Search NASA⌕ Search

SEARCH · Search NASA

Results for “flooring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Initial Simulations of Empty Room Collapse and Reconsolidation at the Waste Isolation Pilot Plant

The Waste Isolation Pilot Plant (WIPP) is a geologic repository for defense-related nuclear waste. If left undisturbed, the virtually impermeable rock salt surrounding the repository will isolate the nuclear waste from the biosphere. If humans accidentally intrude into the repository in the future, then the likelihood of a radionuclide release to the biosphere will depend significantly on the porosity and permeability of the repository itself. Room ceilings and walls at the WIPP tend to collapse over time, causing rubble piles to form on floors of empty rooms. The surrounding rock formation will gradually compact these rubble piles until they eventually become solid salt, but the length of time for a rubble pile to reach a certain porosity and permeability is unknown. This report details the first efforts to build models to predict the porosity and permeability evolution of an empty room as it closes. Conventional geomechanical numerical methods would struggle to model empty room collapse and rubble pile consolidation, so three different meshless methods, the Immersed Isogeometric Analysis Meshfree, Reproducing Kernel Particle Method (RKPM), and the Conformal Reproducing Kernel method, were assessed. First, the meshless methods and the finite element method each simulated gradual room closure, without ceiling or wall collapse. All three methods produced equivalent room closure predictions with comparable computational speed. Second, the Immersed Isogeometric Analysis Meshfree method and RKPM simulated two-dimensional empty room collapse and rubble pile consolidation. Both methods successfully simulated large viscoplastic deformations, fracture, and rubble pile rearrangement to produce qualitatively realistic results. In addition to geomechanical simulations, the flow channels in damaged salt and crushed salt were measured using micro-computed tomography, and input into a computational fluid dynamics simulation to predict the salt's permeability. Although room for improvement exists, the current simulation approaches appear promising.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Treatment of Tilted Sonar Data for Salt Cavern Analysis

Structural modeling and visualization of salt caverns requires three-dimensional representations. These representations are typically produced from sonar surveys conducted by companies that then produce a report of depths, distances, and volumes. There are multiple formats that are vendor dependent, and, as technology improves, there have been changes from only horizontal surveys to inclined shots for ceilings and floors to mid-cavern inclined shots. For geomechanical modeling, leaching predictions, and cavern stability visualizations, Sandia has previously written in-house software, called SONAR8, that created a consistent geometry format from the processed sonar reports. However, the increase in the need for mid-cavern inclined surveys led to the discovery of certain limitations in that code. This report describes methods used to process the multiple different formats to handle inclined shots in a consistent and accurate manner in our modeling efforts. A set of file formats and a database schema that was developed for this work is also documented in the appendices.

02 PETROLEUM↗

ENERGY STAR for Tenants: An Online Energy Estimation Tool for Commercial Office Building Tenants

The commercial building sector consumes over 18% of the total energy in the United States. According to the 2012 Commercial Building Energy Consumption Survey (CBECS), office buildings comprise nearly 16 billion square feet of floor space and consume 253 billion kWh of energy annually. Office buildings represent nearly one-fifth of the energy consumed by commercial buildings, more than any other building type. Therefore, monitoring and reducing energy consumption in office buildings has become an increasingly important focus across the United States. The goal of the ENERGY STAR for Tenants program is to recognize office building tenants who demonstrate commitment to energy efficiency and environmental stewardship. Tenants seeking recognition must complete five major steps: estimate energy use, meter energy use, use efficient lighting, use efficient equipment, and share data. NREL is responsible for the underlying analysis performed for step one, estimating energy use. An online survey was developed for tenants to input information about their office space and its internal loads. NREL performed a parametric analysis across a large parameter space of office buildings. The analysis results were processed to map the user inputs to output energy ranges. The mappings enable the web tool to provide users with instant energy usage estimates based on a limited number of inputs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulating Buildings While the Design is Still in the Architect's Imagination

Very early in the design process, prior to drawing a single line, architects get information from their client or prospective client trying to understand the nature and requirements of the building that needs to be designed. The design of the building is completely fluid, as the architect considers many options in their imagination. The overall massing of the building, the general shape and form, are being considered during this early step. Even for a simple box-shaped building, the aspect ratio between the east-west and the north-south dimensions of the building can greatly impact energy consumption due to daylighting availability. The prevailing winds and building orientation can impact natural ventilation. The locations of high and low population density spaces can also impact energy use. Deciding the floor area per office workstation or the size of the auditorium will impact energy use. Does making a building two stories instead of one reduce energy impacts by reducing roof area or does the additional volume for stairs and elevators result in more energy use. Since certain types of spaces require more windows for occupants than others, the locations of those spaces will determine how much glazing each building orientation has impacting daylighting as well as heating and cooling energy. The project was an attempted first step toward creating a system tailored toward architects for this very early stage in the design process to help them understand the energy impacts of design options. The approach was not to be based on drawing the building, and instead, the main inputs would have been the size of each type of space in the building. This report describes information gathered during the development that might be of use to others developing similar software as well as some of the software that was developed during the project. Phase II funding to continue this work was not pursued due to intellectual property issues discovered during the development of the commercialization plan.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart Vacuum Cleaner Concept of Operations [Slides]

Modern living brings with it the need to use time as efficiently as possible, one of the key objectives being to create as much free-time for ourselves as we possibly can. In an ideal world, the domestic appliances of today would be replaced by new gadgets with the ability to perform tasks in a completely independent way. This document presents the application of Systems Engineering tools for the concept of operations for a smart vacuum cleaner, a device that replaces the use of hand-held vacuums, and provides a completely automated remote-operated option for keeping floors of all types clean.

42 ENGINEERING↗

Research Needs for Uranium-Zirconium- Based Metallic Fuels

The purpose of this report is to summarize the needs and present recommendations related to the future direction for U-Zr-based metallic fuel research (including binary U-Zr and ternary U-Pu-Zr alloys). These needs and recommendations were determined by subject matter experts from various institutions during a two-day workshop held at the University of Florida in November, 2019. During open-floor discussions, the highest priority gaps in our understanding of U-Zr-based fuels were down-selected, and near- and long-term needs that directly impact the implementation of these metallic fuels were identified. The identified near-term needs include investigation of the following phenomena: i) swelling and fission gas release, ii) fuel-cladding chemical interaction, iii) phase evolution/constituent redistribution, and iv) thermal properties of the fuels. The long-term needs are: i) investigation of fuel creep and plasticity and ii) fission product (lanthanide) transport. In addition, there was general agreement that all institutions and subject matter experts would benefit from an open-source metallic fuels database with thermophysical property and microstructural data, along with fuel operation/irradiation history, which should be regularly updated with vetted information from new experimental and computational investigations and used to advance metallic fuels research and development. Finally, we recommend that metallic fuel research should be ongoing and that fuel qualification and fuel optimization should be equally prioritized; research combining experiments with modeling and simulation has the largest potential impact.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Low-frequency Electromagnetic Detection Limits of Underground Nuclear Explosions

Underground nuclear explosions produce a broadband electromagnetic signal that can propagate to the surface at some distance. We perform a logistic regression on historical electromagnetic detections to calculate a probabilistic detection curve for prediction of the propagation distance for any given underground nuclear explosion. The curve predicts positive detections at scaled ranges of 2414.6, 2025.7, 1908.3, and 1672.4 m/ktonne 1/3 at probabilities of 50, 90, 95 and 99%, respectively. For a theoretical 100 ktonne underground nuclear explosion these scaled ranges translate to absolute ranges of 11.2, 9.4, 8.9, and 7.8 km at probabilities of 50, 90, 95 and 99%, respectively. We also motivate a need for improved electromagnetic sensor design and deployment by extending the detection analysis using the quoted signal-to-noise ratio of two and noise amplitude of 10 pT along with attenuation relationships that go as 1/r to 1/r 3 . We find that reducing the noise floor by a factor often could extend the detection limit to approximately 5 to 25 km/ktonne 1/3 , which translates to 24 to 112 km for a theoretical 100 ktonne underground nuclear explosion.

58 GEOSCIENCES↗

Review of "ML for Surface Complexation Model Development"

The presentation given by Jadallah Zouabe on “ML for Surface Complexation Model Development”was extremely informative, but lacked some explanation of details that made the latter half hard to follow as someone outside of the field. He began his presentation with an anecdote to spilling milk or ink on the floor and seeing it spread, cleverly connecting that to the spread of contamination in the real world. He then explained the importance of being able to model contamination, as it allows specialists to see the potential effects on different areas and environments in the coming years. Heal so made it clear that the main issue trying to be addressed here is how expensive modelling is and that their goal is to make computationally cheaper models. The introduction was overall very well formulated and attention-grabbing, but it seemed to take up too much of the presentation time, as after this point the presentation lacked details and explanations.

54 ENVIRONMENTAL SCIENCES↗

Radial Deconsolidation and Leach-Burn-Leach of AGR-3/4 Compact 1-4 and 10-4

The Advanced Gas Reactor (AGR) Fuel Development and Qualification Program third and fourth irradiation experiments (AGR-3/4), originally planned as separate tests, were combined in one test train for irradiation in the Advanced Test Reactor at Idaho National Laboratory (INL). The irradiation test began on December 14, 2011 and ended on April 12, 2014 (Collin 2016). The originally planned AGR-3 and AGR-4 irradiation experiments were both focused on obtaining data on fission product transport to support the improvement of modeling. The AGR-3 experimental plan was focused on gaseous and metallic fission product release from the kernels and diffusion in the coatings during irradiation and postirradiation safety testing. The AGR-4 experimental plan was focused on diffusivities and sorptivities in the compact matrix and reactor graphite (Petti et al. 2005). These two goals were combined in the AGR-3/4 irradiation, which consisted of twelve independently monitored capsules that each contained four AGR-3/4 compacts in a single stack surrounded by an inner ring of matrix or graphite and an outer ring of graphite. There were two capsule types: a standard capsule and a “fuel body”, in which the outer graphite ring included a floor and cap that fully enclosed the fuel (Stempien et al. 2018a). The fuel body design supported post-irradiation safety testing of the intact fuel and ring assembly to provide data on fission product transport and release from matrix and graphite at accident temperatures (Demkowicz 2017).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Blue Room timeline update

The following files are an update to the unclassified timeline in the Blue Room (the classified Weapons museum on the sixth floor of the NSSB). The current timeline ends at 2011; these files will bring the timeline up to the present. The previous timeline also failed to show that the USSR became Russia in 1991, so these files update that major world event. The timeline will be viewed by VIP visitors to the Laboratory

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Installation of Ramps and Utility Cabinet at TA-18-1 Slotin Building (Historic Building Report No. 395)

The information below is presented in response to requests for additional information that resulted from a phone conference on November 12, 2020 between Harvey Kaplan of the New Mexico State Historic Preservation Office, DOE NNSA Los Alamos Field Office Manhattan Project National Historical Park Representative, Vicki Loucks, LANL Program Manager for Manhattan Project National Historical Park, Cheryl Abeyta, and LANL Historic Buildings Program Staff, Jeremy Brunette and J.T. Stark. The DOE NNSA Field Office (Field Office) initiated the call to propose additional work be performed to a previously reviewed project, “Restoration of TA-18-0001 (Slotin Building)” (LA-UR-19-26609) (HPD Log # 111110). Of the six actions discussed on the call, which included (1) exterior paint color, (2) entrance ramps, (3) non-period metal siding removal, (4) interior floor finish, (5) reopening secondary entrance door, and (6) addition of utility cabinet with period doors, additional information for two of the actions was requested for further review. The two actions, the construction of entrance ramps and installation of a utility cabinet are addressed in detail.

42 ENGINEERING↗

Room Return Path Sensitivity

Standard practice for HVAC return design has evolved from running a dedicated return to each room with a supply, to systems with returns in more centrally located areas of the home with jump ducts, transfer grilles, or simply door undercuts used as return air pathways from isolated rooms. In these latter systems, hallways and stairwells act as large open ducts for conveying air back to a single (or sometimes multiple) central return. When partition doors to an isolated room are closed, the return airflow resistance goes up, significantly impacting airflow balance if an adequate relief pathway is not installed. Airflow imbalances can lead to comfort and building durability issues and increased envelope leakage. To combat this, some jurisdictions have requirements for return air pathways. The supply system topology–or layout–impacts the airflow balance stability in response to adjustments of return pathway resistances. Branching supply topologies typically have reduced static pressure after each split. The static pressure at the final split will be lower than the primary supply plenum. Because of this, if there is a restriction in a room’s return path, supply airflow will tend to redistribute to adjacent ducts at the end of the branch. A properly designed trunk and branch supply system can effectively equalize static pressure by reducing the cross sectional area after each takeoff . Maintaining static pressure within the trunk will reduce the system’s sensitivity to changes in return paths. However, in practice, it is difficult to design and time consuming to install a complex supply plenum. Velocity effects and poor takeoff placement also impact airflow balance. This report considers return systems in three main categories: distributed, with a return duct to each room; multiple central, with one return grille on each floor of a home; and single central, with a single return grille located near the air handling unit. Three supply categories are also considered: radial splitter box, trunk and branch, and home-run with all ducts connecting directly to a central manifold.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploring Gamma-Ray and Neutron Spectroscopy Missions to Mars Caves [Slides]

In this work, we investigate the sensitivity of active neutron detector systems in Mars caves using MCNP6 to model neutron transport in different cave geometries, compositions, and detectors to determine if active neutron measurements can be used to identify the hydration of cave walls vs floor vs ceilings, and to perform a concept study for potential future Mars cave missions in search of hydration and habitable regions.

79 ASTRONOMY AND ASTROPHYSICS↗

Radial Deconsolidation and Leach-Burn-Leach of AGR-3/4 Compacts 8-4 and 7-4

The Advanced Gas Reactor (AGR) Fuel Development and Qualification Program’s third and fourth irradiation experiments (AGR-3/4), originally planned as separate tests, were combined into one test train for irradiation in the Advanced Test Reactor at Idaho National Laboratory (INL). The irradiation test began on December 14, 2011, and ended on April 12, 2014 (Collin 2016). The originally planned AGR-3 and AGR-4 irradiation experiments were both to be focused on obtaining fission product transport data to support improvements in modeling. The AGR-3 experimental plan was focused on gaseous and metallic fission product release from the kernels and diffusion in the coatings during irradiation and postirradiation safety testing. The AGR-4 experimental plan was focused on diffusivities and sorptivities in the compact matrix and reactor graphite (Petti et al. 2005). These goals were combined in the AGR-3/4 irradiation experiment, which consisted of twelve independently monitored capsules that each contained four AGR-3/4 compacts in a single stack surrounded by an inner ring of matrix or graphite and an outer ring of graphite. There were two capsule types: a standard capsule and a fuel body, in which the outer graphite ring included a floor and cap to fully enclose the fuel (Stempien et al. 2018a). The fuel body design supported post-irradiation safety testing of the intact fuel and ring assembly to obtain data on fission product transport and release from matrix and graphite at accident temperatures (Demkowicz 2017).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

National Cost-Effectiveness of ANSI/ASHRAE/IES Standard 90.1–2019

The purpose of this analysis is to examine the cost-effectiveness of the 2019 edition of ANSI/ASHRAE/IES Standard 90.1, which is developed by the ASHRAE Standard Standing Project Committee (SSPC) 90.1, and is the model energy standard for all commercial buildings and multifamily residential buildings over three floors. PNNL analyzed the cost-effectiveness of changes in Standard 90.1-2019, compared to the previous 90.1-2016 edition, as applied in commercial buildings across the United States. In reviewing proposed changes to Standard 90.1, the SSPC considers the cost-effectiveness of individual changes (addenda). Due to the continuous nature of the development process, however, ASHRAE does not evaluate the entire package of addenda from one edition of the standard to the next, which is of particular interest to adopting state and local governments. Providing states with an analysis of cost-effectiveness facilitates a more comprehensive understanding of the impacts associated with updated model energy codes, informs the state decision-making process and its authorities, and ultimately encourages greater adoption of updated of energy codes. This information also informs the development of future editions of Standard 90.1.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Tritium Behavior in Forest Vegetation for the Purpose of Determining Appropriate Non-Zero Deposition Velocities for Tritium Oxide

Modeling and field measurements have been conducted between 2019 and 2021 to assess the practicality of using a non-zero deposition velocity for safety basis estimates of tritium oxide fate and transport modeling. A model was developed which used a complex deposition algorithm designed to assess how tritium oxide would mix based on the turbulent motions and wind speed effects that the forest canopy has on the atmosphere. The model was driven based on measurements of wind and turbulence taken from the Aiken AmeriFlux Tower which measures these properties at five levels located within and just above the forest. The model was then validated against a series of field experiments which were designed to test the model predictions and estimate the deposition velocity occurring over the forest environment at the Savannah River Site. The field releases used deuterium oxide as a surrogate for tritium oxide and was released as a fine mist which rapidly evaporated, creating a gaseous tracer in the atmosphere. Using air samplers, the elevations in deuterium concentration in the air relative to background measurements was assessed and then modeled. Generally, the numerical model tended to underpredict the amount of deuterium being mixed from above the canopy to the forest floor, indicating that the predictions it provides are still conservative relative to what was measured during the field experiments. Across a suite of modeling runs, the 95 th and 99 th percentile deposition velocities were estimated to be 1.2 and 0.7 cm s -1 , respectively. Estimated deposition velocities in the 2021 field experiments, which specifically assessed a release above the forest canopy and its mixing to the surface, predicted deposition velocities ranging from 1.75 to 6.61 cm s -1 . While these field releases do not cover all possible meteorological conditions, it seems appropriate to use a non-zero deposition velocity when performing safety-basis modeling of tritium oxide. The recommendation presented in this report is to use 1.0 cm s -1 . This is between the 95 th and 99 th percentile value estimated from the modeling study, suggesting it should be appropriate for the majority of release scenarios given the model’s apparent conservatism relative to field measurements.

54 ENVIRONMENTAL SCIENCES↗

Photographic Mitigation Documentation Related to the Engine Assembly and Disassembly Facility, Area 25, Nevada National Security Site, Nye County, Nevada

This letter report provides documentation in partial fulfillment of the mitigation of adverse effects to the Engine Maintenance Assembly and Disassembly (E-MAD) facility, a major component of the Nuclear Rocket Development Station (NRDS) Historic District located in Area 25 of the Nevada National Security Site (NNSS). Construction of the E-MAD facility began in 1962 for the purpose of disassembling and maintaining nuclear-powered rocket engines. Once the building was complete in 1967, the E-MAD facility remained in continuous operation until the nuclear rocket program was terminated in 1973. The mothballed facility was repurposed in 1977 for spent nuclear fuel handling and packaging activities. By the mid-1980s, all activities at the E-MAD facility had ceased (Reno et al. 2019). This submission is intended to comply with Stipulation III.D.1 of the Memorandum of Agreement DE-GM58-20NA25534 between the U.S. Department of Energy and the Nevada State Historic Preservation Officer Regarding Corrective Action Activities and Demolition of the Engine Maintenance Assembly and Disassembly Facility and the Test Cell C Historic District, Major Components of the Nuclear Rocket Development Station Historic District Located in Area 25 at the Nevada National Security Site Nye County (hereafter referred to as the MOA). Stipulation III.D.1 states the U.S. Department of Energy (DOE) will submit the existing supplementary collection of the large-format, black-and-white photographic prints taken during the 1996 Historic American Engineering Record (HAER) documentation of the E-MAD facility to the Nuclear Testing Archive (NTA), located on the second floor of the Rogers Building at Desert Research Institute (DRI) in Las Vegas, Nevada.

54 ENVIRONMENTAL SCIENCES↗