Search NASA⌕ Search

SEARCH · Search NASA

Results for “quality monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Viking 1975 Mars lander interactive computerized video stereophotogrammetry

A novel computerized interactive video stereophotogrammetry system has been developed for analysis of Viking 1975 lander imaging data. Prompt, accurate, and versatile performance is achieved. Earth-returned digital imagery data are driven from a computer to a pair of video monitors. Powerful computer support enables a photogrammetrist, stereoscopically viewing the video displays, to create diverse topographic products. Profiles, representing the intersection of any definable surface with the Martian relief, are readily generated. Vertical profiles and elevation contour maps, including stereo versions, are produced. Computer overlays of map products on stereo images aid map interpretation and permit independent quality evaluation. Slaved monitors enable parallel viewing. Maps span from the immediate foreground to the remote limits of ranging capability. Surface sampler arm specific vertical profiles enable direct reading of arm commands required for sample acquisition, rock rolling, and trenching. The ranging accuracy of plus or minus 2 cm throughout the sample area degrades to plus or minus 20 m at 100-m range.

Liebes, S., Jr.↗

Aerosol sources in subway environments

Highlights: • PM{sub 2.5} concentrations varied widely among subway platforms (26–86 µg m{sup −3}). • Main PM{sub 2.5} component in metro microenvironment is iron oxide. • Subway sources contribution account for up to 91% of ambient subway PM{sub 2.5}. • From the five subway-specific sources identified, brakes contributed the most. • Elements related with health issues are apportioned mostly by subway sources (> 60%). Millions of people use rail subway public transport around the world, despite the relatively high particulate matter (PM) concentrations in these underground environments, requiring the identification and quantification of the aerosol source contributions to improve the air quality. An extensive aerosol monitoring campaign was carried out in eleven subway stations in the Barcelona metro system, belonging to seven subway lines. PM{sub 2.5} samples were collected during the metro operating hours and chemically analysed to determine major and trace elements, inorganic ions, and total carbon. The chemical compositions of subway components such as brake pads, rail tracks and pantographs were also determined. The mean PM{sub 2.5} concentrations varied widely among stations, ranging from 26 µg m{sup −3} to 86 µg m{sup −3}. Subway PM{sub 2.5} was mainly constituted by Fe{sub 2}O{sub 3} (30–66%), followed by carbonaceous matter (18–37%) for the old stations, while for new stations equipped with Platform Screen Doors (PSD) these percentages go down to 21–44% and 15–30%, respectively. Both the absolute concentrations and the relative abundance of key species differed for each subway station, although with common patterns within a given subway line. This is a result of the different emission chemical profiles in different subway lines (using diverse types of brakes and/or pantographs). The co-emission of different sources poses a problem for their separation by receptor models. Nevertheless, receptor modelling (Positive Matrix Factorization) was applied resulting in ten sources, five of them subway-specific: RailWheel, RailWheel+Brake, Brake{sub A}, Brake{sub B}, Pb. The sum of their contributions accounted for 43–91% of bulk PM{sub 2.5} for the old stations and 21–52% for the stations with PSD. The decrease of the activity during the weekends resulted in a decrease (up to 56%) in the subway-specific sources contribution to the –already lower– bulk PM{sub 2.5} concentrations compared to weekdays. The health-related elements are mainly apportioned (> 60%) by subway sources.

54 ENVIRONMENTAL SCIENCES↗

Long-Term Statistical Process Monitoring of an Ultrafiltration Water Treatment Process

As water treatment technology has improved, the amount of available process data has substantially increased, making real-time, data-driven fault detection a reality. One shortcoming of the fault detection literature is that methods are usually evaluated by comparing their performance on hand-picked, short-term case studies, which yields no insight into long-term performance. In this work, we first evaluate multiple statistical and machine learning approaches for detrending process data. Then, we evaluate the performance of a PCA-based fault detection approach, applied to the detrended data, to monitor influent water quality, filtrate quality, and membrane fouling of an ultrafiltration membrane system for indirect potable reuse. Based on two short case studies, the adaptive lasso detrending method is selected, and the performance of the multivariate approach is evaluated over more than a year. The method is tested for different sets of three critical tuning parameters, and we find that for long-term, autonomous monitoring to be successful, these parameters should be carefully evaluated. However, in comparison with industry standards of simpler, univariate monitoring or daily pressure decay tests, multivariate monitoring produces substantial benefits in long-term testing.

ammonia↗

Continuous Water Quality Sensing for FGD Wastewater

The coal fired plant power industry requires new solutions for on-line monitoring of flue gas desulfurization (FGD) wastewaters for regulated trace metals to reduce recurring operating and off-site laboratory analysis costs and provide a high level of confidence of compliance with state and federal discharge guidelines. The University of Alabama at Birmingham (UAB) developed an integrated water sensor package for continuous water quality monitoring of flue gas desulfurization (FGD) wastewaters for concentration measurements of Selenium (Se). UAB utilized a diverse team of University Professors/Staff Members/Student(s) (Engineering and Innovative Technology Development Group), a University Affiliated Research Institution from the local area (Southern Research), and a cost sharing Industry Partner (Metrohm). The team developed and validated a proprietary wet chemistry batch process for water sample preparation; and implemented this process as a fully automated on-line monitor prototype system. This prototype system’s performance was evaluated in both the laboratory and during in-field deployment to a coal fired power plant. In both environments it was found that the prototype system was unable to recreate the batch process’s success at preparing FGD water samples for total Se measurements with a commercial-off-the-shelf (COTS) cyclic anodic stripping voltammetry (CSV) system. Through this experience, UAB has provided insight into a number of specific areas where improvements can be made with respect to the COTS systems used in this project to yield a more complete and competitive industry solution for on-line monitoring of total Se in industrial wastewater.

20 FOSSIL-FUELED POWER PLANTS↗

Continuous Water Quality Sensing for FGD Wastewater

The coal fired plant power industry requires new solutions for on-line monitoring of flue gas desulfurization (FGD) wastewaters for regulated trace metals to reduce recurring operating and off-site laboratory analysis costs and provide a high level of confidence of compliance with state and federal discharge guidelines. The University of Alabama at Birmingham (UAB) developed an integrated water sensor package for continuous water quality monitoring of flue gas desulfurization (FGD) wastewaters for concentration measurements of Selenium (Se). UAB utilized a diverse team of University Professors/Staff Members/Student(s) (Engineering and Innovative Technology Development Group), a University Affiliated Research Institution from the local area (Southern Research), and a cost sharing Industry Partner (Metrohm). The team developed and validated a proprietary wet chemistry batch process for water sample preparation; and implemented this process as a fully automated on-line monitor prototype system. This prototype system’s performance was evaluated in both the laboratory and during in-field deployment to a coal fired power plant. In both environments it was found that the prototype system was unable to recreate the batch process’s success at preparing FGD water samples for total Se measurements with a commercial-off-the-shelf (COTS) cyclic anodic stripping voltammetry (CSV) system. Through this experience, UAB has provided insight into a number of specific areas where improvements can be made with respect to the COTS systems used in this project to yield a more complete and competitive industry solution for on-line monitoring of total Se in industrial wastewater.

01 COAL, LIGNITE, AND PEAT↗

Satellite Data of Atmospheric Pollution for U.S. Air Quality Applications: Examples of Applications, Summary of Data End-user Resources, Answers to Faqs, and Common Mistakes to Avoid

Satellite data of atmospheric pollutants are becoming more widely used in the decision-making and environmental management activities of public, private sector and non-profit organizations. They are employed for estimating emissions, tracking pollutant plumes, supporting air quality forecasting activities, providing evidence for "exceptional event" declarations, monitoring regional long-term trends, and evaluating air quality model output. However, many air quality managers are not taking full advantage of the data for these applications nor has the full potential of satellite data for air quality applications been realized. A key barrier is the inherent difficulties associated with accessing, processing, and properly interpreting observational data. A degree of technical skill is required on the part of the data end-user, which is often problematic for air quality agencies with limited resources. Therefore, we 1) review the primary uses of satellite data for air quality applications, 2) provide some background information on satellite capabilities for measuring pollutants, 3) discuss the many resources available to the end-user for accessing, processing, and visualizing the data, and 4) provide answers to common questions in plain language.

remote sensing↗

Impact of the 2008 Global Recession on Air Quality over the United States: Implications for Surface Ozone Levels from Changes in NOx Emissions

Satellite and ground observations detected large variability in nitrogen oxides (NOx) during the 2008 economic recession, but the impact of the recession on air quality has not been quantified. This study combines observed NOx trends and a regional chemical transport model to quantify the impact of the recession on surface ozone (O3) levels over the continental United States. The impact is quantified by simulating O3 concentrations under two emission scenarios: business-as-usual (BAU) and recession. In the BAU case, the emission projection from the Cross-State Air Pollution Rule is used to estimate the would-be NOx emission level in 2011. In the recession case, the actual NO2 trends observed from Air Quality System ground monitors and the Ozone Monitoring Instrument on the Aura satellite are used to obtain realistic changes in NOx emissions. The model prediction with the recession effect agrees better with ground O3 observations over time and space than the prediction with the BAU emission. The results show that the recession caused a 12ppbv decrease in surface O3 concentration over the eastern United States, a slight increase (0.51ppbv) over the Rocky Mountain region, and mixed changes in the Pacific West. The gain in air quality benefits during the recession, however, could be quickly offset by the much slower emission reduction rate during the post-recession period.

NOx emissions↗

SECARB Geochemical Data

Hydrotest, gas composition, injection fluid, mass spectrometer, and U-tube gas sample analysis data gathered during SECARB project at Cranfield oil site in Mississippi. Geochemical data collected as part of geologic characterization phase of SECARB. Associated Publications: Lu, J., Cook, P. J., Hosseini, S. A., Yang, C., Romanak, K. D., Zhang, T., Freifeld, B. M., Smyth, R. C., Zeng, H., and Hovorka, S. D., 2012, Complex fluid flow revealed by monitoring CO 2 injection in a fluvial formation: Journal of Geophysical Research, v. 117, B03208, doi:10.1029/2011JB008939. Lu, J., Kharaka, Y. K., Thordsen, J. J., Horita, J., Karamalidis, A., Griffith, C., Hakala, J. A., Ambats, G., Cole, D. R., Phelps, T. J., Manning, M. A., Cook, P. J., and Hovorka, S. D., 2012, CO 2 -rock-brine interactions in Lower Tuscaloosa Formation at Cranfield CO2 sequestration site, Mississippi, U.S.A.: Chemical Geology, v. 291, p. 269-277. Yang, C., Hovorka, S. D., Treviño, R. H., and Delgado-Alonso, J., 2015, Integrated framework for assessing impacts of CO 2 leakage on groundwater quality and monitoring-network efficiency: case study at a CO 2 enhanced oil recovery site: Environmental Science &Technology, v. 49, p. 8887–8898, doi:10.1021/acs.est.5b01574.

carbon capture and storage↗

Three Years of Multilevel Monitoring Data at the Riverton, Wyoming, Processing Site That Show Contaminant Increases After River Flooding Events and a Large Recharge Event

The tailings pile at the Riverton, Wyoming, Processing Site has been removed, but contaminant concentrations in the shallow aquifer increase after large recharge events. The Riverton site experienced flooding near the Little Wind River in early May 2016, February 2017, and June 2017. The May 2016 flooding was from a large rain event. The February 2017 flooding was due to an ice jam, and the June 2017 flooding was due to mountain snowmelt runoff. In addition, the site experienced high water tables in April and May 2017, as this was the second wettest spring in Riverton since records began in 1918. Past reports indicated the accumulation of solid-phase uranium and molybdenum in evaporites above the respective contaminant groundwater plumes. Given these data, multilevel monitoring wells were installed in 2015 to monitor seasonal changes in groundwater quality. Data from three years of groundwater monitoring are summarized in this report and compared with the flooding and large recharge events. The results indicate that evaporite-related constituents (especially sodium, sulfate, and chloride) present across the site in a silt layer can be released to the shallow sand and gravel aquifer during flooding and large recharge events. The solid-phase and water-phase data confirm that these evaporites are mainly sodium sulfate and sodium chloride salts with some calcite and gypsum.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Utility of MODIS Aerosol Optical Depth for Estimating PM2.5 Exposure in Environmental Public Health Surveillance

As part of the National Environmental Public Health Tracking Network (EPHTN) the National Center for Environmental Health (NCEH) at the Centers for Disease Control and Prevention (CDC) is leading a project called Health and Environment Linked for Information Exchange (HELIX-Atlanta). The goal of developing the National Environmental Public Health Tracking Network is to improve the health of communities. Currently, few systems exist at the state or national level to concurrently track many of the exposures and health effects that might be associated with environmental hazards. An additional challenge is estimating exposure to environmental hazards such as particulate matter whose aerodynamic diameter is less than or equal to 2.5 micrometers (PM(2.5)) HELIX-Atlanta's goal is to examine the feasibility of building an integrated electronic health and environmental data network in five counties of Metropolitan Atlanta, GA (Clayton, Cobb, DeKalb, Fulton, and Gwinnett counties). Under HELIX-Atlanta, pilot projects are being conducted to develop methods to characterize exposure; link health and environmental data; analyze the relationship between health and environmental factors; and communicate findings. NASA Marshall Space Flight Center (NASA/MSFC) is collaborating with CDC to combine NASA earth science satellite observations related to air quality and environmental monitoring data to model surface estimates of PM(2.5) concentrations that can be linked with clinic visits for asthma. From 1999-2000 there were over 9,400 hospitalizations per year in Georgia with asthma as the primary diagnosis. The majority of these hospitalizations occurred in medical facilities in the five most populous Metro-Atlanta counties. Hospital charges resulting from asthma in Georgia are approximately $59 million dollars annually. There is evidence in the research literature that asthmatic persons are at increased risk of developing asthma exacerbations with exposure to environmental factors, including PM(2.5). Thus, HELIX-Atlanta is focusing on methods for characterizing population exposure to PM(2.5) for the Atlanta metropolitan area that could be used in on-going surveillance. While use of the Air Quality System, (AQS) PM(2.5) data alone could meet HELIX Atlanta, specifications, there are only five AQS sites in the Atlanta area, thus the spatial coverage is not ideal. Also, the AQS ground observations are made at time intervals ranging from one hour to six days leaving some temporal gaps. NASA Moderate Resolution Imaging Spectroradiometer (MODIS) satellite Aerosol Optical Depth (AOD) data have the potential for estimating daily ground level PM(2.5) at 10 km resolution over the metropolitan Atlanta area supplementing the AQS ground observations and filling their spatial and temporal gaps.

Al-Hamdan, Mohammad↗

Reuse Permit I-161-02 Quality Assurance Project Plan (QAPP) for Required Environmental and Process Monitoring Idaho National Laboratory Advanced Test Reactor (ATR) Complex Cold Waste Ponds

The Department of Environmental Quality (DEQ) issued Reuse Permit No. I-161-02 (hereafter permit) for the Idaho National Laboratory (INL) Advanced Test Reactor (ATR) Complex Cold Waste Ponds (CWP) on November 20, 2014, with minor Modification 1 effective March 7, 2017. Permit Section 3 compliance activity (CA), CA-161-02, requires the permittee to prepare and implement a Quality Assurance Project Plan (QAPP) within 6 months of permit issuance. This QAPP is prepared in accordance with CA-161-02 using a template provided by DEQ.

99 GENERAL AND MISCELLANEOUS↗

Effective Documentation Tools

Quality assurance programs provide a very effective means to monitor and evaluate medical care. Quality assurance involves: (1) Identify a problem; (2) Determine the source and nature of the problem; (3) Develop policies and methods to effect improvement; (4) Implement those polices; (5) Monitor the methods applied; and (6) Evaluate their effectiveness. Because this definition of quality assurance so closely resembles the Nursing Process, the health unit staff was able to use their knowledge of the nursing process to develop many forms which improve the quality of patient care. These forms include the NASA DFRC Service Report, the occupational injury form (Incident Report), the patient survey (Pre-hospital Evaluation/Care Report), the Laboratory Log Sheet, the 911 Run Sheet, and the Patient Assessment Stamp. Examples and steps which are followed to generate these reports are described.

Sleboda, Claire↗

Sea WiFS Postlaunch Technical Report Series: The SeaBOARR-99 Field Campaign - Volume 8

This report documents the scientific activities during the second Sea-viewing Wide Field-of-view Sensor (Sea- WIFS) Bio-Optical Algorithm Round-Robin (SeaBOARR-99) field campaign, which took place from 2 May to 7 June 1999 on board the Royal Research Ship James Clark Ross during the eighth Atlantic Meridional Transect cruise (AMT-8). The ultimate objective of the SeaBOARR activity is to evaluate the effect of different measurement protocols on bio-optical algorithms using data from a variety of field campaigns. The SeaBOARR-99 field campaign was concerned with collecting a high quality data set of simultaneous in-water and above-water radiometric measurements. The deployment goals documented in this report were to: a) use four different surface glint correction methods to compute water-leaving radiances, Lw(lambda), from above-water data; b) use two different in-water profiling systems and three different methods to compute Lw(lambda) from in-water data; c) use instruments with a common calibration history to minimize intercalibration uncertainties; d) monitor the calibration stability of the instruments in the field with the original SeaWiFS Quality Monitor (SQM) and a commercial, second-generation device called the SQM-II, thereby allowing a distinction between differences in methods from changes in instrument performance; and e) compare the Lw(lambda) values estimated from the above- water and in- water measurements. In addition to describing the instruments deployed and the data collected, a preliminary analysis of part of the SeaBOARR-99 data set is presented (using only the data collected during clear sky, calm sea, and Case-I waters).

Hooker, Stanford B.↗

Neutron Gamma-Method for Monitoring Ash Content of Coal

A brief analysis is given of the modern instrumental methods of monitoring the ash content of coal. Their particulars and drawbacks are examined. A neutron gamma-method of monitoring the ash content is proposed on the basis of integrated use of prompt γ-radiation accompanying inelastic scattering of fast neutrons and radiative capture of thermal neutrons by nuclei of the primary elements comprising the organic and mineral components of coal. The instrumental-methodological parameters of monitoring (sizes of the analyzed samples, energy intervals of the detected gamma radiation) making it possible to the increase the sensitivity of the method with respect to the ash content and to minimize the impact of the variability of the moisture content of coal on its material composition, are optimized. The method has been certified and recommended for representative monitoring of the quality of coarse coal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using gap-filled MAIAC AOD and WRF-Chem to estimate daily PM 2.5 concentrations at 1 km resolution in the Eastern United States

To link short-term exposures of air pollutants to health outcomes, scientists must use high temporal and spatial resolution estimates of PM 2.5 concentrations. We develop a daily PM 2.5 product at 1 × 1 km 2 spatial resolution across the eastern United States (east of 90° W) with the aid of 1 × 1 km 2 MAIAC aerosol optical depth (AOD) data, 36 × 36 km 2 WRF-Chem output, 1 × 1 km 2 land-use type from the National Land Cover Database, and 0.125° × 0.125° ERA-Interim re-analysis meteorology. A gap-filling technique is applied to MAIAC AOD data to construct robust daily estimates of AOD when the satellite data are missing (e.g., areas obstructed by clouds or snow cover). The input data are incorporated into a multiple-linear regression model trained to surface observations of PM 2.5 from the EPA Air Quality System (AQS) monitoring network. The model generates a high-fidelity estimate (r 2 = 0.75 using a 10-fold random cross-validation) of daily PM 2.5 throughout the eastern United States. Of the inputs to the statistical model, WRF-Chem output (r 2 = 0.66) is the most important contributor to the skill of the model. MAIAC AOD is also a strong contributor (r 2 = 0.52). Daily PM 2.5 output from our statistical model can be easily integrated into county-level epidemiological studies. The novelty of this project is that we are able to simulate PM 2.5 in a computationally efficient manner that is constrained to ground monitors, satellite data, and chemical transport model output at high spatial resolution (1 × 1 km 2 ) without sacrificing the temporal resolution (daily) or spatial coverage (>2,000,000 km 2 ).

47 OTHER INSTRUMENTATION↗

Year-round trace gas measurements in the central Arctic during the MOSAiC expedition

Despite the key role of the Arctic in the global Earth system, year-round in-situ atmospheric composition observations within the Arctic are sparse and mostly rely on measurements at ground-based coastal stations. Measurements of a suite of in-situ trace gases were performed in the central Arctic during the Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) expedition. These observations give a comprehensive picture of year-round near-surface atmospheric abundances of key greenhouse and trace gases, i.e., carbon dioxide, methane, nitrous oxide, ozone, carbon monoxide, dimethylsulfide, sulfur dioxide, elemental mercury, and selected volatile organic compounds (VOCs). Redundancy in certain measurements supported continuity and permitted cross-evaluation and validation of the data. This paper gives an overview of the trace gas measurements conducted during MOSAiC and highlights the high quality of the monitoring activities. In addition, in the case of redundant measurements, merged datasets are provided and recommended for further use by the scientific community.

54 ENVIRONMENTAL SCIENCES↗

Quadrupolar mode measurements for space charge dominated beams

On-line monitoring of beam quality requires non-invasive transverse phase space diagnostics. Emittance measurement is particularly challenging for high-intensity particle beams, since space charge complicates the beam dynamics during measurement. Quadrupolar mode measurements have been empirically shown to provide information about the beam emittance, but so far only for small relative space charge effects, where the results depend on a linear theory. We present a quadrupolar mode measurement for space charge dominated beams with unsplit tunes using multi-turn resonant excitation. Furthermore, results from experiments performed at the University of Maryland Electron Ring (UMER) are compared to both analytic and numerical analysis of the rms envelope equations.

43 PARTICLE ACCELERATORS↗

Technical Note: SCUDA: A software platform for cumulative dose assessment

Purpose: Accurate tracking of anatomical changes and computation of actually delivered dose to the patient are critical for successful adaptive radiation therapy (ART). Additionally, efficient data management and fast processing are practically important for the adoption in clinic as ART involves a large amount of image and treatment data. The purpose of this study was to develop an accurate and efficient Software platform for CUmulative Dose Assessment (SCUDA) that can be seamlessly integrated into the clinical workflow. Methods: SCUDA consists of deformable image registration (DIR), segmentation, dose computation modules, and a graphical user interface. It is connected to our image PACS and radiotherapy informatics databases from which it automatically queries/retrieves patient images, radiotherapy plan, beam data, and daily treatment information, thus providing an efficient and unified workflow. For accurate registration of the planning CT and daily CBCTs, the authors iteratively correct CBCT intensities by matching local intensity histograms during the DIR process. Contours of the target tumor and critical structures are then propagated from the planning CT to daily CBCTs using the computed deformations. The actual delivered daily dose is computed using the registered CT and patient setup information by a superposition/convolution algorithm, and accumulated using the computed deformation fields. Both DIR and dose computation modules are accelerated by a graphics processing unit. Results: The cumulative dose computation process has been validated on 30 head and neck (HN) cancer cases, showing 3.5 ± 5.0 Gy (mean±STD) absolute mean dose differences between the planned and the actually delivered doses in the parotid glands. On average, DIR, dose computation, and segmentation take 20 s/fraction and 17 min for a 35-fraction treatment including additional computation for dose accumulation. Conclusions: The authors developed a unified software platform that provides accurate and efficient monitoring of anatomical changes and computation of actually delivered dose to the patient, thus realizing an efficient cumulative dose computation workflow. Evaluation on HN cases demonstrated the utility of our platform for monitoring the treatment quality and detecting significant dosimetric variations that are keys to successful ART.

60 APPLIED LIFE SCIENCES↗