Search NASA⌕ Search

SEARCH · Search NASA

Results for “reliability data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Reflectance of vegetation, soil, and water

The author has identified the following significant results. Bands 4, 5, and 7 and 5, 6, and 7 were best for distinguishing among crop and soil categories in ERTS-1 SCENES 1182-16322 (1-21-73) and 1308-16323 (5-21-73) respectively. Chlorotic sorghum areas 2.8 acres or larger in size were identified on a computer printout of band 5 data. Reflectance of crop residues was more often different from bare soil in band 4 than in bands 5, 6, and 7. Simultaneously acquired aircraft and spacecraft MSS data indicated that spacecraft surveys are as reliable as aircraft surveys. ERTS-1 data were successfully used to estimate acreage of citrus, cotton, and sorghum as well as idle crop land.

Wiegand, C. L.↗

Space Shuttle Main Engine (SSME) Options for the Future Shuttle

The main engines for the Future Shuttle will focus on improved safety and operability. Performance enhancements may also be required for vehicle safety purposes to achieve more desirable abort scenarios. This paper discusses the potential improvements that will be considered for implementation into the Future Shuttle. Integrated engine and vehicle health management systems will achieve additional system-level reliability improvements over those currently in development. Advanced instrumentation for detecting leaks, analyzing component wear and degradation, and providing sophisticated operational data will be used for reliable engine control and scheduling maintenance operations. A new nozzle and main combustion chamber (MCC) will reduce failure probability by 50% and allow for higher thrust capability without requiring the entire engine to be redesigned. Turbopump improvements may range from minor component improvements to using 3rd-generation pumps built on the advanced concepts demonstrated by the Integrated Powerhead Development (IPD) program and the Space Launch Initiative (SLI) prototype engines.The main engines for the Future Shuttle will focus on improved safety and operability. Performance enhancements may also be required for vehicle safety purposes to achieve more desirable abort scenarios. This paper discusses the potential improvements that will be considered for implementation into the Future Shuttle. Integrated engine and vehicle health management systems will achieve additional system-level reliability improvements over those currently in development. Advanced instrumentation for detecting leaks, analyzing component wear and degradation, and providing sophisticated operational data will be used for reliable engine control and scheduling maintenance operations. A new nozzle and main combustion chamber (MCC) will reduce failure probability by 50% and allow for higher thrust capability without requiring the entire engine to be redesigned. Turbopump improvements may range from minor component improvements to using 3rd-generation pumps built on the advanced concepts demonstrated by the Integrated Powerhead Development (IPD) program and the Space Launch Initiative (SLI) prototype engines.

Jue, Fred↗

Conditioning of MVM '73 radio-tracking data

An extensive effort was undertaken to edit Mariner 10 radiometric tracking data. Interactive computer graphics were used for the first time by an interplanetary mission to detect blunder points and spurious signatures in the data. Interactive graphics improved the former process time by a factor of 10 to 20, while increasing reliability. S/X dual Doppler data was used for the first time to calibrate charged particles in the tracking medium. Application of the charged particle calibrations decreased the orbit determination error for a short data arc following the 16 March 1974 maneuver by about 80%. A new model was developed to calibrate the earth's troposphere with seasonal adjustments. The new model has a 2% accuracy and is 5 times better than the old model.

Koch, R. E.↗

Experience gained from computer processing of physical experimental data during the restoration of measured values

The processing stage in which the restored values of the physical parameters are received is described. The following main steps are discussed: estimation of the state of the telemetry data, processing of the calibration data, and determination of the errors in the data; data decommutation and analysis of the structure of measurement cycles for each instrument; decoding, estimates of the reliability of the restored data, and their agreement with the models adopted for the measurement process; and analysis of errors due to deterministic and random factors. A block diagram of the method is presented.

Mamotko, Z. N.↗

Fail-over file transfer process

The present invention provides a fail-over file transfer process to handle data file transfer when the transfer is unsuccessful in order to avoid unnecessary network congestion and enhance reliability in an automated data file transfer system. If a file cannot be delivered after attempting to send the file to a receiver up to a preset number of times, and the receiver has indicated the availability of other backup receiving locations, then the file delivery is automatically attempted to one of the backup receiving locations up to the preset number of times. Failure of the file transfer to one of the backup receiving locations results in a failure notification being sent to the receiver, and the receiver may retrieve the file from the location indicated in the failure notification when ready.

Semancik, Susan K.↗

Achieving Lights-Out Operation of SMAP Using Ground Data System Automation

The approach used in the SMAP ground data system to provide reliable, automated capabilities to conduct unattended operations has been presented. The impacts of automation on the ground data system architecture were discussed, including the three major automation patterns identified for SMAP and how these patterns address the operations use cases. The architecture and approaches used by SMAP will set the baseline for future JPL Earth Science missions.

Soil Moisture Active Passive (SMAP)↗

Measuring the effects of distributed database models on transaction availability measures

Data distribution, data replication, and system reliability are key factors in determining the availability measures for transactions in distributed database systems. In order to simplify the evaluation of these measures, database designers and researchers tend to make unrealistic assumptions about these factors. Here, the effect of such assumptions on the computational complexity and accuracy of such evaluations is investigated. A database system is represented with five parameters related to the above factors. Probabilistic analysis is employed to evaluate the availability of read-one and read-write transactions. Both the read-one/write-all and the majority-read/majority-write replication control policies are considered. It is concluded that transaction availability is more sensitive to variations in degrees of replication, less sensitive to data distribution, and insensitive to reliability variations in a heterogeneous system. The computational complexity of the evaluations is found to be mainly determined by the chosen distributed database model, while the accuracy of the results are not so much dependent on the models.

Mukkamala, Ravi↗

Reliability of the Danish Aerospace Corporation Portable Pulmonary Function System

Metabolic gas analysis is a critical component of investigations that measure cardio-pulmonary exercise responses during and after long-duration spaceflight. The primary purpose of the current study was to determine the reliability and intra-subject repeatability of a metabolic gas analysis device, the Portable Pulmonary Function System (PPFS), designed for use on the International Space Station (ISS). The second objective of this study was to directly compare PPFS measurements of expired oxygen and carbon dioxide (FEO2 and FECO2) to values obtained from a well-validated clinical metabolic gas analysis system (ParvoMedics TrueOne (c) [PM]). Eight subjects performed four peak cycle tests to maximal exertion. The first test was used to prescribe work rates for the subsequent test sessions. Metabolic gas analysis for this test was performed by the PM, but samples of FEO2 and FECO2 also were simultaneously collected for analysis by the PPFS. Subjects then performed three additional peak cycle tests, consisting of three 5-min stages designed to elicit 25%, 50%, and 75% maximal oxygen consumption (VO2max) followed by stepwise increases of 25 W/min until subjects reached volitional exhaustion. Metabolic gas analysis was performed using the PPFS for these tests. Intraclass correlation coefficients (ICC), within-subject standard deviations (WS SD), and coefficients of variation (CV%) were calculated for the repeated exercise tests. Mixed model regression analysis was used to compare paired FEO2 and FECO2 values obtained from the PPFS and the PM during the initial test. The ICC values for oxygen consumption (VO2), carbon dioxide production (VCO2), and ventilation (VE) indicate that the PPFS is highly reliable (0.79 to 0.99) for all exercise levels tested; however, ICCs for respiratory exchange ratio (RER) were low ( 0.11 - 0.51), indicating poor agreement between trials during submaximal and maximal exercise. Overall, CVs ranged from 1.6% to 6.7% for all measurements, a finding consistent with reported values that were obtained using other metabolic gas analysis techniques. The PPFS and PM produced comparable FEO2 data; however, there was less agreement between measures of FECO2 obtained from the two devices, particularly at lower CO2 concentrations. The PPFS appears, in practically all respects, to yield highly reliable metabolic gas analysis data. Lower reliability of RER measurements reported in the literature and likely is not a function of the PPFS device. Further examination of PPFS CO2 data is warranted to better understand the limitations of these PPFS measurements. Overall, the PPFS when used for repeated measures of cardio-pulmonary exercise should provide accurate and reliable data for studies of human adaptation to spaceflight.

Portable Pulmonary Function System (PPFS)↗

Results of software error-data experiments

In order to evaluate existing software reliability models and proposed modeling approaches, a search was conducted for data on the software failure process. This search revealed that the data necessary for this evaluation were not available. As a result, a research effort was initiated by NASA to generate data on which to base the development of credible methods for assessing the reliability of software targeted for flight-crucial applications. Two sets of software error-data experiments were conducted by different research groups. The results of the experiments were consistent: errors caused by different faults in a program occurred at widely varying rates; program failure rates exhibited a log-linear trend with respect to the number of faults corrected; some faults were found to interact in either concealing or revealing ways; and contiguous regions of the input space which cause a program to generate errors, called error crystals, were found and characterized for some faults. Collectively, these experiments have produced information on software failure which must be accounted for in software reliability modeling approaches.

Finelli, George B.↗

Thermodynamics of Silicon-Hydroxide Formation in H2O Containing Atmospheres

The formation of volatile silicon-hydroxide species from SiO2 in water containing atmospheres has been identified as a potentially important mode of degradation of Si-based ceramics. Availability of thermodynamic data for these species is a major problem. This study is part of an ongoing effort to obtain reliable, experimentally determined thermodynamic data for these species. The transpiration method was used to measure the pressure of Si-containing vapor in equilibrium with SiO2 (cristobalite) and Ar + H2O(g) with various mole fractions of water vapor, X(sub H2O), at temperatures ranging from 1000 to 1780 K. Enthalpies and entropies for the reaction, SiO2(s) + 2H2O(g) = Si(OH)4(g), were obtained, at X(sub H2O) = 0.15 and 0.37, from the variation of lnK with 1/T according to the 'second law method'. The following data were obtained: delta(H)deg = 52.9 +/- 3.7 kJ/mole and delta(S)deg = -68.6 +/- 2.5 J/mole K at an average temperature of 1550 K, and delta(H)deg = 52.5+/-2.0 kJ/mole and delta(S)deg= -69.7 +/- 1.5 J/moleK at an average temperature of 1384 K, for X(sub H2O)= 0.15 and 0.37, respectively. These data agree with results from the literature obtained at an average temperature of 1600 K, and strongly suggest Si(OH)4(g) is the dominant vapor species. Contradictory results were obtained with the determination of the dependence of Si-containing vapor pressure on the partial pressure of water vapor at 1187 and 1722 K. These results suggested the Si-containing vapor could be a mixture of Si(OH)4 + SiO(OH)2. Further pressure dependent studies are in progress to resolve these issues.

Copland, Evan↗

An Evaluation of Flash Cells Used in Critical Applications

Due to the common use of Flash technology in many commercial and industrial Programmable Logic Devices (PLDs) such as FPGAs and mixed-signal microcontrollers, flash technology is being utilized in fuzed munition applications. This presents a long-term reliability issue for both DoD and NASA safety- and mission-critical applications. A thorough understanding of the data retention failure modes and statistics associated with Flash data retention is of vital concern to the fuze safety community. A key retention parameter for a flash cell is the threshold voltage (VTH), which is an indirect indicator of the amount of charge stored on the cells floating gate. Initial test results based on a study of charge loss in flash cells in an FPGA device is presented. Statistical data taken from a small sample set indicates quantifiable charge loss for devices stored at both room temperature and 150 C. Initial evaluation of the distribution of threshold voltage in a large sample set (800 devices) is presented. The magnitude of charge loss from exposure to electrostatic discharge and electromagnetic fields is measured and presented. Simulated data (and measured data as available) resultant from harsh-environment testing (neutron, heavy ion, EMP) is presented.

data retention↗

An Evaluation of Flash Cells Used in Critical Applications

Due to the common use of Flash technology in many commercial and industrial Programmable Logic Devices (PLDs) such as FPGAs and mixed-signal microcontrollers, flash technology is being utilized in fuzed munition applications. This presents a long-term reliability issue for both DoD and NASA safety- and mission-critical applications. A thorough understanding of the data retention failure modes and statistics associated with Flash data retention is of vital concern to the fuze safety community. A key retention parameter for a flash cell is the threshold voltage (VTH), which is an indirect indicator of the amount of charge stored on the cells floating gate. Initial test results based on a study of charge loss in flash cells in an FPGA device is presented. Statistical data taken from a small sample set indicates quantifiable charge loss for devices stored at both room temperature and 150 C. Initial evaluation of the distribution of threshold voltage in a large sample set (800 devices) is presented. The magnitude of charge loss from exposure to electrostatic discharge and electromagnetic fields is measured and presented. Simulated data (and measured data as available) resultant from harsh-environment testing (neutron, heavy ion, EMP) is presented.

Data Retention↗

Database Design Strategies for Coordinated Simulation and Testing in Additive Manufacturing

The qualification and certification (Q&C) process presents a significant challenge for widespread adoption of additive manufacturing (AM) materials and processes for aerospace applications. A relational database framework will be presented as a tool for data curation of coordinated experimental and computational materials modeling research activities. A comparison of relational and hierarchical data structures in this domain will be emphasized through the evolution of a database design strategy. This framework’s mission is to support the advancement of computational materials-informed Q&C by providing the necessary data infrastructure to trace reliability and reproducibility measures through unified AM materials simulation and experimental testing. FAIR (findable, accessible, interoperable, and reusable) data will be highlighted as a necessary precursor for automation of specific actions, which ultimately reduces the time and expense burden for Q&C. The discussion will be mostly limited to back-end design elements, though a few front-end user experience examples will also be shared.

Qualification↗

The automated strength-aeroelastic design of aerospace structures program

An ongoing program whose goal is to develop an automated procedure that can assist in the preliminary design of aircraft and space structures is described. The approach and capabilities that are to be included in the final procedures are descussed. By using proven engineering software as a basis for the project, a reliable and interdisciplinary procedure is developed. The use of a control language for module sequencing and execution permits efficient development of the procedure and gives the user significant flexibility in altering or enhancing the procedure. The data base system provides reliable and efficient access to the large amounts of interrelated data required in an enterprise of this sort. In addition, the data base allows interfacing with existing pre- and post-processors in an almost trivial manner. Altogether, the procedure promises to be of considerable utility to preliminary structural design teams.

Johnson, E. H.↗

Medical Signal-Conditioning and Data-Interface System

A general-purpose portable, wearable electronic signal-conditioning and data-interface system is being developed for medical applications. The system can acquire multiple physiological signals (e.g., electrocardiographic, electroencephalographic, and electromyographic signals) from sensors on the wearer s body, digitize those signals that are received in analog form, preprocess the resulting data, and transmit the data to one or more remote location(s) via a radiocommunication link and/or the Internet. The system includes a computer running data-object-oriented software that can be programmed to configure the system to accept almost any analog or digital input signals from medical devices. The computing hardware and software implement a general-purpose data-routing-and-encapsulation architecture that supports tagging of input data and routing the data in a standardized way through the Internet and other modern packet-switching networks to one or more computer(s) for review by physicians. The architecture supports multiple-site buffering of data for redundancy and reliability, and supports both real-time and slower-than-real-time collection, routing, and viewing of signal data. Routing and viewing stations support insertion of automated analysis routines to aid in encoding, analysis, viewing, and diagnosis.

Braun, Jeffrey↗

Poisson vs. Gaussian statistics for sparse X-ray data: Application to the soft X-ray spectrometer

Reliable results when fitting X-ray data require proper consideration of the statistics involved. We probe the impact of Gaussian versus Poisson statistics at low count levels using both the standard χ^(2) method and maximum likelihood based on Poisson (C) statistics. The difference is studied and quantified through simulated spectra with known properties. We then test the results through analysis of Mn Kα calibration data taken with the flight spare microcalorimeter for the Hitomi soft X-ray spectrometer. Through comparison with simulations, our results show that the χ^(2) method tends to give overly optimistic estimates of the detector energy resolution, in particular when there are few counts. Given an energy resolution of ∼5 eV and a line with about 100 photons, the line width becomes ∼10% lower in the χ^(2) method than in Poisson statistics. This is a consequence of the uncertainties being dominated by counting statistics, and therefore highlights the need to choose the appropriate fit statistic.

Shinya Yamada↗

A Demonstration that Correcting for Completeness and Reliability Is Critical for Robust Occurrence Rates

A measurement of planetary occurrence rates based on a planet catalog should be robust against details of how initial detections were classified as planets or false positives. This is accomplished by supplying the catalog’s rate of missed planets (completeness) and rate of non-planets incorrectly called planets (reliability). The final Kepler data release (DR25) includes products that can be used with the DR25 planet candidate catalog to correct for completeness and reliability in occurrence rate estimates. This is made possible by the Kepler Robovetter, which algorithmically and uniformly selects planets based on a variety of metrics and thresholds. Completeness, reliability, and occurrence rates potentially depend on these Robovetter thresholds. We study the impact of varying these vetting thresholds using the techniques of Bryson et al. 2019 (arXiv:1906.03575). We explore sets of thresholds that result in more or fewer planets (trading off completeness for reliability), as well as thresholds tuned to pass DR25 false positives identified as possible planets by the Kepler False Positive Working Group. We find that when correcting only for completeness, and not reliability, the resulting occurrence rates have a strong dependence on these threshold sets. For example, the value of SAG13 eta-Earth varies by over a factor of 4 when not corrected for reliability. However, when correcting for both completeness and reliability, occurrence rates using our threshold sets are statistically indistinguishable, with differences being well inside 1-sigma error bars. We present occurrence rates integrated over several period-radius ranges. For example, SAG13 eta-Earth is consistent with 0.127 (+0.094)(-0.054) (from Bryson et al. 2019) for all the Robovetter threshold sets. This result emphasizes the importance of correcting occurrence rates for both completeness and reliability. This suggests that inconsistent completeness and reliability correction may be a significant contributor to the large variation of occurrence rates in recent literature. We plan to make the Robovetter results for our threshold sets available, and encourage the community to use them to examine whether other occurrence rate methods yield similarly robust results.

Bryson, S.↗

Lessons Learned from Particulate Characterization Laboratory Anomalies

The White Sands Test Facility chemistry laboratory provides quality control for cleanroom operations including cleanliness verification of aerospace hardware by particulate counts and non-volatile residue determinations, particulate counts for liquid hypergolic propellants, gaseous helium and nitrogen propellant pressurizing agents used for ground support equipment and flight test article valve actuation, gaseous oxygen primarily used for component testing, and deionized water for refurbished propellant hardware flushing. Cleanliness verification includes particulate counts and non-volatile residue determinations to industry standard, NASA, and program specifications and levels. Particulate counts are typically to customer-specified specifications and levels including JPR 5322.1H (2016) Levels 50 and 100, Orion (MPCV 70156. Revision H (2018)) Level 100, RPTSTD-8070-0001 Revision 3 (2022), and IEST-STD-CC1246E (2013) Levels 50 and 100. The laboratory issues high pressure filter holders containing membrane filters to test operations personnel, who collect samples by flowing the required volumes of fluid through the filter holder, and the filter holder is returned to the lab for counting. A passing particulate count is required before testing may proceed. Rapid data reduction and issuing of reports indicating a pass or fail of the particulate specification are required. Corrective action and resampling invariably occurs if a sample fails. Consequently, the laboratory must maintain the highest degree of reliability to facilitate quality data used to decide if testing may proceed. Experience and continual improvements have enabled reliability. However, anomalies attributed to lab processes and hardware including filter holders, membranes, and Petri dishes have been encountered. This paper presents a summary of problems, solutions, successes, and lessons learned from particle counting experience for over 35 years.

Lessons Learned↗