Search NASA⌕ Search

SEARCH · Search NASA

Results for “pump efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Parallel parametric amplification of coherently excited propagating spin waves in a microscopic Ni{sub 81}Fe{sub 19} waveguide

We present parallel parametric amplification of coherently excited, propagating spin waves in a microstructured magnonic Ni{sub 81}Fe{sub 19} waveguide. Amplification is achieved by the pumping field generated by a microwave current flowing through a Cu micro-stripline underneath the waveguide. By employing microfocussed Brillouin light scattering spectroscopy, we investigate the spatial decay of the propagating spin waves and their amplification by means of parallel pumping. We analyze the dependence of the intensity of the amplified spin waves on the spin-wave excitation power, pumping power, and pumping duration, revealing the most efficient working point for a noise-free amplification. This paves the way for a frequency selective amplification of spin waves in microstructured magnonic circuits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Predictable third harmonic generation in GaAs metasurfaces through group theory inverse design of meta-atoms

Here we report the group theory-based inverse design of meta-atoms for a dielectric metasurface in GaAs with predictable optical linear response and third harmonic generation (THG). Six sharp Fano resonances have been observed with a corresponding polarization dependence as predicted by group theory and the meta-atom’s symmetry in the D2h point group. THG has been observed for two modes under x-polarization excitation and one mode for y-polarization, in agreement with theoretical symmetry predictions. The polarization-dependent THG aspect ratio was observed to reach as high as 108. Through strategic structural or symmetry-preserving perturbations, it was shown that the THG can be enhanced or reduced by a factor of 7. The highest THG conversion efficiency was estimated to be 3.1×10-7 at the pump intensity of 1.51 MW/cm2. This high THG conversion efficiency indicates that our group theory approach to modal engineering opens a new path towards optical nonlinearity tuning in dielectric metasurfaces.

Aoueille, Andrew↗

The effects of outdoor air-side fouling on frost growth and heat transfer characteristics of a microchannel heat exchanger: An experimental study

Air source heat pumps have the potential to efficiently heat and cool buildings, but their effectiveness in many climates is limited by frost growth on the outdoor heat exchanger in heating mode. These heat exchanger coils are also subject to fouling from fibers and particulates outdoors. Frost and fouling have each independently been studied extensively, and newly available research on fouling provides a method to realistically foul the air-side of coils in the laboratory. The current paper uses this method to conduct the first laboratory study of the important interactions between fouling and frost growth for a heat pump outdoor coil. A microchannel heat exchanger is tested clean and fouled, with variations in fouling level, humidity, and initial face velocity of air. Air flow rate is allowed to vary with resistance, and a surprising result is that light fouling increases heat transfer and frost growth rates, even with a 3.5% reduction in initial airflow caused by the fouling. However, heavier fouling decreases both rates. When frost growth is normalized to heat transfer, it is found to be increased by fouling; i.e. the coil’s sensible heat ratio decreases.

42 ENGINEERING↗

Terahertz lasers based on intracentre transitions of group V donors in uniaxially deformed silicon

This paper presents a brief overview of available experimental data on the characteristics of stimulated terahertz emission (4.9 – 6.4 THz) from optically excited neutral group V donors (phosphorus, antimony, arsenic and bismuth) in crystalline silicon subjected to uniaxially compressive strain along the [100] axis. Strain is shown to have a significant effect on the characteristics in question. Optimal strain depends on the dopant and may reduce the threshold pump intensity and improve lasing efficiency. We discuss possible mechanisms behind this effect and estimate the limiting output emission parameters. (terahertz radiation)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MODELING AND OPTIMIZATION STUDY OF A TIGHTLY INTEGRATED ROTARY ELECTRIC MOTOR-HYDRAULIC PUMP

To meet the growing trend of electrification of mechanical systems, this paper presents a compactly integrated electric motor and hydraulic pump. The proposed application for this machine requires high flow rates at low pressure differentials and four quadrant operation. The hydraulic pump architecture selected for this machine is a radial ball piston pump. An inside impinged version of this architecture allows for efficient filling of the chambers and is radial balanced, both of which allow high- speed operation for increased power density. The radial ball piston pump is less expensive to manufacture and is radially more compact than a standard radial cylindrical piston pump. A model of the pump and the integrated electric motor have been created to study scaling relationships and drive detailed design and optimization. The scaling study considers how displacement is affected by pump diameter, and how the diameter and required torque change with angular velocity. The detailed model considers the effect of valve timing, piston-cylinder clearance, and pump geometry on the efficiency. The model is then exercised in an optimization of the machine parameters.

30 DIRECT ENERGY CONVERSION↗

Observation of spin-charge conversion in chemical-vapor-deposition-grown single-layer graphene

Conversion of pure spin current to charge current in single-layer graphene (SLG) is investigated by using spin pumping. Large-area SLG grown by chemical vapor deposition is used for the conversion. Efficient spin accumulation in SLG by spin pumping enables observing an electromotive force produced by the inverse spin Hall effect (ISHE) of SLG. The spin Hall angle of SLG is estimated to be 6.1 × 10{sup −7}. The observed ISHE in SLG is ascribed to its non-negligible spin-orbit interaction in SLG.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Feasibility Study: Ductless Hydronic Distribution Systems with Fan Coil Delivery

Hydronic distribution systems have a long history, and are widely used in commercial buildings. As with mini-split heat pumps, hydronic systems using small terminal fan coils have the potential to provide high-quality comfort to homes that have small heating and cooling loads, but at a lower cost and with greater flexibility. These “ductless hydronic” distribution systems eliminate space requirements needed for ducting, eliminate duct thermal losses, and are easy to zone. Since heat pump chiller-heaters can be charged with refrigerant at the factory, hydronic systems also avoid refrigerant system faults such as incorrect charge and inadequate evacuation of lines that can lead to sub-standard performance. Other advantages include: reduction in the amount of energy required to deliver heating and cooling, reduced equipment cycling, and the potential for incorporating energy storage for peak load avoidance and demand response. Ductless hydronic systems are best suited for new homes, but with the relative ease of installing piping in attic spaces (for example under attic insulation), they are also suitable for existing homes that have old, leaky, and poorly insulated ducts. With a broader and more affordable product offering from manufacturers, installation guidelines, and contractor training, this method of distribution has significant potential to meet the space conditioning needs of high performance homes. The primary objectives of this study are to estimate potential energy savings relative to conventional ducted air distribution, and to identify equipment requirements, costs, and barriers. The analysis focuses on ductless hydronic delivery systems that use water-to-air terminal units in each zone. This system type is applicable in all climate regions and can provide sensible and latent cooling and/or heating using a single hot and chilled water source such as a heat pump, or a separate water heater and chiller. Results of TRNSYS modeling indicate that annual heating and cooling energy use (site and source) can be reduced by up to 22% when substituting pipes, pump, small distributed fan coils, and a water-to-air heat pump for the ducts, air handler, indoor coil, and conventional air-to-air heat pump unit of similar rating as the air-to-water unit. Of the 22% savings, on average 36% is attributable to the lower energy required by pumps and small fans vs. air handler blowers, and 64% to the reduced losses from pipes as compared to ducts. Using the modeled energy savings and estimated costs, hydronic distribution appears to be economically viable in three of the four climates evaluated. Other current field studies of air-to-water heat pumps coupled to radiant floor systems are demonstrating heat pump performance that exceeds seasonal performance calculated using a standard heat pump performance map (German, 2011a, German, 2011b). Hydronic distribution systems can meet sensible and latent cooling needs in all climates. Major barriers to widespread application include the lack of low-cost, small, ceiling-mounted fan coils, and the limited availability and higher cost of air-to-water heat pumps. The latter could be overcome by the production of an add-on refrigerant-to-water conversion kit that could be used to adapt any heat pump to serve as a water chiller-heater. Development of accurate performance maps and additional data on field performance are areas that should be targeted by future research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy dataset of Frontier supercomputer for waste heat recovery

The Hewlett Packard Enterprise–Cray EX Frontier is the world’s first and fastest exascale supercomputer, hosted at the Oak Ridge Leadership Computing Facility in Tennessee, United States. Frontier is a significant electricity consumer, drawing 8–30 MW; this massive energy demand produces significant waste heat, requiring extensive cooling measures. Although harnessing this waste heat for campus heating is a sustainability goal at Oak Ridge National Laboratory (ORNL), the 30 °C–38 °C waste heat temperature poses compatibility issues with standard HVAC systems. Heat pump systems, prevalent in residential settings and some industries, can efficiently upgrade low-quality heat to usable energy for buildings. Thus, heat pump technology powered by renewable electricity offers an efficient, cost-effective solution for substantial waste heat recovery. However, a major challenge is the absence of benchmark data on high-performance computing (HPC) heat generation and waste heat profiles. This paper reports power demand and waste heat measurements from an ORNL HPC data centre, aiming to guide future research on optimizing waste heat recovery in large-scale data centres, especially those of HPC calibre.

97 MATHEMATICS AND COMPUTING↗

Pump Flow Analysis

Ingersoll-Rand Research, Inc.'s use of COSMIC's computer program MERIDL permits designers to evaluate performance and efficiency characteristics to be expected from the pump's impeller. It also provides information that enables a trained hydraulic engineer to make design improvements. Company was able to avoid the cost of developing new software and to improve some product design features.

Source record↗

Modeling and Simulation of Air-Source CO2 Heat Pump Water Heater

Carbon dioxide (CO2) has been widely used as working fluid for the vapor-compression refrigeration systems in large marine device. Due to the potential energy efficiency and the favorable environmental properties of CO2 as a working fluid, CO2 heat pump water heater (HPWH) systems are regarded a promising technology for centralized domestic hot water (DHW) heating in residential and commercial buildings. However, there is still at the early stage of appropriately optimizing and improving the energy performance of CO2 HPWH. This requires CO2 HPWH simulation tools capable of capturing the accurate impact of the emerging compressor, throttle device, and heat exchanger technology on CO2 heat transfer and energy efficiency. In this study, high efficiency components (compressors, pumps, fans, heat exchangers) were identified and applied to the state-of-art CO2 HPWH designs and analyzed their performance by using numerical simulation. This was done by simulating the performance of CO2 HPWH using ACMODEL design model combined with the component models developed at Oak Ridge National Laboratory (ORNL) for orifice tube, map-based compressor, and tube-in-tube gas cooler. ACMODEL is an equipment design model for CO2-based air conditioners and heat pumps developed by Purdue University to account for the details of each component. The simulated CO2 HPWH performance was then compared with the heat pump water heater using conventional refrigerants.

Gao, Zhiming↗

Model Investigation of Temperature and Concentration Dependent Luminescence of Erbium-doped Tellurite Glasses

Improving the up-conversion efficiency is the key issue in tellurite glasses. The quantum efficiency, radiative transition rate and lifetimes of excited states are greatly influenced by the optical properties of the host material, ligand field, multiphonon relaxation processes, impurities, temperature and concentration of erbium ions. We develop a comprehensive 4-level model to examine the radiative and nonradiative (NR) decay processes for the green ({sup 4}S{sub 3/2}{yields}{sup 4}I{sub 15/2}) and red ({sup 4}F{sub 9/2}{yields}{sup 4}I{sub 15/2}) emission over a temperature range of (10-340 K) and concentration range of (0.1-4.5 mol.%). Concentration dependent enhancement and thermal quenching of efficiency for up-conversion is investigated using the derived rate equations. These features are attributed to the NR energy transfer processes, trapped impurity effects, and thermal assisted hopping. The unusual nature of temperature and concentration dependent quenching effects for green and red emission is queries for further investigations. It is further suggested that to achieve higher infrared to visible up-converted efficiency in tellurite glasses the NR channels for energy and charge transfer by phonon and impurity mediated process has to be minimized. Our results on pump power dependent emission intensity, quantum efficiency, luminescence intensity, radiative lifetimes, and transition probabilities are in conformity with other experimental findings.

74 ATOMIC AND MOLECULAR PHYSICS↗

Injection-seeded operation of a Q-switched Cr,Tm,Ho:YAG laser

Single-frequency Tm,Ho:YAG lasers operating near 2 microns are attractive sources for several applications including eye-safe laser radar (lidar) and pumping of AgGaSe2 parametric oscillators for efficient generation of longer wavelengths. As part of a program to develop a coherent lidar system using Tm,Ho:YAG lasers, a diode laser-pumped tunable CW single-longitudinal-mode (SLM) Cr:Tm:Ho:YAG laser and a flashlamp-pumped single-transverse-mode Q-switched Cr,Tm,Ho:YAG laser were developed. The CW laser was used to injection-seed the flashlamp-pumped laser, resulting in SLM Q-switched output. Operational characteristics of the CW and Q-switched lasers and injection-seeding results are reported.

Henderson, Sammy W.↗

Model-Based Investigation of Multi-Fault Interactions and Performance Degradation in Residential Heat Pump Systems

Faults in heat pump systems can significantly degrade performance, reduce efficiency, and accelerate component wear, leading to higher operating costs and maintenance demands. While numerous studies have investigated the impact of individual faults, the interactions between multiple concurrent faults remain insufficiently understood, despite their common occurrence in real-world operation. This study conducts a comprehensive simulation analysis of multiple simultaneous faults in a vapor compression heat pump using a validated heat pump design model (HPDM) tool. Detailed component-level modeling methods are implemented to examine performance sensitivity under combinations of refrigerant flow and heat exchanger faults. The results reveal complex fault interactions that can mask or amplify system deviations, challenging conventional diagnostic approaches. Findings from this work provide meaningful insights for the development of more robust fault detection and diagnosis algorithms, supporting improved reliability and energy efficiency in next-generation heat pump technologies.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Ultralow-threshold thin-film lithium niobate optical parametric oscillator

Materials with strong second-order ( χ <#comment/> ( 2 ) ) optical nonlinearity, especially lithium niobate, play a critical role in building optical parametric oscillators (OPOs). However, chip-scale integration of low-loss χ <#comment/> ( 2 ) materials remains challenging and limits the threshold power of on-chip χ <#comment/> ( 2 ) OPO. Here we report an on-chip lithium niobate optical parametric oscillator at the telecom wavelengths using a quasi-phase-matched, high-quality microring resonator, whose threshold power ( ∼ <#comment/> 30 µ <#comment/> W ) is 400 times lower than that in previous χ <#comment/> ( 2 ) integrated photonics platforms. An on-chip power conversion efficiency of 11% is obtained from pump to signal and idler fields at a pump power of 93 µW. The OPO wavelength tuning is achieved by varying the pump frequency and chip temperature. With the lowest power threshold among all on-chip OPOs demonstrated so far, as well as advantages including high conversion efficiency, flexibility in quasi-phase-matching, and device scalability, the thin-film lithium niobate OPO opens new opportunities for chip-based tunable classical and quantum light sources and provides a potential platform for realizing photonic neural networks.

Lu, Juanjuan (ORCID:0000000319389119)↗

Design Heating and Cooling Load Calculation Versus Building Load Simulation for Cold Climate Heat Pumps: Understanding the "Gap"

This report explores the differences between Manual J-equivalent block load calculations and building HVAC energy simulation results using EnergyPlus™ calculations when designing cold climate heat pump systems for residential use. This study will help HVAC researchers and advanced designers understand the impacts of oversizing heat pumps on home energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-Gain-Length, Solar-Pumped Box Laser

New laser cavity configuration efficiently couples solar radiation to laser mode volume. Lasing output powers of approximately 300 mW achieved for durations of 150 ms. New system allows lasing at substantially lower solar simulator intensities (150 Suns) and much longer laser gain lengths (60 cm).

De Young, R. J.↗

Study of a helium laser pumped by a pulsed electron beam generated in an open discharge

A laser on the self-contained helium 2{sup 1}P{sub 1}{sup 0} - 2{sup 1}S{sub 0} transition pumped by a pulsed electron beam generated in an open discharge is simulated and experimentally studied. Lasing without decreasing the pulse energy in a tube of diameter 31 mm was observed up to the pump pulse repetition rate of 10 kHz determined by the parameters of a power supply. Dynamics of the electric field in an accelerating gap and populations of the working levels of helium are calculated. The radiation power calculated in accordance with its radial distribution measured in the saturated amplification regime is 7.85 times higher than that in the lasing regime. The practical laser efficiency of 0.056% is achieved for the quantum efficiency of 0.7%. (active media. lasers)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗