Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Optimal Portfolio Design of Distributed Energy Resources on Puerto Rico Distribution Feeders with Long Outages after Hurricane Maria

This work details a project to design reliable, resilient, and cost-effective networked microgrids considering grid constraints and resilience metrics focused on Puerto Rico distribution feeder locations with long outages after Hurricane Maria. The project consisted primarily of modeling and simulation tasks that accomplished the following objectives: 1. Selected 10 distribution feeder models in vulnerable areas. The sample feeders are geographically distributed across Puerto Rico and vary in length to capture the wide variety of feeders on the island. 2. Determined the optimal location and sizing of distributed energy resources (DERs) on the identified distribution feeders. The systems considered as part of the microgrid solutions were solar photovoltaic (PV), battery energy storage systems (BESS) and distributed fossil fuel generation (DFFG). 3. Estimated the cost-benefit of the proposed DER portfolios. 4. Provided a set of final recommendations that inform decision making on how to do targeted planning analysis for microgrids that can supply energy to critical infrastructures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

GPR Surveys across a Prototype Surface Barrier to Determine Temporal and Spatial Variations in Soil Moisture Content

Engineered surface barriers are expected to play a critical role in the closure of waste sites within the DOE complex and currently require monitoring to verify performance. The most comprehensive approach to assess performance is by water balance evaluation, which requires knowledge of the soil water storage. However, water storage measurements are still made mostly by point sensors and as result field-scale estimates are subject to much uncertainty. The objective of this study was to assess the viability of using ground penetrating radar (GPR) to monitor changes in soil moisture distribution, and therefore water storage, at multiple scales. Profiles were collected at four times during the year March, May, September and the following January to track the decrease in storage from the spring to the summer followed by the increase in the winter. A series of 40-m long profiles were collected using 100-Mhz antennas with a sample interval of 0.8 ns and 500 samples per trace in a 400-ns window. A common midpoint (CMP) survey was first used to determine an optimal antenna separation (3.5 m) after which data were collected using a wide-offset reflection geometry. Travel times were used to calculate the electromagnetic velocities which were then used to calculate water content using the Topp’s equation. Changes in the GPR response were easily observed over the course of the study and indicated spatial differences in moisture, which owing to the relatively uniform soil, can be attributed to differences in water removal by evapotranspiration. Water content also showed a strong seasonal strong seasonal dependence that correlate well with seasonal changes in precipitation and plant water uptake. An investigation of the effects of soil water content on the amplitude of the ground wave showed weaker amplitudes in the drier spring and summer months than in the winter suggesting a correlation between amplitude and water content. Results show that GPR can provide accurate non-invasive estimates of spatial and temporal changes in water content and therefore soil water storage.

54 ENVIRONMENTAL SCIENCES↗

Optimal deployment of thermal energy storage under diverse economic and climate conditions

This paper presents an investigation of the economic benefit of thermal energy storage (TES) for cooling, across a range of economic and climate conditions. Chilled water TES systems are simulated for a large office building in four distinct locations, Miami in the U.S.; Lisbon, Portugal; Shanghai, China; and Mumbai, India. Optimal system size and operating schedules are determined using the optimization model DER-CAM, such that total cost, including electricity and amortized capital costs are minimized. The economic impacts of each optimized TES system is then compared to systems sized using a simple heuristic method, which bases system size as fraction (50percent and 100percent) of total on-peak summer cooling loads. Results indicate that TES systems of all sizes can be effective in reducing annual electricity costs (5percent-15percent) and peak electricity consumption (13percent-33percent). The investigation also indentifies a number of criteria which drive TES investment, including low capital costs, electricity tariffs with high power demand charges and prolonged cooling seasons. In locations where these drivers clearly exist, the heuristically sized systems capture much of the value of optimally sized systems; between 60percent and 100percent in terms of net present value. However, in instances where these drivers are less pronounced, the heuristic tends to oversize systems, and optimization becomes crucial to ensure economically beneficial deployment of TES, increasing the net present value of heuristically sized systems by as much as 10 times in some instances.

25 ENERGY STORAGE↗

Understanding I/O workload characteristics of a Peta-scale storage system

Understanding workload characteristics is critical for optimizing and improving the performance of current systems and software, and architecting new storage systems based on observed workload patterns. In this paper, we characterize the I/O workloads of scientific applications of one of the world's fastest high performance computing (HPC) storage cluster, Spider, at the Oak Ridge Leadership Computing Facility (OLCF). OLCF flagship petascale simulation platform, Titan, and other large HPC clusters, in total over 250 thousands compute cores, depend on Spider for their I/O needs. We characterize the system utilization, the demands of reads and writes, idle time, storage space utilization, and the distribution of read requests to write requests for the Peta-scale Storage Systems. From this study, we develop synthesized workloads, and we show that the read and write I/O bandwidth usage as well as the inter-arrival time of requests can be modeled as a Pareto distribution. We also study the I/O load imbalance problems using I/O performance data collected from the Spider storage system.

I/O↗

Watersheds and stream networks viewed longitudinally: Example insights from novel spatial portrayals of watershed characteristics

Abstract Longitudinal depictions of watershed structure and characteristics, including topography, stream networks, wetlands, ground water levels, and land use, can provide watershed knowledge and understanding unavailable from standard plan view maps. Three case studies provide examples of knowledge gained by applying longitudinal views of stream networks, watershed hydrologic behavior, and land use distributions. Longitudinal views of mountain stream networks show extreme variability in the slope‐area relationships of low Strahler order streams, large discontinuities in drainage area (large parts of drainage area space are absent in networks), and large variations in network curvature. Longitudinal views of a groundwater‐dominated headwater watershed increase the inference available from limited groundwater observations and clearly reveal how groundwater connections affect the permanence of surface water features and the distribution of vadose zone storage in the landscape. Plotting land uses longitudinally illuminates and allows a quantitative analysis of how land uses are distributed relative to topographic position. Viewing watersheds and stream networks longitudinally can provide new insights into watershed forms and processes and motivate new questions and research.

60 APPLIED LIFE SCIENCES↗

End-Use Load Profiles for the U.S. Building Stock: Market Needs, Use Cases, and Data Gaps

States and utilities are developing increasingly ambitious energy goals. Part of the solution to meeting these goals is improving electric grid flexibility. This includes shifting electric demand to align with grid needs. Thus, identifying and using building energy efficiency and other distributed energy resources to produce the highest grid value requires highly resolved, accurate and accessible electricity end-use load profiles (EULPs). EULPs quantify how and when energy is used. Currently, few accurate and accessible end-use load profiles are available for utilities, public utility commissions, state energy offices and other stakeholders to use to prioritize investment and value energy efficiency, demand response, distributed generation and energy storage. High-quality EULPs are also critical for determining the time-sensitive value of efficiency and other distributed energy resources, and the widespread adoption of grid-interactive efficient buildings (GEBs).For example, EULPs can be used to accurately forecast energy savings in buildings or identify energy activities that can be shifted to different times of the day. This report serves as the first-year deliverable for a multiyear U.S. Department of Energy-funded project, End-Use Load Profiles for the U.S. Building Stock, that intends to produce a set of highly resolved EULPs of the U.S. residential and commercial building stock. The project team, made up of researchers from the National Renewable Energy Laboratory (NREL), Lawrence Berkeley National Laboratory (LBNL), and Argonne National Laboratory, ultimately will use calibrated physics-based building energy models to create these EULPs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling Distributed Generation in California

In support of analysis for the biennial Integrated Energy Policy Report, the California Energy Commission and the National Renewable Energy Laboratory have partnered to study the growth of distributed energy resources in California. This study involves the use of National Renewable Energy Laboratory's Distributed Generation Market Demand model, available at https://www.nrel.gov/analysis/dgen/, to project statewide adoption of distributed photovoltaics and paired storage. Key outcomes of the collaboration include: • Improved representation of California building stock, load profiles, historical adoption, and tariffs, including the net billing tariff, in the dGen model; • Trained CEC staff members to use and adapt the dGen model for their specific needs; • Developed a methodology for representing emerging consumer segments to potentially adopt distributed energy resources, including low-income, multifamily, and renter-occupied buildings; • Forecasted solar photovoltaic and paired storage growth in California using a common set of modeling parameters. This report describes the multiyear effort, which includes a discussion of: • Methodology and data employed in adapting the Distributed Generation Market Demand model for California to forecast solar photovoltaic and storage statewide through 2040; • Steps taken to modify the base model to forecast solar photovoltaic adoption in emerging market segments such as multifamily or renter-occupied homes or both; • Future enhancements of the model.

14 SOLAR ENERGY↗

Net-Zero Carbon Microgrids

The microgrid concept has been effective in creating aggregations of distributed energy resources—generation, storage and loads—for resiliency, in the form of energy security. The success of microgrids in bringing energy security to a wide range of customers—from individual residences to commercial and industrial installations to military bases—has been exemplified during power disruptions and extended outages due to extreme weather events, cybersecurity attacks, and equipment failures. Now microgrids have an opportunity to meet the challenges of climate change and contribute to a carbon-free power delivery system. The transition to net-zero starts within microgrids themselves. In fact, today’s microgrids are largely dominated by generators using fossil fuels, natural gas and diesel, with high greenhouse gas emissions. In short, the transition to net-zero means replacing fossil fueled generators with renewable generation in microgrids. This transition is extended by including new dispatchable generation technologies that are 100% carbon-free and that offer additional advantage of a more-dependable and sustainable source of energy and power. Basically, the decarbonization of microgrids requires three elements: 1) maximizing generation from renewable energy resources, 2) management of storage and flexible loads to balance the variability and intermittency of renewable energy resources, and 3) introducing new clean power sources, including hydrogen-based generation and small modular reactors. This report affirms a need for specific focus by governmental agencies at national, regional, and local levels to establish technology, policy, and investment in this area. The intention of the Net-Zero Microgrid (NZM) Program is to inform these constituencies with cross-cutting research and tools for the reduction of GHG in microgrids – to net-zero in the near term eventually to zero in the longer term. The NZM Program is committed to achieving decarbonization for resiliency and for providing clean energy at the local or distribution level, from remote communities to underserved communities, and large industrial and military facilities. The NZM Planning and Design Platform is a core tool to be developed as an early deliverable of the NZM Program because only a fully integrated microgrid-design approach will ensure maximum carbon reduction in energy production.

13 HYDRO ENERGY↗

Background Information on the Power Quality Requirements in IEEE Std 1547-2018

The revised Institute of Electrical and Electronics Engineers (IEEE) 1547-2018, Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces, was published in April 2018. This standard is one of the foundational documents in the United States needed for integrating distributed energy resources (DERs), including solar energy systems, and energy storage systems with the electric distribution grid. The revised standard contains 11 chapters (clauses) and 8 annexes that comprise 136 pages. The revision is significantly different from the 2003 version, and it contains new concepts and new technical requirements. Each clause specifies information or requirements that apply to certain aspects that are important to the interconnection of DERs to the electric power system. Implementing the requirements necessitates a careful study of the underlying technical concepts and requires appropriate information to calculate relevant settings and configurations. This document provides informative material on the requirements related to electrical power quality in IEEE Std 1547-2018, with the intent to equip the reader with basic knowledge and background information to improve understanding and use of the requirements specified.

14 SOLAR ENERGY↗

The Los Angeles 100% Renewable Energy Study (LA100): Chapter 7. Distribution System Analysis

The City of Los Angeles has set ambitious goals to transform its electricity supply, aiming to achieve a 100% renewable energy power system by 2045, along with aggressive electrification targets for buildings and vehicles. To reach these goals, and assess the implications for jobs, electricity rates, the environment, and environmental justice, the Los Angeles City Council passed a series of motions directing the Los Angeles Department of Water and Power (LADWP) to determine the technical feasibility and investment pathways of a 100% renewable energy portfolio standard. The Los Angeles 100% Renewable Energy Study (LA100) is a first-of-its-kind objective, rigorous, and science-based power systems analysis to determine what investments could be made to achieve these goals. The LA100 final report is presented as a collection of 12 chapters and an executive summary, each of which is available as an individual download. This chapter summarizes the growth in distribution-connected energy resources and provides a detailed review of impacts to the distribution grid of growth in customer electricity demand, solar, and storage, as well as required distribution grid upgrades and associated costs.

100% Renewable↗

Where and When Does Solar Plus Storage Make Sense for Commercial Buildings?

As the capital cost of battery energy storage systems (BESS) declines, opportunities for commercial buildings to achieve net savings through peak demand management and energy arbitrage are emerging. National Renewable Energy Laboratory researchers modeled energy storage project economics - with and without accompanying solar photovoltaic systems - using local utility rates, ASHRAE climate zones, and solar intensity data to identify regions where these systems deliver life cycle savings now and in future cost scenarios.

battery energy storage systems↗

Distributed Energy Resources On-Site Optimization for Commercial Buildings with Electric and Thermal Storage Technologies

The addition of storage technologies such as flow batteries, conventional batteries, and heat storage can improve the economic as well as environmental attractiveness of on-site generation (e.g., PV, fuel cells, reciprocating engines or microturbines operating with or without CHP) and contribute to enhanced demand response. In order to examine the impact of storage technologies on demand response and carbon emissions, a microgrid's distributed energy resources (DER) adoption problem is formulated as a mixed-integer linear program that has the minimization of annual energy costs as its objective function. By implementing this approach in the General Algebraic Modeling System (GAMS), the problem is solved for a given test year at representative customer sites, such as schools and nursing homes, to obtain not only the level of technology investment, but also the optimal hourly operating schedules. This paper focuses on analysis of storage technologies in DER optimization on a building level, with example applications for commercial buildings. Preliminary analysis indicates that storage technologies respond effectively to time-varying electricity prices, i.e., by charging batteries during periods of low electricity prices and discharging them during peak hours. The results also indicate that storage technologies significantly alter the residual load profile, which can contribute to lower carbon emissions depending on the test site, its load profile, and its adopted DER technologies.

25 ENERGY STORAGE↗

Understanding Customer Dissatisfaction with Underutilized Distributed File Servers

An important trend in the design of storage subsystems is a move toward direct network attachment. Network-attached storage offers the opportunity to off-load distributed file system functionality from dedicated file server machines and execute many requests directly at the storage devices. For this strategy to lead to better performance, as perceived by users, the response time of distributed operations must improve. In this paper we analyze measurements of an Andrew file system (AFS) server that we recently upgraded in an effort to improve client performance in our laboratory. While the original server's overall utilization was only about 3%, we show how burst loads were sufficiently intense to lead to period of poor response time significant enough to trigger customer dissatisfaction. In particular, we show how, after adjusting for network load and traffic to non-project servers, 50% of the variation in client response time was explained by variation in server central processing unit (CPU) use. That is, clients saw long response times in large part because the server was often over-utilized when it was used at all. Using these measures, we see that off-loading file server work in a network-attached storage architecture has to potential to benefit user response time. Computational power in such a system scales directly with storage capacity, so the slowdown during burst period should be reduced.

Riedel, Erik↗

Electricity Cost for Electric Vehicle Fast Charging

As the adoption of plug-in electric vehicles (PEVs) continues to grow, so does the development of a network of fast-charging stations to support long-distance travel and provide alternatives to residential and workplace charging. Fast charging, however, could be significantly more expensive than residential/workplace charging, mainly due to high power consumption and low utilization. This poster highlights NREL's review of the current cost of electricity for PEV fast charging in the United States as well as its evaluation of alternative charting options to mitigate electricity costs for public fast-charging stations via on-site electricity generation (from photovoltaics) and storage.

25 ENERGY STORAGE↗

LA100 Equity Strategies. Chapter 8: Equitable Rooftop Solar Access and Benefits

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. This chapter focuses on analysis of customer-sited rooftop solar and storage as a means to reduce electricity bills for low- and moderate-income (LMI) households, multifamily building residents, and renters, who traditionally lack access to bill savings from rooftop solar. Specifically, NREL modeled customer-sited solar and storage adoption using the Distributed Generation Market Demand (dGen™)1 model through 2035 and developed scenarios to identify programs or policies that could support equitable access to bill savings from rooftop solar or solar-plus-storage. Scenarios tested include a direct-install program for LMI customers, net metering for LMI customers, and equitable distribution of benefits from installing solar between owners and renters of renter-occupied buildings. Research was guided by input from the community engagement process, and equity strategies are presented in alignment with that guidance.

14 SOLAR ENERGY↗