Search NASA⌕ Search

SEARCH · Search NASA

Results for “error fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Shear testing of fiber reinforced metal matrix composites

This paper outlines the elements of a combined experimental/analytical methodology for accurate shear characterization of unidirectional composites in the linear and nonlinear range, with particular attention devoted to metal matrix composites. It is illustrated that consistent results can be obtained for a large class of composites from two commonly employed shear test methods currently in use by composites researchers when the influence of various factors that affect the determination of the actual shear response is properly analyzed. These factors include the effects of material anisotropy, specimen geometry, manner of load introduction, and test fixture design on the stress and deformation fields in the test section of off-axis and Iosipescu specimens. Common errors associated with the measurement of deformation fields and calculation of stress fields are discussed and quantified. Particular problems in the determination of the shear response of unidirectional boron/aluminum using the Iosipescu test are illustrated and discussed.

Pindera, Marek-Jerzy↗

NASA airborne Doppler lidar program: Data characteristics of 1981

The first flights of the NASA/Marshall airborne CO2 Doppler lidar wind measuring system were made during the summer of 1981. Successful measurements of two-dimensional flow fields were made to ranges of 15 km from the aircraft track. The characteristics of the data obtained are examined. A study of various artifacts introduced into the data set by incomplete compensation for aircraft dynamics is summarized. Most of these artifacts can be corrected by post processing, which reduces velocity errors in the reconstructed flow field to remarkably low levels.

Lee, R. W.↗

Modeling protein structures from predicted contacts with modern molecular dynamics potentials: accuracy, sensitivity, and refinement

Protein structure prediction has become increasingly popular and successful in recent years. An essential step for fragment-free, template-free methods is the generation of a final three-dimensional protein model from a set of predicted amino acid contacts that are often described by interresidue pairwise atomic distances. Here we explore the use of modern, open-source molecular dynamics (MD) engines, which have been continually developed over the last three decades with all-atom Hamiltonians to model biomolecular structure and dynamics, to generate accurate protein structures starting from a set of inferred pairwise distances. Additionally, the ability of MD empirical physical potentials to correct inaccuracies in the predicted geometries is tested. We rigorously characterize the effect of modeling parameters on results, the effect of different amounts of error in the predicted distances on the final structures, and test the ability of post-processing analysis to sort the best models out of a set of statistical replicas. We find that with exact distances and with noisy distances, the method can produce excellent structural models, and that the molecular dynamics force field seems to help correct errors in distance predictions, resisting the effects of applied noise.

Davidson, Russ↗

Commissioning a small-field biological irradiator using point, 2D, and 3D dosimetry techniques

Purpose: To commission a small-field biological irradiator, the XRad225Cx from Precision x-Ray, Inc., for research use. The system produces a 225 kVp x-ray beam and is equipped with collimating cones that produce both square and circular radiation fields ranging in size from 1 to 40 mm. This work incorporates point, 2D, and 3D measurements to determine output factors (OF), percent-depth-dose (PDD) and dose profiles at multiple depths. Methods: Three independent dosimetry systems were used: ion-chambers (a farmer chamber and a micro-ionisation chamber), 2D EBT2 radiochromic film, and a novel 3D dosimetry system (DLOS/PRESAGE registered ). Reference point dose rates and output factors were determined from in-air ionization chamber measurements for fields down to {approx}13 mm using the formalism of TG61. PDD, profiles, and output factors at three separate depths (0, 0.5, and 2 cm), were determined for all field sizes from EBT2 film measurements in solid water. Several film PDD curves required a scaling correction, reflecting the challenge of accurate film alignment in very small fields. PDDs, profiles, and output factors were also determined with the 3D DLOS/PRESAGE registered system which generated isotropic 0.2 mm data, in scan times of 20 min. Results: Surface output factors determined by ion-chamber were observed to gradually drop by {approx}9% when the field size was reduced from 40 to 13 mm. More dramatic drops were observed for the smallest fields as determined by EBT{approx}18% and {approx}42% for the 2.5 mm and 1 mm fields, respectively. PRESAGE registered and film output factors agreed well for fields <20 mm (where 3D data were available) with mean deviation of 2.2% (range 1%-4%). PDD values at 2 cm depth varied from {approx}72% for the 40 mm field, down to {approx}55% for the 1 mm field. EBT and PRESAGE registered PDDs agreed within {approx}3% in the typical therapy region (1-4 cm). At deeper depths the EBT curves were slightly steeper (2.5% at 5 cm). These results indicate good overall consistency between ion-chamber, EBT2 and PRESAGE registered measured OFs, PDDs, and profiles. Conclusions: The combination of independent 2D and 3D measurements was found to be valuable to ensure accurate and comprehensive commissioning. Film measurements were time consuming and challenging due to the difficulty of film alignment in small fields. PRESAGE registered 3D measurements were comprehensive and efficient, because alignment errors are negligible, and all parameters for multiple fields could be obtained from a single dosimeter and scan. However, achieving accurate superficial data (within 4 mm) is not yet feasible due to optical surface artifacts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the bounce-averaging of scattering rates and the calculation of bounce period

For many applications to planetary magnetospheres and elsewhere in the Universe, it is desirable to average physical quantities such as particle and plasma transport coefficients over a charged particle's bounce motion between magnetic mirror points along field lines. In this paper, we perform such bounce-averaging in a way that avoids singularities in the integrands of expressions that arise in calculations of this sort. Our method applies in principle to an almost arbitrary magnetic field model. We illustrate the advantage of using our method for removing the integrand's singularity through a change of variables (rather than by truncating the integral over latitude at points progressively nearer to the mirror point) by computing the component of the bounce-averaged momentum-space diffusion tensor in a dipolar magnetic field both ways for resonance interaction of geomagnetically trapped relativistic (1 MeV) electrons with field-aligned whistler-mode plasma waves at L = 6 (a field line that passes near synchronous altitude). Moreover, we develop improved analytical approximations for particle bounce periods in a dipolar magnetic field by minimizing mean square errors with respect to expansion coefficients in algebraic representations of the bounce period.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Classical Non-Markovian Noise in Symmetry-Preserving Quantum Dynamics

In quantum dynamics, symmetries are vital for identifying and assessing conserved quantities that govern the evolution of a quantum system. When promoted to the open quantum system setting, dynamical symmetries can be negatively altered by system-environment interactions, thus, complicating their analysis. Previous work on noisy symmetric quantum dynamics has focused on the Markovian setting, despite the ubiquity of non-Markovian noise in a number of widely used quantum technologies. Here, in this Letter, we develop a framework for quantifying the impact of non-Markovian noise on symmetric quantum evolution via root space decompositions and the filter function formalism. We demonstrate analytically that symmetry-preserving noise maintains the symmetric subspace, while nonsymmetric noise leads to highly specific leakage errors that are block diagonal in the symmetry representation. We support our findings with numerical studies of a transverse-field Ising model and a quantum error detecting code subject to spatiotemporally correlated multiaxis noise. Our results are broadly applicable, providing new analytic insights into the control and characterization of open quantum system dynamics.

decoherence↗

Error growth in operational ECMWF forecasts

A parameterization scheme used at the European Centre for Medium Range Forecasting to model the average growth of the difference between forecasts on consecutive days was extended by including the effect of error growth on forecast model deficiencies. Error was defined as the difference between the forecast and analysis fields during the verification time. Systematic and random errors were considered separately in calculating the error variance for a 10 day operational forecast. A good fit was obtained with measured forecast errors and a satisfactory trend was achieved in the difference between forecasts. Fitting six parameters to forecast errors and differences that were performed separately for each wavenumber revealed that the error growth rate grew with wavenumber. The saturation error decreased with the total wavenumber and the limit of predictability, i.e., when error variance reaches 95 percent of saturation, decreased monotonically with the total wavenumber.

Kalnay, E.↗

Optics correction for the multi-pass FFAG ERL machine eRHIC

Gradient errors in the multi-pass Fixed Field Alternating Gradient (FFAG) Energy Recovery Linac (ERL) machine, eRHIC, distort the beam orbit and therefore cause emittance increase. The localization and correction of gradient errors are essential for an effective orbit correction and emittance preservation. In this report, the methodology and simulation of optics correction for the multi-pass FFAG ERL machine eRHIC will be presented.

43 PARTICLE ACCELERATORS↗

Technical Report: Evaluation of peripheral dose for flattening filter free photon beams

Purpose: To develop a comprehensive peripheral dose (PD) dataset for the two unflattened beams of nominal energy 6 and 10 MV for use in clinical care. Methods: Measurements were made in a 40 × 120 × 20 cm{sup 3} (width × length × depth) stack of solid water using an ionization chamber at varying depths (dmax, 5, and 10 cm), field sizes (3 × 3 to 30 × 30 cm{sup 2}), and distances from the field edge (5–40 cm). The effects of the multileaf collimator (MLC) and collimator rotation were also evaluated for a 10 × 10 cm{sup 2} field. Using the same phantom geometry, the accuracy of the analytic anisotropic algorithm (AAA) and Acuros dose calculation algorithm was assessed and compared to the measured values. Results: The PDs for both the 6 flattening filter free (FFF) and 10 FFF photon beams were found to decrease with increasing distance from the radiation field edge and the decreasing field size. The measured PD was observed to be higher for the 6 FFF than for the 10 FFF for all field sizes and depths. The impact of collimator rotation was not found to be clinically significant when used in conjunction with MLCs. AAA and Acuros algorithms both underestimated the PD with average errors of −13.6% and −7.8%, respectively, for all field sizes and depths at distances of 5 and 10 cm from the field edge, but the average error was found to increase to nearly −69% at greater distances. Conclusions: Given the known inaccuracies of peripheral dose calculations, this comprehensive dataset can be used to estimate the out-of-field dose to regions of interest such as organs at risk, electronic implantable devices, and a fetus. While the impact of collimator rotation was not found to significantly decrease PD when used in conjunction with MLCs, results are expected to be machine model and beam energy dependent. It is not recommended to use a treatment planning system to estimate PD due to the underestimation of the out-of-field dose and the inability to calculate dose at extended distances due to the limits of the dose calculation matrix.

60 APPLIED LIFE SCIENCES↗

A study of the local pressure field in turbulent shear flow and its relation to aerodynamic noise generation

Work during the period of this report has been in three areas: (1) pressure transducer error analysis, (2) fluctuating velocity and pressure measurements in the NASA Lewis 6-inch diameter quiet jet facility, and (3) measurement analysis. A theory was developed and experimentally verified to quantify the pressure transducer velocity interference error. The theory and supporting experimental evidence show that the errors are a function of the velocity field's turbulent structure. It is shown that near the mixing layer center the errors are negligible. Turbulent velocity and pressure measurements were made in the NASA Lewis quiet jet facility. Some preliminary results are included.

Jones, B. G.↗

Noise in x-ray grating-based phase-contrast imaging

Purpose: Grating-based x-ray phase-contrast imaging is a fast developing new modality not only for medical imaging, but as well for other fields such as material sciences. While these many possible applications arise, the knowledge of the noise behavior is essential. Methods: In this work, the authors used a least squares fitting algorithm to calculate the noise behavior of the three quantities absorption, differential phase, and dark-field image. Further, the calculated error formula of the differential phase image was verified by measurements. Therefore, a Talbot interferometer was setup, using a microfocus x-ray tube as source and a Timepix detector for photon counting. Additionally, simulations regarding this topic were performed. Results: It turned out that the variance of the reconstructed phase is only dependent of the total number of photons used to generate the phase image and the visibility of the experimental setup. These results could be evaluated in measurements as well as in simulations. Furthermore, the correlation between absorption and dark-field image was calculated. Conclusions: These results provide the understanding of the noise characteristics of grating-based phase-contrast imaging and will help to improve image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time catheter tracking for high-dose-rate prostate brachytherapy using an electromagnetic 3D-guidance device: A preliminary performance study

Purpose: In order to increase the accuracy and speed of catheter reconstruction in a high-dose-rate (HDR) prostate implant procedure, an automatic tracking system has been developed using an electromagnetic (EM) device (trakSTAR, Ascension Technology, VT). The performance of the system, including the accuracy and noise level with various tracking parameters and conditions, were investigated. Methods: A direct current (dc) EM transmitter (midrange model) and a sensor with diameter of 1.3 mm (Model 130) were used in the trakSTAR system for tracking catheter position during HDR prostate brachytherapy. Localization accuracy was assessed under both static and dynamic analyses conditions. For the static analysis, a calibration phantom was used to investigate error dependency on operating room (OR) table height (bottom vs midposition vs top), sensor position (distal tip of catheter vs connector end of catheter), direction [left-right (LR) vs anterior-posterior (AP) vs superior-inferior (SI)], sampling frequency (40 vs 80 vs 120 Hz), and interference from OR equipment (present vs absent). The mean and standard deviation of the localization offset in each direction and the corresponding error vectors were calculated. For dynamic analysis, the paths of five straight catheters were tracked to study the effects of directions, sampling frequency, and interference of EM field. Statistical analysis was conducted to compare the results in different configurations. Results: When interference was present in the static analysis, the error vectors were significantly higher at the top table position (3.3 {+-} 1.3 vs 1.8 {+-} 0.9 mm at bottom and 1.7 {+-} 1.0 mm at middle, p < 0.001), at catheter end position (3.1 {+-} 1.1 vs 1.4 {+-} 0.7 mm at the tip position, p < 0.001), and at 40 Hz sampling frequency (2.6 {+-} 1.1 vs 2.4 {+-} 1.5 mm at 80 Hz and 1.8 {+-} 1.1 at 160 Hz, p < 0.001). So did the mean offset errors in the LR direction (-1.7 {+-} 1.4 vs 0.4 {+-} 0.5 mm in AP and 0.8 {+-} 0.8 mm in SI directions, p < 0.001). The error vectors were significantly higher with surrounding interference (2.2 {+-} 1.3 mm) vs without interference (1.0 {+-} 0.7 mm, p < 0.001). An accuracy of 1.6 {+-} 0.2 mm can be reached when using optimum configuration (160 Hz at middle table position). When interference was present in the dynamic tracking, the mean tracking errors in LR direction (1.4 {+-} 0.5 mm) was significantly higher than that in AP direction (0.3 {+-} 0.2 mm, p < 0.001). So did the mean vector errors at 40 Hz (2.1 {+-} 0.2 mm vs 1.3 {+-} 0.2 mm at 80 Hz and 0.9 {+-} 0.2 mm at 160 Hz, p < 0.05). However, when interference was absent, they were comparable in the both directions and at all sampling frequencies. An accuracy of 0.9 {+-} 0.2 mm was obtained for the dynamic tracking when using optimum configuration. Conclusions: The performance of an EM tracking system depends highly on the system configuration and surrounding environment. The accuracy of EM tracking for catheter reconstruction in a prostate HDR brachytherapy procedure can be improved by reducing interference from surrounding equipment, decreasing distance from transmitter to tracking area, and choosing appropriated sampling frequency. A calibration scheme is needed to further reduce the tracking error when the interference is high.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-TeP1-03: Beam Quality Correction Factors for Linear Accelerator with and Without Flattening Filter

Purpose: The impact of removing the flattening filter on absolute dosimetry based on IAEA’s TPR-398 and AAPM’s TG-51 was investigated in this study using Monte Carlo simulations. Methods: The EGSnrc software package was used for all Monte Carlo simulations performed in this work. Five different ionization chambers and nine linear accelerator heads have been modeled according to technical drawings. To generate a flattening filter free radiation field the flattening filter was replaced by a 2 mm thick aluminum layer. Dose calculation in a water phantom were performed to calculate the beam quality correction factor k{sub Q} as a function of the beam quality specifiers %dd(10){sub x}, TPR{sub 20,10} and mean photon and electron energies at the point of measurement in photon fields with (WFF) and without flattening filter (FFF). Results: The beam quality correction factor as a function of %dd(10){sub x} differs systematically between FFF and WFF beams for all investigated ionization chambers. The largest difference of 1.8% was observed for the largest investigated Farmer-type ionization chamber with a sensitive volume of 0.69 cm{sup 3}. For ionization chambers with a smaller nominal sensitive volume (0.015 – 0.3 cm{sup 3}) the deviation was less than 0.4% between WFF and FFF beams for %dd(10){sub x} > 62%. The specifier TPR{sub 20,10} revealed only a good correlation between WFF and FFF beams (< 0.3%) for low energies. Conclusion: The results confirm that %dd(10){sub x} is a suitable beam quality specifier for FFF beams with an acceptable bias. The deviation depends on the volume of the ionization chamber. Using %dd(10){sub x} to predict k{sub Q} for a large volume chamber in a FFF photon field may lead to not acceptable errors according to the results of this study. This bias may be caused by the volume effect due to the inhomogeneous photon fields of FFF linear accelerators.

60 APPLIED LIFE SCIENCES↗

High dose per fraction dosimetry of small fields with Gafchromic EBT2 film

Purpose: Small field dosimetry is prone to uncertainties due to the lack of electronic equilibrium and the use of the correct detector size relative to the field size measured. It also exhibits higher sensitivity to setup errors as well as large variation in output with field size and shape. Radiochromic film is an attractive method for reference dosimetry in small fields due to its ability to provide 2D dose measurements while having minimal impact on the dose distribution. Gafchromic EBT2 has a dose range of up to 40 Gy; therefore, it could potentially be useful for high dose reference dosimetry with high spatial resolution. This is a requirement in stereotactic radiosurgery deliveries, which deliver high doses per fraction to small targets. Methods: Targets of 4 mm and 12 mm diameters were treated to a minimum peripheral dose of 21 Gy prescribed to 80% of the maximum dose in one fraction. Target doses were measured with EBT2 film (both targets) and an ion chamber (12 mm target only). Measured doses were compared with planned dose distributions using profiles through the target and minimum peripheral dose coverage. Results: The measured target doses and isodose coverage agreed with the planned dose within {+-}1 standard deviation of three measurements, which were 2.13% and 2.5% for the 4 mm and 12 mm targets, respectively. Conclusions: EBT2 film is a feasible dosimeter for high dose per fraction reference 2D dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

An Efficient High-Order Solver for Diffusion Equations with Strong Anisotropy on Non-Anisotropy-Aligned Meshes

This paper concerns numerical solution of the diffusion equation with strong anisotropy on meshes not aligned with the anisotropic vector field. In order to resolve the numerical pollution for simulations on a non-anisotropy-aligned mesh and reduce the associated high computational cost we propose an effective preconditioner, extending our previous work. Similar to the anisotropy-aligned mesh case, we apply the auxiliary space preconditioning framework to design a preconditioner where a continuous finite element space is used as the auxiliary space for the discontinuous finite element space. The key component is an effective line smoother that can mitigate the high-frequency errors perpendicular to the magnetic field. We design a graph-based approach to find such a line smoother that is approximately perpendicular to the vector fields when the mesh does not align with the anisotropy. Finally, numerical experiments for several benchmark problems are presented, demonstrating the effectiveness and robustness of the proposed preconditioner when applied to Krylov iterative methods.

97 MATHEMATICS AND COMPUTING↗

REEXAMINATION OF INDUCTION HEATING OF PRIMITIVE BODIES IN PROTOPLANETARY DISKS

We reexamine the unipolar induction mechanism for heating asteroids originally proposed in a classic series of papers by Sonett and collaborators. As originally conceived, induction heating is caused by the 'motional electric field' that appears in the frame of an asteroid immersed in a fully ionized, magnetized solar wind and drives currents through its interior. However, we point out that classical induction heating contains a subtle conceptual error, in consequence of which the electric field inside the asteroid was calculated incorrectly. The problem is that the motional electric field used by Sonett et al. is the electric field in the freely streaming plasma far from the asteroid; in fact, the motional field vanishes at the asteroid surface for realistic assumptions about the plasma density. In this paper we revisit and improve the induction heating scenario by (1) correcting the conceptual error by self-consistently calculating the electric field in and around the boundary layer at the asteroid-plasma interface; (2) considering weakly ionized plasmas consistent with current ideas about protoplanetary disks; and (3) considering more realistic scenarios that do not require a fully ionized, powerful T Tauri wind in the disk midplane. We present exemplary solutions for two highly idealized flows that show that the interior electric field can either vanish or be comparable to the fields predicted by classical induction depending on the flow geometry. We term the heating driven by these flows 'electrodynamic heating', calculate its upper limits, and compare them to heating produced by short-lived radionuclides.

79 ASTRONOMY AND ASTROPHYSICS↗

Background Error Covariance Estimation Using Information from a Single Model Trajectory with Application to Ocean Data Assimilation

An attractive property of ensemble data assimilation methods is that they provide flow dependent background error covariance estimates which can be used to update fields of observed variables as well as fields of unobserved model variables. Two methods to estimate background error covariances are introduced which share the above property with ensemble data assimilation methods but do not involve the integration of multiple model trajectories. Instead, all the necessary covariance information is obtained from a single model integration. The Space Adaptive Forecast error Estimation (SAFE) algorithm estimates error covariances from the spatial distribution of model variables within a single state vector. The Flow Adaptive error Statistics from a Time series (FAST) method constructs an ensemble sampled from a moving window along a model trajectory.SAFE and FAST are applied to the assimilation of Argo temperature profiles into version 4.1 of the Modular Ocean Model (MOM4.1) coupled to the GEOS-5 atmospheric model and to the CICE sea ice model. The results are validated against unassimilated Argo salinity data. They show that SAFE and FAST are competitive with the ensemble optimal interpolation (EnOI) used by the Global Modeling and Assimilation Office (GMAO) to produce its ocean analysis. Because of their reduced cost, SAFE and FAST hold promise for high-resolution data assimilation applications.

Error Covariance↗

Background Error Covariance Estimation using Information from a Single Model Trajectory with Application to Ocean Data Assimilation into the GEOS-5 Coupled Model

An attractive property of ensemble data assimilation methods is that they provide flow dependent background error covariance estimates which can be used to update fields of observed variables as well as fields of unobserved model variables. Two methods to estimate background error covariances are introduced which share the above property with ensemble data assimilation methods but do not involve the integration of multiple model trajectories. Instead, all the necessary covariance information is obtained from a single model integration. The Space Adaptive Forecast error Estimation (SAFE) algorithm estimates error covariances from the spatial distribution of model variables within a single state vector. The Flow Adaptive error Statistics from a Time series (FAST) method constructs an ensemble sampled from a moving window along a model trajectory. SAFE and FAST are applied to the assimilation of Argo temperature profiles into version 4.1 of the Modular Ocean Model (MOM4.1) coupled to the GEOS-5 atmospheric model and to the CICE sea ice model. The results are validated against unassimilated Argo salinity data. They show that SAFE and FAST are competitive with the ensemble optimal interpolation (EnOI) used by the Global Modeling and Assimilation Office (GMAO) to produce its ocean analysis. Because of their reduced cost, SAFE and FAST hold promise for high-resolution data assimilation applications.

Data Assimilation↗