Search NASA⌕ Search

SEARCH · Search NASA

Results for “model predictive controller”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Sensor enabled data-driven predictive analytics for modeling and control with high penetration of DERs in distribution systems

The electric power grid is undergoing a tremendous transformation due to the increasing penetration of renewable energy resources beginning with wind and more recently with the distributed energy resources (DERs) such as solar and battery storage. DERs have dramatically changed the role of the distribution systems in the overall power grid, and they are expected to contribute a significant portion of power generation in the future. If current trends for DERs continue, system operation and control will need to change dramatically for improved grid reliability and resiliency. As renewable resources increase in penetration, new and challenging operational, planning, and design problems are expected to emerge. Some of the key challenges that arise in the planning and operation of the future grid are: 1) Quantifying the impact of high DER penetration in distribution systems on bulk grid behavior over multiple time scales. 2) Identifying whether a particular DER configuration/settings have a large impact on the overall grid behavior. These challenges can be addressed in an offline manner using detailed T&D grid models and they can also be addressed in an online manner using sensor measurements. In particular, the advancement and planned growth in sensor technology in power grid over various voltage levels provide us with a unique opportunity to tackle these challenges from a data analytic perspective without needing detailed T&D grid models. A few questions that naturally arise when addressing the challenges from DERs using sensor data are: 1) How can we use limited sensor measurements to monitor & control voltage stability and small signal stability of the bulk system? 2) How can we ensure that the developed data analytic methods are robust to data availability and quality issues? 3) How can we compute the developed analytics in a scalable manner using streaming measurements? In this project, we addressed the aforementioned challenges arising from DERs and answered the questions raised above on how to effectively use the sensor measurements to enhance the reliability and performance of the electric grid. Thus, the overarching goal of this project is to develop effective reduced/representative system models from data that make the computational complexity sufficiently manageable so as to be useful to simulate, analyze, and even control complex non-linear power systems dynamics with large penetrations of DERs. In order to achieve the objective, the project team established a four-fold technical approach 1) Formulated a combined transmission-distribution co-simulation framework for data generation and validation, 2) Derived reduced/representative models of power systems based on data-driven methods for efficient computation and appropriate representation of system behavior, 3) Developed data driven characterization of power system behavior based on transfer operator theory, machine learning and optimization for model estimation, 4) Incorporated a scalable data management and processing architecture using distributed Kafka streaming applications that coordinate input data streams to the developed data analytics. The key accomplishments of the project are: 1) Development of a scalable multi-timescale T&D co-simulation framework (both for steady state and for dynamic co-simulation) using commercial solvers (PSSE and GridLAB-D). The steady-state T&D co-simulation interface is shared with our industry partner (PJM). 2) A structured reduced order dynamic model of distribution systems that can represent partial motor stalling along with a systematic procedure to derive the model parameters. 3) A PMU based online method to monitor, localize and mitigate fault-induced delayed voltage recovery using DER reactive support and load control in distribution systems. 4) Development of linear operator based robust methodologies for dynamic state estimation, uncertainty quantification, system identification and trajectory prediction for power system dynamics. 5) An adaptive damping control for utilizing wind energy resources to provide oscillation damping and system stability. 6) Implementation of Kafka-based framework for efficient processing of streaming data using Linux-based local virtual environment.

DER integration↗

Application of Artificial Neural Network Model for Optimized Control of Condenser Water Temperature Set-Point in a Chilled Water System

Here, in this study, real-time predictive control and optimization model based on an ANN (artificial neural network) was developed to evaluate the cooling energy saving performance of the optimized control of CndWT (condenser water temperature). For this purpose, the difference in TCEC (total cooling energy consumption) between the conventional control strategy when the CndWT produced by the cooling tower is fixed and the optimized control strategy when real-time control of the CndWT through the optimal ANN model is applied was compared and analyzed. For the modeling of the building to be simulated, the co-simulation of EnergyPlus and MATLAB was built through the middleware Building Controls Virtual Test Bed. For the prediction of TCEC, an ANN model was developed through MATLAB's neural network toolbox. The model accuracy of the ANN was examined through Cv(RMSE) index and as a result, Cv(RMSE) of the optimized ANN model turned out to be approximately 25 %. More importantly, the predictive control technique was able to save TCEC by 5.6 % compared to the conventional control method constantly fixing CndWT set-point to 30 °C. These results showed that the CndWT needs to be dynamically controlled using artificial intelligence technique such as ANN model and that significant energy savings were achievable compared to the conventional fixed control.

42 ENGINEERING↗

The effects of voice and manual control mode on dual task performance

Two fundamental principles of human performance, compatibility and resource competition, are combined with two structural dichotomies in the human information processing system, manual versus voice output, and left versus right cerebral hemisphere, in order to predict the optimum combination of voice and manual control with either hand, for time-sharing performance of a dicrete and continuous task. Eight right handed male subjected performed a discrete first-order tracking task, time-shared with an auditorily presented Sternberg Memory Search Task. Each task could be controlled by voice, or by the left or right hand, in all possible combinations except for a dual voice mode. When performance was analyzed in terms of a dual-task decrement from single task control conditions, the following variables influenced time-sharing efficiency in diminishing order of magnitude, (1) the modality of control, (discrete manual control of tracking was superior to discrete voice control of tracking and the converse was true with the memory search task), (2) response competition, (performance was degraded when both tasks were responded manually), (3) hemispheric competition, (performance degraded whenever two tasks were controlled by the left hemisphere) (i.e., voice or right handed control). The results confirm the value of predictive models invoice control implementation.

Wickens, C. D.↗

Active/Passive Control of Sound Radiation from Panels using Constrained Layer Damping

A hybrid passive/active noise control system utilizing constrained layer damping and model predictive feedback control is presented. This system is used to control the sound radiation of panels due to broadband disturbances. To facilitate the hybrid system design, a methodology for placement of constrained layer damping which targets selected modes based on their relative radiated sound power is developed. The placement methodology is utilized to determine two constrained layer damping configurations for experimental evaluation of a hybrid system. The first configuration targets the (4,1) panel mode which is not controllable by the piezoelectric control actuator, and the (2,3) and (5,2) panel modes. The second configuration targets the (1,1) and (3,1) modes. The experimental results demonstrate the improved reduction of radiated sound power using the hybrid passive/active control system as compared to the active control system alone.

Gibbs, Gary P.↗

A Multiple Agent Model of Human Performance in Automated Air Traffic Control and Flight Management Operations

A predictive model of human operator performance (flight crew and air traffic control (ATC)) has been developed and applied in order to evaluate the impact of automation developments in flight management and air traffic control. The model is used to predict the performance of a two person flight crew and the ATC operators generating and responding to clearances aided by the Center TRACON Automation System (CTAS). The purpose of the modeling is to support evaluation and design of automated aids for flight management and airspace management and to predict required changes in procedure both air and ground in response to advancing automation in both domains. Additional information is contained in the original extended abstract.

Corker, Kevin↗

Empirical Modeling of Direct Expansion (DX) Cooling System for Multiple Research Use Cases

This study provides a general procedure to generate a direct expansion (DX) cooling coil system for a roof top unit (RTU), which is a typical heating ventilation and air-conditioning (HVAC) system for commercial buildings in the United States. Experimental data from a full-scale unoccupied 2-story commercial building is used for the HVAC modeling. The regression for identifying the model coefficients was carried out with multiple stages, and the results were validated with measured data. The model’s applicability was evaluated with multiple case studies, including a building energy simulation (BES) program validation, model-based predictive control (MPC), and fault diagnostics and detection (FDD).

42 ENGINEERING↗

Physics-based control-oriented modeling of the current density profile evolution in NSTX-Upgrade

Active control of the toroidal current density profile is among those plasma control milestones that the National Spherical Torus eXperiment-Upgrade (NSTX-U) program must achieve to realize its next-step operational goals. Motivated by the coupled, nonlinear, multivariable, distributed-parameter plasma dynamics, the first step towards control design is the development of a physics-based, control-oriented model for the current profile evolution in response to non-inductive current drives and heating systems. The evolution of the toroidal current density profile is closely related to the evolution of the poloidal magnetic flux profile, whose dynamics is modeled by a nonlinear partial differential equation (PDE) referred to as the magnetic-flux diffusion equation (MDE). The proposed control-oriented model predicts the spatial-temporal evolution of the current density profile by combining the nonlinear MDE with physics-based correlations obtained at NSTX-U for the electron density, electron temperature, and non-inductive current drives (neutral beams). The resulting first-principles-driven, control-oriented model is tailored for NSTX-U based on predictions by the time-dependent transport code TRANSP. Furthermore, main objectives and possible challenges associated with the use of the developed model for the design of both feedforward and feedback controllers are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Active learning strategy for high fidelity short-term data-driven building energy forecasting

The quality of a data-driven model is heavily dependent on the quality of data. Data from building operation often have data bias problems, which means that the data sample is collected in a way that some members of the intended data population are less likely to be included than others. Data-driven energy forecasting models built on such data hence are biased and could lead to large forecasting errors. Active learning—an effective method to defying data bias—is rarely studied or applied in the area of data-driven building energy forecasting modeling. This paper attempts to fill this gap and explores the application of active learning in data-driven building energy forecasting. The developed strategy in this paper efficiently generate informative training data within a time budget and uses block design to passively consider weather disturbances. The developed active learning strategy is applied and evaluated in both virtual and real-building testbeds against traditional data-driven methods. Via these virtual and real-building evaluation cases, we have demonstrated that the data bias problem typically exists in building operation data is resolved by applying the developed active learning strategy. Furthermore, building energy forecasting models trained from data generated from the active learning strategy have shown improved performances in both model accuracy and model extendibility perspectives. The effectiveness of the block design module is also validated to effectively consider the impact of weather conditions on active learning design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hardware-Based Emulator with Deep Learning Model for Building Energy Control and Prediction Based on Occupancy Sensors’ Data

Heating, ventilation, and air conditioning (HVAC) is the largest source of residential energy consumption. Occupancy sensors’ data can be used for HVAC control since it indicates the number of people in the building. HVAC and sensors form a typical cyber-physical system (CPS). In this paper, we aim to build a hardware-based emulation platform to study the occupancy data’s features, which can be further extracted by using machine learning models. In particular, we propose two hardware-based emulators to investigate the use of wired/wireless communication interfaces for occupancy sensor-based building CPS control, and the use of deep learning to predict the building energy consumption with the sensor data. We hypothesize is that the building energy consumption may be predicted by using the occupancy data collected by the sensors, and question what type of prediction model should be used to accurately predict the energy load. Another hypothesis is that an in-lab hardware/software platform could be built to emulate the occupancy sensing process. The machine learning algorithms can then be used to analyze the energy load based on the sensing data. To test the emulator, the occupancy data from the sensors is used to predict energy consumption. The synchronization scheme between sensors and the HVAC server will be discussed. We have built two hardware/software emulation platforms to investigate the sensor/HVAC integration strategies, and used an enhanced deep learning model—which has sequence-to-sequence long short-term memory (Seq2Seq LSTM)—with an attention model to predict the building energy consumption with the preservation of the intrinsic patterns. Because the long-range temporal dependencies are captured, the Seq2Seq models may provide a higher accuracy by using LSTM architectures with encoder and decoder. Meanwhile, LSTMs can capture the temporal and spatial patterns of time series data. The attention model can highlight the most relevant input information in the energy prediction by allocating the attention weights. The communication overhead between the sensors and the HVAC control server can also be alleviated via the attention mechanism, which can automatically ignore the irrelevant information and amplify the relevant information during CNN training. Our experiments and performance analysis show that, compared with the traditional LSTM neural network, the performance of the proposed method has a 30% higher prediction accuracy.

Ye, Zhijing↗

On the internal target model in a tracking task

An optimal control model for predicting operator's dynamic responses and errors in target tracking ability is summarized. The model, which predicts asymmetry in the tracking data, is dependent on target maneuvers and trajectories. Gunners perception, decision making, control, and estimate of target positions and velocity related to crossover intervals are discussed. The model provides estimates for means, standard deviations, and variances for variables investigated and for operator estimates of future target positions and velocities.

Caglayan, A. K.↗

Peak Reduction Using Mode Adjustment of Heat Pump Water Heaters in a Residential Neighborhood

Building electrification is putting pressure on distribution grid worldwide. Peak reduction is an important concern that can help reduce the growing stress and allow to defer investments in new capacity. Water heaters represent a convenient way of reducing peak because they are less dependent on weather, and their storage volume allows for asynchronous water heating and hot water use. Previous empirical studies investigated the ability of water heaters to reduce peak through the adjustment of the temperature setpoint. However, not all equipment vendors offer this option. This study aims at understanding the feasibility of peak reduction with an alternative configuration available in the market - by adjusting the device mode rather than temperature setpoint. The peak reduction methodology is tested in an occupied 46-townhome neighborhood located in Atlanta, GA. We find that peak shifting is possible with the adjustable mode approach, with the change in the peak load by 30-60%.

demand response↗

Adaptive Urban Traffic Signal Control for Multiple Intersections: An LQR Approach

Traffic congestion leads to severe problems especially in urban traffic networks. It increases the chance of accidents, energy waste, and social costs. In order to address these problems, an adaptive linear quadratic regulator (LQR) approach is developed for traffic signal control at multiple intersections in an urban area. The proposed method controls the green time of the traffic signals to reduce traffic congestion and smooth traffic flow. Real-world data from vision-based traffic sensors are used to build the traffic network model, which mimics the real-world traffic behavior. In addition, the proposed control utilizes recursive least square parameter estimation, which is capable of tracking dynamic changes in traffic conditions. Simulation of Urban MObility (SUMO) is used to analyze the efficacy of the proposed method. Results of the simulation show that the proposed method outperforms pretimed control in various aspects.

adaptive LQR control↗

Occupancy-Based HVAC Control with Short-Term Occupancy Prediction Algorithms for Energy-Efficient Buildings

This study aims to develop a concrete occupancy prediction as well as an optimal occupancy-based control solution for improving the efficiency of Heating, Ventilation, and Air-Conditioning (HVAC) systems. Accurate occupancy prediction is a key enabler for demand-based HVAC control so as to ensure HVAC is not run needlessly when when a room/zone is unoccupied. In this paper, we propose simple yet effective algorithms to predict occupancy alongside an algorithm for automatically assigning temperature set-points. Utilizing past occupancy observations, we introduce three different techniques for occupancy prediction. Firstly, we propose an identification-based approach, which identifies the model via Expectation Maximization (EM) algorithm. Secondly, we study a novel finite state automata (FSA) which can be reconstructed by a general systems problem solver (GSPS). Thirdly, we introduce an alternative stochastic model based on uncertain basis functions. The results show that all the proposed occupancy prediction techniques could achieve around 70% accuracy. Then, we have proposed a scheme to adaptively adjust the temperature set-points according to a novel temperature set algorithm with customers’ different discomfort tolerance indexes. By cooperating with the temperature set algorithm, our occupancy-based HVAC control shows 20% energy saving while still maintaining building comfort requirements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NEXT Generation Energy Technologies for Connected and Automated On-Road Vehicles (NEXTCAR Phase I & II)

The Ohio State University’s ARPA-E NEXTCAR project was a multi-phase, multi-year research, development, and demonstration program focused on improving the energy efficiency of connected and automated vehicles (CAVs). The team developed and validated advanced vehicle motion and powertrain control algorithms that coordinate propulsion and automation systems to optimize energy use. Key technologies included Dynamic Skip Fire engine control, predictive eco-driving functions such as Eco-Approach and Departure (Eco-AND) and Eco-Adaptive Cruise Control (Eco-ACC), and powertrain-agnostic optimization frameworks for hybrid, plug-in hybrid, and battery electric vehicles. The project successfully demonstrated up to 30% energy-efficiency improvement during real-world testing at the Transportation Research Center and the American Center for Mobility. The outcomes provide a foundation for scalable, cost-effective deployment of energy-optimized CAV technologies across the automotive industry.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Standardized Data to Improve Understanding and Modeling of Soil Nitrogen at Continental Scale

Abstract Nitrogen (N) is a key limiting nutrient in terrestrial ecosystems, but there remain critical gaps in our ability to predict and model controls on soil N cycling. This may be in part due to lack of standardized sampling across broad spatial–temporal scales. Here, we introduce a continentally distributed, publicly available data set collected by the National Ecological Observatory Network (NEON) that can help fill these gaps. First, we detail the sampling design and methods used to collect and analyze soil inorganic N pool and net flux rate data from 47 terrestrial sites. We address methodological challenges in generating a standardized data set, even for a network using uniform protocols. Then, we evaluate sources of variation within the sampling design and compare measured net N mineralization to simulated fluxes from the Community Earth System Model 2 (CESM2). We observed wide spatiotemporal variation in inorganic N pool sizes and net transformation rates. Site explained the most variation in NEON’s stratified sampling design, followed by plots within sites. Organic horizons had larger pools and net N transformation rates than mineral horizons on a sample weight basis. The majority of sites showed some degree of seasonality in N dynamics, but overall these temporal patterns were not matched by CESM2, leading to poor correspondence between observed and modeled data. Looking forward, these data can reveal new insights into controls on soil N cycling, especially in the context of other environmental data sets provided by NEON, and should be leveraged to improve predictive modeling of the soil N cycle.

54 ENVIRONMENTAL SCIENCES↗