Search NASA⌕ Search

SEARCH · Search NASA

Results for “device testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Modeling, design, fabrication, and testing of InP Gunn devices in the D-band (110 GHz - 170 GHz)

The development of fundamental Gunn sources for D-band frequencies requires improvements of doping profiles, processing technology, and circuit design. We have developed a technology for fabricating InP Gunn diodes using an InGaAs etch-stop layer between the InP substrate and the device layers. The epitaxial layers were grown by CBE. During device processing, the substrate is completely removed. Substrateless devices with an n(+) InGaAs cap layer are expected to have reduced contact and series resistances, and skin effect losses. This technology gives better uniformity and control of the device geometry across the processed chip. InP Gunn devices with a 1.7 micron long active region (doping : 9 x 10(exp 15) cm(exp -3)) have been mounted on copper heat sinks. Two tapered leads were then bonded to the diode and to four quartz standoffs. As a preliminary result, an output power of 13 mW at 82 GHz was obtained. Based on these RF measurements, we determine appropriate material parameters to be used in the Ensemble Monte Carlo model. Subsequently, we use this model to design and evaluate the performance of InP Gunn Devices for D-band frequencies. Using the same technology, we are currently processing Gunn devices with a 1 micron long active region for operation at higher frequencies.

Kamoua, R.↗

New Technology for Microfabrication and Testing of a Thermoelectric Device for Generating Mobile Electrical Power

Thermoelectric (TE) power generation is an increasingly important power generation technology. Major advantages include: no moving parts, low-weight, modularity, covertness/silence, high power density, low amortized cost, and long service life with minimum or no required maintenance. Despite low efficiency of power generation, there are many specialized needs for electrical power that TE technologies can uniquely and successfully address. Recent advances in thermoelectric materials technology have rekindled acute interest in thermoelectric power generation. We have developed single crystalline n- and p- type PbTe crystals and are also, developing PbTe bulk nanocomposites using PbTe nano powders and emerging filed assisted sintering technology (FAST). We will discuss the materials requirements for efficient thermoelectric power generation using waste heat at intermediate temperature range (6500 to 8500 K). We will present our recent results on production of n- and p- type PbTe crystals and their thermoelectric characterization. Relative characteristics and performance of PbTe bulk single crystals and nano composites for thermoelectric power generation will be discussed.

Prasad, Narasimha S.↗

Identification and Reduction of Interactional Noise of a Quadcopter in Hover and Forward Flight Conditions

Advanced Air Mobility is a vision for a safe, accessible, and sustainable aviation system to transport people and cargo between places not served by traditional aviation. With this emerging transportation industry, there is motivation to characterize the noise of vehicles to determine their potential impacts on the community. An experimental testing campaign was conducted on a representative model of a small unmanned aircraft system in the NASA Langley Low Speed Aeroacoustic Wind Tunnel as a continuation of a previous testing campaign. The goals of the current test are to identify sources of interactional noise as well as to test custom-designed rotors and noise reduction devices. The tested noise reduction methods involve increasing the vertical distances between the rotors and the vehicle airframe as well as between the forward and aft rotor disk planes. These methods are intended to reduce rotor-airframe interaction noise in hover and fore-aft rotor wake ingestion noise in forward flight. A phased microphone array is also utilized to identify the locations of prominent noise generation for the different vehicle configurations in forward flight. Elevation of the rotors from the vehicle airframe yielded nearly 8 dBA overall noise reduction in forward flight, while yielding up to 4 dB reduction in overall tonal levels for one of the rotors in hover.

Nikolas S Zawodny↗

Single-Event Effect Testing of the Analog Devices AD8041ARZ Operational Amplifier

This study was undertaken to determine the single event transient distribution of a transimpedance amplifier configuration of the AD8041 Operational Amplifier. The AD8041 is made in a bipolar technology and the application of interest has a bipolar supply of ±5 V. The device was monitored for transient events on the output voltage during exposure to a heavy ion beam at Lawrence Berkeley National Laboratory’s (LBNL) 88-inch Cyclotron.

Matthew B. Joplin↗

Investigation for single-event upset in MSI devices

The reported investigation shows that low-power TTL, standard TTL, low-power Schottky, and Schottky devices are all subject to upset by heavy ions. Low-power Schottky was the most sensitive of the device technologies tested. No evidence was found to correlate sensitivity to cosmic rays with any particular device manufacturer. The probability of upset of the logic devices is comparable to that of RAM's on a per-flip-flop basis, based on RAM data obtained by Kolasinski et al. (1979). The testing was performed by subjecting the devices to 120 MeV krypton ions from a cyclotron.

Woods, J. P.↗

Dynamics and mechanism of cavitation erosion on perspex and epoxy resins tested in a rotating disk device

The cavitation erosion behavior including the initiation, dynamics and mechanism of damage process on perspex and epoxy resin specimens tested in a rotating disk device were discussed with respect to exposure time. The inception of erosion always took place at the location nearest to the center of rotation of the disk. Subsequently, as exposure time increased, erosion initiated at other locations as well. Light optical photographs and scanning electron micrographs clearly indicate that most of the material loss appears to occur form the networks of cracks due to their interaction and pits indicate particle debris. The optical degradation (loss of transmittance) on perspex was observed to be more on the rear side than on the front side.

Rao, P. V.↗

Dynamic Testing of a Commercial FRAM Device Under Gamma Ray Dose and Neutron Beam

Here, this work presents dose rate and neutron testing on a ferroelectric random-access memory (FRAM) device in dynamic operation during radiation pulses. Radiation failure modes are shown to be unique. Dose rate failure is shown to be based primarily on integrated dose in the radiation pulse and terminates the FRAM operation and can alter up to 8 bytes of data in storage. Neutron failures are attributed to a shifting of data like a clocking error.

Harris, Nathan↗

Vulnerability Studies Under EMP: Impedance and PCI Testing of the Grid Control Devices

Control devices such as inverters and generator controllers are critical for the stable operation of the power grid, especially for power stability control and power dispatch. However, the Electromagnetic Pulse (EMP) is a potential threat to electronic devices in modern power grids, therefore decreasing the power grid resilience and bringing unrecoverable damages to the devices. To reveal the impact mechanism of the EMP, impedance and Pulse Current Injection (PCI) testing is established to study the vulnerability of the grid control devices. The impedance of the grid control devices is accurately measured using impedance analyzers with different frequency ranges. Then the voltage and current responses are tested based on the PCI testing. The vulnerability experiments based on two grid control devices are carried out. And the comparison results reveal that most ports would be damaged under EC8, and some ports can survive under EC5 according to the calculated PCI response and cumulative energy. The results can provide a reference for the future design of control devices and the strategic resilience of power grids.

Qiu, Wei↗

Dispenser Reliability: Materials R&D. A Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) Report

Dispensers are the top cause of maintenance events and down-time at hydrogen fueling stations. In an effort to help characterize and enable improvements in dispenser reliability, an extensive accelerated lifetime testing set-up was designed and built at NREL involving components typically part of dispensing operations at fueling stations. Device Under Test (DUTs) included different components such as normally open valves, normally closed valves, fueling nozzles, breakaways devices and filters. Conditions of testing included pressures, and flow rates similar to light duty fuel cell electric vehicles fueling at -40°C, and -20°C for thousands of cycles in hydrogen. Tested components (failed and non-failed) were disassembled at SNL and polymeric O-rings were carefully retrieved and cataloged for chemical and physical characterization. Data collected was compared to similar O-rings from unexposed or non-tested components for hydrogen effects, and failure modes. Degradation analyses, based on select polymer chemistries common across all component types, their location within components, visual assessment of damage coupled with strong hydrogen effects from chemical characterization, was completed and presented to NREL and DOE. Overall, the failure rate amongst the components was not as high as expected for the test conditions. Among the component types tested, breakaways were the most susceptible to damage under these test conditions, with fueling nozzles a close second. The proper combination of selection of the right polymer and optimum component design was found to make a strong difference in component reliability under severe dispenser operating conditions. Physical degradation of polymers, rather than chemical changes due to low temperature hydrogen exposure, is more prevalent as failure mode for these test conditions. The nature and the extent of the degradation was much less at -20°C as compared to -40°C. The damage and failure rates were higher at lower temperatures than at higher test temperatures. As expected, increasing the number of cycles at the lowest test temperature (-40°C) increased damage. This indicates that cycling at the low temperature of -40°C required by SAE J2601 can reduce component life in fuel dispensing operations

08 HYDROGEN↗

Programmed pulsing to initiation apparatus for electroexplosive testing

An electroexplosive device accepts electrical energy and converts it into heat which is used to initiate a primary explosion. Disadvantages of the current electroexplosive testing method have led to the development of a new testing procedure which is based on a principle of programmed pulsing to initiation. A series of stepwise increasing energy pulses is applied to the device which is tested until the initiation of the explosion occurs. The test principle is discussed along with the design of the apparatus.

Rosenthal, L. A.↗