Anion and pH effects on the potentials of zero charge of gold and silver electrodes.
Equality conditions for gold and silver electrode zero charge and transient peak potentials by pH and anion effects, using scraped electrodes
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Equality conditions for gold and silver electrode zero charge and transient peak potentials by pH and anion effects, using scraped electrodes
Several types of detectors are reviewed. The principle of operation and properties of ionization and wire chambers, semiconductor detectors, scintillation detectors are briefly discussed.
The chemical equilibrium between self-ionized and molecular water dictates the acid–base chemistry in aqueous solutions, yet understanding the microscopic mechanisms of water self-ionization remains experimentally and computationally challenging. Herein, Density Functional Theory (DFT)–based deep neural network (DNN) potentials are combined with enhanced sampling techniques and a global acid–base collective variable to perform extensive atomistic simulations of water self-ionization for model systems of increasing size. The explicit inclusion of long-range electrostatic interactions in the DNN potential is found to be crucial to accurately reproduce the DFT free energy profile of solvated water ion pairs in small (64 and 128 H 2 O) cells. The reversible work to separate the hydroxide and hydronium to a distance S is found to converge for simulation cells containing more than 500 H 2 O, and a distance of ∼ 8 Å is the threshold beyond which the work to further separate the two ions becomes approximately zero. The slow convergence of the potential of mean force with system size is related to a restructuring of water and an increase of the local order around the water ions. Calculation of the dissociation equilibrium constant illustrates the key role of long-range electrostatics and entropic effects in the water autoionization process.
G3(MP2)//B3 theory was modified to incorporate compact effective potential (CEP) pseudopotentials, providing a theoretical alternative referred to as G3(MP2)//B3-CEP for calculations involving first-, second-, and third-row representative elements. The G3/05 test set was used as a standard to evaluate the accuracy of the calculated properties. G3(MP2)//B3-CEP theory was applied to the study of 247 standard enthalpies of formation, 104 ionization energies, 63 electron affinities, 10 proton affinities, and 22 atomization energies, comprising 446 experimental energies. The mean absolute deviations compared with the experimental data for all thermochemical results presented an accuracy of 1.4 kcal mol{sup −1} for G3(MP2)//B3 and 1.6 kcal mol{sup −1} for G3(MP2)//B3-CEP. Approximately 75% and 70% of the calculated properties are found with accuracy between ±2 kcal mol{sup −1} for G3(MP2)//B3 and G3(MP2)//B3-CEP, respectively. Considering a confidence interval of 95%, the results may oscillate between ±4.2 kcal mol{sup −1} and ±4.6 kcal mol{sup −1}, respectively. The overall statistical behavior indicates that the calculations using pseudopotential present similar behavior with the all-electron theory. Of equal importance to the accuracy is the CPU time, which was reduced by between 10% and 40%.
Purpose: Accurate dose measurement in radiotherapy is critically dependent on correction for gain drop, which is the difference of the measured current from the ideal saturation current due to general ion recombination. Although a correction method based on the Boag theory has been employed, the theory assumes that ionized charge density in an ionization chamber (IC) is spatially uniform throughout the irradiation volume. For particle pencil beam scanning, however, the charge density is not uniform, because the fluence distribution of a pencil beam is not uniform. The aim of this study was to verify the effect of the nonuniformity of ionized charge density on the gain drop due to general ion recombination. Methods: The authors measured the saturation curve, namely, the applied voltage versus measured current, using a large plane-parallel IC and 24-channel parallel-plate IC with concentric electrodes. To verify the effect of the nonuniform ionized charge density on the measured saturation curve, the authors calculated the saturation curve using a method which takes into account the nonuniform ionized charge density and compared it with the measured saturation curves. Results: Measurement values of the different saturation curves in the different channels of the concentric electrodes differed and were consistent with the calculated values. The saturation curves measured by the large plane-parallel IC were also consistent with the calculation results, including the estimation error of beam size and of setup misalignment. Although the impact of the nonuniform ionized charge density on the gain drop was clinically negligible with the conventional beam intensity, it was expected that the impact would increase with higher ionized charge density. Conclusions: For pencil beam scanning, the assumption of the conventional Boag theory is not valid. Furthermore, the nonuniform ionized charge density affects the prediction accuracy of gain drop when the ionized charge density is increased by a higher dose rate and/or lower beam size.
A computational modeling study of high-voltage nanosecond pulsed microdischarge in xenon gas at 10 atm is presented. The discharge is observed to develop as two streamers originating from the cathode and the anode, and propagating toward each other until they merge to form a single continuous discharge channel. The peak plasma density obtained in the simulations is ∼10{sup 24 }m{sup −3}, i.e., the ionization degree of plasma does not exceed 1%. The influence of the initial gas pre-ionization is established. It is seen that an increase in the seeded plasma density results in an increase in the streamer propagation velocity and an increase in the plasma density obtained after the merging of two streamers.
ABSTRACT In this work, we revisit the size–luminosity relation of the extended narrow line regions (ENLRs) using a large sample of nearby active galactic nuclei (AGNs) from the Mapping Nearby Galaxies at Apache Point Observatory (MaNGA) survey. The ENLRs ionized by the AGN are identified through the spatially resolved BPT diagram, which results in a sample of 152 AGN. By combining our AGN with the literature high-luminosity quasars, we found a tight log-linear relation between the size of the ENLR and the AGN $\rm [O\, III]$λ5007 Å luminosity over four orders of magnitude of the $\rm [O\, III]$ luminosity. The slope of this relation is 0.42 ± 0.02 which can be explained in terms of a distribution of clouds photoionized by the AGN. This relation also indicates that the AGNs have the potential to ionize and heat the gas clouds at a large distance from the nuclei without the aids of outflows and jets for the low-luminosity Seyferts.†
A formula is proposed for calculating the rate of field ionisation of an atom or ion, taking into account both tunnel ionisation and barrier suppression ionisation. Compared with the previous formula proposed in 2018, it more accurately describes the transition region between both ionisations and is determined mainly by two parameters: the ionisation potential of an atom or ion and the amplitude of an external electric field. This makes the presented formula suitable for use in numerical packages simulating the interaction of high-power laser radiation with matter by the particle-in-cell (PIC) method. (paper)
Within the framework of the time-dependent effective range theory, we have calculated the spectra of high harmonics in a field containing an intense low-frequency component and a weak (perturbative) high-frequency component with a photon energy exceeding the ionisation potential of the atomic target. We have presented a quantum-mechanical substantiation of the quasi-classical theory [A.V. Flegel et al. Quantum Electron., 47, 222 (2017)], which describes additional generation channels of high harmonics induced by a weak high-frequency field. (paper)
The ternary V-VI-VII chalcohalides consist of one cation and two anions. Trivalent antimony—with a distinctive 5s{sup 2} electronic configuration—can be combined with a chalcogen (e.g., S or Se) and halide (e.g., Br or I) to produce photoactive ferroelectric semiconductors with similarities to the Pb halide perovskites. We report—from relativistic quasi-particle self-consistent GW theory—that these materials have a multi-valley electronic structure with several electron and hole basins close to the band extrema. We predict ionisation potentials of 5.3–5.8 eV from first-principles for the three materials, and assess electrical contacts that will be suitable for achieving photovoltaic action from these unconventional compounds.
Brueckner orbitals are the optimal orbitals for use in F12 explicitly correlated coupled-cluster (CC) treatments. A novel approach, Brueckner coupled-cluster doubles with perturbative triples BCCD(T){sub (F12*)} is presented that avoids the expensive re-evaluation of F12 integrals throughout the orbital optimisation and includes a newly derived basis set correction to the Brueckner reference energy. The generalisation of F12 theory to arbitrary non-Hartree–Fock references and to Fock operators that include scalar relativistic effects is also presented. The performance of the new Brueckner F12 method is assessed for a test set of 50 open- and closed-shell reactions and for the ionisation potentials and electron affinities (EAs) of the first-row transition metal atoms. Benchmark basis set limit coupled-cluster singles, doubles and perturbative triples (CCSD(T)) and BCCD(T) values are reported for all energies in the test sets. BCCD(T){sub (F12*)} performs systematically better than CCSD(T)(F12*) for electron affinities where orbital relaxation effects are significant.
When self-sputtering is driven far above the runaway threshold voltage, energetic electrons are made available to produce 'excess plasma' far from the magnetron target. Ionization balance considerations show that the secondary electrons deliver the necessary energy to the 'remote' zone. Thereby, such a system can be an extraordinarily prolific generator of usable metal ions. Contrary to other known sources, the ion current to a substrate can exceed the discharge current. For gasless self-sputtering of copper, the usable ion current scales exponentially with the discharge voltage.
Ionization of an atom by a few-cycle attosecond xuv pulse is analyzed using perturbation theory (PT), keeping terms in the transition amplitude up to second order in the pulse electric field. Within the PT approach, we present an ab initio parametrization of the ionized electron angular distribution (AD) using rotational invariance and symmetry arguments. This parametrization gives analytically the dependence of the AD on the carrier envelope phase (CEP), the polarization of the pulse, and on the ionized electron momentum direction, p. For the general case of an elliptically polarized pulse, we show that interference of the first- and second-order transition amplitudes causes a CEP-dependent asymmetry (with respect to p->-p) and both elliptic and circular dichroism effects. All of these effects are maximal in the polarization plane and depend not only on the CEP but also on the phase of dynamical atomic parameters that enter our parametrization of the AD. Within the single active electron model of an atom, for an initial s or p state we define all dynamical parameters in terms of radial matrix elements (analytic expressions for which are given for the Coulomb and zero-range potentials). For ionization of the H atom by linearly polarized pulses, our PT results are in excellent agreement with results of numerical solutions of the time-dependent Schroedinger equation of Peng et al.[New J. Phys. 10, 025030 (2008)]. Also, our numerical results show that the asymmetries and dichroism effects at low electron energies have a different physical origin from those at high electron energies. Moreover, our results for Gaussian and cosine-squared pulse shapes are in good qualitative agreement. Finally, we show that our analytic formulas may prove useful for determining few-cycle extreme ultraviolet (xuv) pulse characteristics, such as the CEP and the polarization.
Tour Leader: Xia Jiang, Ohio State University, Columbus, OH Tour Guides: Xia Jiang, Ohio State University, Columbus, OH Kevin Little, The University of Chicago, Chicago, IL Christina Sammet, Lurie Children’s Hospital of Chicago, Chicago, IL Participating Vendors: IBA PTW - New York Radcal Corporation RTI Electronics, Inc. Exhibit Hall Guided Tours is a new program launching this year at the Annual Meeting. The Guided Tours are designed to enhance the interaction between meeting attendees and exhibitors. This year’s Imaging Guided Tours are organized around the theme of dosimeters for quality control in diagnostic imaging. Tours will begin with an introduction and background given by Dr. Xia Jiang, the Tour Leader. The introduction will cover the types and properties of different radiation dosimeters used for quality assurance in clinical radiology. Attendees will then break into smaller groups, each lead by an AAPM-member Tour Guide. The tour groups will visit the exhibit booths of vendors who provide appropriate dosimeters, and a vendor representative will give a presentation to the group about their particular product(s). The vendor representatives as well as the Tour Guides will be available to answer questions. Outline: Types and properties of radiation detectors and dosimeters Ionization chamber dosimeters Solid state dosimeters Dosimeter calibration: Primary and secondary standards dosimetry laboratories Instruments for measuring tube voltage and exposure time Vendor presentations will likely cover features and innovations of different dosimeter systems, as well as their practical use. Learning Objectives: Understand the types and properties of different instrumentations used for quality control in diagnostic imaging. Understand the process of dosimeter calibration. Gain familiarity with the latest commercial dosimeter systems from different vendors.
Tour Leader: Xia Jiang, Ohio State University, Columbus, OH Tour Guides: Xia Jiang, Ohio State University, Columbus, OH Kevin Little, The University of Chicago, Chicago, IL Adrien Sanchez, University of Chicago, Chicago, IL Participating Vendors: IBA PTW - New York Radcal Corporation RTI Electronics, Inc. Exhibit Hall Guided Tours is a new program launching this year at the Annual Meeting. The Guided Tours are designed to enhance the interaction between meeting attendees and exhibitors. This year’s Imaging Guided Tours are organized around the theme of dosimeters for quality control in diagnostic imaging. Tours will begin with an introduction and background given by Dr. Xia Jiang, the Tour Leader. The introduction will cover the types and properties of different radiation dosimeters used for quality assurance in clinical radiology. Attendees will then break into smaller groups, each lead by an AAPM-member Tour Guide. The tour groups will visit the exhibit booths of vendors who provide appropriate dosimeters, and a vendor representative will give a presentation to the group about their particular product(s). The vendor representatives as well as the Tour Guides will be available to answer questions. Outline: Types and properties of radiation detectors and dosimeters Ionization chamber dosimeters Solid state dosimeters Dosimeter calibration: Primary and secondary standards dosimetry laboratories Instruments for measuring tube voltage and exposure time Vendor presentations will likely cover features and innovations of different dosimeter systems, as well as their practical use. Learning Objectives: Understand the types and properties of different instrumentations used for quality control in diagnostic imaging. Understand the process of dosimeter calibration. Gain familiarity with the latest commercial dosimeter systems from different vendors.
Tour Leader: Xia Jiang, Ohio State University, Columbus, OH Tour Guides: Xia Jiang, Ohio State University, Columbus, OH Kevin Little, The University of Chicago, Chicago, IL Adrien Sanchez, University of Chicago, Chicago, IL Participating Vendors: IBA PTW - New York Radcal Corporation RTI Electronics, Inc. Exhibit Hall Guided Tours is a new program launching this year at the Annual Meeting. The Guided Tours are designed to enhance the interaction between meeting attendees and exhibitors. This year’s Imaging Guided Tours are organized around the theme of dosimeters for quality control in diagnostic imaging. Tours will begin with an introduction and background given by Dr. Xia Jiang, the Tour Leader. The introduction will cover the types and properties of different radiation dosimeters used for quality assurance in clinical radiology. Attendees will then break into smaller groups, each lead by an AAPM-member Tour Guide. The tour groups will visit the exhibit booths of vendors who provide appropriate dosimeters, and a vendor representative will give a presentation to the group about their particular product(s). The vendor representatives as well as the Tour Guides will be available to answer questions. Outline: Types and properties of radiation detectors and dosimeters Ionization chamber dosimeters Solid state dosimeters Dosimeter calibration: Primary and secondary standards dosimetry laboratories Instruments for measuring tube voltage and exposure time Vendor presentations will likely cover features and innovations of different dosimeter systems, as well as their practical use. Learning Objectives: Understand the types and properties of different instrumentations used for quality control in diagnostic imaging. Understand the process of dosimeter calibration. Gain familiarity with the latest commercial dosimeter systems from different vendors.
The influence of the magnetic field of a laser pulse and the depletion of bound levels of working-medium atoms on the generation of high harmonics of mid-IR laser radiation in gases is investigated using numerical quantum-mechanical calculations. The maximum attainable spectral widths of high harmonics are estimated for model atoms with different ionisation potentials taking into account the aforementioned limiting effects. It is shown (within a two-dimensional model) that high harmonics with wavelengths to several angstroms can be generated by irradiating helium atoms with high-power femtosecond pulses of a laser [5] with a centre wavelength of 3.9 {mu}m. The possibility of observing experimentally relativistic effects using modern desktop mid-IR laser sources is demonstrated. (extreme light fields and their applications)
Results are presented from experimental and computational studies of a subnanosecond breakdown of atmospheric-pressure air in a nonuniform electric field. It is shown that the ionization waves (streamers) formed in the prebreakdown stage have a nearly spherical or conical shape. The diameter of the streamer in its widest part is found to increase with increasing voltage and discharge gap length. For a rise time of the voltage pulse of ≈0.5 ns and its amplitude of ≈250 kV, streamers about 8 cm in diameter were observed in a 7-cm-long gap.