Circumpolar observations of thermokarst pool expansion from high-resolution satellite imagery
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
Report prepared for NDEP
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A fundamental yet outstanding question about deep cumulus convection regards how convective updrafts, downdrafts, and surface-based cold pools are inter-related within organized storms, and how these three convective components are modulated by external and internal factors. We considered this question through numerical model simulations as well as data collected during the MC3E field campaign. One of our basic hypotheses was that deep cold pools are forced by wide downdrafts which arise from wide updrafts. This “bottom-up” perspective required consideration of the external controls on updraft width, and then the internal controls on cold-pool characteristics including depth. Model experiments showed that environmental vertical wind shear (an external factor) exerts a particularly strong control on updraft width; analyses of linear and nonlinear dynamic pressure forcing readily explain this control. The experiments also showed that increases in updraft width are accompanied by corresponding increases in downdraft width and cold-pool depth. The updraft–downdraft connection is through precipitation: the wide area of precipitation that will be initiated in a wide updraft will in turn lead to a wide downdraft. The downdraft–cold pool connection is through mass continuity: at the downdraft terminus, the large downdraft mass flux through a wide downdraft must lead to a deep cold pool. Model experiments also showed that the cold-pool depth and other characteristics can be significantly modulated by microphysical processes (internal factors). Specifically, the cold-pool expansion rate, depth, and intensity was found to depend most strongly on the amount of rain evaporation near the ground. However, the sustenance of the cold pool itself depended upon the downdrafts strengthened by sublimation of graupel higher in the storm. Finally, field campaign data revealed compelling inter-relationships between the cold-pool characteristics, and downdraft transience in terms of the microphysics. For example, pulses of hail and graupel (also internal factors) within downdrafts resulted in short-lived increases in the cold-pool depth. However, the cold-pool speed appeared to be relatively independent of the cold-pool depth and intensity, suggesting limitations of density current theory to convective cold pools in nature.
The safety issue has been raised with regards to potential molten metal detachments from the weld pool and cold filler wire during electron beam welding in space. This investigation was undertaken to evaluate if molten metal could detach and come in contact with astronauts and burn through the fabric of the astronauts' Extravehicular Mobility Unit (EMU) during electron beam welding in space. Molten metal detachments from either the weld/cut substrate or weld wire could present harm to a astronaut if the detachment was to burn through the fabric of the EMU. Theoretical models were developed to predict the possibility and size of the molten metal detachment hazards during the electron beam welding exercises at Low Earth Orbit (LEO). The primary molten metal detachment concerns were those cases of molten metal separation from the metal surface due to metal cutting, weld pool splashing, entrainment and release of molten metal due to filler wire snap-out from the weld puddle, and molten metal accumulation and release from the end of the weld wire. Some possible ways of obtaining molten metal drop detachments would include an impulse force, or bump, to the weld sample, cut surface, or filler wire. Theoretical models were developed for these detachment concerns from principles of impact and kinetic energies, surface tension, drop geometry, surface energies, and particle dynamics. The surface tension represents the force opposing the liquid metal drop from detaching whereas the weight of the liquid metal droplet represents a force that is tending to detach the molten metal drop. Theoretical calculations have indicated that only a small amount of energy is required to detach a liquid metal drop; however, much of the energy of an impact is absorbed in the sample or weld plate before it reaches the metal drop on the cut edge or surface. The tendency for detachment is directly proportional to the weld pool radius and metal density and inversely proportional to the surface tension of the liquid metal. For a detachment the initial kinetic energy of the weld pool with respect to the plate has to exceed the energy to form the extra surface required for the detachment of the pool. The difficulty is in transferring the energy from the point of impact through the plate and sample to the cut edge. It is likely that not all of the kinetic energy is available for detaching the pool; some may be sequestered in weld pool oscillations. The coefficient of restitution for the collision will be lower than one if irreversible deformation, for example plastic flow deformation, takes place during the collision. Thus determining the amount of energy from an impact that actually reaches the molten metal droplet is critical. Various molten metal detachment scenarios were tested experimentally in an enclosed vacuum chamber using the Ukrainian Universal Hand Tool, an electron beam welder designed for space welding. The experimental testing was performed in a 4 ft. X 4 ft. vacuum chamber at Marshall Space Flight Center, evacuated to vacuum levels of at least 50 microTorr, and also some welding garment material was utilized to observe the effect of the molten metal detachments on the material. A "carillon" apparatus consisting of four pendulum hammer strikers, each weighing approximately 3.65 lbs, raised to predetermined specific heights was used to apply an impact force to the weld sample/plate during electron beam welding and cutting exercises. The strikers were released by switching on an electric motor to rotate a pin holding wires retaining the strikers at desired heights. The specimens were suspended so as to be free to respond to the blows with a sudden velocity increment. The specimens were mounted on a hinged plate for minimizing effective mass with the option to fasten it down so as to raise its effective mass closer to that anticipated for an actual space welding scenario. Measurements were made of the impact energy and the horizontal fling distances of the detached metal drops. It was not particularly easy to generate the detachments for this experiment. This document presents the details of the theoretical modeling effort and a summary of the experimental effort to measure molten metal drop detachments from terrestrial electron beam welding in the enclosed vacuum chamber. The results of the experimental effort have shown that molten metal detachments can occur from the sample/weld plate only if a sufficiently large impact force is applied to the weld plate. A "weld pool detachment parameter" was determined to indicate whether detachment would occur. Detachment can be either full or partial (dripping), Partial detachment means that the weld pool detached from one side of the liquid-solid boundary so as to leave a hole at the puddle site but remained attached over part of the liquid-solid boundary and dripped down the plate with no fully detached material detected. Full detachment, however, does not necessarily mean that the whole pool fully detached; in some cases only a smaller portion of the pool detached, the remainder dripping down the plate. The weld pool detachment parameter according to theory and according to the empirical data allows a determination of whether full detachments might occur. Theoretical calculations indicated titanium alloy would be the most difficult from which to detach molten metal droplets followed by stainless steel and then by aluminum. The experimental results were for the most part consistent with the theoretical analysis and predictions. The above theory is applicable to other situations as desired for assessing the potential for molten metal detachments.
We examined relative changes in soil C pools shortly after the establishment of six perennial and two annual bioenergy cropping systems that differed in diversity (monoculture vs. polyculture). Perennial systems included two monocultures (switchgrass, Panicum virgatum; and miscanthus, Miscanthus × giganteus) and four polycultures including hybrid poplar (Populus sp.) + herbaceous understory; mixed native grasses, successional vegetation, and restored prairie. Two annual systems included no-till continuous corn (Zea mays) and rotational corn (corn-soybean (Glycine max)-canola (Brassica napus)). Each crop was planted in a full factorial design at both a moderate fertility Alfisol and a high fertility Mollisol site. Relative differences in active, slow, and passive C pools in surface soils, where C changes are most likely to be detected early, were evaluated with 322-day laboratory incubations followed by acid hydrolysis to infer different pools from exponential decay curves. Five years post-establishment, active C pools under perennial polycultures at the Alfisol site were up to twice those under annual and perennial monocultures, and followed the order hybrid poplars (696 ± 216 μg C g− 1 soil, n = 5 replicate blocks) ≈ native grasses (656 ± 155) ≈ restored prairie (638 ± 44) > early successional (500 ± 54) ≫ continuous corn (237 ± 68) ≈ rotational corn (180 ± n.a.). Active C pools in perennial monocultures were similar to those in continuous corn: switchgrass (274 ± 29) ≈ miscanthus (299 ± 9). In contrast, differences in active C pools among crops at the more fertile Mollisol site were not detectable except for greater pools in the restored prairie and rotational corn systems. At both sites, slow and passive C pools differed little among systems except that slow pools were greater in the poplar system. That diversity rather than perenniality itself led to greater active C pools suggests that polycultures might be used to accelerate soil C accumulation in bioenergy and other perennial cropping systems.
Responses of tropical atmosphere to low-boundary forcing are investigated in a 2-D cumulus ensemble model (CEM) with an imposed warm-pool and cold-pool SST contrast (deltaSST). The domain-mean vertical motion is constrained to produce heat sink and moisture source as in the observed tropical climate. In a series of experiments, the warm pool SST is specified at different values while the cold pool SST is specified at 26 C. The strength of the circulation increases with increasing deltaSST until deltaSST reaches 3.5 C, and remains unchanged as deltaSST exceeds 3.5 C. The regulation of tropical convection by zonal SST gradient is constrained by the radiative cooling over the cold pool. For deltaSST less than 3.5 C, an enhanced subsidence warming is balanced by a reduced condensation heating over the cold pool. For deltaSST greater than 3.5 C, the subsidence regime expands over the entire cold pool where no condensation heating exist so that a further enhanced subsidence warming can no longer be sustained. The above regulation mechanism is also evident in the change of energy at the top of the atmosphere (TOA) that is dominated by cloud and water vapor greenhouse effect (c (sub LW)) and G (sub clear). The change in shortwave radiation at TOA is largely cancelled between the warm pool and cold pool, likely due to the same imposed vertical motion in our experiments. For deltaSST less than 3.5 C, an increase of deltaSST is associated with a large increase in c (sub Lw) due to increased total clouds in response to enhanced SST-induced circulation. For deltaSST greater than 3.5 C, clouds over the warm pool decrease with increasing SST, and the change in c (sub LW) is much smaller. In both dSST regimes, the change in CLW is larger than the change in G(sub clear) which is slightly negative. However, in the case of uniform warming (deltaSST=0), DeltaG(sub clear), is positive, approximately 5 W per square meters per degree change of SST.
Phosphorus (P) is an essential nutrient for sustaining life and agricultural production. Transformation of readily available P into forms that are unavailable to plants adds costs to P replenishment, which eventually translates into lower agronomic benefits and potential loss of soil P into runoff may degrade water quality. Therefore, understanding the sources and pathways of the formation of residual P pools in soils is useful information needed for the development of any technological or management efforts to minimize or inhibit the formation of such P pool and thus maximize availability to plants. In this research, we paired phosphate oxygen isotope ratios (δ 18 O P ) with solid-state 31 P NMR and quantitative XRD techniques along with general soil chemistry methods to identify the precipitation pathways of acid-extracted inorganic P (P i ) pools in an agricultural soil. Based on the comparison of isotope values of 0.5 mol L -1 NaOH-P i , 1 mol L -1 HCl-P i , and 10 mol L -1 HNO 3 -P i pools and correlations of associated elements (Ca, Fe, and Al) in these pools, the HNO 3 -P i pool appears most likely to be transformed from the NaOH-P i pool. A narrow range of isotope values of acid-P i pools in shallow (tilling depth) and below (where physical mixing is absent) is intriguing but likely suggests leaching of particle-bound P in deeper soils. Overall, these findings provide an improved understanding of the sources, transport, and transformation of acid-P i pools in agricultural soils and further insights into the buildup of legacy P in soils.
A 44-year record of water level fluctuations in a series of adjacent closed underground mines documents the history of closure and mine flooding in the Fairmont Coalfield, one of the oldest coal mining districts in the Pittsburgh coal basin, West Virginia, USA. As closures proceeded and mines began to flood, US environmental regulations were first enacted mandating mine water control and treatment, rendering uncontrolled surface discharges unacceptable. The purpose of this study is to present this flooding history and to identify critical events that determined how mine pools evolved in this case. Also examined is the strategy developed to control and treat water from these mines. Flooding is visualized using both water level hydrographs and mine flooding maps with the latter constructed assuming mine water hydraulic continuity between one or more mines. The earliest flooding formed small pools within near-surface mines closed prior to 1962 yet still pumped following closure to minimize leaking into adjacent still-active workings. These subpools gradually enlarged and merged as more closures occurred and the need for protective pumping was removed, forming what is today referred to as the unconfined Fairmont Pool. Later, deeper mines, separated by intact updip barriers from the Fairmont Pool, were closed and flooded more gradually, supplied in large part by leakage from the Fairmont Pool. By 1985, all mines except 2 had closed and by 1994 all had fully flooded, with the Fairmont Pool interconnected to deeper single mine pools via barrier leakage. As protective pumping ceased, the Fairmont Pool rose to a water level 3 m higher than surface drainage elevation and in 1997 discharged from an undermined section of Buffalo Creek near the Monongahela River. The principal mine operator in the basin then designed a pumping system to transfer water from the Fairmont Pool to their existing treatment facilities to the north, thus terminating the discharge. It may be concluded that the progress of mine flooding was influenced by mining history and design, by the timing of closures, by barrier leakage conditions, and by geologic structure. A key element in how flooding proceeded was the presence of a series of intact barriers separating deep from shallow mines. The shallow mines closed and flooded early, but then lost sufficient water by barrier leakage into the deeper mines to delay the completion of flooding until after the deep mines had all closed and flooded as well. Intensive mine water control has continued from the 1997 breakout to the present. The final water control scheme was likely unanticipated and serendipitous; future district-wide mining efforts should be advised to consider in advance closeout strategies to control mine water postmining.
Here, fuel assemblies in the spent fuel pool are stored by suspending them in two vertically stacked layers at the Atucha Unit 1 nuclear power plant (Atucha-I). This introduces the unique problem of verifying the presence of fuel in either layer without physically moving the fuel assemblies. Given that the facility uses both natural uranium and slightly enriched uranium at 0.85 wt% 235 U and has been in operation since 1974, a wide range of burnups and cooling times can exist in any given pool. A gross defect detection tool, the spent fuel neutron counter (SFNC), has been used at the site to verify the presence of fuel up to burnups of 8000 MWd/t. At higher discharge burnups, the existing signal processing software of the tool was found to fail due to nonlinearity of the source term with burnup.
The ultimate objective of basic studies of flow boiling in microgravity is to improve the understanding of the processes involved, as manifested by the ability to predict its behavior. This is not yet the case for boiling heat transfer even in earth gravity, despite the considerable research activity over the past 30 years. The elements that constitute the nucleate boiling process - nucleation, growth, motion, and collapse of the vapor bubbles (if the bulk liquid is subcooled) - are common to both pool and flow boiling. It is well known that the imposition of bulk liquid motion affects the vapor bubble behavior relative to pool boiling, but does not appear to significantly influence the heat transfer. Indeed, it has been recommended in the past that empirical correlations or experimental data of pool boiling be used for design purposes with forced convection nucleate boiling. It is anticipated that such will most certainly not be possible for boiling in microgravity, based on observations made with pool boiling in microgravity. In earth gravity buoyancy will act to remove the vapor bubbles from the vicinity of the heater surface regardless of how much the imposed bulk velocity is reduced, depending, of course, on the geometry of the system. Vapor bubbles have been observed to dramatically increase in size in pool boiling in microgravity, and the heat flux at which dryout took place was reduced considerably below what is generally termed the critical heat flux (CHF) in earth gravity, depending on the bulk liquid subcooling. However, at heat flux levels below dryout, the nucleate pool boiling process was enhanced considerably over that in earth gravity, in spite of the large vapor bubbles formed in microgravity and perhaps as a consequence. These large vapor bubbles tended to remain in the vicinity of the heater surface, and the enhanced heat transfer appeared to be associated with the presence of what variously has been referred to as a liquid microlayer between the bubble and the heater surface. The enhancement of the boiling process with low velocities in earth gravity for those orientations producing the formation of a liquid macrolayer described above, accompanied by "sliding" vapor bubbles, has been demonstrated. The enhancement was presented as a function of orientation, subcooling, and heated length, while a criterion for the heat transfer for mixed natural/forced convection nucleate boiling was given previously. A major unknown in the prediction and application of flow boiling heat transfer in microgravity is the upper limit of the heat flux for the onset of dryout (or critical heat flux - CHF), for given conditions of fluid-heater surfaces, including geometry, system pressure and bulk liquid subcooling. It is clearly understood that the behavior in microgravity will be no different than on earth with sufficiently high flow velocities, and would require no space experimentation. However, the boundary at which this takes place is still an unknown. Previous results of CHF measurements were presented for low velocity flow boiling at various orientations in earth gravity as a function of flow velocity and bulk liquid subcooling, along with preliminary measurements of bubble residence times on a flat heater surface. This showed promise as a parameter to be used in modeling the CHF, both in earth gravity and in microgravity. The objective of the work here is to draw attention to and show results of current modeling efforts for the CHF, with low velocities in earth gravity at different orientations and subcoolings. Many geometrical possibilities for a heater surface exist in flowing boiling, with boiling on the inner and outer surfaces of tubes perhaps being the most common. If the vapor bubble residence time on and departure size from the heater surface bear a relationship to the CHF, as results to be given indicate, it is important that visualization of and access to vapor bubble growth be conveniently available for research purposes. In addition, it is desirable to reduce the number of variables as much as possible in a fundamental study. These considerations dictated the use of a flat heater surface, which is rectangular in shape, 1.91 cm by 3.81 cm (0.75 x 1.5 inches), consisting either of a 400 Angstrom thick semi-transparent gold film sputtered on a quartz substrate which serves simultaneously as a heater and a resistance thermometer, or a copper substrate of the same size. The heater substrate is a disc which can be rotated so that the heated length in the flow direction can be changed from 1.91 to 3.81 cm (0.75 to 1.5 inches). The fluid is R-113, and the velocities can be varied between 0.5 cm/s and 60 cm/s. For a sufficiently low velocity the CHF can be modeled reasonably well at various orientations by the correlation for pool boiling corrected for the influence of bulk liquid subcooling, multiplied by the square root of q, the angle relative to horizontal. This arises from equating buoyancy and drag forces in the inverted positions where the vapor bubbles are held against the heater surface as they slide. A distortion of the measurements relative to pool boiling occurs as the flow velocity increases. In modeling this effect at different levels of subcooling it appeared appropriate to estimate the volumetric rate of vapor generation, using measurements of bubble frequency (or residence time), void fraction and average bubble boundary layer thickness. These were determined with the use of a platinum hot wire probe 0.025 mm in diameter by 1.3 mm long, applying a constant current to distinguish between contact with liquid or vapor. Two-dimensional spatial variations are obtained with a special mechanism to resolve displacements in increments of 0.025 mm. From such measurements it was determined that the fraction of the surface heat transfer resulting in evaporation varies inversely with the subcooling correction factor for the CHF. The measured inverse bubble residence time is normalized relative to that predicted for an infinite horizontal flat plate at the CHF, and is correlated well with the CHF normalized relative to that for pool boiling, for various orientation angles and subcooling levels. This correspondence is then combined with a normalizing factor for the energy flux leaving the heater surface at the CHF and the computed bubble radius at departure, determined from the balance between the outward velocity of the interface due to evaporation and the buoyance induced velocity of the center of mass of the bubble. The product of the CHF and the corresponding residence time was determined to be a constant for all orientations at a given bulk flow velocity and liquid subcooling, and must be determined empirically for each velocity and subcooling at present. It then becomes possible to predict the CHF for the different orientations, velocities, and subcoolings. These are compared with normalized measurements of the CHF for velocities ranging from 4 cm/s to 55 cm/s, subcoolings from 2.8 to 22.2 K, over orientations angles of 360 degrees.
The theory of Rotunno et al. (“RKW” theory) addresses the behavior of squall-line cold pools in vertically sheared flows. It predicts that, within a given thermodynamic environment, a balance between baroclinic vorticity generation by the cold pool and low-level environmental vertical wind shear induces an upright updraft along the gust front that maximizes the initiation of new convective cells. Although this theory has been evaluated numerically, its applicability to observed systems remains unclear and is limited by a lack of critical measurements, including high-frequency thermodynamic and wind profiles across the gust front. Herein, observations from the Atmospheric Radiation Measurement Southern Great Plains (ARM-SGP) observatory near Lamont, Oklahoma, are used to evaluate RKW theory for 10 well-observed squall lines over a 11-yr period. For this evaluation, RKW parameters including cold-pool intensity (c), low-level ambient, line-normal vertical shear (ΔV n ), subcloud and cloud-layer updraft tilts, and multiple measures of system intensity are estimated. Furthermore, the c estimates rely on thermodynamic retrievals from the Atmosphere Emitted Radiance Interferometer (AERI), which are uncertain but verify reasonably well against independent observations. As predicted by the theory, for c/ΔV n ≥ 1, c/ΔV n correlates positively with updraft tilt and negatively with system intensity, but these results are not always statistically significant and are also sensitive to the method by which ΔV n is evaluated. Specifically, ΔV n evaluations that extend above the cold-pool top yield greater consistency with RKW predictions. Also, some measures of intensity correlate more strongly with standard moist instability metrics than with RKW parameters.