Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Complete Genome Assembly of Enterococcus faecalis 29212, a Laboratory Reference Strain

Enterococcus faecalis is a nonmotile Gram-positive coccus, found both as a commensal organism in healthy humans and animals and as a causative agent of multiple diseases, in particular endocarditis. We sequenced the genome of E. faecalis ATCC 29212, a commonly used reference strain in laboratory studies, to complete “finished” annotated assembly (3 Mb).

59 BASIC BIOLOGICAL SCIENCES↗

Elementary reference for the analysis of high-energy nuclear collisions

In this contribution we shall discuss some aspects of the role of elementary reference data for the interpretation of the results from nuclear collisions and show in particular that neutron-proton interactions play a significant role. Furthermore we point out that a complete set of elementary data is desirable, because most theoretical concepts for the interpretation of nuclear collisions rely on such data as input for their calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling of reference operating scenario of GOL-NB multiple-mirror trap

Currently, the GOL-NB multiple-mirror trap is being developed at the Budker Institute of Nuclear Physics, Siberian Branch, Russian Academy of Sciences. The main scientific goal pursued by building GOL-NB is direct demonstration of suppression of longitudinal losses of particles and energy from the trap by using sections with a multiple-mirror magnetic field, which can be attached to the central gas-dynamic trap. Plasma heating in GOL-NB will be accomplished by neutral beam injection with a power of up to 1.5MW. The paper presents the first results of modeling the dynamics of the plasma parameters and fast ions under the reference operating scenario of the trap in which traditional short magnetic mirrors, rather than multiple-mirror sections, are attached to the central trap. In such a configuration, the plasma lifetime in the trap is expected to be minimal. The modeling was performed by using the DOL kinetic code. As a result, the initial conditions of the experiments are refined and the requirements to the system of maintaining the particle balance in the trap are determined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of Compton suppression for enhancing trace element identification in neutron activation analysis of reference materials

Neutron activation analysis (NAA) is a powerful technique for identifying and quantifying trace elements in materials. However, challenges such as high dead times, spectral interferences, and high Compton continuum often arise. This study employs a Compton suppression system (CSS) to enhance NAA sensitivity by reducing the Compton continuum, thereby improving the peak-to-Compton ratio. National Institute of Standards and Technology certified reference materials 1632d, 1633c, and Canadian National Research Council TORT-1 were irradiated in a thermal and epithermal neutron flux under various irradiation, decay and counting times and analyzed using high-resolution gamma-ray spectroscopy with and without Compton suppression. The reduction factor was calculated to evaluate the effectiveness of the CSS, demonstrating significant background reduction and improved detection limits for trace elements. Additional experiments with a 137Cs point source demonstrated the impact of detector-source geometry on system performance, showing a decrease in the reduction factor as the source was moved further from the NaI detector. An optimum distance between the source and HPGe detector was observed, yielding the highest peak-to-Compton ratio. The results highlight the CSS's ability to minimize spectral interference and enhance elemental identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Open SHMEM Reference Implementation

OpenSHMEM is an effort to create a specification for a standardized API for parallel programming in the Partitioned Global Address Space. Along with the specification the project is also creating a reference implementation of the API. This implementation attempts to be portable, to allow it to be deployed in multiple environments, and to be a starting point for implementations targeted to particular hardware platforms. It will also serve as a springboard for future development of the API.

Pritchard, Howard↗

Norms, Norm Sets, and Reference Groups: Implications for Household Interest in Energy Technologies

Household adoption of rooftop solar panels and battery storage can potentially reduce the negative environmental impacts of the electric grid. We argue that the number of socially close (friends and family) and geographically close (neighbors) others who have rooftop solar panels will affect norm expectations regarding how much others approve of solar panels and battery storage and expectations about how personally beneficial those technologies are likely to be. We test our hypotheses using survey data collected from California homeowners and find partial support. We find evidence for the significance of socially close others (rather than neighbors), highlighting the importance of identifying the appropriate reference groups when studying norms. Our results also provide insight into how one category of behavior (adoption of solar panels) can influence norm expectations about another less visible behavior (battery storage), suggesting a mechanism that may contribute to norms regulating private behaviors.

Horne, Christine↗

IDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms

To date, the estimated radiation-absorbed dose to organs and tissues in patients undergoing diagnostic examinations in nuclear medicine is derived via calculations based on models of the human body and the biokinetic behaviour of the radiopharmaceutical. An internal dosimetry computer program, IDAC-Dose2.1, was developed based on the International Commission on Radiological Protection (ICRP)-specific absorbed fractions and computational framework of internal dose assessment given for reference adults in ICRP Publication 133. The program uses the radionuclide decay database of ICRP Publication 107 and considers 83 different source regions irradiating 47 target tissues, defining the effective dose as presented in ICRP Publications 60 and 103. The computer program was validated against another ICRP dosimetry program, Dose and Risk Calculation (DCAL), that employs the same computational framework in evaluation of occupational and environmental intakes of radionuclides. IDAC-Dose2.1 has a sub-module for absorbed dose calculations in spherical structures of different volumes and composition; this sub-module is intended for absorbed dose estimates in radiopharmaceutical therapy. For nine specific alpha emitters, the absorbed dose contribution from their decay products is also included in the committed absorbed dose calculations. The absorbed doses and effective dose of 131 I-iodide determined by IDAC-Dose2.1 were validated against the dosimetry program DCAL, showing identical results. IDAC-Dose2.1 was used to calculate absorbed doses for intravenously administered 18 F-FDG and orally administered 99m Tc-pertechnetate and 131 I-iodide, three frequently used radiopharmaceuticals. Using the tissue weighting factors from ICRP Publication 103, the effective dose per administered activity was estimated to be 0.016 mSv/MBq for 18 F-FDG, 0.014 mSv/MBq for 99m Tc-pertechnetate, and 16 mSv/MBq for 131 I-iodide. The internal dosimetry program IDAC-Dose2.1 was developed and applied to three radiopharmaceuticals for validation against DCAL and to generate improved absorbed dose estimations for diagnostic nuclear medicine using specific absorbed fraction values of the ICRP computational voxel phantoms. The sub-module for absorbed dose calculations in spherical structures 1 mm to 9 cm in diameter and different tissue composition was included to broaden the clinical usefulness of the program. The IDAC-Dose2.1 program is free software for research and available for download at http://www.idac-dose.org.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reference solutions for linear radiation transport: the Hohlraum and Lattice Benchmarks

Radiation transport describes the propagation of energetic particles through space as they interact with a surrounding material medium. In a kinetic description, radiation transport is modeled by a radiation transport equation (RTE) that prescribes the density of the radiation in position-momentum phase space. The purpose of this dataset is to provide highly resolved solutions to two benchmark problems. These two benchmarks do not possess exact solutions; moreover, the construction of a manufactured solution may require a non-physical source that is not desirable, especially if it spoils the physical nature of the solution. Thus the goal of this computational study is to provide a highly resolved reference solution for testing newer, more cost efficient methods that are currently being developed in the research community.

97 MATHEMATICS AND COMPUTING↗

Highly accurate Michelson type wavelength meter that uses a rubidium stabilized 1560 nm diode laser as a wavelength reference

We investigated the accuracy limitation of a wavelength meter installed in a vacuum chamber to enable us to develop a highly accurate meter based on a Michelson interferometer in 1550 nm optical communication bands. We found that an error of parts per million order could not be avoided using famous wavelength compensation equations. Chromatic dispersion of the refractive index in air can almost be disregarded when a 1560 nm wavelength produced by a rubidium (Rb) stabilized distributed feedback (DFB) diode laser is used as a reference wavelength. We describe a novel dual-wavelength self-calibration scheme that maintains high accuracy of the wavelength meter. The method uses the fundamental and second-harmonic wavelengths of an Rb-stabilized DFB diode laser. Consequently, a highly accurate Michelson type wavelength meter with an absolute accuracy of 5x10{sup -8} (10 MHz, 0.08 pm) over a wide wavelength range including optical communication bands was achieved without the need for a vacuum chamber.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Value of Information References

This file contains a list of relevant references on value of information (VOI) in RIS format. VOI provides a quantitative analysis to evaluate the outcome of the combined technologies (seismology, hydrology, geodesy) used to monitor Brady's Geothermal Field.

15 GEOTHERMAL ENERGY↗

Poroelastic references

This file contains a list of relevant references on the Biot theory (forward and inverse approaches), the double-porosity and dual-permeability theory, and seismic wave propagation in fracture porous media, in RIS format, to approach seismic monitoring in a complex fractured porous medium such as Brady?s Geothermal Field.

15 GEOTHERMAL ENERGY↗

Hawthorne Nevada Deep Direct-Use Feasibility Study - References, Reports, Literature

The objective of this project is to use a multi-disciplinary, three-tiered approach to assess the geothermal resource and determine the feasibility of implementing a large-scale, direct-use facility for the Hawthorne Army Depot (HAD) and the various town and county facilities in Hawthorne, Nevada. This assessment directly targets a geothermal resource recently characterized by the Navy Geothermal Program Office (GPO) as part of a focused exploration and development campaign. Data includes: Zip folder containing information from Bjornstad. Includes isotope, temperature, water, well, and reports from 2002; Zip folder contains PDF and power point files of references for the Hawthorne Geothermal project; Zip folder containing PDF files of the literature cited in the proposal.

15 GEOTHERMAL ENERGY↗

Reference Shapefiles and Pre-trained Random Forest Classification Models for Detecting Aufeis on the North Slope of Alaska in Landsat Imagery

This dataset provides shapefiles and trained machine learning models used for aufeis detection at four sites on the North Slope of Alaska. It includes reference data for evaluating Landsat-based detection methods, supporting research on remote sensing approaches for identifying aufeis. The ReferenceData folder contains ArcGIS shapefiles of semi-automated land cover classifications for 217 Landsat Collection 2 images, categorizing pixels into six classes: aufeis, snow, ground, none, water, and cloud. The SiteBuffers.zip file includes 10-kilometer buffer shapefiles defining regions of interest around four aufeis fields (Canning21, FH1, Firth, and Kuparuk), used to test three detection techniques. Additionally, the TrainedRFModels folder contains six pre-trained Scikit-Learn Random Forest classifiers (100 trees, max depth = 30) designed to predict aufeis presence in Landsat Collection 2 Surface Reflectance images using Red, Blue, SWIR2, NDVI, and NDWI bands. This dataset supports the development and validation of remote sensing methods for mapping aufeis in Arctic environments.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Carbon (1s) NEXAFS Spectroscopy of Biogeochemically Relevant Reference Organic Compounds

Natural organic matter (NOM) is a highly active component of soils and sediments, and plays an important role in global C cycling. However, NOM has defied molecular-level structural characterization, owing to variations along the decomposition continuum and its existence as highly functionalized polyelectrolytes. We conducted a comprehensive systematic overview of spectral signatures and peak positions of major organic molecules that occur as part of NOM using near-edge x-ray absorption fine structure (NEXAFS) spectroscopy. This investigation provides a more comprehensive NEXAFS spectral library of biogeochemically relevant organic C compounds. The spectra of these reference organic compounds reveal distinct spectral features and peak positions at the C K-edge that are characteristic of the molecular orbitals bonding C atoms. Detailed structural information can be derived from these distinctive spectral features that could be used to build robust peak assignment criteria to exploit the chemical sensitivity of NEXAFS spectroscopy for in situ molecular-level spatial investigation and fingerprinting of complex organic C compounds in environmental samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tests of Coordinate Transfer from Magnetic to Mechanical Reference for LCLS Undulator Fiducialization

Fiducialization of the LCLS undulators will be based on magnetic measurements by Hall probe. Pointed magnets, proposed by I.Vasserman for quadrupole lens fiducialization will be used as an intermediate reference. A prototype of the pointed magnet fixture has been made and tested. In this note we will describe a procedure for measuring the position of the center of the Hall probe sensitive area with respect to the undulator fiducial marks. The pointed magnet calibration procedure, a two-point algorithm for locating the magnetic center of the fixture, and test results are presented.

43 PARTICLE ACCELERATORS↗