow for tighter management of risk throughout spacecraft build. Thus, Empirical Bayes statistical approach was evaluated to estimate the microbial bioburden on spacecraft to mitigate the aforementioned mathematical concerns and provide a probabilistic bioburden distribution of the flight hardware surface. For application of this approach to performing bioburden calculations, a range of non-informative prior assumptions on hardware surfaces are explored for Bayesian analyses while informative priors using posterior distributions from prior assays are utilized for Empirical Bayes analyses. Several non-informative priors are currently under investigation to assess fitness including use of these priors to serve as a foundation to build off of NASA specification values or a basis of risk to account for unknowns during the integration and testing process. Informative priors under consideration are generated using sampled bioburden values from hardware originating within like processing environments (e.g. vendor cleaning process or similar assembly process), temporal spacecraft status events as a prediction for hardware cleanliness of future samples, and heritage system bioburden actuals to predict allocation for subsequent missions. Informative priors and probabilistic bioburden distributions are then validated using data sets from the Mars Exploration Rover, Mars Science Laboratory, and InSight missions. Using Empirical Bayes approach to generate a probabilistic bioburden distribution as demonstrated through mission use cases provides a valid approach for use in the end-to-end requirements verification process.

97 - MATHEMATICS AND COMPUTING↗

Improving the Field Portability of Neutron and Gamma Counting Techniques

Savannah River National Laboratory (SRNL) puts science to work by developing techniques that better meet customers needs for in-situ measurements. There is high demand for laboratory quality measurements in field situations, improving the cost and speed for first responders and environmental monitoring. This work focused on two improvements (1) reading a signal from a neutron detector using a Raspberry Pi (2) testing the Peak-to-Valley method for determining the depth of a source in soil contamination measurements. A Raspberry Pi is a cheap, compact computer. This affordable, compact computer is able to do simple tasks that a desktop computer is able to do, like spreadsheets, browse the internet, play games and even program a simple robot. Additionally, a Raspberry Pi can run off of a battery, so it could be deployed for long term measurements in adverse conditions like neutron monitors deployed in a shipping port. Using the Raspberry Pi and libraries easily accessible on the internet, a code was written in Python that allows the Pi to keep track of how many times a button is pushed. This work will be used with the future goal of creating low power-budget neutron detectors. 1) Make sure Python was correctly installed on the Raspberry Pi. 2) Write a code that will keep track of how many times a button connected to the Pi is pressed. A code was written to use the Raspberry Pi to count the number of times the button was pushed. Moving forward the Raspberry Pi will be tested with a neutron counter. Ideally, each signal from the neutron pulse will be equivalent of 'push the button' and be counted. In the characterization of a soil contamination area both the location and the depth of the source is important. Attenuation of the source by the soil can make determining its depth challenging, particularly for monoenergetic radionuclides like Cs-137. To address this issue, a method of calculating the 'peak-to-valley' ratio of the gamma count spectra is implemented to help calculate the known depth of the source. 1) Determine the 'peak-to-valley' ratio of a Cs-137 source at different depths. 2) Find an appropriate function to serve as a model for the peak-to-valley ratio as a function of depth. Several Petri dishes, filled with sand, were stacked with one containing a Cs-137 source. The individual Petri dishes allowed for the source to be placed at different depths. A bucket was placed over the sand and source, to keep the detector at a consistent height. A Petri dish containing a Eu-155 source, which acted as an internal calibration standard, was placed on top of the bucket. A NaI detector was place on top of the Eu-155 source and the assembly was surrounded by a tungsten shield. Count times were 20 minutes and the data was analyzed using PeakEasy. Data was recorded for Cs-137 at a series of depths in sand. Both exponential and logarithmic functions provided a reasonable fit to the data. The experimental data showed a decreasing 'peak-to-valley' ratio as the depth was increased. The next steps for this project involves determining the optimum fit function and combining the results from sand to different soil types to get a better representation of the soil found at SRS. Eventually, the peak-to-valley ratio will be used to estimate the depth of contamination in field measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calculations for Calibration of a Mass Spectrometer

A computer program performs calculations to calibrate a quadrupole mass spectrometer in an instrumentation system for identifying trace amounts of organic chemicals in air. In the operation of the mass spectrometer, the mass-to-charge ratio (m/z) of ions being counted at a given instant of time is a function of the instantaneous value of a repeating ramp voltage waveform applied to electrodes. The count rate as a function of time can be converted to an m/z spectrum (equivalent to a mass spectrum for singly charged ions), provided that a calibration of m/z is available. The present computer program can perform the calibration in either or both of two ways: (1) Following a data-based approach, it can utilize the count-rate peaks and the times thereof measured when fed with air containing known organic compounds. (2) It can utilize a theoretical proportionality between the instantaneous m/z and the instantaneous value of an oscillating applied voltage. The program can also estimate the error of the calibration performed by the data-based approach. If calibrations are performed in both ways, then the results can be compared to obtain further estimates of errors.

Lee, Seungwon↗

GIANT GROUND LEVEL ENHANCEMENT OF RELATIVISTIC SOLAR PROTONS ON 2005 JANUARY 20. I. SPACESHIP EARTH OBSERVATIONS

A ground level enhancement (GLE) is a solar event that accelerates ions (mostly protons) to GeV range energies in such great numbers that ground-based detectors, such as neutron monitors, observe their showers in Earth's atmosphere above the Galactic cosmic ray background. GLEs are of practical interest because an enhanced relativistic ion flux poses a hazard to astronauts, air crews, and aircraft electronics, and provides the earliest direct indication of an impending space radiation storm. The giant GLE of 2005 January 20 was the second largest on record (and largest since 1956), with up to 4200% count rate enhancement at sea level. We analyzed data from the Spaceship Earth network, supplemented to comprise 13 polar neutron monitor stations with distinct asymptotic viewing directions and Polar Bare neutron counters at South Pole, to determine the time evolution of the relativistic proton density, energy spectrum, and three-dimensional directional distribution. We identify two energy-dispersive peaks, indicating two solar injections. The relativistic solar protons were initially strongly beamed, with a peak maximum-to-minimum anisotropy ratio over 1000:1. The directional distribution is characterized by an axis of symmetry, determined independently for each minute of data, whose angle from the magnetic field slowly varied from about 60 Degree-Sign to low values and then rose to about 90 Degree-Sign . The extremely high relativistic proton flux from certain directions allowed 10 s tracking of count rates, revealing fluctuations of period {approx}> 2 minutes with up to 50% fractional changes, which we attribute to fluctuations in the axis of symmetry.

79 ASTRONOMY AND ASTROPHYSICS↗

A DEEP 1.2 mm MAP OF THE LOCKMAN HOLE NORTH FIELD

We present deep 1.2 mm continuum mapping of a 566 arcmin{sup 2} area within the Lockman Hole North (LHN) field, previously a target of the Spitzer Wide-Area Infrared Extragalactic survey and extremely deep 20 cm mapping with the Very Large Array, which we have obtained using the Max-Planck millimeter bolometer (MAMBO) array on the IRAM 30 m telescope. After filtering, our full map has an rms sensitivity ranging from 0.45 to 1.5 mJy beam{sup -1}, with an average of 0.75 mJy beam{sup -1}. Using the pixel flux distribution (PFD) in a map made from our best data, we determine the shape, normalization, and approximate flux density cutoff for 1.2 mm number counts well below our nominal sensitivity and confusion limits. After validating our full data set through comparison with this map, we successfully detect 41 1.2 mm sources with signal-to-noise ratio (S/N) > 4.0 and S{sub 1.2{sub mm}} {approx_equal} 2-5 mJy. We use the most significant of these detections to directly determine the integral number counts down to 1.8 mJy, which are consistent with the results of the PFD analysis. Ninety-three percent of our 41 individual detections have 20 cm counterparts, 49% have Spitzer/MIPS 24 {mu}m counterparts, and one may have a significant Chandra X-ray counterpart. We resolve {approx_equal} 3% of the cosmic infrared background (CIB) at 1.2 mm into significant detections and directly estimate a 0.05 mJy faint-end cutoff for the counts that is consistent with the full intensity of the 1.2 mm CIB. The median redshift of our 17 detections with spectroscopic or robust photometric redshifts is z{sub median} = 2.3, and rises to z{sub median} = 2.9 when we include redshifts estimated from the radio/far-infrared spectral index. By using a nearest neighbor and angular correlation function analysis, we find evidence that our S/N > 4.0 detections are clustered at the 95% confidence level.

79 ASTRONOMY AND ASTROPHYSICS↗

Trials and tribulations in the first three years in operation of the SSAMS for biomedical 14 C-AMS at LLNL

We report on the first several years of operation of our recently installed 250 kV SSAMS at LLNL, purchased to replace our 1-MV AMS system for the measurement of 14 C from labeled biochemical samples. We have modified the ion source region to improve ion output. Additionally, the SSAMS required significant software modifications to the data acquisition system in order to accurately measure 14 C at the high-count rates typically encountered with labeled biochemical samples. Here, we found that the data can be corrected assuming a nonparalyzable dead time response with a single event dead time of 6 µs. Since operation began, we have measured over 13,000 graphitic unknowns and over 1900 standards with an overall precision of 1.0%. We have optimized our system for the analysis of CO 2 gas samples. We compared aliquots of identical samples measured as solid graphite and as liquid drops. Excellent agreement was found between the two, although the average precision of the graphite targets was an order of magnitude better than the liquid drop analysis due to the much larger number of 14 C atoms available for measurement.

42 ENGINEERING↗

TriC: Distributed-memory Triangle Counting by Exploiting the Graph Structure

Graph analytics has emerged as an important tool in the analysis of large scale data from diverse application domains such as social networks, cyber security and bioinformatics. Counting the number of triangles in a graph is a fundamental kernel with several applications such as detecting the community structure of a graph or in identifying important vertices in a graph. The ubiquity of massive datasets is driving the need to scale graph analytics on parallel systems. However, numerous challenges exist in efficiently parallelizing graph algorithms, especially on distributed-memory systems. Irregular memory accesses and communication patterns, low computation to communication ratios, and the need for frequent synchronization are some of the leading challenges. In this paper, we present TriC, our distributed-memory implementation of triangle counting in graphs using the Message Passing Interface (MPI), as a submission to the 2020 GraphChallenge competition. Using a set of synthetic and real-world inputs from the challenge, we demonstrate a speedup of up to 90x relative to previous work on 32 processor-cores of a NERSC Cori node. We also provide details from distributed runs with up to8192 processes along with strong scaling results. The observations presented in this work provide an understanding of the system-level bottlenecks at scale that specifically impact sparse-irregular workloads and will therefore benefit other efforts to parallelize graph algorithms.

Halappanavar, Mahantesh↗