Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental setup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Adaptive center determination for effective suppression of ring artifacts in tomography images

Ring artifacts on tomogram slices hinder image interpretation. They are caused by minor variation in the response from individual elements in a two dimensional (2D) X-ray detector. Polar space decreases the suppression complexity by transforming the rings on the tomogram slice to linear stripes. However, it requires that the center of rings lie at the origin of polar transformation. If this is not the case, all methods employing polar space become ineffective. We developed a method based on Gaussian localization of the ring center in Hough parameter space to assign the origin for the polar transformation. Thus, obtained linear stripes can be effectively suppressed by already existing methods. This effectively suppresses ring artifacts in the data from a variety of experimental setups, sample types and also handles tomograms that are previously cropped. This approach functions automatically, avoids the need for assumptions and preserves fine details, all critical for synchrotron based nanometer resolution tomography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Video-rate terahertz electric-field vector imaging

We present an experimental setup to dramatically reduce a measurement time for obtaining spatial distributions of terahertz electric-field (E-field) vectors. The method utilizes the electro-optic sampling, and we use a charge-coupled device to detect a spatial distribution of the probe beam polarization rotation by the E-field-induced Pockels effect in a 〈110〉-oriented ZnTe crystal. A quick rotation of the ZnTe crystal allows analyzing the terahertz E-field direction at each image position, and the terahertz E-field vector mapping at a fixed position of an optical delay line is achieved within 21 ms. Video-rate mapping of terahertz E-field vectors is likely to be useful for achieving real-time sensing of terahertz vector beams, vector vortices, and surface topography. The method is also useful for a fast polarization analysis of terahertz beams.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nanoscale three-dimensional reconstruction of electric and magnetic stray fields around nanowires

Static electromagnetic stray fields around nanowires (NWs) are characteristic for a number of important physical effects such as field emission or magnetic force microscopy. Consequently, an accurate characterization of these fields is of high interest and electron holographic tomography (EHT) is unique in providing tomographic 3D reconstructions at nm spatial resolution. However, several limitations of the experimental setup and the specimen itself are influencing EHT. Here, we show how a deliberate restriction of the tomographic reconstruction to the exterior of the NWs can be used to mitigate these limitations facilitating a quantitative 3D tomographic reconstruction of static electromagnetic stray fields at the nanoscale. As an example, we reconstruct the electrostatic stray field around a GaAs-AlGaAs core shell NW and the magnetic stray field around a Co{sub 2}FeGa Heusler compound NW.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Electronic structure and morphology of epitaxial Bi{sub 2}Te{sub 2}Se topological insulator films

Epitaxial films of the ternary topological insulator Bi{sub 2}Te{sub 2}Se were grown on Si(111) substrates and investigated for their surface electronic properties and morphology. We employ a Se-capping procedure allowing for the preparation of clean films in the surface-analysis experimental setups. Using angle-resolved photoelectron spectroscopy, we determine the dispersion of the topological surface state. With time after surface preparation, the spectroscopic features in the surface electronic structure exhibit significant temperature-dependent shifts to higher binding energies. Scanning tunneling microscopy images show terraces with typical step edge separations of 50 nm–150 nm. X-ray photoelectron spectroscopy indicates an increased Se concentration at the surface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-dimensional electronic spectroscopy with birefringent wedges

We present a simple experimental setup for performing two-dimensional (2D) electronic spectroscopy in the partially collinear pump-probe geometry. The setup uses a sequence of birefringent wedges to create and delay a pair of phase-locked, collinear pump pulses, with extremely high phase stability and reproducibility. Continuous delay scanning is possible without any active stabilization or position tracking, and allows to record rapidly and easily 2D spectra. The setup works over a broad spectral range from the ultraviolet to the near-IR, it is compatible with few-optical-cycle pulses and can be easily reconfigured to two-colour operation. A simple method for scattering suppression is also introduced. As a proof of principle, we present degenerate and two-color 2D spectra of the light-harvesting complex 1 of purple bacteria.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A small-angle x-ray scattering system with a vertical layout

A small-angle x-ray scattering (SAXS) system with a vertical layout (V-SAXS) has been designed and constructed for in situ detection on nanostructures, which is well suitable for in situ study on self-assembly of nanoparticles at liquid interface and polymer processing. A steel-tower frame on a reinforced basement is built as the supporting skeleton for scattering beam path and detector platform, ensuring the system a high working stability and a high operating accuracy. A micro-focus x-ray source combining parabolic three-dimensional multi-layer mirror and scatteringless collimation system provides a highly parallel beam, which allows us to detect the very small angle range. With a sample-to-detector distance of 7 m, the largest measurable length scale is 420 nm in real space. With a large sample zone, it is possible to install different experimental setups such as film stretching machine, which makes the system perfect to follow the microstructures evolution of materials during processing. The capability of the V-SAXS on in situ study is tested with a drying experiment of a free latex droplet, which confirms our initial design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and numerical characterization of a crossover EBIS

For the investigation of highly charged ions, a crossover EBIS (XEBIS) was developed at the University of Frankfurt. In contrast to conventional EBIS/T devices the compression of the electron beam is achieved by electrostatic focusing to a crossover point in the interaction region. This concept allows a compact and simple design. Simulations performed with EGUN show a perveance of 2.1×10{sup −7} A/V{sup 3/2} for the realized gun system. In the interaction region the electron beam has a density of around 10 A/cm{sup 2} and a minimum radius of 0.15 mm. The XEBIS has a total length of 112 mm with a trap length of 26 mm. It is designed for electron beam energies of up to 6 keV/q. The storage capacity of the trap region is in the order of 1×10{sup 8} charges. Charge state breeding studies with CBSIM indicate for the noble gases as maximal achievable charge state Ar{sup 16+}, Kr{sup 30+} and Xe{sup 35+}. Thus ion beam currents of around 2.04 nA assuming 50 Hz repetition rate can be expected. The emittance of the extracted beam is approximated to 8 mm mrad. After completion of the construction phase, the XEBIS will be installed for first performance investigations at a dedicated test bench, equipped with a fast Faraday Cup (FC), a retarding field spectrometer, a luminescence screen and optical diagnostics. Subsequently the XEBIS will serve as source for highly charged ions at different experimental setups.

74 ATOMIC AND MOLECULAR PHYSICS↗

Investigation of a metallic photonic crystal high power microwave mode converter

It is demonstrated that an L band metallic photonic crystal TEM-TE{sub 11} mode converter is suitable for narrow band high power microwave application. The proposed mode converter is realized by partially filling metallic photonic crystals along azimuthal direction in a coaxial transmission line for phase-shifting. A three rows structure is designed and simulated by commercial software CST Microwave Studio. Simulation results show that its conversion efficiency is 99% at the center frequency 1.58 GHz. Over the frequency range of 1.56-1.625 GHz, the conversion efficiency exceeds 90 %, with a corresponding bandwidth of 4.1 %. This mode converter has a gigawatt level power handling capability which is suitable for narrow band high power microwave application. Using magnetically insulated transmission line oscillator(MILO) as a high power microwave source, particle-in-cell simulation is carried out to test the performance of the mode converter. The expected TE{sub 11} mode microwave output is obtained and the MILO works well. Mode conversion performance of the converter is tested by far-field measurement method. And the experimental result confirms the validity of our design. Then, high power microwave experiment is carried out on a Marx-driven Blumlein water line pulsed power accelerator. Microwave frequency, radiated pattern and power are measured in the far-field region and the results agree well with simulation results. The experiment also reveals that no microwave breakdown or pulse shortening took place in the experimental setup.

36 MATERIALS SCIENCE↗

A versatile apparatus for the fine-tuned synthesis of cluster-based materials

In this paper, a custom-designed experimental setup for the fine-tuned synthesis of various cluster–based materials is presented. Providing custom-designed deposition stages and special sample holders it offers a high degree of control over the sample characteristics such as the cluster size, cluster amounts, and sample homogeneity in combination with high sample purity. The system is capable of producing thin films of pure clusters and various cluster-matrix combinations with cluster sizes ranging from single atoms up to aggregates of several thousand atoms. Two custom-designed deposition stages are available, one utilizes the full cluster beam, yielding micrograms of pure clusters within a few hours and the second one uses mass-separated clusters (mass-resolution between 2% and 10%), yielding nanograms of pure clusters in the same timescale. Furthermore, at the second deposition stage, a variety of matrix materials can be co-deposited at a controlled sample temperature between 153 K and 673 K. In order to prove the capabilities of the apparatus, a series of experiments with Fe clusters embedded in Ag matrices with different volume fractions of clusters were carried out. Energy dispersive X-ray spectroscopy measurements revealed that the amount of deposited clusters as well as the sample homogeneity can be controlled with an outstanding accuracy of 10%. Additional measurements of the magnetic properties indicated the presence of separated clusters for volume fractions of clusters around 2 volume percent (vol. %), while above this concentration (10 vol. %) a partial aggregation of the clusters was observed. It was also shown that the resulting thin films are nearly oxygen free, which ascertains that oxygen sensitive materials can be safely handled in this newly developed apparatus.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic particle detection in unshielded environment using orthogonal fluxgate gradiometer

A new detection system for magnetic particles, which can operate in an unshielded environment, is developed using a fundamental mode orthogonal fluxgate gradiometer. The proposed detection system offers the advantages of cost, size, and weight reduction as compared to contamination detection systems using superconducting quantum interference device sensor. The detection system can be used to detect metallic contamination in foods or lithium ion battery production lines. The system has been investigated numerically to optimize various design parameters of the system. Experimental setup has been developed to evaluate some of the numerically predicted results. Steel balls were successfully detected down to the diameter of 50 μm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recent COMPASS results and future prospects for ALICE

The COMPASS Collaboration has accumulated the world’s highest statistics on the reaction π{sup −} p → π{sup +}π{sup −}π{sup −} p at 190 GeV/c. The results, presented in Section 1, show that a new state J{sup PC} = 1{sup ++} state never reported before, the a{sub 1}(1420), decaying to f{sub 0}(980)π followed by f{sub 0}(980) → ππ. In addition, the Collaboration reports an exotic J{sup PC} = 1{sup −+} state, the π{sub 1}(1600), which cannot be a quarkonium. Both states are likely to be a tetra-quark, i.e. qq{sup ¯}+qq{sup ¯} or a gluonic hybrid, a qq{sup ¯} object with an excited gluon inside it. Section 2 is devoted to a brief discussion of the central production of resonances, which is being investigated by both COMPASS and ALICE collaborations. However, the results are not yet released, so it is limited to a broad discussion of the central production, with emphasis on different analyses dictated by differences in the experimental setup.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct current injection and thermocapillary flow for purification of aligned arrays of single-walled carbon nanotubes

Aligned arrays of semiconducting single-walled carbon nanotubes (s-SWNTs) represent ideal configurations for use of this class of material in high performance electronics. Development of means for removing the metallic SWNTs (m-SWNTs) in as-grown arrays represents an essential challenge. Here, we introduce a simple scheme that achieves this type of purification using direct, selective current injection through interdigitated electrodes into the m-SWNTs, to allow their complete removal using processes of thermocapillarity and dry etching. Experiments and numerical simulations establish the fundamental aspects that lead to selectivity in this process, thereby setting design rules for optimization. Single-step purification of arrays that include thousands of SWNTs demonstrates the effectiveness and simplicity of the procedures. The result is a practical route to large-area aligned arrays of purely s-SWNTs with low-cost experimental setups.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A compact and low-weight sputtering unit for in situ investigations of thin film growth at synchrotron radiation beamlines

In this work, we report on a highly variable, compact, and light high-vacuum sputter deposition unit designed for in situ experiments using synchrotron radiation facilities. The chamber can be mounted at various synchrotron beamlines for scattering experiments in grazing incidence geometry. The sample position and the large exit window allow to perform x-ray experiments up to large q values. The sputtering unit is easy to mount on existing experimental setups and can be remote-controlled. In this paper, we describe in detail the design and the performance of the new sputtering chamber and present the installation of the apparatus at different 3rd generation light sources. Furthermore, we describe the different measurement options and present some selected results. The unit has been successfully commissioned and is now available for users at PETRA III at DESY.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical analysis of the background intensity distribution in X-ray Birefringence Imaging using synchrotron bending-magnet radiation

In the recently developed technique of X-ray Birefringence Imaging, molecular orientational order in anisotropic materials is studied by exploiting the birefringence of linearly polarized X-rays with energy close to an absorption edge of an element in the material. In the experimental setup, a vertically deflecting high-resolution double-crystal monochromator is used upstream from the sample to select the appropriate photon energy, and a horizontally deflecting X-ray polarization analyzer, consisting of a perfect single crystal with a Bragg reflection at Bragg angle of approximately 45°, is placed downstream from the sample to measure the resulting rotation of the X-ray polarization. However, if the experiment is performed on a synchrotron bending-magnet beamline, then the elliptical polarization of the X-rays out of the electron orbit plane affects the shape of the output beam. Also, because the monochromator introduces a correlation between vertical position and photon energy to the X-ray beam, the polarization analyzer does not select the entire beam, but instead selects a diagonal stripe, the slope of which depends on the Bragg angles of the monochromator and the polarization analyzer. In the present work, the final background intensity distribution is calculated analytically because the phase space sampling methods normally used in ray traces are too inefficient for this setup. X-ray Birefringence Imaging data measured at the Diamond Light Source beamline B16 agree well with the theory developed here.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The study of frequency-scan photothermal reflectance technique for thermal diffusivity measurement

A frequency scan photothermal reflectance technique to measure thermal diffusivity of bulk samples is studied in this manuscript. Similar to general photothermal reflectance methods, an intensity-modulated heating laser and a constant intensity probe laser are used to determine the surface temperature response under sinusoidal heating. The approach involves fixing the distance between the heating and probe laser spots, recording the phase lag of reflected probe laser intensity with respect to the heating laser frequency modulation, and extracting thermal diffusivity using the phase lag – (frequency) 1/2 relation. The experimental validation is performed on three samples (SiO 2 , CaF 2 and Ge), which have a wide range of thermal diffusivities. The measured thermal diffusivity values agree closely with literature values. Lastly, compared to the commonly used spatial scan method, the experimental setup and operation of the frequency scan method are simplified, and the uncertainty level is equal to or smaller than that of the spatial scan method.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Magnetized retarding field energy analyzer measuring the particle flux and ion energy distribution of both positive and negative ions

This paper presents the development of a magnetized retarding field energy analyzer (MRFEA) used for positive and negative ion analysis. The two-stage analyzer combines a magnetic electron barrier and an electrostatic ion energy barrier allowing both positive and negative ions to be analyzed without the influence of electrons (co-extracted or created downstream). An optimal design of the MRFEA for ion-ion beams has been achieved by a comparative study of three different MRFEA configurations, and from this, scaling laws of an optimal magnetic field strength and topology have been deduced. The optimal design consists of a uniform magnetic field barrier created in a rectangular channel and an electrostatic barrier consisting of a single grid and a collector placed behind the magnetic field. The magnetic barrier alone provides an electron suppression ratio inside the analyzer of up to 6000, while keeping the ion energy resolution below 5 eV. The effective ion transparency combining the magnetic and electrostatic sections of the MRFEA is measured as a function of the ion energy. It is found that the ion transparency of the magnetic barrier increases almost linearly with increasing ion energy in the low-energy range (below 200 eV) and saturates at high ion energies. The ion transparency of the electrostatic section is almost constant and close to the optical transparency of the entrance grid. We show here that the MRFEA can provide both accurate ion flux and ion energy distribution measurements in various experimental setups with ion beams or plasmas run at low pressure and with ion energies above 10 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrument for precision long-term β-decay rate measurements

We describe an experimental setup for making precision measurements of relative β-decay rates of {sup 22}Na, {sup 36}Cl, {sup 54}Mn, {sup 60}Co, {sup 90}Sr, {sup 133}Ba, {sup 137}Cs, {sup 152}Eu, and {sup 154}Eu. The radioactive samples are mounted in two automated sample changers that sequentially position the samples with high spatial precision in front of sets of detectors. The set of detectors for one sample changer consists of four Geiger-Müller (GM) tubes and the other set of detectors consists of two NaI scintillators. The statistical uncertainty in the count rate is few times 0.01% per day for the GM detectors and about 0.01% per hour on the NaI detectors. The sample changers, detectors, and associated electronics are housed in a sealed chamber held at constant absolute pressure, humidity, and temperature to isolate the experiment from environmental variations. The apparatus is designed to accumulate statistics over many years in a regulated environment to test recent claims of small annual variations in the decay rates. We demonstrate that absent this environmental regulation, uncontrolled natural atmospheric pressure variations at our location would imprint an annual signal of 0.1% on the Geiger-Müller count rate. However, neither natural pressure variations nor plausible indoor room temperature variations cause a discernible influence on our NaI scintillator detector count rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental analysis of energy harvesting from self-induced flutter of a composite beam

Previous attempts to harvest energy from aeroelastic vibrations have been based on attaching a beam to a moving wing or structure. Here, we exploit self-excited oscillations of a fluttering composite beam to harvest energy using piezoelectric transduction. Details of the beam properties and experimental setup are presented. The effects of preset angle of attack, wind speed, and load resistance on the levels of harvested power are determined. The results point to a complex relation between the aerodynamic loading and its impact on the static deflection and amplitudes of the limit cycle oscillations on one hand and the load resistance and level of power harvested on the other hand.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗