Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical wavefront”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Design and performance analysis of a PIAACMC coronagraph on a segmented aperture

The Phase-Induced Amplitude Apodization Complex Mask Coronagraph (PIAACMC) offers high throughput and small inner working angle (IWA) for direct imaging of exoplanets. PIAACMC is also compatible with segmented apertures, which is important for the success of future large telescopes, such as the Large UV / Optical/ Infrared (LUVOIR) concept currently under way to inform NASA's2020 decadal survey. We present a design of PIAACMC for one of the segmented apertures considered for LUVOIR and simulate its performance with wavefront control, in monochromatic as well as broadband light. We characterize its performance in terms of throughput, inner working angle, contrast, area of the dark zone, and sensitivity to low order aberrations, in particular tip/tilt. In addition, we study the resilience to large stellar angular sizes and polarization. Finally, we compute the "performance map", which is a recently introduced figure of merit for coronagraphs

Exoplanets↗

Integrated Modeling for the Next Generation Space Telescope "Yardstick" Concept

The so-called NASA "Yardstick" design concept for the Next Generation Space Telescope presents unique challenges for systems-level analysis. Simulations that integrate controls, optics, thermal, and structural models are required to evaluate baseline performance, study design sensitivities, and perform design optimization. An integrated modeling approach was chosen using a combination of commercial off-the-shelf and "in-house" developed codes. The resulting capability provides a foundation for linear and non-linear analysis, using both the time and frequency-domain methods. It readily allows various combinations of design parameters and environmental loads to be evaluated directly in terms of key science-related metrics, in this case the scalar RMS (root mean square) line-of-sight and RMS wavefront errors. This presentation first addresses the development of the component, or discipline, models for the Yardstick design. It will then proceed to present the integration of the component models, using linear-systems approaches, in order to support two of the most critical baseline performance analyses: jitter and thermal-elastic stability of the optical telescope assembly (OTA). The results of the jitter analysis indicate that disturbances from the reaction wheels coupled with the lightly-damped and highly-flexible structure present significant challenges to the baseline line-of-sight control architecture. Vibration isolation will be required to meet jitter error requirements. The results of the thermal-elastic analysis indicate that the mirror segment displacements due to ground-to-orbit cool-down of the telescope are within the expected capture range of the segment rigid-body control actuators. This means we will be able to align and phase the primary mirror. However, the results for the analysis of the thermal transient response following an attitude maneuver (slew) show that this telescope design is not sufficiently stable, passively, to meet the wavefront error requirements. Structural re-design is one possibility; alternatively, active thermal control of the OTA may be considered. The Yardstick integrated models were successfully used to demonstrate the feasibility of two thermal control strategies.

Mosier, Gary E.↗

Imprinting high-gradient topographical structures onto optical surfaces using magnetorheological finishing: Manufacturing corrective optical elements for high-power laser applications

Corrective optical elements form an important part of high-precision optical systems. We have developed a method to manufacture high-gradient corrective optical elements for high-power laser systems using deterministic magnetorheological finishing (MRF) imprinting technology. Several process factors need to be considered for polishing ultraprecise topographical structures onto optical surfaces using MRF. They include proper selection of MRF removal function and wheel sizes, detailed MRF tool and interferometry alignment, and optimized MRF polishing schedules. Dependable interferometry also is a key factor in high-gradient component manufacture. A wavefront attenuating cell, which enables reliable measurement of gradients beyond what is attainable using conventional interferometry, is discussed. The results of MRF imprinting a 23 μm deep structure containing gradients over 1.6 μm / mm onto a fused-silica window are presented as an example of the technique’s capabilities. As a result, this high-gradient element serves as a thermal correction plate in the high-repetition-rate advanced petawatt laser system currently being built at Lawrence Livermore National Laboratory.

42 ENGINEERING↗

The Parabolic Deformable Mirror Testbed at NASA Goddard Space Flight Center

One of the primary goals of future coronagraph space missions is to spectrally characterize Earth-like exoplanets. Observing efficiency is critical and directly related to how large of a field of view we can correct and the bandwidth of that correction. In addition to the coronagraph itself, the bandwidth and depth of contrast is related to the wavefront control system, which classically uses two deformable mirrors (DMs) in series. The minimum distance between these DMs is determined by the Talbot distance of the beam, meaning it scales as the square of the beam size. NASA Goddard is exploring an alternative design architecture to the two-DM approach in which the reimaging optics for the coronagraph are also deformable and we only retain a high-order pupil DM. With these off-axis parabolic elements being made deformable, the long propagation distance between the two DMs is eliminated. Goddard has procured an off-axis parabolic DM (PDM or OAP DM) from vendor ALPAO, France. A testbed is currently being built to test the PDM and demonstrate its utility for achieving high contrast in a coronagraph. The testbed is also being built with an integrated low-order wavefront sensing capability, allowing for integrated testing of a dynamic environment with multiple estimation and control loops.

Hari Subedi↗

Modal Filters for Infrared Interferometry

Modal filters in the approximately equal to 10-micrometer spectral range have been implemented as planar dielectric waveguides in infrared interferometric applications such as searching for Earth-like planets. When looking for a small, dim object ("Earth") in close proximity to a large, bright object ("Sun"), the interferometric technique uses beams from two telescopes combined with a 180 phase shift in order to cancel the light from a brighter object. The interferometer baseline can be adjusted so that, at the same time, the light from the dimmer object arrives at the combiner in phase. This light can be detected and its infrared (IR) optical spectra can be studied. The cancellation of light from the "Sun" to approximately equal to 10(exp 6) is required; this is not possible without special devices-modal filters- that equalize the wavefronts arriving from the two telescopes. Currently, modal filters in the approximately equal to 10-micrometer spectral range are implemented as single- mode fibers. Using semiconductor technology, single-mode waveguides for use as modal filters were fabricated. Two designs were implemented: one using an InGaAs waveguide layer matched to an InP substrate, and one using InAlAs matched to an InP substrate. Photon Design software was used to design the waveguides, with the main feature all designs being single-mode operation in the 10.5- to 17-micrometer spectral range. Preliminary results show that the filter's rejection ratio is 26 dB.

Ksendzov, Alexander↗

Wavefront Amplitude Variation of TPF's High Contrast Imaging Testbed: Modeling and Experiment

Knowledge of wavefront amplitude is as important as the knowledge of phase for a coronagraphic high contrast imaging system. Efforts have been made to understand various contributions of the amplitude variation in Terrestrial Planet Finder's (TPF) High Contrast Imaging Testbed (HCIT). Modeling of HCIT with as-built mirror surfaces has shown an amplitude variation of 1.3% due to the phase-amplitude mixing for the testbed's front-end optics. Experimental measurements on the testbed have shown the amplitude variation is about 2.5% with the testbed's illumination pattern has a major contribution as the low order amplitude variation.

coronagraph↗

Transverse mode analysis for free-space laser beams using Bayesian analysis

Reliable and rapid assessment of the transverse mode quality of a free-space laser beam has a wide range of applications in laser development, research, and utilization. It has become even more important with recent advances in developing orbital angular momentum photon beams across a broad spectral region. In this work, a general modal analysis method for a free-space multimode laser beam has been developed based on Bayesian analysis. After transforming mode decomposition into a linear system problem, a Gaussian probabilistic model is used to find a closed-form solution. The method is found to be robust with the presence of Gaussian noise. Prior knowledge about the mode content can be incorporated into the method to improve the solution for situations when coherent disturbances or contamination are present in the laser beam. This method can be used to analyze the mode content for laser beams in different bases, such as Hermite–Gaussian (HG) modes and Laguerre–Gaussian (LG) modes. Three applications of this method are presented: a detailed modal analysis of the beam image from the incoherent intensity addition of HG modes and two examples of mode decomposition using the complex wavefront from the coherent superposition of HG and LG modes. The feasibility of this method is demonstrated using various simulation results. Based on digital images of a laser beam recorded without complex wavelength-limiting optics, in principle, this method can be used in a wide wavelength range from infrared to ultraviolet, and possibly x ray.

Liu, Peifan (ORCID:0000000273816153)↗

Nonlinear discrete wavefront shaping for spatiotemporal pulse compression with multicore fibers

Here in this work, we apply an effective discrete phase front focusing method to control the coherent combining and temporal compression of laser pulses by means of nonlinear multicore fibers. We numerically demonstrate the possibility of combining almost entirely the input optical pulses injected in all cores, into the central core of a hexagonal lattice multicore fiber. We investigate the optimal operational conditions for the most effective pulse combining and analyze the influence of a positive input pulse temporal chirp and spatial phase modulation. We demonstrate that a pulse, which has been focused into an arbitrary core of the fiber, also undergoes temporal compression.

97 MATHEMATICS AND COMPUTING↗

Polarization Considerations

As light passes through a optical system the reflections and refractions will in general change the polarization state of the light. If we assume that all of the materials in the thin film coatings and substrate are isotropic and homogeneous then calculating the amount of "instrumental" polarization is a relatively straight forward task. In the following sections we will present a of the steps required to perform a 'polarization ray trace' calculation for a single ray and monochromatic and hence polarized light. The thin film portion of the calculation is also shown. The reason for explicitly showing the thin film equations is that there are sign conventions imposed on the boundary value equations by the orientation and handedness of the various coordinate frames which are attached to the geometric rays. The attenuation of light through a optical system, is relatively simple, and requires at the very least a lens (average) reflectivity or transmissivity. Determining the polarization sensitivity of a optical system is still relatively straight forward requiring at least a knowledge of the behavior of the "s" and "p" components at each interface for the chief ray. Determining the thin film induced aberrations of a optical system are somewhat more demanding. Questions about the arithmetic sign of the phase factors and how this relates to the overall "OPD" of a ray are ubiquitous. Many rays are required to construct a wavefront. Thin film codes which modify the OPD's of rays are a requirement for this last mentioned computation. This requires a consistent scheme of coordinate frames and sign conventions and is probably the most demanding task of a polarization ray trace. Only the electric field will used in the discussion. This is not a restriction as the Stokes parameters are functions of the electric field. The following does not attempt to explain, but only to present all of the required concepts and formulas.

Waluschka, Eugene↗

Ambient and Cryogenic Alignment Verification and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a facility instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low- to mid-resolving power (R = 300 - 3000). IRMOS produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arc-min field of view using a commercial Micro Electro-Mechanical Systems (MEMS) Digital Micro-mirror Device (DMD) from Texas Instruments. The IRMOS optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the DMD field stop, and the spectrograph images the DMD onto the detector. We describe ambient breadboard subsystem alignment and imaging performance of each stage independently, and the ambient and cryogenic imaging performance of the fully assembled instrument. Interferometric measurements of subsystem wavefront error serve to venfy alignment, and are accomplished using a commercial, modified Twyman-Green laser unequal path interferometer. Image testing provides further verification of the optomechanical alignment method and a measurement of near-angle scattered light due to mirror small-scale surface error. Image testing is performed at multiple field points. A mercury-argon pencil lamp provides spectral lines at 546.1 nm and 1550 nm, and a CCD camera and IR camera are used as detectors. We use commercial optical modeling software to predict the point-spread function and its effect on instrument slit transmission and resolution. Our breadboard test results validate this prediction. We conclude with an instrument performance prediction for first light.

Connelly, Joseph A.↗

Predictive Thermal Control (PTC) Technology to Enable Thermally Stable Telescopes

Validate models that predict thermal optical performance of real mirrors and structure based on their structural designs and constituent material properties, i.e. CTE distribution, thermal conductivity, thermal mass, etc.. Derive thermal system stability specifications from science-driven wavefront-stability requirement. Demonstrate utility of PTC system for achieving thermal stability.

Space Mirror Technology↗

Alignment and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a principle investigator class instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low-to mid-resolving power (R = 300 - 3000). IRMOS produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arc-min field of view (4 m telescope) using a commercial Micro Electro-Mechanical Systems (MEMS) micro-mirror array (MMA) from Texas Instruments. The IRMOS optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the MMA field stop, and the spectrograph images the MMA onto the detector. We describe ambient breadboard subsystem alignment and imaging performance of each stage independently, and ambient imaging performance of the fully assembled instrument. Interferometric measurements of subsystem wavefront error serve as a qualitative alignment guide, and are accomplished using a commercial, modified Twyman-Green laser unequal path interferometer. Image testing provides verification of the optomechanical alignment method and a measurement of near-angle scattered light due to mirror small-scale surface error. Image testing is performed at multiple field points. A mercury-argon pencil lamp provides a spectral line at 546.1 nanometers, a blackbody source provides a line at 1550 nanometers, and a CCD camera and IR camera are used as detectors. We use commercial optical modeling software to predict the point-spread function and its effect on instrument slit transmission and resolution. Our breadboard and instrument level test results validate this prediction. We conclude with an instrument performance prediction for cryogenic operation and first light in late 2003.

Connelly, Joseph A.↗

Ptychographic X-ray speckle tracking with multi-layer Laue lens systems

The ever-increasing brightness of synchrotron radiation sources demands improved X-ray optics to utilize their capability for imaging and probing biological cells, nano-devices and functional matter on the nanometre scale with chemical sensitivity. Hard X-rays are ideal for high-resolution imaging and spectroscopic applications owing to their short wavelength, high penetrating power and chemical sensitivity. The penetrating power that makes X-rays useful for imaging also makes focusing them technologically challenging. Recent developments in layer deposition techniques have enabled the fabrication of a series of highly focusing X-ray lenses, known as wedged multi-layer Laue lenses. Improvements to the lens design and fabrication technique demand an accurate, robust, in situ and at-wavelength characterization method. To this end, a modified form of the speckle tracking wavefront metrology method has been developed. The ptychographic X-ray speckle tracking method is capable of operating with highly divergent wavefields. A useful by-product of this method is that it also provides high-resolution and aberration-free projection images of extended specimens. Three separate experiments using this method are reported, where the ray path angles have been resolved to within 4 nrad with an imaging resolution of 45 nm (full period). This method does not require a high degree of coherence, making it suitable for laboratory-based X-ray sources. Likewise, it is robust to errors in the registered sample positions, making it suitable for X-ray free-electron laser facilities, where beam-pointing fluctuations can be problematic for wavefront metrology.

36 MATERIALS SCIENCE↗

Common path point diffraction interferometer using liquid crystal phase shifting

A common path point diffraction interferometer uses dyed, parallel nematic liquid crystals which surround an optically transparent microsphere. Coherent, collimated and polarized light is focused on the microsphere at a diameter larger than that of the microsphere. A portion of the focused light passes through the microsphere to form a spherical wavefront reference beam and the rest of the light is attenuated by the dyed liquid crystals to form an object beam. The two beams form an interferogram which is imaged by a lens onto an electronic array sensor and into a computer which determines the wavefront of the object beam. The computer phase shifts the interferogram by stepping up an AC voltage applied across the liquid crystals without affecting the reference beam.

Mercer, Carolyn R.↗

Experimental Estimation of CLASP Spatial Resolution: Results of the Instrument's Optical Alignment

The Chromospheric Lyman-Alpha SpectroPolarimeter (CLASP) is a sounding-rocket experiment currently being built at the National Astronomical Observatory of Japan. This instrument aims to probe for the first time the magnetic field strength and orientation in the solar upper-chromosphere and lower-transition region. CLASP will measure the polarization of the Lyman-Alpha line (121.6nm) with an unprecedented accuracy, and derive the magnetic field information through the Hanle effect. Although polarization accuracy and spectral resolution are crucial for the Hanle effect detection, spatial resolution is also important to get reliable context image via the slit-jaw camera. As spatial resolution is directly related with the alignment of optics, it is also a good way of ensuring the alignment of the instrument to meet the scientific requirement. This poster will detail the experiments carried out to align CLASP's optics (telescope and spectrograph), as both part of the instrument were aligned separately. The telescope was aligned in double-pass mode, and a laser interferometer (He-Ne) was used to measure the telescope's wavefront error (WFE). The secondary mirror tilt and position were adjusted to remove comas and defocus aberrations from the WFE. Effect of gravity on the WFE measurement was estimated and the final WFE derived in zero-g condition for CLASP telescope will be presented. In addition, an estimation of the spot shape and size derived from the final WFE will also be shown. The spectrograph was aligned with a custom procedure: because Ly-light is absorbed by air, the spectrograph's off-axis parabolic mirrors were aligned in Visible Light (VL) using a custom-made VL grating instead of the flight Ly- grating. Results of the alignment in Visible Light will be shown and the spot shape recorded with CCDs at various position along the slit will be displayed. Results from both alignment experiment will be compared to the design requirement, and will be combined in order to estimate CLASP spatial resolution after its alignment in visible light.

spatial resolution↗

Preparing the JWST Observatory for Science Observations

The James Webb Space Telescope (JWST) is a large (6.5 m) near-and mid-infrared telescope scheduled for launch in 2021. JWST will be used to explore fundamental questions in astrophysics and planetary science, including the evolution of galaxies, the first light of stars, the formation of stars and planets as well as the characterization of exoplanets. To achieve these scientific goals, NASA and its international partners, the Canadian Space Agency (CSA) and the European Space Agency (ESA), have developed four science instruments for JWST and have prepared detailed commissioning plans for each. The NASA Project Science team has also outlined activities to characterize the performance of the Observatory as a whole. These activities include: 1) monitoring of the instrument and telescope cooldown for contamination mitigation; 2) measurements of straylight and other backgrounds for validation of the JWST stray light models as well as instrument background subtraction algorithms; 3) characterization of optical thermal distortion between its hot and cold telescope pointings within the observable field of regard and 4) trending of observatory performance parameters. Each of these activities has been planned in close collaboration with the observatory wavefront, commissioning planning, and science instrument teams. Here we present the plans for these activities, the expected results and how they will impact future guest observer (GO) proposals and JWST science community

Erin C Smith↗

Pupil Alignment Considerations for Large, Deployable Space Telescopes

For many optical systems the properties and alignment of the internal apertures and pupils are not critical or controlled with high precision during optical system design, fabrication or assembly. In wide angle imaging systems, for instance, the entrance pupil position and orientation is typically unconstrained and varies over the system s field of view in order to optimize image quality. Aperture tolerances usually do not receive the same amount of scrutiny as optical surface aberrations or throughput characteristics because performance degradation is typically graceful with misalignment, generally only causing a slight reduction in system sensitivity due to vignetting. But for a large deployable space-based observatory like the James Webb Space Telescope (JWST), we have found that pupil alignment is a key parameter. For in addition to vignetting, JWST pupil errors cause uncertainty in the wavefront sensing process that is used to construct the observatory on-orbit. Furthermore they also open stray light paths that degrade the science return from some of the telescope s instrument channels. In response to these consequences, we have developed several pupil measurement techniques for the cryogenic vacuum test where JWST science instrument pupil alignment is verified. These approaches use pupil alignment references within the JWST science instruments; pupil imaging lenses in three science instrument channels; and unique pupil characterization features in the optical test equipment. This will allow us to verify and crosscheck the lateral pupil alignment of the JWST science instruments to approximately 1-2% of their pupil diameters.

Bos, Brent J.↗

Design and Predicted Performance of 4-m Baseline Habitable-Zone Exoplanet Observatory Telescope

The Habitable Exoplanet Observatory Mission (HabEx) is one of four missions which NASA is studying. Its goal is to directly image and spectroscopically characterize planets in the habitable zone around nearby sun-like stars. Additionally, HabEx would perform a broad range of general astrophysics science enabled by 115 to 1700 nm spectral range and 3x3 arc-minute FOV instruments. Critical to achieving its science goals is a large, ultra-stable UV/Optical/Near-IR (UVOIR) telescope. The baseline HabEx telescope is a 4-meter off-axis unobscured three-mirror-anastigmatic, diffraction limited at 400 nm with wavefront stability on the order of a few 10s of picometers. This paper summarizes how science driven systems engineering (using science requirements to derive engineering specifications) resulting in the opto-mechanical design of the HabEx baseline optical telescope assembly. And, how Structural Thermal Optical Performance (STOP) modeling predicts tolerance compliance.

H Philip Stahl↗