Search NASA⌕ Search

SEARCH · Search NASA

Results for “cyber systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Cyber-Physical Event Emulation-Based Transmission-and-Distribution Co-Simulation for Situational Awareness of Grid Anomalies (SAGA)

Energy management of transmission and distribution networks (T&D) is becoming more challenging with the accelerated adoption of distributed energy resources (DERs)-such as distributed photovoltaic generation and battery energy storage systems (BESS)-on the electric grid. To better analyze the impacts of DERs on both transmission and distribution systems, a comprehensive T&D co-simulation platform is developed. Further, with DERs more actively participating in system operation-e.g., by providing real-time grid services-their cyber vulnerability needs to be better understood to maintain system reliability. This paper discusses a cyber-physical events emulation-based T&D co-simulation platform to perform comprehensive cyber events emulations, physical simulation, and analysis of interdependent impacts. Results from the case studies-which show how cyber events on a synthetic distribution network can impact operations on the transmission and distribution network-validate that the proposed T&D cosimulation platform can perform cyber-physical events emulation and produce response in near realtime; therefore, with extensive simulation using the proposed co-simulation platform, the system operators can accumulate adequate training data for system situational awareness of grid anomalies.

anomalies detection↗

Digital risk analysis in nuclear engineering projects: Designing for safety, performance, reliability, and security

Cyber-informed engineering and security-by-design frameworks are important in promoting the need to identify cybersecurity concerns early in the systems engineering lifecycle so risks from adversarial cyber-attacks can be eliminated or reduced through engineering design practices. In addition to adversarial risk, risk in operational technology systems also includes non-adversarial and unintentional risk from other factors such as human performance errors, environmental conditions, design flaws, and device degradation or failure. This paper introduces a new concept for characterizing digital risk, both adversarial and non-adversarial, and provides the basis for initial research into a novel digital risk analysis approach focused on incorporating attack difficulty into a multi-attribute analysis technique using robust decision-making. This digital risk characterization is also used to frame a discussion on the challenges of competing objectives and competing stakeholder requirements in an integrated energy system project that incorporates a small modular reactor and industrial facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cyber-Informed Engineering Validation Methods and Guidance

Validation is an important step in any systems engineering process to ensure the correct system was made to fulfill stakeholders’ needs, goals, and expectations. In the context of Cyber-Informed Engineering (CIE), validation ensures cyber impact is reduced through implemented design choices and CIE requirements. This document details a process in validating CIE-based design choices relative to their effectiveness at mitigating high consequence events. The document includes a case study to illustrate the CIE validation process. The case study explores the implementation of CIE validation within the engineering lifecycle of a chemical mixing plant.

42 ENGINEERING↗

Autonomous System Inference, Trojan, and Adversarial Reprogramming Attack and Defense (Final)

In the world of ever-advancing technology, Autonomous Systems (AS) find extensive application, bolstering functionalities of critical infrastructures such as nuclear power plants. These systems, however, are increasingly becoming a target for nefarious activities, namely through inference attacks, trojan attacks, and adversarial reprogramming. This paper delves into a comprehensive exploration of machine learning (ML)-driven autonomous control systems within advanced nuclear reactor designs, revealing the vulnerabilities and proposing strategies for defense against potential cyber-attacks. Advanced cyber-attacks against critical infrastructure and the energy sector are becoming more common. With the invention of autonomous control systems (ACS) within advanced nuclear reactor designs, system designers, reactor operators, and regulators must consider cybersecurity during the design and operational phases. This article provides a cyber threat assessment of machine learning (ML)- based digital twinning (DT) technologies in the context of advanced reactor ACS. A cyber-physical testbed was created to emulate nuclear reactor digital instrumentation and controls (I&C) and act as a basis for the ACS. The ACS was designed as two plant-level DTs predicting reactor malfunctions and determining control actions and two component-level DTs responsible for classifying component states and forecasting component inputs and outputs (I/O). Two duplicate ACS designs– one using a traditional ML framework and one using an automated ML (AutoML) framework– were created and tested against cyber-attacks on training data, real-time process data, and ML model architectures to determine their respective qualitative cyber-risk in terms of likelihood and impact. Both frameworks showed similar cyber-resilience against training, real-time, and ML architecture attacks, proving that neither is inherently more secure. Recommended safeguard and security measures are posed to system designers, reactor operators, and regulators to maintain the cybersecurity of ML-based DT technologies such as ACS, prompting a holistic view of shared responsibility for maintaining cyber-secure ML-based systems. As global reliance on generation III reactors begins to be critically assessed, the evolution towards advanced reactor systems utilizing digital instrumentation and controls (I&C) becomes not merely preferable, but essential. The integration of semi and fully autonomous control systems (ACS), powered by digital I&C and machine learning (ML)-based digital twinning (DT) technologies, emerges as a potent strategy to mitigate operations and maintenance costs, thereby enhancing the economic feasibility of novel reactor designs. However, with a staggering 500% and 380% increase in cyber-attacks reported against the energy sector by the United States Department of Energy (DoE) and the European Union respectively, a surge in cyber vulnerabilities specifically targeting the nuclear industry has been 2 markedly observed. Notable incidents, such as the W32.Ramnit spyware infiltration at the Gundremmingen nuclear power plant in Germany and the Dtrack spyware intrusion at the Kudankulam nuclear power plant in India, while not directly compromising core industrial control systems (ICS), underscore a compelling necessity to fortify cybersecurity protocols in safeguarding reactor systems against increasingly adept digital adversaries. In light of this, our investigation extends beyond conventional cybersecurity parameters, diving into the intricate web of potential vulnerabilities woven into ML-based DTs and ACS in advanced reactor systems. A crafted cyber-physical testbed and preliminary ACS were devised to act as a mirror, reflecting potential configurations of advanced reactor control designs. Moreover, this study is intertwined with a scrutinization of ML models, developed either through conventional, manually tuned methodologies or via automated means through AutoML, probing into their cyber-risk profiles within operational technology (OT) environments. Expanding on this, two distinct ACS blueprints were forged – one navigating through the corridors of traditional ML and the other traversing the path of AutoML – in an effort to holistically encapsulate the considerations pivotal to ML-based DT control system design. Employing the SANS Institute Industrial Control System (ICS) Kill Chain and the MITRE ATT&CK Tactics, Techniques, and Procedures (TTP) framework, a structured analysis was conducted, launching three targeted attacks against the training dataset, real-time dataset, and ML models, therein dissecting the potential cyber-attack implications against both ML frameworks within an ACS milieu. It is essential to note that three distinct categories of attacks were conducted against both ACS configurations, each encompassing three distinct ML-based DTs, cumulating in a total of 18 varied attacks. This exploration extends into the realms of Autonomous System Inference, Trojan, and Adversarial Reprogramming Attack and Defense, unraveling vulnerabilities, and opportunities for fortified defenses against such intrusions, particularly where ML-driven technologies, and by extension, ACS, are deployed. Final recommendations, articulated through a lens of security, safeguard, and implementation considerations, are presented for both traditional and AutoML models, anchoring upon the existing knowledge landscape and ML-based DT modeling for ACS, and are offered as a beacon to guide the nuclear industry through the intricate cybersecurity challenges that lie ahead.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A holistic cyber-physical security protocol for authenticating the provenance and integrity of structural health monitoring imagery data

Modern infrastructure systems, such as bridges, dams, power generation stations, and buildings increasingly have an intrinsic cyber-physical nature to them. Infrastructure now commonly, includes actuators, network connections, sensors, control systems, and computational resources. It is of increasing concern that modern infrastructure is vulnerable to cyber-attacks that can damage both the cyber and physical nature of the infrastructure. To date, the physical and cyber health of infrastructure has been considered separately. However, the increasing concerns associated with the cyber-physical security of infrastructure coupled with the emergence of 5G networks made using components that are not universally considered trustworthy, and the emergence of techniques for creating deepfakes and adversarial examples suggests the time has come to begin considering cyber health and structural health with a more holistic approach. In this work, a protocol is developed for ensuring the imagery data captured by a structural health monitoring system can be unambiguously attributed to legitimate sensors associated with the structural health monitoring system. A computer vision approach based on the idea of mutual information is then presented to detect damage in an image. This work presents the protocol for authenticating the provenance of imager data and demonstrates that this protocol does not have overly adverse effects when used with the mutual information-based technique for detecting damage in the resulting imagery data.

Jung, HweeKwon↗

A Trilevel Model for Segmentation of the Power Transmission Grid Cyber Network

Network segmentation of a power grid's communication system can make the grid more resilient to cyberattacks. Here we develop a novel trilevel programming model to optimally segment a grid communication system, taking into account the actions of an information technology (IT) administrator, attacker, and grid operator. The IT administrator is allowed to segment existing networks, and the attacker is given a budget to inflict damage on the grid by attacking the segmented communication system. Finally, the grid operator can redispatch the grid after the attack to minimize damage. The resulting problem is a trilevel interdiction problem that we solve using a branch and bound algorithm for bilevel problems. We demonstrate the benefits of optimal network segmentation through case studies on the 9-bus Western System Coordinating Council (WSCC) system and the 30-bus IEEE system. These examples illustrate that network segmentation can significantly reduce the threat posed by a cyberattacker.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analyzing the Effects of Cyberattacks on Distribution System State Estimation: Preprint

Key components of power systems—such as energy management systems, automatic generation control, and state estimation—are under serious vulnerability from cyber attacks. Cyber threats in electric grids have increased significantly because of the increased interconnectivity of supervisory control and data acquisition systems and public network infrastructure. As the penetration level of distributed energy resources increases, it is imperative to employ system-monitoring techniques such as state estimation for the reliable operation of distribution systems. Recently, multiple methods have been developed that exploit the low rank property of distribution system state matrix and are robust to bad data, such as matrix completion. This paper analyzes the impact of various realistic cyber attack scenarios on matrix completion. Realistic cyber attack scenarios are converted into data corruption models that are used in an extensive simulation of a custom IEEE 123-bus system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Integrating 5G Technology for Improved Process Monitoring and Network Slicing in ICS

Industrial Control Systems (ICS) are crucial for monitoring physical processes that support essential cyber-enabled services like power generation. The use of proprietary communication and lack of effective intrusion detection mechanisms pose constraints for efficient operation. Therefore, there is a need to modernize these systems with decentralized technologies like Edge Computing and 5G. However, integrating 5G and Edge Computing into large-scale ICS networks presents implementation and performance challenges. To address these challenges, this paper proposes an integrated ICS architecture that combines 5G and Edge Computing technologies with traditional ICS protocols. The objective is to minimize implementation and operational difficulties while improving the monitoring of physical processes and enabling robust intrusion detection. The proposed architecture outlines the necessary components, services, and communication protocols required for the integration of 5G and Edge Computing.

Aguayo, Jared M.↗

Cybersecurity for Electric Vehicle Charging Infrastructure

As the U.S. electrifies the transportation sector, cyberattacks targeting vehicle charging could impact several critical infrastructure sectors including power systems, manufacturing, medical services, and agriculture. This is a growing area of concern as charging stations increase power delivery capabilities and must communicate to authorize charging, sequence the charging process, and manage load (grid operators, vehicles, OEM vendors, charging network operators, etc.). The research challenges are numerous and complicated because there are many end users, stakeholders, and software and equipment vendors interests involved. Poorly implemented electric vehicle supply equipment (EVSE), electric vehicle (EV), or grid operator communication systems could be a significant risk to EV adoption because the political, social, and financial impact of cyberattacks — or public perception of such — would ripple across the industry and produce lasting effects. Unfortunately, there is currently no comprehensive EVSE cybersecurity approach and limited best practices have been adopted by the EV/EVSE industry. There is an incomplete industry understanding of the attack surface, interconnected assets, and unsecured inter faces. Comprehensive cybersecurity recommendations founded on sound research are necessary to secure EV charging infrastructure. This project provided the power, security, and automotive industry with a strong technical basis for securing this infrastructure by developing threat models, determining technology gaps, and identifying or developing effective countermeasures. Specifically, the team created a cybersecurity threat model and performed a technical risk assessment of EVSE assets across multiple manufacturers and vendors, so that automotive, charging, and utility stakeholders could better protect customers, vehicles, and power systems in the face of new cyber threats.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordinated Thermal Safety Attack and Defense on EV Battery Management Systems

Battery temperature sensor and battery current sensor data which are key sensing inputs to the Battery Management Controllers in electric vehicles, are vulnerable to possible cyber/ physical manipulation due to known vulnerabilities inherited from CAN bus technology that is used for in-vehicle communications between electronic control units that transfer sensing and control data. In this paper, we first create a simulation that enables us to evaluate impact of cyber physical attacks on electric vehicle battery management system in a controlled environment that violates thermal safety. Specifically, we emulate a Level 3 - DC fast charging system with SAE J1772/CCS, integrated with standard charging controls and thermal safety controls on EVs, and various sensing data flows. Second, we propose a coordinated current and battery temperature attack that has crippling economic, and safety impacts. Third, we quantify the usability, economic and safety impacts of such attacks as a function of the extent of data manipulation. Finally, we propose a physics model driven detection technique to detect presence of such attacks.

25 ENERGY STORAGE↗

Situational Awareness of Grid Anomalies (SAGA) for Visual Analytics—Near-Real-Time Cyber-Physical Resiliency Through Machine Learning

The Situational Awareness of Grid Anomalies (SAGA) project built upon foundational power system tools developed at the National Renewable Energy Laboratory (NREL) integrated with an ever-increasing set of Gridmetrics data extracted from the cable television (CATV) broadband network infrastructure while assimilating other time-series geospatial data and information, such as weather and cyber-physical phenomena, to demonstrate a disruptive technology for power system data analytics relying on existing infrastructure. Three research thrusts supported (1) visual analytics, (2) cyber-physical power system simulation, and (3) anomaly detection. SAGA created technology that leverages, couples, and fortifies two vastly different realms - power and broadband - to increase the resiliency of the power grid in the face of increasing cyberattacks and operational challenges related to integrating DERs. The exploration of potential synergies of broadband-enabled grids resulted in identifying a mutually beneficial symbiosis that can increase the resiliency of both power and broadband services. Broadband networks perform better with reliable power and are good at providing real-time measurements that identify where the grid is under attack, is failing, or is weak. Likewise, sensor-starved distribution grids perform better and can be more reliable when their operation is buttressed with observations of broadband-detected anomalies. Future research can explore broadband's contribution to continuing to improve grid resiliency, reliability, and cost-effective operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating Cyber-Informed Engineering into Enterprise Risk Management

This document supports the application of Cyber-Informed Engineering (CIE) within the context of Enterprise Risk Management (ERM) to enhance cyber-resilience. It highlights that many critical infrastructure organizations use ERM to manage business risks and emphasizes the importance of evaluating critical systems and assets. The proposed approach can be adopted independently of formal ERM processes and offers a starting point for integrating CIE alongside existing or new ERM practices. Both CIE and ERM are iterative, and their alignment fosters continuous improvement and supports the engineering and operations cultures of an organization.

42 ENGINEERING↗

Analyzing the Effects of Cyberattacks on Distribution System State Estimation

Key components of power systems—such as energy management systems, automatic generation control, and state estimation—are under serious vulnerability from cyberattacks. Cyber threats in electric grids have increased significantly because of the increased interconnectivity of supervisory control and data acquisition systems and public network infrastructure. As the penetration level of distributed energy resources increases, it is imperative to employ system-monitoring techniques such as state estimation for the reliable operation of distribution systems. Recently, multiple methods have been developed that exploit the low rank property of distribution system state matrix and are robust to bad data, such as matrix completion. This paper analyzes the impact of various realistic cyberattack scenarios on matrix completion. Realistic cyberattack scenarios are converted into data corruption models that are used in an extensive simulation of a custom IEEE 123-bus system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Cybersecurity Enhancement in Digital Substations: Hidden Markov Model-Based Smart Cyber Switching and Threat Response

The rising incidence of cyber-attacks on critical infrastructure and power grids poses significant threats to the stability and reliability of electrical substations, with potentially devastating consequences such as extended blackouts. This paper introduces an advanced cybersecurity framework aimed at safeguarding IEC 61850-based substations through the integration of software-defined networking (SDN) and digital twin (DT) technologies. The proposed DT-based framework employs smart cyber switching (SCS) for proactive threat mitigation and concurrent intelligent electronic device (CIED) for swift system restoration, thereby maintaining continuous operational integrity and robust cybersecurity defenses. Central to this framework is the adaptive port controller (APC), which enables dynamic port management to adapt to evolving threats, and an intrusion detection system (IDS) designed to detect and neutralize malicious attacks on IEC 61850-based sampled value (SV) and generic object-oriented substation event (GOOSE) messages within the substation’s communication network. Further, novel predictive intrusion detection and response (PIDR) algorithm is implemented on a digital substation (DS) to predict the best route to be taken by the attacker. The efficacy of these comprehensive cybersecurity frameworks is validated through rigorous simulations and a hardware-in-the-loop (HIL) testbed, showcasing the system’s ability to sustain substation operations amidst cyber-attacks.

Digital substation↗

Risk Analysis for Remote Operation of Microreactors

Microreactors are a subset of advanced nuclear reactors that can be factory fabricated, transportable, and self-regulating. They have the potential to be used in microgrids, rural and remote areas, or emergency response applications, replacing fossil fuel sources like diesel generators and enabling sustainable energy generation. In order to make microreactor operation cost-effective, it is likely that remote communications will be needed to reduce the number of personnel required to be on site. While remote operation of energy generation and other industrial control systems is common in other industries, it is not yet adopted in the nuclear community and has many perceived and actual risks. In this paper, the severity of the risks introduced by remote operations for microreactors are explored. The primary changes in the operations involve the addition of a remote communications network and a certification system for data and controls. These changes lend themselves to considerations of cyber risks, whether unintentional or adversarial, but the assessment considers not just cyber risks introduced, but also how physical and human factors-based risks will impact the remote operations system and change the overall risk profile. This initial assessment indicates that there are standard cyber and mitigation measures that can be put in place so the risk of doing remote operations does not dramatically increase compared to local operations. This evaluation is a critical step in the process of evaluating if remote operations of microreactors is a suitable solution to meet future sustainable grid needs

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of Convex supercomputers for flight simulation at NASA Langley

The use of the Convex Computer Corporation supercomputers for flight simulation is discussed focusing on a real-time input/output system for supporting the flight simulation. The flight simulation computing system is based on two single processor control data corporation CYBER 175 computers, coupled through extended memory. The Advanced Real-Time Simulation System for digital data distribution and signal conversion is a state-of-the-art, high-speed fiber-optic-based, ring network system which is based on the computer automated measurement and control technology.

Cleveland, Jeff I., II↗

Trust-Based Detection and Mitigation of Cyber Attacks in Distributed Cooperative Control of Islanded AC Microgrids

In this study, we address the challenge of detecting and mitigating cyber attacks in the distributed cooperative control of islanded AC microgrids, with a particular focus on detecting False Data Injection Attacks (FDIAs), a significant threat to the Smart Grid (SG). The SG integrates traditional power systems with communication networks, creating a complex system with numerous vulnerable links, making it a prime target for cyber attacks. These attacks can lead to the disclosure of private data, control network failures, and even blackouts. Unlike machine learning-based approaches that require extensive datasets and mathematical models dependent on accurate system modeling, our method is free from such dependencies. To enhance the microgrid’s resilience against these threats, we propose a resilient control algorithm by introducing a novel trustworthiness parameter into the traditional cooperative control algorithm. Our method evaluates the trustworthiness of distributed energy resources (DERs) based on their voltage measurements and exchanged information, using Kullback-Leibler (KL) divergence to dynamically adjust control actions. We validated our approach through simulations on both the IEEE-34 bus feeder system with eight DERs and a larger microgrid with twenty-two DERs. The results demonstrated a detection accuracy of around 100%, with millisecond range mitigation time, ensuring rapid system recovery. Additionally, our method improved system stability by up to almost 100% under attack scenarios, showcasing its effectiveness in promptly detecting attacks and maintaining system resilience. These findings highlight the potential of our approach to enhance the security and stability of microgrid systems in the face of cyber threats.

Computer Science↗