Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct simulation Monte Carlo methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

SU-G-BRC-10: Feasibility of a Web-Based Monte Carlo Simulation Tool for Dynamic Electron Arc Radiotherapy (DEAR)

Purpose: DEAR is a radiation therapy technique utilizing synchronized motion of gantry and couch during delivery to optimize dose distribution homogeneity and penumbra for treatment of superficial disease. Dose calculation for DEAR is not yet supported by commercial TPSs. The purpose of this study is to demonstrate the feasibility of using a web-based Monte Carlo (MC) simulation tool (VirtuaLinac) to calculate dose distributions for a DEAR delivery. Methods: MC simulations were run through VirtuaLinac, which is based on the GEANT4 platform. VirtuaLinac utilizes detailed linac head geometry and material models, validated phase space files, and a voxelized phantom. The input was expanded to include an XML file for simulation of varying mechanical axes as a function of MU. A DEAR XML plan was generated and used in the MC simulation and delivered on a TrueBeam in Developer Mode. Radiographic film wrapped on a cylindrical phantom (12.5 cm radius) measured dose at a depth of 1.5 cm and compared to the simulation results. Results: A DEAR plan was simulated using an energy of 6 MeV and a 3×10 cm{sup 2} cut-out in a 15×15 cm{sup 2} applicator for a delivery of a 90° arc. The resulting data were found to provide qualitative and quantitative evidence that the simulation platform could be used as the basis for DEAR dose calculations. The resulting unwrapped 2D dose distributions agreed well in the cross-plane direction along the arc, with field sizes of 18.4 and 18.2 cm and penumbrae of 1.9 and 2.0 cm for measurements and simulations, respectively. Conclusion: Preliminary feasibility of a DEAR delivery using a web-based MC simulation platform has been demonstrated. This tool will benefit treatment planning for DEAR as a benchmark for developing other model based algorithms, allowing efficient optimization of trajectories, and quality assurance of plans without the need for extensive measurements.

60 APPLIED LIFE SCIENCES↗

Quantum Monte Carlo method for pairing phenomena: Supercounterfluid of two-species Bose gases in optical lattices

We study the supercounterfluid (SCF) states in the two-component hard-core Bose-Hubbard model on a square lattice, using the quantum Monte Carlo method based on the worm (directed-loop) algorithm. Since the SCF state is a state of a pair condensation characterized by <a{sup {dagger}b}>{ne}0,<a>=0, and <b>=0, where a and b are the order parameters of the two components, it is important to study behaviors of the pair-correlation function <a{sub i}b{sub i}{sup {dagger}a}{sub j}{sup {dagger}b}{sub j}>. For this purpose, we propose a choice of the worm head for calculating the pair-correlation function. From this pair correlation, we confirm the Kosterlitz-Thouless character of the SCF phase. The simulation efficiency is also improved in the SCF phase.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-290: Secondary Dose Monitoring Using Scintillating Fibers in Proton Therapy of Prostate Cancer: A Geant4 Monte Carlo Simulation

Purpose: To monitor the secondary dose distribution originating from a water phantom during proton therapy of prostate cancer using scintillating fibers. Methods: The Geant4 Monte Carlo toolkit version 9.6.p02 was used to simulate prostate cancer proton therapy based treatments. Two cases were studied. In the first case, 8 × 8 = 64 equally spaced fibers inside three 4 × 4 × 2.54 cmm{sup 3} DuPont™ Delrin blocks were used to monitor the emission of secondary particles in the transverse (left and right) and distal regions relative to the beam direction. In the second case, a scintillating block with a thickness of 2.54 cm and equal vertical and longitudinal dimensions as the water phantom was used. Geometrical cuts were used to extract the energy deposited in each fiber and the scintillating block. Results: The transverse dose distributions from secondary particles in both cases agree within <5% and with a very good symmetry. The energy deposited not only gradually increases as one moves from the peripheral row fibers towards the center of the block (aligned with the center of the prostate) but also decreases as one goes from the frontal to distal region of the block. The ratio of the doses from the prostate to the ones in the middle two rows of fibers showed a linear relationship with a slope (−3.55±2.26) × 10−5 MeV per treatment Gy. The distal detectors recorded a very small energy deposited due to water attenuation. Conclusion: With a good calibration and the ability to define a good correlation between the dose to the external fibers and the prostate, such fibers can be used for real time dose verification to the target.

60 APPLIED LIFE SCIENCES↗

Ettringite hysteresis under sorption from molecular simulations

Highlights: • Hybrid Grand Canonical Monte Carlo (GCMC) and Molecular Dynamics (MD) simulations are performed. • Anisotropic large strain coefficient of crystal shrinkage of ettringite is provided. • Entropy increases when ettringite converts into metaettringite. • Sorption-induced stress may lead to columns collapse upon drying. • H-bonds involving OH groups in columns play a role in hysteresis. The response of ettringite under sorption is critical for the utilization of this mineral as an energy storage material and to understand the concrete durability problems associated with ettringite formation. We report molecular simulations directly sampling the osmotic ensemble to understand the sorption processes and structural changes in ettringite-metaettringite transition. Desorption branch and sorption-induced volume changes from simulations agree with the experiments. The structural changes at low relative humidity are analyzed, revealing for the first time details of metaettringite structure. The reversibility under sorption observed experimentally is captured by simulation in the ettringite domain. The reversibility in the conversion of metaettringite into ettringite is not captured by the direct simulations in the osmotic ensemble due to the large volume changes associated with ettringite desorption. Finally, we discuss the role of hydrogen bonds on the hysteresis in ettringite.

36 MATERIALS SCIENCE↗

Heat loads to divertor nearby components from secondary radiation evolved during plasma instabilities

A fundamental issue in tokamak operation related to power exhaust during plasma instabilities is the understanding of heat and particle transport from the core plasma into the scrape-off layer and to plasma-facing materials. During abnormal and disruptive operation in tokamaks, radiation transport processes play a critical role in divertor/edge-generated plasma dynamics and are very important in determining overall lifetimes of the divertor and nearby components. This is equivalent to or greater than the effect of the direct impact of escaped core plasma on the divertor plate. We have developed and implemented comprehensive enhanced physical and numerical models in the upgraded HEIGHTS package for simulating detailed photon and particle transport in the evolved edge plasma during various instabilities. The paper describes details of a newly developed 3D Monte Carlo radiation transport model, including optimization methods of generated plasma opacities in the full range of expected photon spectra. Response of the ITER divertor's nearby surfaces due to radiation from the divertor-developed plasma was simulated by using actual full 3D reactor design and magnetic configurations. We analyzed in detail the radiation emission spectra and compared the emission of both carbon and tungsten as divertor plate materials. The integrated 3D simulation predicted unexpectedly high damage risk to the open stainless steel legs of the dome structure in the current ITER design from the intense radiation during a disruption on the tungsten divertor plate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimized collision-specific parameters for binary mixtures of nitrogen, oxygen, argon, and helium

Recently proposed collision-specific parameters for direct simulation Monte Carlo simulations are tested for binary mixtures of nitrogen, oxygen, and argon. Near ambient conditions, the traditional collision-averaged parameters are highly accurate, whereas the collision-specific parameters are not. The simulated transport using the collision-averaged parameters for mixtures with helium, however, is found to be inaccurate. Therefore, we propose a novel method to determine molecular parameters by combining the Chapman–Enskog theory with empirical mixing rules and experimental data. The optimized parameters are highly accurate for the binary mixtures of nitrogen, oxygen, and argon and greatly improve the simulated transport for the helium mixtures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Directional Detector Response Function for Anisotropic Detectors

For a radiation detector that is not isotropic, a directional detector response is needed to accurately account for the variation in a detector’s behavior depending on the incoming particle direction. The concept of the detector response function has been extended to include particle direction using a set of pregenerated detector responses based on the orientation of the incoming radiation and the detector. This directional detector response function (DDRF) then can be applied to the flux and current tallies computed by a Monte Carlo simulation. Validation of the new approach has been done by comparing simulated count rates processed with the DDRF to measured count rates taken with a 5.08 × 10.16 × 40.64-cm NaI(Tl) detector. The comparisons show that the applied method produces good agreement with both background and source measurements with a 137 Cs source. Furthermore, separation of the detector response generation from Monte Carlo particle transport calculations provides greater flexibility in locating single or multiple detectors without any interference in the model and also enables simulation of various models using the same detector response without the need for generating additional detector responses if the same detector is being used.

42 ENGINEERING↗

Neutron-neutron angular correlations in spontaneous fission of Cf 252 and Pu 240

Background: Angular anisotropy has been observed between prompt neutrons emitted during the fission process. Such an anisotropy arises because the emitted neutrons are boosted along the direction of the parent fragment. Purpose: To measure the neutron-neutron angular correlations from the spontaneous fission of 252 Cf and 240 Pu oxide samples using a liquid scintillator array capable of pulse-shape discrimination. To compare these correlations to simulations combining the Monte Carlo radiation transport code MCNPX with the fission event generator FREYA. Method: Two different analysis methods were used to study the neutron-neutron correlations with varying energy thresholds. The first is based on setting a light output threshold while the second imposes a time-of-flight cutoff. The second method has the advantage of being truly detector independent. Results: The neutron-neutron correlation modeled by FREYA depends strongly on the sharing of the excitation energy between the two fragments. The measured asymmetry enabled us to adjust the FREYA parameter x in 240 Pu , which controls the energy partition between the fragments and is so far inaccessible in other measurements. The 240 Pu data in this analysis was the first available to quantify the energy partition for this isotope. The agreement between data and simulation is overall very good for 252 Cf ( sf ) and 240 Pu ( sf ). Conclusions: The asymmetry in the measured neutron-neutron angular distributions can be predicted by FREYA. The shape of the correlation function depends on how the excitation energy is partitioned between the two fission fragments. Lastly, experimental data suggest that the lighter fragment is disproportionately excited.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Critical Relaxation of a Three-Dimensional Fully Frustrated Ising Model

Critical relaxation from the low-temperature ordered state of the three-dimensional fully frustrated Ising model on a simple cubic lattice is studied by the short-time dynamics method. Cubic systems with periodic boundary conditions and linear sizes of L = 32, 64, 96, and 128 in each crystallographic direction are studied. Calculations were carried out by the Monte Carlo method using the standard Metropolis algorithm. The static critical exponents for the magnetization and correlation radius and the dynamic critical exponents are calculated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Radiation Damage in Nuclear Fuel for Advanced Burner Reactors: Modeling and Experimental Validation

The consortium has completed its existence and we are here highlighting work and accomplishments. As outlined in the proposal, the objective of the work was to advance the theoretical understanding of advanced nuclear fuel materials (oxides) toward a comprehensive modeling strategy that incorporates the different relevant scales involved in radiation damage in oxide fuels. Approaching this we set out to investigate and develop a set of directions: 1) Fission fragment and ion trajectory studies through advanced molecular dynamics methods that allow for statistical multi-scale simulations. This work also includes an investigation of appropriate interatomic force fields useful for the energetic multi-scale phenomena of high energy collisions; 2) Studies of defect and gas bubble formation through electronic structure and Monte Carlo simulations; and 3) an experimental component for the characterization of materials such that comparisons can be obtained between theory and experiment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron production from interactions of high-intensity ultrashort pulse laser with a planar deuterated polyethylene target

The deuteron acceleration from a planar uniform deuterated polyethylene (CD{sub 2}) target was studied with a two-dimensional electromagnetic particle-in-cell method in the ultrarelativistic regime for peak laser intensities between 10{sup 23} and 10{sup 25} W/m{sup 2}. Under identical conditions the deuteron energy and angular distributions are very different when compared to that produced from a double-layer target. The neutron production from D(d,n)-{sup 3}He nuclear fusion reactions was also investigated with a three-dimensional Monte Carlo ion beam-target deposition model. The neutron yield and its angular distribution were studied as a function of peak laser intensity and laser pulse duration. A neutron yield of 10{sup 4}-10{sup 6} neutrons per Joule laser energy is inferred from simulations of a 4 {mu}m thick planar uniform CD{sub 2} target. The angular scattering of neutrons is found to be nonisotropic and has a significant component in the forward (laser propagation) direction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Parametric Study of the Adjoint Flux Calculation for TDKENO

TDKENO is a time-dependent transport code designed to simulate reactor transients. One application is to study experiments performed at the Transient Reactor Test Facility (TREAT) at the Idaho National Laboratory (INL). TDKENO solves the time-dependent, three-dimensional Boltzmann transport equation with explicit representation of delayed neutrons. Instead of directly integrating this equation, the Improved Quasi Static (IQS) method is employed. This involves factoring the neutron flux into two components - a rapidly varying (in time) amplitude equation and a slowly varying shape equation. These are solved separately on different time scales. The shape equation is solved using the Monte Carlo transport code KENO, from Oak Ridge National Laboratory's SCALE code package. Using the Monte Carlo method to solve the shape equation is computationally intensive, but the operation is only performed when needed - namely when the reactor system is undergoing a significant change. The amplitude equation is solved deterministically. This operation contains the time dependence and can be calculated relatively quickly, resulting in computational savings. TDKENO begins by solving the adjoint form of the transport equation for use as a weighting function. It uses this adjoint flux for multiple aspects of the simulation, including the calculation of all of the point kinetics parameters . The flux shape is found by solving a modified form of the transport equation in 'forward' mode. This paper examines the effect the adjoint weighting function has on the solution. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimizing mini-ridge filter thickness to reduce proton treatment times in a spot-scanning synchrotron system

Purpose: Study the contributors to treatment time as a function of Mini-Ridge Filter (MRF) thickness to determine the optimal choice for breath-hold treatment of lung tumors in a synchrotron-based spot-scanning proton machine. Methods: Five different spot-scanning nozzles were simulated in TOPAS: four with MRFs of varying maximal thicknesses (6.15–24.6 mm) and one with no MRF. The MRFs were designed with ridges aligned along orthogonal directions transverse to the beam, with the number of ridges (4–16) increasing with MRF thickness. The material thickness given by these ridges approximately followed a Gaussian distribution. Using these simulations, Monte Carlo data were generated for treatment planning commissioning. For each nozzle, standard and stereotactic (SR) lung phantom treatment plans were created and assessed for delivery time and plan quality. Results: Use of a MRF resulted in a reduction of the number of energy layers needed in treatment plans, decreasing the number of synchrotron spills needed and hence the treatment time. For standard plans, the treatment time per field without a MRF was 67.0 ± 0.1 s, whereas three of the four MRF plans had treatment times of less than 20 s per field; considered sufficiently low for a single breath-hold. For SR plans, the shortest treatment time achieved was 57.7 ± 1.9 s per field, compared to 95.5 ± 0.5 s without a MRF. There were diminishing gains in time reduction as the MRF thickness increased. Dose uniformity of the PTV was comparable across all plans; however, when the plans were normalized to have the same coverage, dose conformality decreased with MRF thickness, as measured by the lung V20%. Conclusions: Single breath-hold treatment times for plans with standard fractionation can be achieved through the use of a MRF, making this a viable option for motion mitigation in lung tumors. For stereotactic plans, while a MRF can reduce treatment times, multiple breath-holds would still be necessary due to the limit imposed by the proton extraction time. To balance treatment time and normal tissue dose, the ideal MRF choice was shown to be the thinnest option that is able to achieve the desired breath-hold timing.

60 APPLIED LIFE SCIENCES↗

Monte Carlo uncertainty estimation for an oscillating-vessel viscosity measurement

This paper discusses the initial design and evaluation of a high temperature viscosity measurement system with the focus on the uncertainty assessment. Numerical simulation of the viscometer is used to estimate viscosity uncertainties through the Monte Carlo method. The simulation computes the system response for a particular set of inputs (viscosity, moment of inertia, spring constant and hysteretic damping), and the viscosity is calculated using two methods: the Roscoe approximate solution and a numerical-fit method. For numerical fitting, a residual function of the logarithmic decay of oscillation amplitude and oscillation period is developed to replace the residual function of angular oscillation, which is mathematically stiff. The results of this study indicate that the method using computational solution of the equations and fitting for the parameters should be used, since it almost always out-performs the Roscoe approximation in uncertainty. The hysteretic damping and spring stiffness uncertainties translate into viscosity uncertainties almost directly, whereas the moment of inertial and vessel-height uncertainties are magnified approximately two-fold. As the hysteretic damping increases, so does the magnification of its uncertainty, therefore it should be minimized in the system design. The result of this study provides a general guide for the design and application of all oscillation-vessel viscosity measurement systems.

99 GENERAL AND MISCELLANEOUS↗

Measurement of temperature of a dusty plasma from its configuration

A new concept called “configurational temperature” is introduced in the context of dusty plasma, where the temperature of the dust particles submerged in the plasma can be measured directly from the positional information of the individual dust particles and the interaction potential between the dust grains. This method does not require the velocity information of individual particles, which is a key parameter to measure the dust temperature in the conventional method. The technique is initially tested using two-dimensional (2D) OpenMP parallel molecular dynamics and Monte Carlo simulation and then compared with the temperature evaluated from experimental data. The experiment have been carried out in the Dusty Plasma Experimental (DPEx) device, where a 2D stationary plasma crystal of melamine formaldehyde particles is formed in the cathode sheath of a DC glow discharge argon plasma. The kinetic temperature of the dust is calculated using the standard particle image velocimetry technique at different pressures. An extended simulation result for the three-dimensional case is also presented, which can be employed for the temperature measurement of a three-dimensional dust crystal in laboratory devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct Monte Carlo Simulations of Chemical Equilibrium Composition of Molecular Fluid Mixtures Under Shock Conditions

A new Monte Carlo simulation method is implemented which holds the number and kind of atoms constant rather than the number and kind of molecules for a molecular fluid mixture. Chemical reactions are allowed as a correlated move of atoms such as an interchange of atoms between molecules. Equilibrium chemical composition is determined as an average over the simulation along with equation of state quantities. Results are presented for N 2 + O 2 → 2NO at 30GPa and 3000K. The equilibrium composition is shown to be sensitive to the potentials between unlike species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-T-656: Monte Carlo Study On Air Activation Around a Medical Electron Linac

Purpose: In high energy photon therapy, several radiation protection issues result from photonuclear reactions. The activation of air - directly by photonuclear reactions as well as indirectly by capture of photoneutrons generated inside the linac head - is a major point of concern for the medical staff. The purpose of this study was to estimate the annual effective dose to medical workers due to activated air around a medical high energy electron linac by means of Monte Carlo simulations. Methods: The treatment head of a Varian Clinac in 18 MV-X mode as well as the surrounding concrete bunker were modeled and the radiation transport was simulated using the Monte Carlo code FLUKA, starting from the primary electron striking the bremsstrahlung target. The activation yields in air from photo-disintegration of O-16 and N-14 nuclei as well as from neutron capture on Ar-40 nuclei were obtained from the simulations. The activation build-up, radioactive decay and air ventilation were studied using a mathematical model. The annual effective dose to workers was estimated by using published isotope specific conversion factors. Results: The oxygen and nitrogen activation yields were in contrast to the argon activation yield found to be field size dependent. The impact of the treatment room ventilation on the different air activation products was investigated and quantified. An estimate with very conservative assumptions gave an annual effective dose to workers of < 1 mSv/a. Conclusion: From the results of this study it can be concluded that the contribution of air activation to the radiation exposure to medical workers should be negligible in modern photon therapy, especially when it is compared to the dose due to prompt neutrons and the activation of heavy solid materials such as the jaws and the collimators inside the linac head.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP2-05: Development of a Thimble Calorimeter for Absorbed Dose to Water Characterized in MV Photons

Purpose: To develop a thimble sized polystyrene calorimeter for use from kV to MV photons, as a primary reference standard for applications from diagnostic CT imaging to therapy beam dose determination. Methods: A polystyrene calorimeter about 1.5 cm diameter embedded with small thermistors was characterized in a 6 MV photon beam from a clinical accelerator at 5 nominal dose rates from 0.8 to 4 Gy/min. Irradiations were delivered with beam on/off cycles first at 60 s and then at 20 s. Two sets of phantom conditions were evaluated: 1) in a 30 cm diameter polyethylene cylinder, and 2) in 10 cm depth of a 30 cm water phantom. The temperature waveforms were recorded and analyzed for temperature rise, arriving at a dose to polystyrene. This value is compared with the result of measurements under identical conditions using an ionization chamber calibrated for absorbed dose to water. Monte Carlo simulations were performed on the measurement systems to estimate such a ratio. Results: The ratio of the dose determined by the calorimeter to the dose reported by the ionization chamber was aggregated from all 5 dose rates. The 60 s results show a much elevated response in both phantoms compared to their respective expected results based on simulation. This deviation was reduced when the on/off cycles were shortened to 20 s. This behavior was possibly due to the heat conduction effects in the small calorimeter body. Finite element modeling is being conducted to simulate this effect. Conclusion: A small solid plastic calorimeter offers the convenience of a portable absorbed dose standard based on direct measurement of energy deposition, but comes at the expense of heat transfer complications which need to be characterized. This work offers preliminary evidence of the behavior and quantitative assessment of the issues to be resolved in future investigations.

60 APPLIED LIFE SCIENCES↗