Search NASA⌕ Search

SEARCH · Search NASA

Results for “solution processability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

An eigenvalue-based method for computing the relaxed pressure in compressible multiphase flow with N phases

The modeling of compressible multiphase flows is a decades-old area of study with many applications across various fields. Many of these application areas use stiff pressure relaxation. This process involves the solution of a nonlinear system with N + 1 equations and N + 1 unknowns, where N is the number of phases. The resolution of this system with general equations of state (EOSs) is difficult. Furthermore, nonlinear systems can admit multiple solutions, and current solution methods do not address this possibility. Very recently, a thermodynamic relaxation method was introduced, which effectively maps a relatively simple predictor equation of state onto a more complex target equation of state. In this context, the target EOSs are the chosen EOSs for the thermodynamic model. Furthermore, this thermodynamic relaxation has the benefit of simplifying the stiff pressure relaxation system of equations. In this article, we show this system reduces to a polynomial of degree N, which can be recast as an eigenvalue problem through the use of the associated companion matrix. We show that although this eigenvalue method is generally less efficient than Newton–Raphson iteration, it does not suffer from convergence issues and finds all N roots of the polynomial. Hence, the method provides a fail-safe for root-finding iterative methods and a way to address the issue of multiple solutions to the nonlinear system of equations in stiff pressure relaxation.

Eigenvalue algorithm↗

Recent advances of two-dimensional material additives in hybrid perovskite solar cells

Perovskite solar cells (PSCs) have become one of the state-of-the-art photovoltaic technologies due to their facile solution-based fabrication processes combined with extremely high photovoltaic performance originating from excellent optoelectronic properties such as strong light absorption, high charge mobility, long free charge carrier diffusion length, and tunable direct bandgap. However, the poor intrinsic stability of hybrid perovskites under environmental stresses including light, heat, and moisture, which is often associated with high defect density in the perovskite, has limited the large-scale commercialization and deployment of PSCs. The use of process additives, which can be included in various subcomponent layers in the PSC, has been identified as one of the effective approaches that can address these issues and improve the photovoltaic performance. Among various additives that have been explored, two-dimensional (2D) materials have emerged recently due to their unique structures and properties that can enhance the photovoltaic performance and device stability by improving perovskite crystallization, defect passivation, and charge transport. In this work, we provide a review of the recent progresses in 2D material additives for improving the PSC performance based on key representative 2D material systems, including graphene and its derivatives, transitional metal dichalcogenides, and black phosphorous, providing a useful guideline for further exploiting unique nanomaterial additives for more efficient and stable PSCs in the near future.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Water dynamics in pristine and porous Ti 3 C 2 T x MXene as probed by quasielastic neutron scattering

MXenes are a novel class of two-dimensional (2D) materials whose applications in energy-storage systems have attracted substantial attention. Still, the rate performance of these materials is often diminished by sheet restacking, which is attenuated via controlled etching in H 2 SO 4 solution. With this process, micropores are formed in MXene sheets that allow transport across 2D layers. As a result, the intercalation and diffusivity of ions are facilitated resulting in improved capacitance retention at high charge-discharge rates. In the present work, we used quasielastic neutron scattering to evaluate the potential changes in water dynamics as a consequence of this mechanism by assessing the behavior of weakly and strongly confined water populations in pristine and porous MXenes. First, we have found that the porous sample accommodates a noticeably higher content of both water populations. Additionally, the fraction of mobile molecules is higher either under strong or weak confinement. Interestingly, regardless of the abundance of weakly confined water in the porous sample, no considerable changes in the dynamical behavior were detected in comparison with the dynamics measured in the pristine material. Finally, for the strongly confined populations of water, our results show that water is able to permeate the micropores introduced by etching and perform unlocalized motions.

36 MATERIALS SCIENCE↗

Isolating Insecurely: A Call to Arms for the Security and Privacy Community During the Time of COVID-19

The privacy question is one that has only begun to be addressed. While on one hand, many of the staunchest privacy advocates have argued for relaxation of privacy controls in order to develop better tests, “back to work” protocols, and vaccines and other treatments, the same advocates point out that any loss of privacy for the public good should be temporary, transparent, necessary, proportionate, and follow a due process. What should solutions look like for data gathering, sharing, use, and disposal; or for protocols requiring strong individual identity verification and validation?

99 GENERAL AND MISCELLANEOUS↗

Group-V Doping Impact on Cd-Rich CdTe Single Crystals Grown by Traveling-Heater Method

Cd-rich CdTe single crystals were grown from Cd solvent in the traveling-heater method (THM) rather than the more common Te solvent used for high-resistivity CdTe. The growth process from Cd solution in terms of the solid-liquid interface shape and group-V doping under Cd-rich condition were investigated. Stable, flat solid-liquid interfaces can be obtained by optimizing THM furnace temperature profile. An apparent doping limit in the 10^16 to 10^17 cm^ -3 range which scales weakly with increasing group-V element concentrations in the Cd-rich CdTe samples were indicated from capacitance-voltage measurement. The two-photon excitation time-resolved photoluminescence revealed a bulk lifetime of 20-40 ns.

14 SOLAR ENERGY↗

Solvent Hold Tank Sample Results for MCU-18-123- 125 (April 2018), MCU-18-135-137 (May 2018), and MCU-18-192-197(June 2018): Quarterly Report

A trend summary of three Solvent Hold Tank (SHT) monthly samples MCU-18-123-125, MCU-18-135- 137, and MCU-18-192-197 are reported. Most of the conclusions are based on the June SHT sample (MCU- 18-192-197). Analyses of the June SHT sample (MCU-18-192-197) indicated that the Modifier (CS-7SB) and the extractant (MaxCalix) concentrations were at the nominal recommended concentrations (169,000 mg/L and 46,400 mg/L respectively). The suppressor ( N,N’,N” –tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has decreased since the April 2018 measurement (Modular Caustic-Side Solvent Extraction Unit or MCU resumed processing radioactive salt solution from May through August 2018) to 1,116 mg/L, well above the minimum recommended concentration (479 mg/L), but below the nominal concentration. The apparent “downwards” trends observed in the TiDG, MaxCalix, Modifier, and gamma measurement are consistent with the start up (and/or proficiency runs) of MCU on May 22, 2018 since these new concentrations are consistent with the concentrations observed when MCU was fully operational in 2016.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent Hold Tank Sample Results for MCU-18-301- 303 (July 2018), MCU-18-357-359-360 (August 2018), and MCU-18-402-410 (September 2018) (Quarterly Report)

A trend summary of three Solvent Hold Tank (SHT) monthly samples; MCU-18-301-302-303, MCU-18- 357-359-360 and MCU-18-402-410 are reported. Most of the conclusions are based on the September SHT sample (MCU-18-402-410). Analyses of the September SHT sample (MCU-18-402-410) indicated that the Modifier (Cs-7SB) and the extractant (MaxCalix) concentrations were below their nominal recommended concentrations (169,000 mg/L and 46,400 mg/L respectively) by 5% and 8% respectively. The suppressor (N,N’,N”–tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has decreased since the April 2018 measurement (Modular Caustic-Side Solvent Extraction Unit or MCU resumed processing radioactive salt solution from May through August 2018) to 241 mg/L, well below the minimum recommended concentration (479 mg/L). The apparent “downwards” trends observed in the TiDG, MaxCalix, and Modifier measurements are consistent with the startup (or Proficiency Runs) of MCU on May 22, 2018; new levels are consistent with the concentrations observed when MCU was fully operational in 2016. This analysis confirms the Isopar™ L addition to the solvent on July 2 and August 9, 2018. This analysis also indicates the solvent did require a trim addition. Based on the current monthly sample, the concentrations of Isopar™ L, MaxCalix, and Modifier are sufficient for continuing operation but are expected to decrease with time. The TiDG concentration was below its recommended level. Periodic characterization and trimming additions to the solvent are recommended. The Semi-Volatile Organic Analysis (SVOA) did not detect any impurities. However, the Fourier Transform Hydrogen Nuclear Magnetic Resonance (FT-HNMR) analysis detected a low concentration of sec-butyl phenol (SBP) at levels of a few ppm. The impurity concentration was highest in the July sample and consistently detected in the August and September samples (but always a few ppm or less). The source of this impurity is due to the degradation of the Modifier. Another impurity observed in the samples was mercury. Based on the September SHT sample, up to 17 ± 3 micrograms of mercury per mL of solvent was detected (the average of the Direct Mercury Analysis (DMA) and X-Ray Fluorescence (XRF) methods). The higher mercury concentration in the solvent (as determined in the last three monthly samples) is possibly due to the higher mercury concentration in Salt Batches 9 and 10 (SB 10 was recently added to Tank 49H in March 2017). The gamma concentration (~2.3E5 dpm/mL) measured in the September SHT samples was consistent with previous values observed when MCU was fully operational (for example, between December 2016 and January 2017) and it was lower than the April SHT measurement. The “dip” in the gamma measurement for the May 2018 SHT sample was due to Isopar™ L addition to MCU during April and May 2018. The laboratory will continue to monitor the quality of the solvent for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Removal Performance Comparisons of Crystalline Silicotitanate Media Batches with Savannah River Site Waste Simulant

The Tank Closure Cesium Removal (TCCR) system uses ion exchange columns filled with Crystalline Silicotitanate (CST) media to process radioactive waste solutions for the removal of Cs- 137. The TCCR project is currently focused on dissolving Savannah River Site (SRS) Tank 10H waste (primarily sodium salt cake solids) within the tank followed by at-tank ion exchange column treatment. Plans are underway to prepare and install a second TCCR unit at SRS. Capacity and particle size differences exist between archived (IE-911) and more recently prepared CST media batches (9120-B and 9140-B). Side-by-side comparison testing was performed to evaluate the cesium removal performance of each batch to aid in selecting the preferred CST batch and media characteristics to load into the second TCCR unit. Batch contact equilibrium and flow-through column tests have been conducted with three CST batches using an SRS Average Simulant.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Temperature Thermal Barrier Coating Evaluation of Yttrium Aluminum Garnet for Gas Turbine Applications

The Solution Precursor Spray Process (SPPS) process has been shown to overcome the durability and property challenges of applying yttrium aluminum garnet (YAG) coating for high temperature thermal barrier coating (TBC) applications (1200°C+) but only limited testing has been performed in representative application environments. In this study, YAG coatings were developed to optimize microstructure and tailor properties for combustion components in an industrial gas turbine. Thermal conductivity, erosion resistance and furnace cycling durability were used to validate YAG properties against the standard yttria-stabilized zirconia coating (YSZ). Graded and multi-layered microstructures were applied to enhance performance while maintaining durability. Further YAG process development was required to replicate coating properties and optimize deposition on more complex fuel injector nozzle and combustion liner components. Rig testing of both components was performed and compared against the baseline YSZ coating validating the high temperature capability and lower thermal conductivity of the SPPS YAG coating. The components in both tests were cycled for a minimum of ten cycles with the fuel injector test targeting a higher operating temperature while the combustor liner operated at standard conditions. A development engine test is planned to further validate performance in a gas turbine engine of this promising material.

36 MATERIALS SCIENCE↗

LANL’s Digital Supply Chain Transformation with Ariba Part 2 [Slides]

LANL’s budget continues to increase. Our annual procurement spend has increased from approximately 750 million two years ago to 1.4 Billion in FY21. Procurement for LANL is a mix of indirect and direct but had limited managed spend – more standalone orders vs master contracts. The level of transformation we were looking to achieve required a comprehensive approach, encompassing people, processes and software solutions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Microgrid Conceptual Design Guidebook | 2022

This guide is meant to assist communities – from residents to energy experts to decision makers – in developing a conceptual microgrid design that meets site-specific energy resilience goals. Using the framework described in this guidebook, stakeholders can come together and start to quantify site-specific vulnerabilities, identify the most significant risks to delivery of electricity, and establish electric outage tolerances across the community. In addition to establishing minimum service needs, this framework encourages communities to consider broader sustainability goals and policy constraints and begin to estimate up-front costs associated with the installation of alternative microgrid solutions. The framework guides a community through data collection and a high-level assessment of its needs, constraints, and priorities, prior to engaging engineers, vendors, and contractors. The first sections of this guidebook provide a high-level primer on electric systems. The latter sections include guidance for step-by-step data gathering and analysis of site conditions. The ultimate product resulting from the stepwise approach is a conceptual microgrid design. A conceptual design is defined as an initial design (10%-20% complete) that considers the specific threats, needs, limitations, and investment options for a given location. Going through this exercise and developing the conceptual microgrid design as a community ensures the same community members who will ultimately live with the solution are the developers of its foundational design. Often, these are also the very same people who understand system tolerances and needs the best and are therefore the ideal candidates for establishing these criteria. Especially when it comes to evaluating critical infrastructure, it is the community that best understands the most critical services. The framework is intended to facilitate a systematic approach to planning for resilience and provide a deeper understanding of how to use a framework to make decisions around microgrid solutions. Like many processes where tradeoffs need to be considered, this is often an iterative process. If this guide serves to help educate and empower communities who are beginning the process of deploying a microgrid, it has met the goal of its authors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Low-cost sensors and analytics for a digital factory

ORNL Manufacturing Demonstration Facility and Perisense worked on a low-cost solution for machining process monitoring to enable a digital factory. Enabling machine connectivity for digital factors is expensive for many small to medium manufacturers. The hypothesis for the research project is that a lowcost sensor suite, which can be retrofitted to a legacy machine tool or a new machine tool, can effectively provide real-time, in-situ sensing for manufacturing processes, which can enable improvements in process performance and efficiency. The Perisense sensor node was installed on the Haas TM1 machine with a current sensor and an accelerometer. Cutting tests were performed at different process parameters and sensor data was recorded. Results show a correlation of the current sensor to the spindle load. The accelerometer, mounted on the machine base, showed a correlation to the spindle speed as well as the spindle load. The sensor data can be used to monitor the machining process and provide insights on the machine spindle load utilization.

42 ENGINEERING↗

Editorial: Applications of spectroscopy and chemometrics in nuclear materials analysis

Optical analysis techniques, including spectroscopy and image analysis, have many advantages when applied to the study of nuclear materials. They require small sample sizes, can be performed remotely, and can be proceduralized through consistent practice. Most importantly, they provide a wealth of information by generating multivariate data. For example, ultraviolet–visible–near-infrared absorbance spectroscopy of actinides in aqueous and organic solutions is dependent on the oxidation state, anionic complexation, and temperature. These variables are important for solution-based separation processes, and sensitivity to these factors, combined with online monitoring, can drive the efficiency and control of these processes. The morphology and chemical composition of actinide particles can also provide a vital clue to the mechanisms by which the particles were formed, providing forensic information on the origins of the particles.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Stochastic gradient descent algorithm for stochastic optimization in solving analytic continuation problems

We propose a stochastic gradient descent based optimization algorithm to solve the analytic continuation problem in which we extract real frequency spectra from imaginary time Quantum Monte Carlo data. The procedure of analytic continuation is an ill-posed inverse problem which is usually solved by regularized optimization methods, such like the Maximum Entropy method, or stochastic optimization methods. The main contribution of this work is to improve the performance of stochastic optimization approaches by introducing a supervised stochastic gradient descent algorithm to solve a flipped inverse system which processes the random solutions obtained by a type of Fast and Efficient Stochastic Optimization Method.

97 MATHEMATICS AND COMPUTING↗

OPTIMUS{sup TM} Packaging for Intermediate Level Wastes and Spent Fuel - 20129

NAC's OPTIMUS{sup TM} packaging is a family of Type B(U)F transportation packages designed for maximum flexibility and cost-efficiency to support shipment of a wide range of challenging wastes and materials. They are small, modular packaging designs meeting DOT weight limits for road transport. OPTIMUS{sup TM} contents include low level waste, mixed low-level waste, irradiated fuel waste and intermediate level waste. Contents can also include aerosol cans with compressed gas and liquefied gas propellants and standard DOT 3E lecture bottles for shipment to treatment facilities. OPTIMUS{sup TM} packaging provides a cost-effective solution for challenging and unique waste contents combined with design simplicity and operational flexibility meeting the requirements of both SSR-6 and 10 CFR 71 for Type B(U)F packaging. The modular design of the packaging components combined with the flexibility to add modified internals for enhanced packaging performance makes OPTIMUS{sup TM} the preferred solution for many radioactive material transportation needs. The OPTIMUS{sup TM} product line currently includes two packaging designs; OPTIMUS{sup TM}-L and OPTIMUS{sup TM}-H. OPTIMUS{sup TM}-L is a lightweight transportation packaging intended for low-activity wastes, whereas OPTIMUS{sup TM}-H is a larger, heavier package intended for high-activities wastes. Due to its small size and weight, six (6) to ten (10) OPTIMUS{sup TM}-L packages can be accommodated on a single legal-weight truck shipment, depending on the weight of the contents. For typical payloads, two (2) OPTIMUS{sup TM}-H packages can be accommodated on a single legal-weight truck shipment. The OPTIMUS{sup TM} packaging share the same cask containment vessel (CCV) in the OPTIMUS{sup TM}-H and OPTIMUS{sup TM}-L. The large cavity size of the CCV, which can accommodate a 416-liter (110-gallon) drum, combined with the small size, low weight and modularity of the OPTIMUS{sup TM} packaging provides unmatched flexibility. In this paper, NAC provides a technical overview of the OPTIMUS{sup TM} packaging and identifies the design features and technology advancements making the OPTIMUS{sup TM} a readily adaptable and flexible solution for packaging processing facilities, reactor and decommissioning wastes. Optimized shielding performance through the addition of internal shielding components and alternative shipping configurations are discussed. In addition, an overview of the first major deployment of the OPTIMUS{sup TM} packaging for the Whiteshell Laboratories Closure Project (WLCP) is discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Removal and Hydraulic Performance Comparisons of CST Ion Exchange Media Batches in Support of the Tank Closure Cesium Removal Project - 20522

Three batches of Crystalline Silicotitanate (CST) ion exchange media have been evaluated for cesium removal efficiency from a Savannah River Site (SRS) High Level Waste (HLW) supernate simulant in support of the Tank Closure Cesium Removal (TCCR) Project, which involves at-tank column waste treatment. Results will be utilized to select the CST media batch to be added to the next TCCR unit columns. Two of the CST media samples were recent production batches and the third was an archived batch studied extensively at SRS nearly two decades ago. The archived CST batch had a significantly smaller average particle diameter than more recent batches. Small-scale (∼23 mL), side-by-side column tests were conducted at 35 deg. C with each of the CST batches using the same simulant at flow rates near 1.2 mL/min (3.0-3.4 CST bed volumes/hr). The cesium ion exchange column performance results were lower than expected for all three CST batches, but the data indicated that 30% more simulant volume and 40% more equivalent CST bed volumes of solution can be processed with the older CST batch prior to reaching the 50% cesium breakthrough point than can be processed with the newer CST batches. Hydraulic evaluations of the CST columns were also conducted in simulant at 24 deg. C to determine the impact of the different particle size distributions and associated bed porosities on frictional pressure drop under dynamic flow conditions. Higher differential pressure drops were observed with the archived CST batch relative to recent production batches, due to the smaller particle size distribution and the packing characteristics of the archived batch. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Plasma-driven solution electrolysis

Plasmas interacting with liquids enable the generation of a highly reactive interfacial liquid layer due to a variety of processes driven by plasma-produced electrons, ions, photons, and radicals. These processes show promise to enable selective, efficient, and green chemical transformations and new material synthesis approaches. While many differences are to be expected between conventional electrolysis and plasma–liquid interactions, plasma–liquid interactions can be viewed, to a first approximation, as replacing a metal electrode in an electrolytic cell with a gas phase plasma. For this reason, we refer to this method as plasma-driven solution electrochemistry (PDSE). In this Perspective, we address two fundamental questions that should be answered to enable researchers to make transformational advances in PDSE: How far from equilibrium can plasma-induced solution processes be driven? and What are the fundamental differences between PDSE and other more traditional electrochemical processes? Different aspects of both questions are discussed in five sub-questions for which we review the current state-of-the art and we provide a motivation and research vision.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Decontamination of urban surfaces contaminated with radioactive materials and consequent onsite recycling of the waste water

Enhancing rapid remediation strategies is paramount for recovery after a large-scale nuclear contamination event in an urban environment. Some current strategies recommend use of readily available equipment, materials, and facilities to expedite recovery. For example, applying pressurized water to contaminated surfaces may effectively remove radioactive contamination. In this study, a commercial power washer removes soluble forms of 152 Eu 3 + , 85 Sr 2 + , and 137 Cs + contamination from common porous building materials, and computer simulations characterize the recycling of the resultant contaminated wash water. Pressure washing the porous building materials under spray conditions typical with do-it-yourself units improved decontamination factors (DFs) for 152 Eu compared to low-pressure application of tap water (majority of two-tailed t-test p-values < 0.1), but pressure did not improve DFs for 137 Cs or 85 Sr. For both pressurized and low-pressure applications, adding potassium ions (K + ) to promote ion exchange reactions produced significantly higher DFs for tested radionuclides on asphalt, brick, and concrete. The resultant contaminated wash water can be processed through self-prepared chemical filtration beds of clay and sand. Modeled in a prior study, the beds yielded linear trends (R 2 > 0.98) in sensitivity analyses between most bed configuration variables and bed performance variables, permitting flexible ad-hoc bed design. The experimental and simulation results led to estimates of the remediation rate and waste generated after cleaning 250 m 2 of cesium-contaminated concrete from the combined deployment of a power washer and two different mobile treatment beds. Furthermore, the first treatment bed was designed to reduce treatment time and processed 1900 L of wash solution in 70 min using 880 kg of clay/sand infill material. Designed to reduce the solid waste generated, the second bed processed the same solution volume in 1040 min (17 h) using 170 kg of clay/sand infill material. The results of this analysis warrant further investigation of power washing with recycled salt solution as an effective rapid decontamination method with manageable waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗