Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Nanodroplet processing platform for deep and quantitative proteome profiling of 10–100 mammalian cells

Nanoscale or single cell technologies are critical for biomedical applications. However, current mass spectrometry (MS)-based proteomic approaches require samples comprising a minimum of thousands of cells to provide in-depth profiling. Here, we report the development of a nanoPOTS (Nanodroplet Processing in One pot for Trace Samples) platform as a major advance in overall sensitivity. NanoPOTS dramatically enhances the efficiency and recovery of sample processing by downscaling processing volumes to <200 nL to minimize surface losses. When combined with ultrasensitive LC-MS, nanoPOTS allows identification of ~1500 to ~3,000 proteins from ~10 to ~140 cells, respectively. By incorporating the Match Between Runs algorithm of MaxQuant, >3000 proteins were consistently identified from as few as 10 cells. Furthermore, we demonstrate robust quantification of ~2400 proteins from single human pancreatic islet thin sections from type 1 diabetic and control donors, illustrating the application of nanoPOTS for spatially resolved proteome measurements from clinical tissues.

Environmental Molecular Sciences Laboratory↗

Analysis Report documenting the Assessment of the Solubility of Lead, EDTA and other Organic Ligands in non-Sulfide systems performed under TP 08-02 and under TP 20-01

The objective of this report is to accept or reject the hypothesis that the experiments conducted under TP 08-02 Revision 0 (Ismail et al., 2008) were affected by CO 2 (g) intrusion and sample contamination. The test of the hypothesis is accomplished by comparing the experimental data collected under the protocols of TP 08-02 Revision O and TP 20-01 Revision O (Kirkes and Zhang, 2020). The protocols of TP 20-01 Revision 0 minimize the possibilities of CO 2 (g) intrusion and sample contamination. The experimental data sets obtained under both TPs will be assessed statistically to see if they are identical or not.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microbiological Methodology in Astrobiology

Searching for life in astromaterials to be delivered from the future missions to extraterrestrial bodies is undoubtedly related to studies of the properties and signatures of living microbial cells and microfossils on Earth. As model terrestrial analogs of Martian polar subsurface layers are often regarded the Antarctic glacier and Earth permafrost habitats where alive microbial cells preserved viability for millennia years due to entering the anabiotic state. For the future findings of viable microorganisms in samples from extraterrestrial objects, it is important to use a combined methodology that includes classical microbiological methods, plating onto nutrient media, direct epifluorescence and electron microscopy examinations, detection of the elemental composition of cells, radiolabeling techniques, PCR and FISH methods. Of great importance is to ensure authenticity of microorganisms (if any in studied samples) and to standardize the protocols used to minimize a risk of external contamination. Although the convincing evidence of extraterrestrial microbial life will may come from the discovery of living cells in astromaterials, biomorphs and microfossils must also be regarded as a target in search of life evidence bearing in mind a scenario that alive microorganisms had not be preserved and underwent mineralization. Under the laboratory conditions, processes that accompanied fossilization of cyanobacteria were reconstructed, and artificially produced cyanobacterial stromatolites resembles by their morphological properties those found in natural Earth habitats. Regarding the vital importance of distinguishing between biogenic and abiogenic signatures and between living and fossil microorganisms in analyzed samples, it is worthwhile to use some previously developed approaches based on electron microscopy examinations and analysis of elemental composition of biomorphs in situ and comparison with the analogous data obtained for laboratory microbial cultures and fossilized microorganisms. This communication will be focused on the analysis of our experience in working with ancient microorganisms and fossils and discussion of some issues that are crucial for development of the program for future finding of extraterrestrial life and its evidence.

Abyzov, S. S.↗

A test cassette for x-ray-exposure experiments at the National Ignition Facility

We present the design and operation of a test cassette for exposure of samples to radiation environments at the National Ignition Facility. The cassette provides options for square and round samples and exposure areas; the cassette provides for multiple levels of filtration on a single sample, which allows dynamic range in experiments. The samples had normal lines of sight to the x-ray source in order to have uniform x-ray illumination. The incident x-radiation onto the samples was determined by the choice of filter thicknesses and materials. The samples were held at precise locations, accurate to within a few hundred microns, in the target chamber in order to have a known fluence incident. In the cassette, the samples were held in place in such a way that a minimal ''line contact'' allows them to have the maximal mechanical response to the x-ray load. We present postshot images of the debris found on films used for filters, and pre- and postexposure specimens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parameterization Strategies for Intermolecular Potentials for Predicting Trajectory-Based Collision Parameters

The accuracy of separable strategies for constructing full-dimensional potential energy surfaces for collisional energy transfer and collision rate calculations is studied systematically for three alcohols (A = methanol, ethanol, and butanol) and three bath gases (M = Ar, N 2 , and H 2 O). The fitting efficiency (defined as the number of ab initio data required to achieve parametrizations of a desired accuracy) is quantified for both pairwise (Buckingham or "exp6") and nonpairwise (permutationally invariant polynomials, PIPs, of Morse variables) functional forms, for four sampling strategies, and as a function of the complexity and anisotropy of the interaction potential. We find that convergence with respect to the number of sampled ab initio data is largely independent of the choice of functional form but instead varies nearly linearly with the number of adjustable parameters and depends strongly on the sampling strategy. Specifically, the use of biased Sobol quasirandom sampling is similar to 7X more efficient than using unbiased pseudorandom sampling, on average, requiring just similar to 3 computed ab initio energies per adjustable fitting parameter. The pairwise exp6 functional form is shown to provide accurate and transferable parametrizations for M = Ar but is unable to accurately describe alcohol interactions with M = N 2 and H 2 O. The nonpairwise PIP functional form, which is systematically improvable, can produce separable parametrizations with arbitrarily small fitting errors. However, these can suffer from overfitting, which is demonstrated using dynamics calculations of collision parameters for a large number of exp6 and PIP parametrizations. The tests described here validate a robust strategy for automatically generating A + M potential energy surfaces with minimal human intervention, including a quantifiable out of sample metric for judging the accuracy of the fitted surface. We further analyze this set of automatically generated potential energy surfaces to identify areas where more sophisticated fitting strategies may be desired, including pruning of the PIP expansions for large systems and improved sampling strategies more closely coupled with the description of the functional form.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stacking caustic masses from galaxy clusters

Ongoing and future spectroscopic surveys will measure numerous galaxy redshifts within tens of thousands of galaxy clusters. However, the sampling within these clusters will be low, 15 1000 galaxies per ensemble phase space, the escape-velocity edge becomes readily identifiable and the presence of interloping galaxies is minimized. We develop and test an algorithm to trace the projected phase-space surface directly, which results in minimally biased dynamical mass estimates. We then quantify how binning and sampling affect the phase-space-based mass estimates when using an observational proxy that incorporates realistic mass scatter, like richness, and find the added uncertainty in the binning procedure has minimal influence on the resulting bias and scatter of the stacked mass estimates.

79 ASTRONOMY AND ASTROPHYSICS↗

ODIN: Spectroscopic Validation of Lyα-emitting Galaxy Samples with DESI

The One-hundred-deg$^{2}$ DECam Imaging in Narrowbands (ODIN) survey is conducting the widest-field deep narrowband (NB) imaging of the equatorial and southern skies. ODIN uses three custom-built NB filters that sample Lyα-emitting galaxies (LAEs) within thin cosmic slices centered at z = 2.4, 3.1, and 4.5. In this work, we utilize extensive DESI spectroscopy of ODIN-selected galaxies in the COSMOS and XMM-LSS fields to validate our LAE selection. Exposures of 2-4 hr with DESI yielded redshift confirmation of 3075 ODIN LAE candidates with NB magnitudes brighter than 26 mag. Restricting to objects that yield high-confidence redshifts, the confirmation rates are (93%, 96%, 92%) at z = (2.4, 3.1, 4.5). The primary contaminants consist of active galactic nuclei at the expected Lyα-redshift range and lower redshifts (C iv , C iii ]), with the remainder being star-forming galaxies ([O ii ] and [O iii ]). We find minimal contamination from [O ii ] emitters in our sample (≲1%), implying that our rest-frame equivalent width (REW) > 20 Å NB excess photometry requirement is sufficient to remove them.

Pinarski, Ethan [Purdue U., West Lafayette] (ORCID↗

Non-destructive Quantitative Phase Analysis and Microstructural Characterization of Zirconium Coated U-10Mo Fuel Foils via Neutron Diffraction

This report uses neutron diffraction to investigate the crystal phase composition of uranium-molybdenum alloy foils (U-10Mo) for the CONVERT MP-1 Reactor Conversion Project, and determines the effect on alpha-uranium contamination following the deposition of a Zr metal diffusion layer by various methods: plasma spray deposition of Zr powders at LANL and hot co-rolling with Zr foils at BWXT. In summary, there is minimal decomposition of the gamma phase U-10Mo foil to alpha phase contamination following both plasma spraying and hot co-rolling. The average unit cell volume, i.e. lattice spacing, of the Zr layer can be mathematically extracted from the diffraction data; co-rolled Zr matches well with literature values of bulk Zr, while plasma sprayed Zr shows a slight increase in the lattice spacing, indicative of interstitial oxygen in the lattice. Neutron diffraction is a beneficial alternative to conventional methods of phase composition, i.e. x ray diffraction (XRD) and destructive metallography. XRD has minimal penetration depth in high atomic number materials, particularly uranium, and can only probe the first few microns of the fuel plate; neutrons pass completely through the foil, allowing for bulk analysis of the foil composition and no issues with addition of cladding layers, as in the final, aluminum-clad reactor fuel plates. Destructive metallography requires skilled technicians, cutting of the foil into small sections, hazardous etching conditions, long polishing and microscopy times, etc.; the neutron diffraction system has an automated sample loader and can fit larger foils, so there is minimal analysis preparation; the total spectrum acquisition time is ~ 1 hour per sample. The neutron diffraction results are limited by spectra refinement/calculation times and the availability of the neutron beam source. In the case of LANSCE at Los Alamos, the beam operates ~50% of the year. Following the lessons learned from these preliminary results, optimizations to the process and analysis can be made, and neutron diffraction can become a viable and efficient technique for gamma/alpha phase composition determination for nuclear fuels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cleaning Genesis Sample Return Canister for Flight: Lessons for Planetary Sample Return

Sample return missions require chemical contamination to be minimized and potential sources of contamination to be documented and preserved for future use. Genesis focused on and successfully accomplished the following: - Early involvement provided input to mission design: a) cleanable materials and cleanable design; b) mission operation parameters to minimize contamination during flight. - Established contamination control authority at a high level and developed knowledge and respect for contamination control across all institutions at the working level. - Provided state-of-the-art spacecraft assembly cleanroom facilities for science canister assembly and function testing. Both particulate and airborne molecular contamination was minimized. - Using ultrapure water, cleaned spacecraft components to a very high level. Stainless steel components were cleaned to carbon monolayer levels (10 (sup 15) carbon atoms per square centimeter). - Established long-term curation facility Lessons learned and areas for improvement, include: - Bare aluminum is not a cleanable surface and should not be used for components requiring extreme levels of cleanliness. The problem is formation of oxides during rigorous cleaning. - Representative coupons of relevant spacecraft components (cut from the same block at the same time with identical surface finish and cleaning history) should be acquired, documented and preserved. Genesis experience suggests that creation of these coupons would be facilitated by specification on the engineering component drawings. - Component handling history is critical for interpretation of analytical results on returned samples. This set of relevant documents is not the same as typical documentation for one-way missions and does include data from several institutions, which need to be unified. Dedicated resources need to be provided for acquiring and archiving appropriate documents in one location with easy access for decades. - Dedicated, knowledgeable contamination control oversight should be provided at sites of fabrication and integration. Numerous excellent Genesis chemists and analytical facilities participated in the contamination oversight; however, additional oversight at fabrication sites would have been helpful.

Allton, J. H.↗

Rapid determination of 226Ra in environmental samples

A new rapid method for the determination of {sup 228}Ra in natural water samples has been developed at the SRNL/EBL (Savannah River National Lab/ Environmental Bioassay Laboratory) that can be used for emergency response or routine samples. While gamma spectrometry can be employed with sufficient detection limits to determine {sup 228}Ra in solid samples (via {sup 228}Ac) , radiochemical methods that employ gas flow proportional counting techniques typically provide lower MDA (Minimal Detectable Activity) levels for the determination of {sup 228}Ra in water samples. Most radiochemical methods for {sup 228}Ra collect and purify {sup 228}Ra and allow for {sup 228}Ac daughter ingrowth for ~36 hours. In this new SRNL/EBL approach, {sup 228}Ac is collected and purified from the water sample without waiting to eliminate this delay. The sample preparation requires only about 4 hours so that {sup 228}Ra assay results on water samples can be achieved in < 6 hours. The method uses a rapid calcium carbonate precipitation enhanced with a small amount of phosphate added to enhance chemical yields (typically >90%), followed by rapid cation exchange removal of calcium. Lead, bismuth, uranium, thorium and protactinium isotopes are also removed by the cation exchange separation. {sup 228}Ac is eluted from the cation resin directly onto a DGA Resin cartridge attached to the bottom of the cation column to purify {sup 228}Ac. DGA Resin also removes lead and bismuth isotopes, along with Sr isotopes and {sup 90}Y. La is used to determine {sup 228}Ac chemical yield via ICP-MS, but {sup 133}Ba can also be used instead if ICP-MS assay is not available. Unlike some older methods, no lead or strontium holdback carriers or continual readjustment of sample pH is required.

54 ENVIRONMENTAL SCIENCES↗

Simulated Irradiation of Samples in HFIR for use as Possible Test Materials in the MPEX (Material Plasma Exposure Experiment) Facility

The importance of Plasma Material Interaction (PMI) is a major concern in fusion reactor design and analysis. The Material-Plasma Exposure eXperiment (MPEX) facility will explore PMI under fusion reactor plasma conditions. Samples with accumulated displacements per atom (DPA) damage produced by irradiations in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) will be studied in the MPEX facility. The project presented in this paper involved performing assessments of the induced radioactivity and resulting radiation fields of a variety of potential fusion reactor materials. The scientific code packages MCNP and SCALE were used to simulate irradiation of the samples in HFIR; generation and depletion of nuclides in the material and the subsequent composition, activity levels, gamma radiation fields, and resultant dose rates as a function of cooling time. These state-of-the-art simulation methods were used in addressing the challenge of the MPEX project to minimize the radioactive inventory in the preparation of the samples for inclusion in the MPEX facility.

Ellis, Ronald James↗

Manufacturing Dissolvable Alloy Components using ShAPE: A Study on Solid Phase Processing of Mg-W Composites and WJ11 Alloys

Dissolvable alloys and composites are an emerging class of materials that demonstrate tailored sorptivity in corrosive environments. This work explored the viability of solid phase processing (SPP) techniques, namely the shear assisted processing and extrusion (ShAPETM) method, to manufacture dissolvable magnesium composites and alloys components such as rods and tubes. The study also determined the effects of material composition and manufacturing process conditions on material microstructures developed during SPP and the resulting performance of the components. Explicit properties of interest included ultimate tensile strength, ultimate compressive strength, and yield strength. The application fields of interest for dissolvable alloys were identified as oil-and-gas operations and biomedical implants. Accordingly, PNNL collaborated with industrial and academia partners, Fortek Industries, Houston and University of Pittsburgh, during the course of this project for material and ShAPE process development. PNNL determined the viability of the using ShAPE to process the custom-designed materials provided by the project partners. This was done by identifying process parameters such as tool rotation rate, tool plunge rate, and process cooling optimal for manufacturing components with consolidated microstructures. Subsequently, PNNL also performed microstructural characterization on unprocessed and processed samples and mechanical property testing. One of the major findings from this work is that ShAPE was able to manufacture dissolvable magnesium composite and alloy rods and tubes with consolidated homogeneous microstructures and minimal macroscale defects on component surfaces. It was observed that samples processed via ShAPE demonstrated an average grain size < 2 - 5 µm, which was markedly lower than that of the precursors with 8 – 13 µm grains. Results showed that the ShAPE synthesized dissolvable magnesium composite and alloy strength was on par with or better than those components that were manufactured using traditional manufacturing processes such as forging and extrusion. It is noteworthy that the ShAPE samples were made with considerably lower number of process steps.

36 MATERIALS SCIENCE↗

Center for Isotope Cosmochemistry and Geochronology at NASA Johnson Space Center

Ten years in the making the Center for Isotope Cosmochemistry and Geochronology (CICG) at NASA Johnson Space Center is designed to be a cooperative analytical facility where novel techniques are developed and performed. Our team works collaboratively to operate this integrated lab suite comprising sample preparation, metal-free clean chemistry, and mass spectrometers to measure a wide variety of elements and isotopes in astromaterials. Contamination control is enacted throughout by a positive pressure cascade of HEPA filtered air, weekly surface cleaning and particle counting. Astromaterials processing is performed with application-specific mortar and pestles, heavy liquid separation, a Frantz magnetic separator, as well as hand-picking using optical microscopes in laminar flow boxes. Microsampling is also carried out using a New Wave MicroMill. Elements for isotopic analysis are isolated from acid-digested samples using ion-exchange chromatography. Cross-contamination is minimized with dedicated laminar flow boxes and labware for different purification protocols. Instrumentation includes a ThermoFisher Element XR inductively coupled plasma mass spectrometer (ICP-MS) for quantification of elemental concentrations in dissolved sample solutions. For in situ analysis, a Teledyne Photon Machines Analyte Excite+ laser ablation system is coupled to the Element XR. The ThermoFisher Triton thermal ionization mass spectrometer (TIMS) is used to measure the isotopic composition of elements such as CA, K, Cr, Rb, Sr, Sm, Nd at high precision in processed samples. For a more diverse range of isotopic analyses, CICG houses a Nu Sapphire 1700 multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS), which is a large geometry instrument with a multi-pole collision cell for interference removal. An Applied Spectra Instruments J200 femto-second laser is planned for install this Fall and will be coupled to the Nu Sapphire 1700. NASA’s Internal Scientist Funding Model (ISFM)supports this facility. Advanced analytical geochemistry techniques are applied to targeted astromaterials to address important problems in planetary sciences, with a longer-term goal of preparing for samples collected and returned by space missions. CICG is open to collaborations on projects that utilize the facility’s unique capabilities and are within its research scope. We are particularly eager to support and share expertise with the next generation of planetary scientists.

Justin I Simon↗

Nano Icy Moons Propellant Harvester

As one of just a few bodies identified in the solar system with a liquid ocean, Europa has become a top priority in the search for life outside of Earth. However, cost estimates for exploring Europa have been prohibitively expensive, with estimates of a NASA Flagship class orbiter and lander approaching $5 billion. ExoTerra's NIMPH offers an affordable solution that can not only land, but return a sample from the surface to Earth. NIMPH combines solar electric propulsion (SEP) technologies being developed for the asteroid redirect mission and microsatellite electronics to reduce the cost of a full sample return mission below $500 million. A key to achieving this order-of-magnitude cost reduction is minimizing the initial mass of the system. The cost of any mission is directly proportional to its mass. By keeping the mission within the constraints of an Atlas V 551 launch vehicle versus an SLS, we can significantly reduce launch costs. To achieve this we reduce the landed mass of the sample return lander, which is the largest multiplier of mission mass, and shrink propellant mass through high efficiency SEP and gravity assists. The NIMPH projects first step in reducing landed mass focuses on development of a micro-In Situ Resource Utilization (micro-ISRU) system. ISRU allows us to minimize landed mass of a sample return mission by converting local ice into propellants. The project reduces the ISRU system to a CubeSat-scale package that weighs just 1.74 kg and consumes just 242 W of power. We estimate that use of this ISRU vs. an identical micro-lander without ISRU reduces fuel mass by 45 kg. As the dry mass of the lander grows for larger missions, these savings scale exponentially. Taking full advantage of the micro-ISRU system requires the development of a micro-liquid oxygen-liquid hydrogen engine. The micro-liquid oxygen-liquid hydrogen engine is tailored for the mission by scaling it to match the scale of the micro-lander and the low gravity of the target moon. We also tailor the engine for a near stoichiometric mixture ratio of 7.5. Most high-performance liquid oxygen-liquid hydrogen engines inject extra liquid hydrogen to lower the average molecular weight of the exhaust, which improves specific impulse. However, this extra liquid hydroden requires additional power and processing time on the surface for the ISRU to create. This increases mission cost, and on missions within high radiation environments such as Europa, increases radiation shielding mass. The resulting engine weighs just 1.36 kg and produces 71.5 newton of thrust at 364 s specific impulse. Finally, the mission reduces landed mass by taking advantage of the SEP modules solar power to beam energy to the surface using a collimated laser. This allows us to replace an 45 kg MMRTG with a 2.5 kg resonant array. By using the combination of ISRU, a liquid oxygen-liquid hydrogen engine, and beamed power, we reduce the initial mass of the lander to just 51.5 kg. When combined with an SEP module to ferry the lander to Europa the initial mission mass is just 6397 kg - low enough to be placed on an Earth escape trajectory using an Atlas V 551 launch vehicle. By comparison, we estimate a duplicate lander using an MMRTG and semi-storable propellants such as liquid oxygen-methane would result in an order of magnitude increase in initial lander mass to 445 kg. Attempting to perform the trajectory with a 450 s liquid oxygen-liquid hydrogen engine would increase initial mass to approximately 135,000 kg. Using an Atlas V 1 U.S. Dollar per kg rate to Earth escape value of $27.7k per kg, just the launch savings are over $3.5 billion.

liquid↗

Lunar carbon chemistry - Relations to and implications for terrestrial organic geochemistry.

Survey of the various ways in which studies of lunar carbon chemistry have beneficially affected terrestrial organic geochemistry. A lunar organic gas-analysis operating system is cited as the most important instrumental development in relation to terrestrial organic geochemistry. Improved methods of analysis and handling of organic samples are cited as another benefit derived from studies of lunar carbon chemistry. The problem of controlling contamination and minimizing organic vapors is considered, as well as the possibility of analyzing terrestrial samples by the techniques developed for lunar samples. A need for new methods of analyzing carbonaceous material which is insoluble in organic solvents is indicated.

Eglinton, G.↗

Deuterium plasma induced preferential erosion in ultra-high temperature ceramics TiB 2 and ZrB 2 *

Abstract Steady-state deuterium plasma exposures were performed on ultra-high temperature ceramics titanium diboride (TiB 2 ) and zirconium diboride (ZrB 2 ) using the PISCES-RF linear plasma device (LPD) as early screening for first wall, plasma-facing applications. Deuterium plasma exposures were performed using 40 eV ion energies at 240, 525, and 800 °C sample temperatures and 90 eV ion energies at 240 °C sample temperatures to analyze TiB 2 and ZrB 2 surface morphology and chemistry evolution behavior. Post-plasma exposure chemistry characterization of the near surface ( < 50 nm) region of the samples all show transition metal enrichment, indicating boron preferential erosion. Transition metal to boron fractions vary with plasma exposure temperature under the 40 eV ion energy; metal enrichment is maximized at 800 °C and then minimized at 525 °C. SEM micrographs of all plasma exposed sample surfaces show no significant or noticeable plasma induced damage from cracking or blistering.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improving Computational Efficiency of Prognostics Algorithms in Resource-Constrained Settings

The field of prognostics and health management provides quantitative methods for monitoring and predicting the health of physical systems. Prognostics algorithms are useful in that they can be employed to assess the current state of a system, propagate the system state throughout time, and predict potential anomalies or failures that may occur. However, effective prognosis can be challenging to achieve in resource-constrained settings due to computational limitations and high computational latency, leading to obsolete predictions. Thus, computationally efficient and accurate algorithms are necessary for some prognostics applications. In this work, we implement three new algorithmic approaches to prediction (sampling methods, variable prediction time step, variable prediction sample size) with the goal of improving computational efficiency while minimizing decrease in model accuracy. To quantitatively analyze our results, we examine a use-case of degradation of a Lithium-ion battery. Notably, through this work it was found that none of the sampling approaches had a significant impact on computational efficiency or model accuracy in predicting EOD of the battery. However, our results show that prediction accuracy is highly dependent on the time step used, and that an appropriate time step can optimize both model accuracy and simulation efficiency. Finally, implementing a variable sample size also affected prediction, and our results show that tuning both the magnitude and timing of the sample size adjustment in an application-specific manner may prove useful in some applications. Taken together, our findings highlight the challenge of performing prognostics in resource-constrained settings, and illustrate the potential of developing new prediction algorithms to improve computational efficiency of prognosis.

Prognostics↗