Search NASA⌕ Search

SEARCH · Search NASA

Results for “software performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Utilization of Hydroturbines in Wastewater Treatment Plants

Wastewater treatment plants (WWTPs) are a significant energy consumer, yet there are several opportunities for implementing on-site power generation systems. Within the treatment process, the high flow rate of effluent is produced and discharged to a nearby water body by gravity. Thus, hydroturbines can be utilized to generate power in such an application due to a difference in elevation and high flow rate. This paper presents a case study of introducing a hydroturbine in a WWTP in Wisconsin and evaluating the power output in addition to determining the energy savings. The WWTP considered in this study has an effluent flow rate of 190 MGD (million gallons per day) and elevation difference of 3 m (10 ft) between the final stage of treatment and the discharge point. Based on the parameters above; hubless rim-drive Kaplan type hydroturbine (RDT) is the optimal choice to be used in such an application. The RDT is designed and optimized by using in-house code. A computational fluid dynamics (CFD) software is applied to evaluate the performance of the proposed model, and the system is simulated through homer software to validate the results generated by the CFD. The expected savings is estimated to be 1564 MWh/yr.

Energy & Fuels↗

Experimental determination of the radial dose distribution in high gradient regions around {sup 192}Ir wires: Comparison of electron paramagnetic resonance imaging, films, and Monte Carlo simulations

Purpose: The experimental determination of doses at proximal distances from radioactive sources is difficult because of the steepness of the dose gradient. The goal of this study was to determine the relative radial dose distribution for a low dose rate {sup 192}Ir wire source using electron paramagnetic resonance imaging (EPRI) and to compare the results to those obtained using Gafchromic EBT film dosimetry and Monte Carlo (MC) simulations. Methods: Lithium formate and ammonium formate were chosen as the EPR dosimetric materials and were used to form cylindrical phantoms. The dose distribution of the stable radiation-induced free radicals in the lithium formate and ammonium formate phantoms was assessed by EPRI. EBT films were also inserted inside in ammonium formate phantoms for comparison. MC simulation was performed using the MCNP4C2 software code. Results: The radical signal in irradiated ammonium formate is contained in a single narrow EPR line, with an EPR peak-to-peak linewidth narrower than that of lithium formate ({approx}0.64 and 1.4 mT, respectively). The spatial resolution of EPR images was enhanced by a factor of 2.3 using ammonium formate compared to lithium formate because its linewidth is about 0.75 mT narrower than that of lithium formate. The EPRI results were consistent to within 1% with those of Gafchromic EBT films and MC simulations at distances from 1.0 to 2.9 mm. The radial dose values obtained by EPRI were about 4% lower at distances from 2.9 to 4.0 mm than those determined by MC simulation and EBT film dosimetry. Conclusions: Ammonium formate is a suitable material under certain conditions for use in brachytherapy dosimetry using EPRI. In this study, the authors demonstrated that the EPRI technique allows the estimation of the relative radial dose distribution at short distances for a {sup 192}Ir wire source.

61 RADIATION PROTECTION AND DOSIMETRY↗

Compartment modeling of dynamic brain PET—The impact of scatter corrections on parameter errors

Purpose: The aim of this study was to investigate the effect of scatter and its correction on kinetic parameters in dynamic brain positron emission tomography (PET) tumor imaging. The 2-tissue compartment model was used, and two different reconstruction methods and two scatter correction (SC) schemes were investigated. Methods: The GATE Monte Carlo (MC) software was used to perform 2 × 15 full PET scan simulations of a voxelized head phantom with inserted tumor regions. The two sets of kinetic parameters of all tissues were chosen to represent the 2-tissue compartment model for the tracer 3′-deoxy-3′-({sup 18}F)fluorothymidine (FLT), and were denoted FLT{sub 1} and FLT{sub 2}. PET data were reconstructed with both 3D filtered back-projection with reprojection (3DRP) and 3D ordered-subset expectation maximization (OSEM). Images including true coincidences with attenuation correction (AC) and true+scattered coincidences with AC and with and without one of two applied SC schemes were reconstructed. Kinetic parameters were estimated by weighted nonlinear least squares fitting of image derived time–activity curves. Calculated parameters were compared to the true input to the MC simulations. Results: The relative parameter biases for scatter-eliminated data were 15%, 16%, 4%, 30%, 9%, and 7% (FLT{sub 1}) and 13%, 6%, 1%, 46%, 12%, and 8% (FLT{sub 2}) for K{sub 1}, k{sub 2}, k{sub 3}, k{sub 4}, V{sub a}, and K{sub i}, respectively. As expected, SC was essential for most parameters since omitting it increased biases by 10 percentage points on average. SC was not found necessary for the estimation of K{sub i} and k{sub 3}, however. There was no significant difference in parameter biases between the two investigated SC schemes or from parameter biases from scatter-eliminated PET data. Furthermore, neither 3DRP nor OSEM yielded the smallest parameter biases consistently although there was a slight favor for 3DRP which produced less biased k{sub 3} and K{sub i} estimates while OSEM resulted in a less biased V{sub a}. The uncertainty in OSEM parameters was about 26% (FLT{sub 1}) and 12% (FLT{sub 2}) larger than for 3DRP although identical postfilters were applied. Conclusions: SC was important for good parameter estimations. Both investigated SC schemes performed equally well on average and properly corrected for the scattered radiation, without introducing further bias. Furthermore, 3DRP was slightly favorable over OSEM in terms of kinetic parameter biases and SDs.

60 APPLIED LIFE SCIENCES↗

TU-AB-202-06: Quantitative Evaluation of Deformable Image Registration in MRI-Guided Adaptive Radiation Therapy

Purpose: To assess the performance of the deformable image registration algorithm used for MRI-guided adaptive radiation therapy using image feature analysis. Methods: MR images were collected from five patients treated on the MRIdian (ViewRay, Inc., Oakwood Village, OH), a three head Cobalt-60 therapy machine with an 0.35 T MR system. The images were acquired immediately prior to treatment with a uniform 1.5 mm resolution. Treatment sites were as follows: head/neck, lung, breast, stomach, and bladder. Deformable image registration was performed using the ViewRay software between the first fraction MRI and the final fraction MRI, and the DICE similarity coefficient (DSC) for the skin contours was reported. The SIFT and Harris feature detection and matching algorithms identified point features in each image separately, then found matching features in the other image. The target registration error (TRE) was defined as the vector distance between matched features on the two image sets. Each deformation was evaluated based on comparison of average TRE and DSC. Results: Image feature analysis produced between 2000–9500 points for evaluation on the patient images. The average (± standard deviation) TRE for all patients was 3.3 mm (±3.1 mm), and the passing rate of TRE<3 mm was 60% on the images. The head/neck patient had the best average TRE (1.9 mm±2.3 mm) and the best passing rate (80%). The lung patient had the worst average TRE (4.8 mm±3.3 mm) and the worst passing rate (37.2%). DSC was not significantly correlated with either TRE (p=0.63) or passing rate (p=0.55). Conclusions: Feature matching provides a quantitative assessment of deformable image registration, with a large number of data points for analysis. The TRE of matched features can be used to evaluate the registration of many objects throughout the volume, whereas DSC mainly provides a measure of gross overlap. We have a research agreement with ViewRay Inc.

60 APPLIED LIFE SCIENCES↗

Study of the distribution profile of iron ions implanted into silicon

Iron ions with energies of 90 and 250 keV and a dose of 10{sup 16} cm{sup –2} are implanted into a silicon single crystal with the (110) orientation. The method of Rutherford backscattering in combination with channeling is used to study the distribution profiles of the introduced impurity and also the profiles of the distribution of radiation-induced defects in the crystal lattice. Experimental data are compared with the results of simulation performed using the TRIM software package. It is shown that, at an energy of 4.6 keV/nucleon, the average projected ranges coincide; however, at an energy of 1.6 keV/nucleon, the difference amounts to 35%. In addition, it is shown that the calculation incorrectly takes into account the dose dependence at energies of 1.6–4.6 keV/nucleon.

36 MATERIALS SCIENCE↗

A Backend-agnostic, Quantum-classical Framework for Simulations of Chemistry in C ++

As quantum computing hardware systems continue to advance, the research and development of performant, scalable, and extensible software architectures, languages, models, and compilers is equally as important to bring this novel coprocessing capability to a diverse group of domain computational scientists. For the field of quantum chemistry, applications and frameworks exist for modeling and simulation tasks that scale on heterogeneous classical architectures, and we envision the need for similar frameworks on heterogeneous quantum-classical platforms. Furthermore, we present the XACC system-level quantum computing framework as a platform for prototyping, developing, and deploying quantum-classical software that specifically targets chemistry applications. We review the fundamental design features in XACC, with special attention to its extensibility and modularity for key quantum programming workflow interfaces and provide an overview of the interfaces most relevant to simulations of chemistry. A series of examples demonstrating some of the state-of-the-art chemistry algorithms currently implemented in XACC are presented, while also illustrating the various APIs that would enable the community to extend, modify, and devise new algorithms and applications in the realm of chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Remark on Algorithm 1012: Computing Projections with Large Datasets

In ACM TOMS Algorithm 1012, the DELAUNAYSPARSE software is given for performing Delaunay interpolation in medium to high dimensions. When extrapolating outside the convex hull of the training set, DELAUNAYSPARSE calls the nonnegative least squares solver DWNNLS to compute projections onto the convex hull. However, DWNNLS and many other available sum-of-squares optimization solvers were not intended for usage with many variable problems, which result from the large training sets that are typical in machine learning applications. Thus, a new PROJECT subroutine is given, based on the highly customizable quadratic program solver BQPD. This solution is shown to be as robust as DELAUNAYSPARSE for projection onto both synthetic and real-world datasets, where other available solvers frequently fail. Although it is intended as an update for DELAUNAYSPARSE, due to the difficulty and prevalence of the problem, this solution is likely to be of external interest as well.

97 MATHEMATICS AND COMPUTING↗

Domi

Domi (Greek for "structure") is a Trilinos package that provides support for multi-dimensional data arrays distributed over multiple processors of a high performance computing system. The software supports data arrays of arbitrary number of dimensions mapped to a multi-dimensional grid of processors. Domi provides local access to the data, as well as the ability to compute global quantities such as norms, maxima and minima. Data arrays can be constructed with boundary and communication padding, necessary for finite difference algorithms, and provides high-level methods for communicating data between processors to update these buffers. The distributed maps and vectors in Domi can be converted to the equivalent data structures in Epetra and Tpetra (both of which assume unstructured data), using view semantics when appropriate, for use with other Trilinos solvers.

Spotz, WilliamF.↗

Blockchain Based Remote Data Integrity Checking Tool v1.0

Computer System Security: The software is used to perform remote data integrity checking without relying on a single third party. In order to remove the trusted third party our tool uses distributed ledger (Blockchain) technology. The ledger is used to store evidences (in the form of hash values). These values are used as an input in the integrity checking process.

Wonjiga, Amir↗

GauXC v0.1.0

GauXC is a modern, modular C++ library for the numerical exchange-correlation (XC) integration required for the Gaussian basis set discretization of Kohn-Sham density functional theory (DFT). The modular nature of GauXC allows for an extensible software design which enables performance portability on an array of CPU and GPU architectures.

Williams-Young, David↗

trueSIG

Sensitivity testing software package with improved performance for small samples.

Sjue, Sky↗

DYNAMIC - The Nonlinear Dynamical Network Simulator v. 0.1

The purpose of the DYNAMIC software system is to perform simulations to validate a new research concept called “Chaotic Logic” which we recently published. The problem to be solved is to simulate certain networks of nonlinearly-interacting dynamical variables, and collect statistics on their behavior, to show that they can reliably perform useful computations. The dynamical trajectories for such networks are computed by time integration of their Hamilton’s equations.

Frank, MichaelP.↗

minervachem

Minervachem is a tool for cheminformatics and machine learning in chemistry. It includes both algorithms from existing literature and algorithms which we have developed. Its features center around two main themes: molecular representations and algorithms, both for molecular machine learning. It provides a scikit-learn transformer interface for molecular featurization and an estimator interface for machine learning algorithms. It also provides visualization tools for explaining machine learning predictions. We aim to continue developing this software to improve its performance and usability and expand its capabilities within the realm of molecular machine learning, cheminformatics, and visualization.

Lubbers, Nicholas↗

CLIP Representation Enhanced Predicate Estimation

This software provides functions to perform visual predicate estimation by leveraging the pre-trained vision-language model CLIP. In addition to training the prediction estimator with a labeled dataset, it also performs performance evaluation and visualization of results.

Jayaraman Thiagarajan, Jayaraman↗

Maritime Battery Electrification Simulator (MariBES) v1

MariBES is a Python-based software designed for calculating emissions and energy consumption in maritime transportation. This software is capable of performing calculations for multiple vessels, facilitating emission analysis at regional, national, and international scales. It also allows for the examination of energy consumption under various resource such as heavy fuel oil, diesel, and battery-electric, enabling the assessment of different decarbonization strategies in the maritime sector. MariBES utilizes public data on ship activities combined with detailed vessel specifications, significantly enhancing the accuracy of its simulations. This approach marks a considerable advancement over previous models that were constrained by limited spatial and temporal resolution. It features a temporal resolution based on 5-minute intervals and a spatial resolution using precise coordinates.

Moon, HeeSeung↗

RetroTide v1.0

RetroTide is a retrobiosynthesis software tool, designed to guide the design of biological pathways to make valuable small molecules. It takes as input a desired small molecule chemical structure, and outputs a design for a polyketide synthase enzyme (PKS) that has the closest possible chemical structure, as accessible by PKS chemistry. It is developed as a Python software library, and internally performs a search of the PKS design space, while simulating the chemicals produced by each design.

Backman, Tyler↗

UAV remote sensing imagery - Miscanthus trials 2020 - Energy Farm - UIUC

Aerial imagery utilized as input in the manuscript "Deep convolutional neural networks exploit high spatial and temporal resolution aerial imagery to predict key traits in miscanthus" . Data was collected over M. Sacchariflorus and Sinensis breeding trials at the Energy Farm, UIUC in 2020. Flights were performed using a DJI M600 mounted with a Micasense Rededge multispectral sensor at 20 m altitude around solar noon. Imagery is available as tif file by field trial and date (10). The post-processing of raw images into orthophoto was performed in Agisoft Metashape software. Each crop surface model and multispectral orthophoto was stacked into an unique raster stack by date and uploaded here. Each raster stack includes 6 layers in the following order: Layer 1 = crop surface model, Layer 2 = Blue, Layer 3 = Green, Layer 4 = Red, Layer 5 = Rededge, and Layer 6 = NIR multispectral bands. Msa raster stacks were resampled to 1.67 cm spatial resolution and Msi raster stacks were resampled to 1.41 cm spatial resolution to ease their integration into further analysis. 'MMDDYYYY' is the date of data collection, 'MSA' is M. Sacchariflorus trial, 'MSI' is Miscanthus Sinensis trial, 'CSM' is crop surface model layer, and 'MULTSP' are the five multispectral bands.

bioenergy↗

Characterization of Soil and Rock Magnetic Properties along Multiple Hillslope Transects at Teller Road Site, Seward Peninsula, Alaska, 2018 and 2023

The magnetometer data was collected in multiple directions across the watershed hillslope at the NGEE Arctic Teller Road site at mile marker 27 (TL_MM27) on the Seward Peninsula, Alaska over multiple years in March 2018 and April 2023. The magnetic data were collected using a Geometrics Inc. G-858 gradiometer and G-857 base station in 2018 and the G-864 gradiometer and G857 base station in 2023. The data was collected (in all instances) by towing the gradiometer behind a snow machine around the watershed with the two sensors in a vertical profile with constant spacing during the continuous survey in that specific year. Magnetic total field measurements were collected by gradiometer and base station, and the data processing was performed in Geometrics MagMap2000 software. The processing steps were limited to removal of data spikes (despiking), reading dropouts, and correction/removal of bad GPS points. All offsets between sensors and GPS are stated within the data files and metadata, alongwith the processed and raw data. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).In this data submission there are two sets of raw magnetic data (.bin and .stn for 2018 and base for 2023; raw rover mag for 2023 is in .csv) inside two .zip files that identify the year the mag data was collected. The data are proprietary format to Geometrics and can be opened and processed with MagMap2000 which can be downloaded for free at Geometrics website. There are also two processed data files *.csv for each year and two metadata files *.csv.

54 ENVIRONMENTAL SCIENCES↗