Search NASA⌕ Search

SEARCH · Search NASA

Results for “flow improvers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Improvement on the plasma performances via application of flowing lithium limiters in EAST tokamak

Three generation of flowing liquid lithium (FLiLi) limiters have been developed and successfully tested in EAST since 2014. It was confirmed that liquid Li could be driven by an innovative in-vessel DC electromagnetic J × B pump to form a recirculating loop. The FLiLi design was continuously upgraded, resulting in improvement of the liquid Li surface coverage (>80%), elimination of surface erosion, and the increase of heat exhaust capability. Promising results are obtained during FLiLi operations, including a reduction of impurities and recycling to improve plasma confinement, and a mitigation of ELM activity in H-mode plasmas. The FLiLi limiter program has shown basic compatibility with H-mode discharges with auxiliary heating power up to 8.3 MW. These efforts will expand to flowing liquid Li PFC in high heat flux zones, e.g. near the divertor strike point in reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CFD Simulations of Landing and Takeoff CRM High-Lift Configurations

Numerical simulations have been performed for a conventional high-lift version of the Common Research Model (CRM) model corresponding to landing and take- off configurations. Computed values of lift and drag for the landing configuration are compared with the experimental data acquired in the 14- by 22-Foot Subsonic Tunnel (14×22) at the NASA Langley Research Center (LaRC). Simulations replicated the experimentally observed improvements in the lift characteristics in the presence of a nacelle chine. Flow visualization images indicate that vortices generated by the nacelle chine reduce flow separation regions on the upper surface of the wing at higher angles of attack. Based on such observations, the take-off configuration considered is also equipped with a nacelle chine, and testing of this configuration is planned in the 14×22 tunnel in near future. Preliminary solutions are also presented to explore the feasibility of using a localized flap gap blowing (LFGB) active flow control concept for improving the aerodynamic performance at take-off conditions.

aerodynamics↗

CFD Simulations of Landing and Takeoff CRM High-Lift Configurations

Numerical simulations have been performed for a conventional high-lift version of the Common Research Model (CRM) model corresponding to landing and take- off configurations. Computed values of lift and drag for the landing configuration are compared with the experimental data acquired in the 14- by 22-Foot Subsonic Tunnel (14×22) at the NASA Langley Research Center (LaRC). Simulations replicated the experimentally observed improvements in the lift characteristics in the presence of a nacelle chine. Flow visualization images indicate that vortices generated by the nacelle chine reduce flow separation regions on the upper surface of the wing at higher angles of attack. Based on such observations, the take-off configuration considered is also equipped with a nacelle chine, and testing of this configuration is planned in the 14×22 tunnel in near future. Preliminary solutions are also presented to explore the feasibility of using a localized flap gap blowing (LFGB) active flow control concept for improving the aerodynamic performance at take-off conditions.

aerodynamics↗

Fish Passage though Hydropower Turbines: Simulating Blade Strike using the Discrete Element Method

mong the hazardous hydraulic conditions affecting anadromous and resident fish during their passage though turbine flows, two are believed to cause considerable injury and mortality: collision on moving blades and decompression. Several methods are currently available to evaluate these stressors in installed turbines, i.e. using live fish or autonomous sensor devices, and in reduced-scale physical models, i.e. registering collisions from plastic beads. However, a priori estimates with computational modeling approaches applied early in the process of turbine design can facilitate the development of fish-friendly turbines. In the present study, we evaluated the frequency of blade strike and nadir pressure environment by modeling potential fish trajectories with the Discrete Element Method (DEM) applied to fish-like composite particles. In the DEM approach, particles are subjected to realistic hydraulic conditions simulated with computational fluid dynamics (CFD), and particle-structure interactions—representing fish collisions with turbine blades—are explicitly recorded and accounted for in the calculation of particle trajectories. We conducted transient CFD simulations by setting the runner in motion and allowing for better turbulence resolution, a modeling improvement over the conventional practice of simulating the system in steady state which was also done here. While both schemes yielded comparable bulk hydraulic performance, transient conditions exhibited a visual improvement in describing flow variability. We released streamtraces (steady flow solution) and DEM particles (transient solution) at the same location from where sensor fish (SF) have been released in field studies of the modeled turbine unit. The streamtrace-based results showed a better agreement with SF data than the DEM-based nadir pressures did because the former accounted for the turbulent dispersion at the intake but the latter did not. However, the DEM-based strike frequency is more representative of blade-strike probability than the steady solution is, mainly because DEM particles accounted for the full fish length, thus resolving (instead of modeling) the collision event.

CFD↗

Simulation of Helium Flow Visualization Apparatus for Studies of Blanket Cooling in Fusion Reactors

Flow visualization is essential to understanding helium cooling performance. This article investigates helium flow visualization in an apparatus to support the design of the blanket first wall for a fusion reactor. Helium’s safety advantages make it an attractive coolant, but effective cooling and flow visualization remain challenging. Sophisticated simulations are conducted in different test sections to address three key areas in the design of a test apparatus and cooling channel enhancements: the influence of viewing glass windows on flow patterns, the impact of increased heating, and the effectiveness of cooling structures like baffles. Viewing glass windows introduce flow recirculation region bifurcation and flow asymmetry, affecting flow patterns and necessitating careful analysis in future experiments. Increased heating results in helium flow detachment from the heated surface, leading to hot spots. Cooling structures, particularly baffles, prove effective in maintaining consistent attachment to the heated surface, improving the heat transfer performance. Further, this study also examines a tunable parameter in the turbulence model, highlighting the importance of accurate model tuning for future fusion reactor cooling designs. With an imminent helium flow visualization facility, these simulations will be used to optimize cooling structures on the heated wall to improve flow attachment and heat transfer efficiency. This work serves as a first investigation of the helium flow visualization apparatus for blanket cooling enhancement in fusion reactor design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Unilateral Versus Bilateral Prostatic Arterial Embolization for Lower Urinary Tract Symptoms in Patients with Prostate Enlargement

This study was designed to compare baseline data and clinical outcome between patients with prostate enlargement/benign prostatic hyperplasia (PE/BPH) who underwent unilateral and bilateral prostatic arterial embolization (PAE) for the relief of lower urinary tract symptoms (LUTS). This single-center, ambispective cohort study compared 122 consecutive patients (mean age 66.7 years) with unilateral versus bilateral PAE from March 2009 to December 2011. Selective PAE was performed with 100- and 200-{mu}m nonspherical polyvinyl alcohol (PVA) particles by a unilateral femoral approach. Bilateral PAE was performed in 103 (84.4 %) patients (group A). The remaining 19 (15.6 %) patients underwent unilateral PAE (group B). Mean follow-up time was 6.7 months in group A and 7.3 months in group B. Mean prostate volume, PSA, International prostate symptom score/quality of life (IPSS/QoL) and post-void residual volume (PVR) reduction, and peak flow rate (Qmax) improvement were 19.4 mL, 1.68 ng/mL, 11.8/2.0 points, 32.9 mL, and 3.9 mL/s in group A and 11.5 mL, 1.98 ng/mL, 8.9/1.4 points, 53.8 mL, and 4.58 mL/s in group B. Poor clinical outcome was observed in 24.3 % of patients from group A and 47.4 % from group B (p = 0.04). PAE is a safe and effective technique that can induce 48 % improvement in the IPSS score and a prostate volume reduction of 19 %, with good clinical outcome in up to 75 % of treated patients. Bilateral PAE seems to lead to better clinical results; however, up to 50 % of patients after unilateral PAE may have a good clinical outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nutrition, risk factors, prevention, and imaging: The 2018 Mario Verani Lecture

Heart disease has been the leading cause of death in the United States since 1918. Cardiac mortality rates have dramatically decreased in this era of advanced medical and interventional therapies. However, this has been aptly described as “mopping up the floor instead of turning off the faucet.” With this recognition, prevention in cardiology is poised to become a central focus. Within prevention, dietary intervention is recognized as the single largest opportunity for improved cardiovascular outcomes, including improvement or elimination of cardiac risk factors, prevention of myocardial infarction, stroke and cardiovascular death, and reduction of plaque burden and myocardial ischemia. Cardiac imaging, particularly nuclear perfusion and coronary computed tomographic angiography, plays a critical role in early diagnosis and serial evaluation of myocardial ischemia and coronary artery disease. These techniques have the potential to help refine research protocols and evaluate their success by providing intermediate markers of improved myocardial blood flow and coronary plaque morphology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An adjoint view on flux consistency and strong wall boundary conditions to the Navier–Stokes equations

Inconsistent discrete expressions in the boundary treatment of Navier–Stokes solvers and in the definition of force objective functionals can lead to discrete-adjoint boundary treatments that are not a valid representation of the boundary conditions to the corresponding adjoint partial differential equations. The underlying problem is studied for an elementary 1D advection–diffusion problem first using a node-centred finite-volume discretisation. The defect of the boundary operators in the inconsistently defined discrete-adjoint problem leads to oscillations and becomes evident with the additional insight of the continuous-adjoint approach. A homogenisation of the discretisations for the primal boundary treatment and the force objective functional yields second-order functional accuracy and eliminates the defect in the discrete-adjoint boundary treatment. Subsequently, the issue is studied for aerodynamic Reynolds-averaged Navier–Stokes problems in conjunction with a standard finite-volume discretisation on median-dual grids and a strong implementation of noslip walls, found in many unstructured general-purpose flow solvers. Going out from a base-line discretisation of force objective functionals which is independent of the boundary treatment in the flow solver, two improved flux-consistent schemes are presented; based on either body wall-defined or farfield-defined control-volumes they resolve the dual inconsistency. The behaviour of the schemes is investigated on a sequence of grids in 2D and 3D.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A framework and calculator for evaluating the impacts of shelf life extension and other food loss and waste reduction technologies

Optimization of the food supply chain (FSC) depends on reducing food waste, especially at the consumer stage, where a substantial portion of food is not eaten, but instead disposed of via landfill, incineration, or in-sink disposals. One key strategy is to increase the time that consumers have before food goes bad or expires. This study developed a framework to assess the efficacy of shelf-life extension (SLE) technologies for mitigating food loss and waste (FLW), such as packaging improvements. The impact flows through the entire FSC, reducing FLW, energy use, and other inputs at each stage. The framework and resulting calculator can be used to evaluate the impact of FLW reduction at any stage for any food commodity. As shown by two SLE cases, the calculator is valuable for policy-makers, government entities, and professionals, specifically those in marketing, business development, and capital projects teams, to comprehensively evaluate the impacts of FLW reduction technologies and practices. The framework and calculator are sensitive to the shape of the consumption curve, the fraction of inedible waste, and the current shelf life. The calculator was used to assess the impacts of the United States goal of reducing food waste by consumers through various SLE lengths. It was found that uptake of several near-ready-to-deploy SLE technologies would reduce annual food production demand by about 10–19 MMT and supply chain energy consumption by 240–410 PJ in the United States.

Food loss and waste (FLW)↗

MBM fuel feeding system design and evaluation for FBG pilot plant

Highlights: Black-Right-Pointing-Pointer A 1-5 g/s fuel feeding system for pilot scale FBG was designed, built and tested. Black-Right-Pointing-Pointer Multiple conveying stages improve pressure balancing, flow control and stability. Black-Right-Pointing-Pointer Secondary conveyor stage reduced output irregularity from 47% to 15%. Black-Right-Pointing-Pointer Pneumatic air sparging effective in dealing with poor flow ability of MBM powder. Black-Right-Pointing-Pointer Pneumatic injection port plugs with char at gasification temperature of 850 Degree-Sign C. - Abstract: A biomass fuel feeding system has been designed, constructed and evaluated for a fluidized bed gasifier (FBG) pilot plant at the University of Saskatchewan (Saskatoon, SK, Canada). The system was designed for meat and bone meal (MBM) to be injected into the gasifier at a mass flow-rate range of 1-5 g/s. The designed system consists of two stages of screw conveyors, including a metering stage which controlled the flow-rate of fuel, a rotary airlock and an injection conveyor stage, which delivered that fuel at a consistent rate to the FBG. The rotary airlock which was placed between these conveyors, proved unable to maintain a pressure seal, thus the entire conveying system was sealed and pressurized. A pneumatic injection nozzle was also fabricated, tested and fitted to the end of the injection conveyor for direct injection and dispersal into the fluidized bed. The 150 mm metering screw conveyor was shown to effectively control the mass output rate of the system, across a fuel output range of 1-25 g/s, while the addition of the 50 mm injection screw conveyor reduced the irregularity (error) of the system output rate from 47% to 15%. Although material plugging was found to be an issue in the inlet hopper to the injection conveyor, the addition of air sparging ports and a system to pulse air into those ports was found to successfully eliminate this issue. The addition of the pneumatic injection nozzle reduced the output irregularity further to 13%, with an air supply of 50 slpm as the minimum air supply to drive this injector. After commissioning of this final system to the FBG reactor, the injection nozzle was found to plug with char however, and was subsequently removed from the system. Final operation of the reactor continues satisfactorily with the two screw conveyors operating at matching pressure with the fluidized bed, with the output rate of the system estimated based on system characteristic equations, and confirmed by static weight measurements made before and after testing. The error rate by this method is reported to be approximately 10%, which is slightly better than the estimated error rate of 15% for the conveyor system. The reliability of this measurement prediction method relies upon the relative consistency of the physical properties of MBM with respect to its bulk density and feeding characteristics.

09 BIOMASS FUELS↗

Formulation and Performance Evaluation of Epoxy Sealant Systems for Double-Shell Tank Bottom Refurbishment

The performance of epoxy sealants used in the refurbishment of double-shell tank (DST) systems requires balancing processability, thermomechanical stability, and adhesion to cementitious substrates. This study incorporates Heloxy 8 as a reactive diluent into Westlake 862 epoxy to tailor workability and cured-state properties. Rheological time-sweep analysis demonstrates that increasing the diluent content significantly reduces complex viscosity and extends workability, thereby improving pumpability and flow for large-area applications. However, the targeted 2-hour processing window is not fully achieved. Differential scanning calorimetry (DSC) confirms that all formulations cure at room temperature to glass transition temperatures ( T g ) at least 20 °C above the maximum DST operating temperature (27 °C), thereby ensuring service in the glassy regime. Dynamic mechanical analysis (DMA) reveals formulation-dependent reductions in tan delta and increases in storage modulus, indicating increasingly elastic and mechanically stable networks with diluent incorporation. Pull-off adhesion testing shows that modified formulations (70–90% Westlake epoxy) exhibit significantly higher adhesion strengths than the unmodified system. Grout cohesive failure indicates that interfacial bonding exceeds substrate strength. Collectively, these results demonstrate that controlled reactive diluent incorporation enables optimization of processing behavior, interfacial adhesion, and thermomechanical performance, supporting the suitability of the modified epoxy systems as durable sealant layers for cementitious barrier applications in hazardous waste containment infrastructure.

Differential scanning calorimetry↗

High Frequency Monitoring and Nitrate Sourcing Reveals Baseflow and Stormflow Controls on Total Dissolved Nitrogen and Carbon Export Along a Rural‐Urban Gradient

Abstract Efforts to reduce nitrogen and carbon loading from developed watersheds typically target specific flows or sources, but across gradients in development intensity there is no consensus on the contribution of different flows to total loading or sources of nitrogen export. This information is vital to optimize management strategies leveraging source reductions, stormwater controls, and restorations. We investigate how solute loading and sources vary across flows and land‐use using high frequency monitoring and stable nitrate isotope analysis from five catchments with different sanitary infrastructure, along a gradient in development intensity. High frequency monitoring allowed estimation of annual loading and attribution to storm versus baseflows. Nitrate loads were 16 kg/km 2 /yr. from the forested catchment and ranged from 68 to 119 kg/km 2 /yr., across developed catchments, highest for the septic served site. Across developed catchments, baseflow contributions ranged from 40% of N loading to 75% from the septic served catchment, and the contribution from high stormflows increased with development intensity. Stormflows mobilized and mixed many surface and subsurface nitrate sources while baseflow nitrate was dominated by fewer sources which varied by catchment (soil, wastewater, or fertilizer). To help inform future sampling designs, we demonstrate that grab sampling and targeted storm sampling would likely fail to accurately predict annual loadings within the study period. The dominant baseflow loads and subsurface stormflows are not treated by surface water management practices primarily targeted to surface stormflows. Using a balance of green and gray infrastructure and stream/riparian restoration may target specific flow paths and improve management.

Delesantro, Joseph M.↗

Development of a YAG laser system for the edge Thomson scattering system in ITER

A prototype YAG laser system for the edge Thomson scattering system in ITER has been newly developed. Performance of the laser amplifier was improved by using flow tubes made of samarium-doped glass; the small signal gain reached 20 at its maximum. As a result, an output energy of 7.66 J at 100 Hz was successfully achieved, and the performance exceeded the target performance (5 J, 100 Hz).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Asymptotically safe non-minimal inflation

We study the constraints imposed by the requirement of Asymptotic Safety on a class of inflationary models with an inflaton field non-minimally coupled to the Ricci scalar. The critical surface in the space of theories is determined by the improved renormalization group flow which takes into account quantum corrections beyond the one loop approximation. The combination of constraints deriving from Planck observations and those from theory puts severe bounds on the values of the parameters of the model and predicts a quite large tensor to scalar ratio. We finally comment on the dependence of the results on the definition of the infrared energy scale which parametrises the running on the critical surface.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental and Numerical Study on the Effect of Annular Combustor Design on Thermal Uniformity Jet in Crossflow

Abstract Non-uniformity of the exit flow temperature represents one of the significant damages to gas-turbine components, particularly turbine blades. This may occur in the course of gas-turbine operation. This paper aims to provide passive techniques by modifying the combustor design rather than changing the flow parameters to improve the thermal uniformity and turbine blades to reduce thermal stresses and increase turbine blades’ life span. An acceptable agreement between the numerical and experimental results has been achieved, and the agreement includes the velocity and temperature profile. Four different angles have been tested numerically and experimentally with a maximum error of 5% at two different Reynolds numbers. Designing the outer combustor surface with a 45-deg angle bend can give a more uniform temperature distribution of 37% higher than the basic design with only a 0.5% higher pressure drop.

Energy & Fuels↗

Retrofitting a 1960s Split-Level, Cold-Climate Home

National programs such as Home Performance with ENERGY STAR® and numerous other utility air-sealing programs have made homeowners aware of the benefits of energy-efficiency retrofits. Yet these programs tend to focus only on the low-hanging fruit: they recommend air sealing the thermal envelope and ductwork where accessible, switching to efficient lighting and low-flow fixtures, and improving the efficiency of mechanical systems (though insufficient funds or lack of knowledge to implement these improvements commonly prevent the implementation of these higher cost upgrades). At the other end of the spectrum, various utilities across the country are encouraging deep energy retrofit programs. Although deep energy retrofits typically seek 50% energy savings, they are often quite costly and are most applicable to gut-rehab projects. A significant potential for lowering energy use in existing homes lies between the lowhanging fruit and deep energy retrofit approaches—retrofits that save approximately 30% in energy compared to the pre-retrofit conditions. The energy-efficiency measures need to be nonintrusive so the retrofit projects can be accomplished in occupied homes.

1960 split level↗

Energy to Communities Program Short Introduction: Evaluation of Enhanced Geothermal System for Cornell District Heating [Slides]

Through the U.S. Department of Energy's Energy to Communities (E2C) program, NLR, other national laboratory experts, and select organizations provide Expert Match - free, short-term technical assistance to address near-term energy challenges and questions. Expert Match is for community stakeholders who have decision-making power or influence in their community but need access to additional energy expertise to inform key upcoming decisions. This Expert Match request supported Cornell University (Itaca, NY) community efforts in developing Enhanced Geothermal System (EGS) reservoir performance, by simulating fracture flow to estimate pressure drop, flow distribution, and heat extraction efficiency in fractured rock. Thermal drawdown modeling was used to assess long-term resource sustainability, while system optimization studies refined key parameters such as well configuration and flow rate to improve overall reservoir efficiency.

15 GEOTHERMAL ENERGY↗

State Estimation in Low-Observable Distribution Systems Using Matrix Completion: Preprint

The need for distribution system state estimation is on the rise because of the increased penetration of distributed energy resources and flexible load. To manage the distribution systems in real time, operators need to first overcome the challenge of low observability in distribution systems. Also, because of the amount of data present from smart meters, distributed generation measurements, switches, etc., the ideal distribution state estimation methods need to be able to process heterogeneous data. In this paper, an algorithm is developed for voltage phasor estimation in low-observability distribution systems. The algorithm is based on the matrix completion approach from signal processing. The traditional matrix completion formulation is augmented with power-flow constraints to improve results while requiring less data. This method can also use all types of measurements (voltage magnitude, voltage angle, real power, reactive power) to complete the state matrix.

24 POWER TRANSMISSION AND DISTRIBUTION↗