Search NASA⌕ Search

SEARCH · Search NASA

Results for “probing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Evaluation of a wall-flow direction probe for measurements in separated flows

The upstream-downstream flow direction intermittency is an important parameter that can quantitatively describe the stages of flow separation. This paper gives an improved design for a wall-flow-direction probe. Intermittency measurements made using this modified probe show agreement within experimental uncertainties with direct measurements made using a LDV, although both the unmodified and modified probe designs produce results that are consistently higher than those for the LDV.

Shivaprasad, B. G.↗

Spallation of the Galileo probe heat shield

The Galileo probe heat shield will encounter severe radiative and convective heating during entry into Jupiter's atmosphere. The shield is made of two different carbon phenolic composites; one is chopped-molded, and the other is tape-wrapped, both of which tend to spall under intense heating conditions. To characterize this phenomenon, an experimental program, using a gasdynamic laser, was initiated. Tests were performed at a variety of radiation intensities, and both the total and spallation mass-loss rates were measured and correlated with intensity. These correlations were then applied to calculated flight heating conditions for two model atmospheres. Entry of a 310-kg probe into the nominal atmosphere would result in a spallation mass loss of 6.3 kg, or 7.4% of the expected thermochemical mass loss. Similarly, entry of that probe into the cool-dense atmosphere would result in 11.9 kg of spallation, or about 10% of the expected thermochemical mass loss.

Lundell, J. H.↗

Advancements in aerothermodynamics in support of the Galileo probe

The Galileo probe, scheduled for launch in 1985, will experience the most severe heating environment ever encountered for a planetary mission, and the probe design should be based on a reliable definition of the aerothermal environment during entry. Significant advances in numerical computations make possible the prediction of such complicated flowfields, which include the effects of massive ablation injection, radiative transfer, turbulence, shape change and small angle of attack. Also included is a discussion of modeling and data inputs for numerical computations as deduced from both experimental and analytical studies concerning: radiation, transport and thermodynamic properties; probe afterbody flowfield and heating conditions; and the role of ablator spallation.

Moss, J. N.↗

Comparison of spherical double probe electric field measurements with plasma bulk flows in plasmas having densities less than 1 cm-3

For a three-hour period in the magnetotail over which plasma density varied from less than 0.1 to about 1/cu cm, comparisons of ISEE-1 spherical double probe (dawn to dusk) electric field measurements and ISEE-2 plasma flows (converted to electric fields) show the zero lag cross correlation coefficient between 768 second averages of the two data sets to have been 0.93. A statistical relative uncertainty between pairs of points in the two data sets, estimated by only including counting statistics in the plasma measurement and time variations of the observed electric field over the measurement interval, is able to account for at least 75 percent of the deviations between the two data sets. In agreement with simple Langmuir probe theory, it has been found that the spacecraft potential measured over the three-hour interval by the double probe instrument varied as the log of the product of the plasma density and the square root of the electron temperature.

Mozer, F. S.↗

Probe Follower for Moving Blood Vessels

Probes track vessel expansion and contraction with minimal perturbation. Nozzle back-pressure changes at cuff on blood vessel basis for monitoring position of probe in blood vessel. Fluidic amplifiers use signals to control three-axis servo that centers measuring probe between sensing-nozzle pairs at cuff.

Frazer, R. E.↗

The Galileo probe Li/SO2 battery

NASA's Galileo mission to Jupiter will consist of an orbiter and a probe, the probe to descend through and analyze the Jovian atmosphere. All power for the probe will be supplied by three battery modules containing a total of 39 D size Li/SO2 cells that will be required to retain capacity for the duration of the mission (over 50 months) and then provide current at 3 to 4 amperes for 48 minutes. The design, development, and testing of this battery are described herein.

Marcoux, L.↗

The Harp probe - An in situ Bragg scattering sensor

A wave sensor, consisting of parallel, evenly spaced capacitance wires, whose output is the sum of the water surface deflections at the wires, has been built and tested in a wave tank. The probe output simulates Bragg scattering of electromagnetic waves from a water surface with waves; it can be used to simulate electromagnetic probing of the sea surface by radar. The study establishes that the wave probe, called the 'Harp' for short, will simulate Bragg scattering and that it can also be used to study nonlinear wave processes.

Mollo-Christensen, E.↗

Error analyses for the delivery of a spinning probe to Jupiter

The task of delivering the Galileo Probe to specified atmospheric entry conditions at Jupiter is especially challenging because tracking, trajectory corrections, and attitude adjustments are not possible after release of the Probe from the carrier vehicle. Statistical analysis of the spacecraft dynamics mapped into Probe dispersions in atmosphere-relative and relay-geometry parameters show that attitude stability, heating, and relay performance requirements can be satisfied. Reconstruction techniques are used to enhance estimates of the delivery parameters to permit correct interpretation of the scientific data for the Jovian atmosphere. A tradeoff which sacrifices some delivery accuracy and propellant is shown to guarantee satisfaction of a very tight reconstruction requirement for the trajectory considered in this report.

Hintz, G. R.↗

Planning a probing voyage to Jupiter

Encompassing both an orbiter and an atmospheric probe, Project Galileo will study in detail the phenomena of the plant Jupiter together with those of its moons and its dynamic magnetospheric environment. The probe element will sample the temperature and pressure structure of the Jupiter atmosphere, analyzing the composition of its gases, locating the various cloud decks, measuring radiation balances, and searching for evidence of lightning strikes. Galileo is the first planetary exploration mission to be launched by means of the Space Shuttle. Virtually all Galileo subsystems are fully reprogrammable from the earth to allow mission alterations as new data are obtained. A major technical challenge, however, was posed by probe-to-orbiter communications through the dense Jovian atmosphere.

Draper, R. F.↗

Picosecond excite-and-probe absorption measurement of the 4T2 state nonradiative lifetime in ruby

In a picosecond excite-and-probe absorption measurement, a 527-nm picosecond pulse excites the 4T2 state of the Cr(3+) ion in ruby and a 3.4-micron picosecond probe pulse monitors the growth and decay of population in the 2E state as a function of pump-probe delay. From the growth of population in the metastable 2E state, an upper limit of 7 ps for the nonradiative lifetime of the 4T2 state is determined.

Gayen, S. K.↗

Study of new systems concepts for a Titan atmospheric probe

Results of a systems concepts study for a Titan Probe were examined. The key tradeoffs performed are described in detail. Mass breakdown of each Probe subsystem or major element were given. The mission analysis performed to determine compliance with the high altitude sampling and descent time requirements are described. The baseline Descent Module design was derived. The element of the Probe System left on the Carrier after separation were described.

Bernard, Doug↗

Techniques for using emitting probes for potential measurement in RF plasmas

Investigations of the effects of RF on plasma potential measurements with electron emitting probes and methods for interpreting data are presented. Techniques correspond to the floating and inflection point methods of single-emitting and differential emitting probes, respectively. A simple method of measurement of plasma potential fluctuations is given which makes use of time-averaged emitting probe I-V characteristics.

Wang, E. Y.↗

Vortex Suppressors Reduce Probe Vibrations

Lightweight addition to probe reduces cyclical stress aerodynamically. Life expectancy of instrumentation probe for high-speed flow increased by addition of helical strakes to cylindrical shield surrounding probe. Strakes disrupt vortex shedding normally occuring in fast flows around cylindrical body.

Hill, Arthur J.↗

The calibration and operation of a constant-temperature crossed-wire probe in supersonic flow

The calibration and operation of a constant-temperature crossed-wire probe in supersonic flow is considered. Crossed-wire probes offer considerable advantages over single, inclined wires: the kinematic shear stress can be derived from a single point measurement; the rms quantities can be derived from the same measurement, and the instantaneous quantities can be obtained as a continuous function of time. However, using a crossed-wire probe in supersonic flow is subject to the following practical difficulties: the problem of flow interference, where the shock waves from one wire and its supports interfere with the flow over the other wire; the necessity for high frequency response to resolve the spectral content, and the sensitivity of the results to small changes in the calibration constants. In the present contribution, each of these problems is addressed. Practical solutions are suggested, and some encouraging results are presented.

Fernando, E. M.↗

Subminiature Hot-Wire Probes

Class of improved subminiature hot-wire flow-measuring probes developed. Smaller sizes yield improved resolution in measurements of practical aerodynamic flows. Probe made in one-wire, two-perpendicular-wire, and three-perpendicular-wire version for measurement of one, two, or all three components of flow. Oriented and positioned on micromanipulator stage and viewed under microscope during fabrication. Tested by taking measurements in constant-pressure turbulent boundary layer. New probes give improved measurements of turbulence quantities near surfaces and anisotropies of flows strongly influence relative errors caused by phenomena related to spatial resolution.

Westphal, R. V.↗

Theoretical derivation and calibration technique of a hemispherical-tipped, five-hole probe

A technique is presented for the calibration of a hemispherical tipped 0.125 inch diameter 5-hole probe. The derivation of equations from the potential flow over a sphere relating the flow angle and velocity to pressure differentials measured by the probe is presented. The technique for acquiring the calibration data and the technique used to calculate the calibration coefficients are presented. The accuracy of the probe in both the uniform calibration flow field and the nonuniform flow field over a 75 degree swept delta wing is discussed.

Kjelgaard, Scott O.↗

Project Longshot: An unmanned probe to Alpha Centauri

A preliminary design is presented for an unmanned probe to Alpha Centauri with a planned launch early in the 21st century. The probe would be assembled at the space station and take approx. 100 yrs to reach the nearest star. Several technologies must be developed in order for this mission to be possible. A pulsed fusion microexplosion drive with 1,000,000 secs of specific impulse is the primary enabling technology. A large, long life fission reactor with 300 kW power output is also required. Communications lasers would use a 0.532 micrometer wavelength since there is minimal power output by the stars in that frequency band. A laser with an input power of 250 kW would allow for a data rate of 1000 bits per second at maximum range. There are 3 types of information to be gathered by the probe: properties of the interstellar medium, characteristics of the three star Alpha Centauri system, and astrometry.

Beals, Keith A.↗

The use of dc-probe measurements in the middle atmosphere program

The middle atmosphere is weakly ionized, collision dominated plasma. Rocket-borne dc probes have proven effective in measuring conductivity and electron and ion concentrations in this plasma, and in some cases electron temperatures and ion composition were observed. During MAP, dc probes were also used successfully to study turbulence in the middle atmosphere, using the plasma as a passive tracer for the dynamical processes in the nonionized gas. Basic principles are reviewed of the dc-probe technique and examples are presented of results obtained during MAP.

Thrane, E. V.↗