Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Bayesian merging of numerical modeling and remote sensing for saltwater intrusion quantification in the Vietnamese Mekong Delta

Saltwater intrusion has become one of the most concerning issues in the Vietnamese Mekong Delta (VMD) due to its increasing impacts on agriculture and food security of Vietnam. Reliable estimation of salinity plays a crucial role to mitigate the impacts of saltwater intrusion. Here, this study developed a hybrid technique that merges satellite imagery with numerical simulations to improve the estimation of salinity in the VMD. The salinity derived from Landsat images and by numerical simulations was fused using the Bayesian inference technique. The results indicate that our technique significantly reduces the uncertainties and improves the accuracy of salinity estimates. The Nash–Sutcliffe coefficient is 0.74, which is much higher than that of numerical simulation (0.63) and Landsat estimation (0.6). The correlation coefficient between the ensemble and measured salinity is relatively high (0.88). The variance of the ensemble salinity errors (5.0 ppt 2 ) is lower than that of Landsat estimation (10.4 ppt 2 ) and numerical simulations (9.6 ppt 2 ). The proposed approach shows a great potential to combine multiple data sources of a variable of interest to improve its accuracy and reliability wherever these data are available.

54 ENVIRONMENTAL SCIENCES↗

Quantification of the Interaction Field in Arrays of Magnetic Nanowires from the Remanence Curves

A method is presented that allows quantifying the average value of the interaction field in arrays of magnetic nanowires from the field difference between the isothermal remanence (IRM) and the DC demagnetizing (DCD) remanence curves when the normalized magnetization is equal to one third. Arrays of magnetic nanowires of different diameters and packing fractions are used to experimentally test the method. The results have been compared with those obtained using the method based on the difference between the remanence coercivity fields and with a mean-field expression for the interaction field, providing a very good agreement and thus validating the method. Additionally, it is shown that both the position (m{sub 0}) and the shift along the magnetization axis of the intersection between the remanence curves with respect to the value of one third (δm = m{sub 0} − 1/3) provide qualitative information about the interaction field. The former indicates the type of interaction depending if the intersection is above (m{sub 0} > 1/3) or below (m{sub 0} < 1/3), which corresponds to a ferro or anti-ferro magnetic interaction, respectively. While for the latter, it is shown that the maximum deviation of the Delta-M plot from zero (ΔM{sub max}) corresponds to three times the shift (ΔM{sub max} = 3δm).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantification techniques of mass-separation and ion yield for the detection of radioactive isotopes

This research demonstrates two methods of quantifying isotope separation efficiency using an inductively coupled plasma mass spectrometer. One method measured the accumulated charge on a conductive collection substrate in real-time while the second method performed a chemical dissolution of the substrate with subsequent post-processing and analysis. Our previous results demonstrated and compared these methods with a multi-element standard of stable isotopes. This research applies these methods to quantifying radioactive isotopes utilizing measurements of the stable isotope at the same mass-to-charge ratio. The mass-separated radioactive isotope were fission products produced from thermal neutron irradiation of a highly enriched 235U foil. The two methods are explained and the results of this new separation methodology are compared to available cumulative fission yields.

Dion, Michael P.↗

Quantification of uranium metal and total uranium in U-UO 2 mixtures using H 3 PO 4 -HCl

Here, the selective dissolution of uranium metal from its mixtures with UO 2 was studied to establish a simple and rapid quantitative method. Uranium metal was found to selectively dissolve as U(IV) into a solution of phosphoric and hydrochloric acids, with quantitative dissolution occurring within 1 h. Total dissolution of uranium as U(VI) could then be obtained by nitric acid addition and heating for 0.5–1 h. Analysis of the resulting U(IV) and U(VI) solutions by ICP-OES or UV–Vis spectroscopy yielded uranium metal-to-UO 2 ratios with an accuracy of ± 10% or better. Accuracy of the ICP-OES method was slightly better than UV–Vis, but the simplicity of the latter makes it an attractive option for some applications.

36 MATERIALS SCIENCE↗

Remote quantification of Cm(III) and HNO 3 by fluorescence spectroscopy and chemometrics

A unique approach to remotely quantify Cm(III) (0–100 µg mL −1 ) in HNO 3 (1–12 M) using steady-state laser fluorescence spectroscopy and multivariate regression models was developed. Photoluminescence is amenable to remote measurements using fiber-optic cables and is sensitive to numerous lanthanide and actinide species. In-line measurements can provide feedback to support complex processing in harsh environments (e.g., hot cells) to help guide and optimize radiochemical separations. In this work, Cm(III) spectra were acquired remotely in a glove box as a function of HNO 3 concentration to better understand spectral characteristics and evaluate the utility of multivariate regression models in this system. Furthermore, the Cm(III) fluorescence peak shape, width, position, and intensity changed significantly as a function of HNO 3 concentration, likely because of the displacement of emission quenching inner-sphere water molecules and complexation with nitrate ions. Despite significant covariance and nonlinearity in the data, a D-optimal design strategy successfully minimized training set sample size and was used to build effective partial least squares regression models for Cm(III) and HNO 3 concentrations without a priori knowledge of solution conditions. Chemometrics for modeling complex fluorescence spectra are promising and may find widespread applicability for online analysis in numerous chemical systems found in the nuclear field.

Actinide↗

A single external cavity laser-based sensor for simultaneous detection and quantification of atmospheric methane and water vapor

A single external cavity diode laser (ECDL)-based sensor system was developed for simultaneous measurements of methane and water vapor in the atmospheric air. A home-made continuous wave (CW) ECDL with a wavelength of ∼ 1325 nm was employed to cover two absorption lines for different gas species. A high-finesse optical cavity composed of two high-reflectivity mirrors (R=0.99927) was used to enhance the gas absorption in a space of 0.5 l. An isolated methane absorption line at 7552.74 cm{sup −1} and a common (non-isolated) absorption line of water vapor and methane 7552.81cm{sup −1} were utilized for simultaneous detection. A method was developed to calculate the water vapor concentration from these lines. To our knowledge, the method and the absorption lines used in the present paper were used for the first time for simultaneous measurement of the concentrations of atmospheric methane and water vapor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Liquid Inclusion Distortion by Lens Shape Effect: In Situ Observation and Quantification on LCAK Steels Using HT-CSLM

Because of interfacial and surface tension, micron-sized liquid oxide droplets are expected to change from spherical (when fully immersed in liquid steel) to lens shape on top of steel. Inclusion sizes were measured by automated analysis of polished sections of calcium-treated aluminum-killed steel. A sample of the same steel was remelted and observed using confocal scanning laser microscopy. Droplets on the steel surface appear to have approximately twice the diameter of fully immersed spherical inclusions.

36 MATERIALS SCIENCE↗

In-situ quantification of the surface roughness for facile fabrications of atomically smooth thin films

Here in this work we present an in-situ technique to quantify the layer-by-layer roughness of thin films and heterostructures by measuring the spectral profile of the reflection high-energy electron diffraction (RHEED). The characteristic features of the diffraction spot, including the vertical to lateral size ratio c/b and the asymmetrical ratio c 1 /c 2 along the vertical direction, are found to be quantitatively dependent on the surface roughness. The quantitative relationships between them are established and discussed for different incident angles of high-energy electrons. As an example, the surface roughnesses of LaCoO 3 films grown at different temperatures are obtained using such an in-situ technique, which are confirmed by the ex-situ atomic force microscopy. Moreover, the in-situ measured layer-by-layer roughness oscillations of two LaCoO 3 films are demonstrated, revealing drastically different information from the intensity oscillations. The experiments assisted with the in-situ technique demonstrate an outstanding high resolution down to similar to ~0.1 Å. Therefore, the new quantitative RHEED technique with real-time feedbacks significantly escalates the thin film synthesis efficiency, especially for achieving atomically smooth surfaces and interfaces. It opens up new prospects for future generations of thin film growth, such as the artificial intelligence-assisted thin film growth.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Relationship of non-invasive quantification of myocardial blood flow to arrhythmic events in patients with implantable cardiac defibrillators

Background: Ischemia contributes to arrhythmogenesis though its role is incompletely understood. Abnormal myocardial perfusion measured by PET imaging may predict ventricular arrhythmias (VAs) in a high-risk population. Methods: Patients with implantable cardiac defibrillators who had undergone rubidium-82 cardiac PET imaging were identified. Patients were stratified by median MBF and MFR values for analysis. The Cox proportional hazards model was used to assess the impact of myocardial perfusion on survival free of VT independent of critical covariates. Results: A total of 159 patients (124 (78%) males, median age 65.9 years, IQR [56.76-72.63]) were followed for 1.43 years IQR [0.83-2.21]. VA occurred in 29 patients (23.7%). After adjustment for ejection fraction, age, and sex, impaired stress MBF was associated with an increased risk of VA (adjusted HR per ml/min/g 1.52, 95% CI (1.01-2.31), P = 0.04). Summed rest and stress scores were not predictive of VA. Among patients with severe LV dysfunction, stress MBF remained an independent predictor of VA (adjusted HR per 1 ml/min/g HR 1.69, 95% CI (1.03-11.36), P = 0.03), while residual EF, summed rest, and summed stress scores were not (P > 0.05). Conclusions: Impaired stress myocardial blood flow was associated with less survival free of ventricular arrhythmias.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correction to: Clinical Quantification of Myocardial Blood Flow Using PET: Joint Position Paper of the SNMMI Cardiovascular Council and the ASNC

The above position statement originally published containing errors in the author metadata; specifically, the Expert Content Reviewers—Andrew Einstein, Raymond Russell and James R. Corbett—were tagged as full authors of the paper. The article metadata has now been corrected to remove Drs. Einstein, Russell and Corbett from the author line, and the PubMed record has been updated accordingly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗