Search NASA⌕ Search

SEARCH · Search NASA

Results for “error correction.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

SU-E-J-34: Setup Accuracy in Spine SBRT Using CBCT 6D Image Guidance in Comparison with 6D ExacTrac

Purpose Volumetric information of the spine captured on CBCT can potentially improve the accuracy in spine SBRT setup that has been commonly performed through 2D radiographs. This work evaluates the setup accuracy in spine SBRT using 6D CBCT image guidance that recently became available on Varian systems. Methods ExacTrac radiographs have been commonly used for Spine SBRT setup. The setup process involves first positioning patients with lasers followed by localization imaging, registration, and repositioning. Verification images are then taken providing the residual errors (ExacTracRE) before beam on. CBCT verification is also acquired in our institute. The availability of both ExacTrac and CBCT verifications allows a comparison study. 41 verification CBCT of 16 patients were retrospectively registered with the planning CT enabling 6D corrections, giving CBCT residual errors (CBCTRE) which were compared with ExacTracRE. Results The RMS discrepancies between CBCTRE and ExacTracRE are 1.70mm, 1.66mm, 1.56mm in vertical, longitudinal and lateral directions and 0.27°, 0.49°, 0.35° in yaw, roll and pitch respectively. The corresponding mean discrepancies (and standard deviation) are 0.62mm (1.60mm), 0.00mm (1.68mm), −0.80mm (1.36mm) and 0.05° (0.58°), 0.11° (0.48°), −0.16° (0.32°). Of the 41 CBCT, 17 had high-Z surgical implants. No significant difference in ExacTrac-to-CBCT discrepancy was observed between patients with and without the implants. Conclusion Multiple factors can contribute to the discrepancies between CBCT and ExacTrac: 1) the imaging iso-centers of the two systems, while calibrated to coincide, can be different; 2) the ROI used for registration can be different especially if ribs were included in ExacTrac images; 3) small patient motion can occur between the two verification image acquisitions; 4) the algorithms can be different between CBCT (volumetric) and ExacTrac (radiographic) registrations.

60 APPLIED LIFE SCIENCES↗

Diagnosing multiplicative error with lensing magnification of type Ia supernovae

Weak lensing causes spatially coherent fluctuations in the flux of Type Ia supernovae (SNe Ia). This lensing magnification allows for weak lensing measurement independent of cosmic shear. It is free of the shape measurement errors associated with cosmic shear and can therefore be used to diagnose and calibrate multiplicative error. Although this lensing magnification is difficult to accurately measure in auto correlation, its cross correlation with cosmic shear and galaxy distribution in an overlapping area can be measured to a significantly higher accuracy. Therefore, these cross correlations can put useful constraints on multiplicative error, and the obtained constraint is free of cosmic variance in the weak lensing field. We present two methods implementing this idea and estimate their performances. We find that, with ∼1 million SNe Ia that can be achieved with the proposed D2k survey with the LSST telescope, a multiplicative error of ∼0.5% for source galaxies at z{sub s}∼1 can be detected and a larger multiplicative error can be corrected to the level of 0.5%. It is therefore a promising approach to control the multiplicative error to the sub-percent level required for stage IV projects. The combination of the two methods even has the potential to diagnose and calibrate galaxy intrinsic alignment, which is another major systematic error in cosmic shear cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-P-31: Dosimetric Effects of Roll and Pitch Corrections Using Robotic Table

Purpose: To quantify the dosimetric effect of roll and pitch corrections being performed by two types of robotic tables available at our institution: BrainLabTM 5DOF robotic table installed at VERO (BrainLab&MHI) dedicated SBRT linear accelerator and 6DOF robotic couch by IBA Proton Therapy with QFixTM couch top. Methods: Planning study used a thorax phantom (CIRSTM), scanned at 4DCT protocol; targets (IGTV, PTV) were determined according to the institutional lung site-specific standards. 12 CT sets were generated with Pitch and Roll angles ranging from −4 to +4 degrees each. 2 table tops were placed onto the scans according to the modality-specific patient treatment workflows. The pitched/rolled CT sets were fused to the original CT scan and the verification treatment plans were generated (12 photon SBRT plans and 12 proton conventional fractionation lung plans). Then the CT sets were fused again to simulate the effect of patient roll/pitch corrections by the robotic table. DVH sets were evaluated for all cases. Results: The effect of not correcting the phantom position for roll/pitch in photon SBRT cases was reducing the target coverage by 2% as maximum; correcting the positional errors by robotic table varied the target coverage within 0.7%. in case of proton treatment, not correcting the phantom position led to the coverage loss up to 4%, applying the corrections using robotic table reduced the coverage variation to less than 2% for PTV and within 1% for IGTV. Conclusion: correcting the patient position by using robotic tables is highly preferable, despite the small dosimetric changes introduced by the devices.

60 APPLIED LIFE SCIENCES↗

Understanding Mixed Precision GEMM with MPGemmFI: Insights into Fault Resilience

Emerging deep learning workloads urgently need fast general matrix multiplication (GEMM). Thus, one of the critical features of machine-learning-specific accelerators such as NVIDIA Tensor Cores, AMD Matrix Cores, and Google TPUs is the support of mixed-precision enabled GEMM. For DNN models, lower-precision FP data formats and computation offer acceptable correctness but significant performance, area, and memory footprint improvement. While promising, the mixed-precision computation on error resilience remains unexplored. To this end, we develop a fault injection framework that systematically injects fault into the mixed-precision computation results. We investigate how the faults affect the accuracy of machine learning applications. Based on the characteristics of error resilience, we offer lightweight error detection and correction solutions that significantly improve the overall model accuracy by 75% if the models experience hardware faults. The solutions can be efficiently integrated into the accelerator's pipelines.

Fang, Bo↗

Perturbative readout-error mitigation for near-term quantum computers

Readout errors on near-term quantum computers can introduce significant error to the empirical probability distribution sampled from the output of a quantum circuit. These errors can be mitigated by classical postprocessing given the access of an experimental response matrix that describes the error associated with the measurement of each computational basis state. However, the resources required to characterize a complete response matrix and to compute the corrected probability distribution scale exponentially with the number of qubits, n . In this work, we modify standard matrix inversion techniques using perturbative approximations with significantly reduced complexity and bounded error when the likelihood of high-order bit-flip events is strongly suppressed. Given a characteristic error rate q , we discuss a method to recover the probability of the all-zeros bit string p 0 by sampling only a small subspace of the response matrix before inverting readout error, resulting in a relative speedup of poly [ 2 n / ( n w ) ] , which we motivate using a simplified error model for which the approximation incurs only O ( q w ) error for some integer w . We then provide a generalized technique to efficiently recover full output distributions with O ( q w ) error in the perturbative limit. These approximate techniques for readout-error correction may greatly accelerate near-term quantum computing applications.

97 MATHEMATICS AND COMPUTING↗

Author Correction: Microbial Metagenomes Across a Complete Phytoplankton Bloom Cycle: High-Resolution Sampling Every 4 Hours Over 22 Days

In the version of this article initially published, two errors in authorship were made. First, Tatiana Rynearson of the School of Oceanography, University of Rhode Island was mistakenly omitted from the final author list. Second, Kurt LaButti of the Joint Genome Institute was mistakenly omitted from the final author list and replaces Alicia Clum due to a staffing change at the Joint Genome Institute. These authorship omissions were not identified until after the work had been published. We are updating the authorship to appropriately recognize the contributions of these authors. The error has been corrected in the PDF and HTML versions of the article.

59 BASIC BIOLOGICAL SCIENCES↗

The impact of curation errors in the PDBBind Database on machine learning predictions of protein–protein binding affinity

The PDBBind database has been widely utilized for the computational prediction of protein–protein binding affinities. While the accuracy of the PDBBind-curated equilibrium dissociation constants (K D ) has been reported for the protein–ligand subset of the PDBBind database, the curation accuracy has not been reported for the protein–protein subset. Here, we present a detailed manual analysis for the subset of PDBBind records with PubMed Central Open Access primary publications and find that ~19% of these records had K D values that were not supported by their primary publications. The impact of these putative curation errors on the machine learning-based prediction of K D from experimental protein–protein 3D structures was evaluated and correcting the curation errors improved the Pearson correlation coefficient between measured and random forest-predicted log 10 (K D ) values by ~8 percentage points. This finding underscores the importance of dataset accuracy for computational modelling and highlights the need for more stringent curation processes when extracting information from the scientific literature.

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-J-114: A Practical Hybrid Method for Improving the Quality of CT-CBCT Deformable Image Registration for Head and Neck Radiotherapy

Purpose: Accurate deformable image registration (DIR) between CT and CBCT in H&N is challenging. In this study, we propose a practical hybrid method that uses not only the pixel intensities but also organ physical properties, structure volume of interest (VOI), and interactive local registrations. Methods: Five oropharyngeal cancer patients were selected retrospectively. For each patient, the planning CT was registered to the last fraction CBCT, where the anatomy difference was largest. A three step registration strategy was tested; Step1) DIR using pixel intensity only, Step2) DIR with additional use of structure VOI and rigidity penalty, and Step3) interactive local correction. For Step1, a public-domain open-source DIR algorithm was used (cubic B-spline, mutual information, steepest gradient optimization, and 4-level multi-resolution). For Step2, rigidity penalty was applied on bony anatomies and brain, and a structure VOI was used to handle the body truncation such as the shoulder cut-off on CBCT. Finally, in Step3, the registrations were reviewed on our in-house developed software and the erroneous areas were corrected via a local registration using level-set motion algorithm. Results: After Step1, there were considerable amount of registration errors in soft tissues and unrealistic stretching in the posterior to the neck and near the shoulder due to body truncation. The brain was also found deformed to a measurable extent near the superior border of CBCT. Such errors could be effectively removed by using a structure VOI and rigidity penalty. The rest of the local soft tissue error could be corrected using the interactive software tool. The estimated interactive correction time was approximately 5 minutes. Conclusion: The DIR using only the image pixel intensity was vulnerable to noise and body truncation. A corrective action was inevitable to achieve good quality of registrations. We found the proposed three-step hybrid method efficient and practical for CT/CBCT registrations in H&N. My department receives grant support from Industrial partners: (a) Varian Medical Systems, Palo Alto, CA, and (b) Philips HealthCare, Best, Netherlands.

60 APPLIED LIFE SCIENCES↗

Correcting thermal-emission-induced detector saturation in infrared spectroscopy

We found that temperature-dependent infrared spectroscopy measurements (i.e., reflectance or transmittance) using a Fourier-transform spectrometer can have substantial errors, especially for elevated sample temperatures and collection using an objective lens. These errors can arise as a result of partial detector saturation due to thermal emission from the measured sample reaching the detector, resulting in nonphysical apparent reduction of reflectance or transmittance with increasing sample temperature. Here, we demonstrate that these temperature-dependent errors can be corrected by implementing several levels of optical attenuation that enable convergence testing of the measured reflectance or transmittance as the thermal-emission signal is reduced, or by applying correction factors that can be inferred by looking at the spectral regions where the sample is not expected to have a substantial temperature dependence.

47 OTHER INSTRUMENTATION↗

Machine Learning-Based Upscaling of Finite-Size Molecular Dynamics Diffusion Simulations for Binary Fluids

Molecular diffusion coefficients calculated using molecular dynamics (MD) simulations suffer from finite-size (i.e., finite box size and finite particle number) effects. Results from finite-sized MD simulations can be upscaled to infinite simulation size by applying a correction factor. For self-diffusion of single-component fluids, this correction has been well-studied by many researchers including Yeh and Hummer (YH); for binary fluid mixtures, a modified YH correction was recently proposed for correcting MD-predicted Maxwell–Stephan (MS) diffusion rates. In this study we use both empirical and machine learning methods to identify improvements to the finite-size correction factors for both self-diffusion and MS diffusion of binary Lennard-Jones (LJ) fluid mixtures. Using artificial neural networks (ANNs), the error in the corrected LJ fluid diffusion is reduced by an order of magnitude versus existing YH corrections, and the ANN models perform well for mixtures with large dissimilarities in size and interaction energies where the YH correction proves insufficient.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-J-29: Automatic Image Registration Performance of Three IGRT Systems for Prostate Radiotherapy

Purpose: To compare the performance of an automatic image registration algorithm on image sets collected on three commercial image guidance systems, and explore its relationship with imaging parameters such as dose and sharpness. Methods: Images of a CIRS Virtually Human Male Pelvis phantom (VHMP) were collected on the CBCT systems of Varian TrueBeam/OBI and Elekta Synergy/XVI linear accelerators, across a range of mAs settings; and MVCT on a Tomotherapy Hi-ART accelerator with a range of pitch. Using the 6D correlation ratio algorithm of XVI, each image was registered to a mask of the prostate volume with a 5 mm expansion. Registrations were repeated 100 times, with random initial offsets introduced to simulate daily matching. Residual registration errors were calculated by correcting for the initial phantom set-up error. Automatic registration was also repeated after reconstructing images with different sharpness filters. Results: All three systems showed good registration performance, with residual translations <0.5mm (1σ) for typical clinical dose and reconstruction settings. Residual rotational error had larger range, with 0.8°, 1.2° and 1.9° for 1σ in XVI, OBI and Tomotherapy respectively. The registration accuracy of XVI images showed a strong dependence on imaging dose, particularly below 4mGy. No evidence of reduced performance was observed at the lowest dose settings for OBI and Tomotherapy, but these were above 4mGy. Registration failures (maximum target registration error > 3.6 mm on the surface of a 30mm sphere) occurred in 5% to 10% of registrations. Changing the sharpness of image reconstruction had no significant effect on registration performance. Conclusions: Using the present automatic image registration algorithm, all IGRT systems tested provided satisfactory registrations for clinical use, within a normal range of acquisition settings.

60 APPLIED LIFE SCIENCES↗

Erratum to: Data Fusion to Support Integrated Nuclear Detonation Detection [Slides]

The original document (LA-UR-22-29547) contained minor equation errors that approximate correct equations that couple the multi-sensor, serial system detector thresholds for a seismic Rayleigh wave detector and an acoustic energy detector. Those errors appeared on slides 62-67. This erratum associates the following slides with the erroneous slides. The numbers of the erroneous slides are marked at the upper right in small text in orange. A result of those errors over-predict the performance of the two-sensor serial network, that is, the former document provides an optimistic estimate of system performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct Writing of X-ray Gratings Using Zone-Plate-Array Lithography (ZPAL)

With the objective of providing the synchrotron and free-electron-laser communities with rapid turnaround and low prices for the highest quality and most advanced gratings and diffractive-focusing optics, LumArray has made specific improvements to its ZP-150 maskless photolithography system, which is based on Zone-Plate-Array Lithography (ZPAL), a technology unique to Lumarray. ZPAL’s advantages include an ability to correct in software for systematic patterning errors. Emphasis was placed on interferometric measurements of various contributors to patterning errors using Fizeau interferometry and a Mireau technique that was developed specifically for measuring errors within a micron-scale area. Average line-placement error was reduced below 20 nm using both pattern-file distortion and address-grid modification. The preferred implementation, address-grid modification, is hardware-based and requires no user intervention while also correcting more types of error. With continued iteration and refinement of the error measurements, we anticipate achieving global line-placement error below10nm. In order to investigate line-edge smoothness and high-frequency line-placement errors, a scheme for inspecting micron-sized areas was invented and implemented based on Mireau interferometry. This enabled the various contributions to be separately evaluated and measured. These included: exposure-dose variation, pattern-writing strategy and errors in the positioning of the microlenses. Deleterious crosstalk between microlenses was minimized via a pattern-dependent software modification. The impact of exposure threshold was revealed and adjustment made. The impact of address-grid fineness on line-edge roughness was likewise shown. Lastly, techniques were developed to measure and correct errors in the positioning of microlenses within the array. We expect final calibration of microlens positions to within 5nm.

42 ENGINEERING↗

On Compatible Transfer Operators in Nonsymmetric Algebraic Multigrid

The standard goal for an effective algebraic multigrid (AMG) algorithm is to develop relaxation and coarse-grid correction schemes that attenuate complementary error modes. In the nonsymmetric setting, coarse-grid correction &#x3A0; will almost certainly be nonorthogonal (and divergent) in any known standard product, meaning ∥&#x3A0;∥ > 1. This introduces a new consideration, that one wants coarse-grid correction to be as close to orthogonal as possible, in an appropriate norm. In addition, due to nonorthogonality, &#x3A0; may actually amplify certain error modes that are in the range of interpolation. Relaxation must then not only be complementary to interpolation, but also rapidly eliminate any error amplified by the nonorthogonal correction, or the algorithm may diverge. Here this paper develops analytic formulae on how to construct “compatible” transfer operators in nonsymmetric AMG such that ∥&#x3A0;∥ = 1 in some standard matrix-induced norm. Discussion is provided on different options for the norm in the nonsymmetric setting, the relation between “ideal” transfer operators in different norms, and insight into the convergence of nonsymmetric reduction-based AMG.

97 MATHEMATICS AND COMPUTING↗

Two-body potential model based on cosine series expansion for ionic materials

There is a method to construct a two-body potential model for ionic materials with a Fourier series basis and we examine it. For this method, the coefficients of cosine basis functions are uniquely determined by solving simultaneous linear equations to minimize the sum of weighted mean square errors in energy, force and stress, where first-principles calculation results are used as the reference data. As a validation test of the method, potential models for magnesium oxide are constructed. The mean square errors appropriately converge with respect to the truncation of the cosine series. This result mathematically indicates that the constructed potential model is sufficiently close to the one that is achieved with the non-truncated Fourier series and demonstrates that this potential virtually provides minimum error from the reference data within the two-body representation. The constructed potential models work appropriately in both molecular statics and dynamics simulations, especially if a two-step correction to revise errors expected in the reference data is performed, and the models clearly outperform two existing Buckingham potential models that were tested. Moreover, the good agreement over a broad range of energies and forces with first-principles calculations should enable the prediction of materials behavior away from equilibrium conditions, such as a system under irradiation.

36 MATERIALS SCIENCE↗

Iterative Stress Reconstruction Algorithm to Estimate Three-Dimensional Residual Stress Fields in Manufactured Components

Residual stress (RS) significantly impacts the mechanical performance of components. Measurement of RS often provides incomplete data in terms of components of stress and spatial density. Employing such fields in finite element simulations results in significant modification of the field to achieve equilibrium and compatibility among strains. To overcome this, an iterative stress reconstruction algorithm (ISRA) is developed to estimate 3D RS fields that satisfy equilibrium, are stress component-wise complete, and represent the characterized data sampled. An Al 7075-T651 plate and an additively manufactured (AM) A36 steel wall are considered for RS reconstruction using measurement data from the literature. A maximum variation of ~2.5 MPa in the Al plate, and ~10 MPa in the steel wall are observed between the reconstructed and measured stresses. Furthermore, unknown stress components emerge and reach significant magnitudes (upto ~2.3 MPa in the Al plate and ~45 MPa in the AM wall) during ISRA. Indeed, it is found that minor errors in measurement or data processing are eliminated through the physical requirements during ISRA. Employing a reconstructed RS field is hence not just more accurate given its compatibility, but it additionally corrects for minor errors in measurement. Furthermore, it is found that spatially dense measurement data result in convergence with fewer iterations. Finally, although ISRA yields a nonunique solution dependent on boundary conditions, measurement errors, fitting errors, and mesh density, it accommodates for uncertainties and inaccuracies in measurement, as opposed to failing to reach a physically realistic converged solution.

42 ENGINEERING↗

STUDY OF CALIBRATION OF SOLAR RADIO SPECTROMETERS AND THE QUIET-SUN RADIO EMISSION

This work presents a systematic investigation of the influence of weather conditions on the calibration errors by using Gaussian fitness, least chi-square linear fitness, and wavelet transform to analyze the calibration coefficients from observations of the Chinese Solar Broadband Radio Spectrometers (at frequency bands of 1.0–2.0 GHz, 2.6–3.8 GHz, and 5.2–7.6 GHz) during 1997–2007. We found that calibration coefficients are influenced by the local air temperature. Considering the temperature correction, the calibration error will reduce by about 10%–20% at 2800 MHz. Based on the above investigation and the calibration corrections, we further study the radio emission of the quiet Sun by using an appropriate hybrid model of the quiet-Sun atmosphere. The results indicate that the numerical flux of the hybrid model is much closer to the observation flux than that of other ones.

79 ASTRONOMY AND ASTROPHYSICS↗