At least 685 records · Page 38

OSRP Source Repatriations-Case Studies: Brazil, Ecuador, Uruguay

The Global Threat Reduction Initiative's (GTRI) Offsite Source Recovery Project (OSRP) began recovering excess and unwanted radioactive sealed sources (sources) in 1999. As of February 2012, the project had recovered over 30,000 sources totaling over 820,000 Ci. OSRP grew out of early efforts at Los Alamos National Laboratory (LANL) to recover disused excess Plutonium- 239 (Pu-239) sources that were distributed in the 1960's and 1970's under the Atoms for Peace Program. Source recovery was initially considered a waste management activity. However, after the 9/11 terrorist attacks, the interagency community began to recognize that excess and unwanted radioactive sealed sources pose a national security threat, particularly those that lack a disposition path. After OSRP's transfer to the U.S. National Nuclear Security Administration (NNSA) to be part of GTRI, its mission was expanded to include all disused sealed sources that might require national security consideration. Recognizing the transnational threat posed by porous borders and the ubiquitous nature of sources, GTRI/OSRP repatriates U.S. origin sources based on threat reduction prioritization criteria. For example, several recent challenging source repatriation missions have been conducted by GTRI/OSRP in South America. These include the repatriation of a significant amount of Cs-137 and other isotopes from Brazil; re-packaging of conditioned Ra-226 sources in Ecuador for future repatriation; and, multilateral cooperation in the consolidation and export of Canadian, US, and Indian Co-60/Cs-137 sources from Uruguay. In addition, cooperation with regulators and private source owners in other countries presents opportunities for GTRI/OSRP to exchange best practices for managing disused sources. These positive experiences often result in long-term cooperation and information sharing with key foreign counterparts. International source recovery operations are essential to the preservation of U.S. national security interests. They are also mutually beneficial for fostering positive relationships with other governments and private industry, and demonstrate that responsible end-of-life options are given to legacy U.S.-origin sources in other countries. GTRI/OSRP does not take back sources that have a viable path for commercial disposal. Most US origin sources were sold commercially and were not provided by the US government. Below is a synopsis of cooperative efforts with Brazil, Ecuador, and Uruguay. Bilateral and multilateral efforts have been successful in removing hundreds of U.S.origin sealed radioactive sources from Latin American countries to the U.S. As many disused sources remain in the region, and since repatriation is not always an option, GTRI will continue to work with those countries to ensure that these sources are stored securely for the long-term. Successful Latin America operations should serve as a model for other regional cooperation in the repatriation of sealed sources, encouraging other source exporting countries to implement similar programs. Securing and removing sources, both domestically and internationally, is crucial to strengthening the life-cycle management of radioactive sources worldwide. Such efforts not only prevent these materials from being used maliciously, but also address public health and safety concerns, and under-gird the IAEA Code of Conduct on the Safety and Security of Radioactive Sources. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

EGSnrc-based Monte Carlo dosimetry of CSA1 and CSA2 {sup 137}Cs brachytherapy source models

Purpose: AAPM TG-56 recommends the use of a specific dosimetric dataset for each brachytherapy source model. In this study, a full dosimetric dataset for indigenously developed {sup 137}Cs source models, namely, the CSA1 and CSA2, in accordance with the AAPM TG-43U1 formalism is presented. The study includes calculation of dose-to-kerma ratio D/K in water around these sources including stainless steel encapsulated {sup 137}Cs sources such as RTR, 3M, and selectron/LDR {sup 137}Cs. Methods: The Monte Carlo-based EGSnrcMP code system is employed for modeling the sources in vacuum and in water. Calculations of air-kerma strength, S{sub K} for the investigated sources and collision kerma in water along the transverse axis of the RTR source are based on the FLURZnrc code. Simulations of water-kerma and dose in water for the CSA1, CSA2, RTR, 3M, and selectron/LDR {sup 137}Cs sources are carried out using the DOSRZnrc code. In DOSRZnrc calculations, water-kerma and dose are scored in a cylindrical water phantom having dimensions of 80 cm diameterx80 cm height. Results: The calculated dose-rate constants for the CSA1 and CSA2 sources are 0.945(1) and 1.023(1) cGy/(h U), respectively. The calculated value of S{sub K} per unit source activity, S{sub K}/A for the CSA1 and CSA2 sources is 7.393(7)x10{sup -8} cGy cm{sup 2}/(h Bq). The EGSnrcMP-based collision kerma rates for the RTR source along the transverse axis (0.25-10 cm) agree with the corresponding GEANT4-based published values within 0.5%. Anisotropy profiles of the CSA1 and CSA2 sources are significantly different from those of other sources. For the selectron/LDR single pellet {sup 137}Cs spherical source (modeled as a cylindrical pellet with dimensions similar to the seed selectron), the values of D/K at 1 and 1.25 mm from the capsule are 1.023(1) and 1.029(1), respectively. The value of D/K at 1 mm from the CSA1, CSA2, RTR, and 3M {sup 137}Cs source capsules (all sources have an external radius of 1.5 mm) is 1.017(1) and this ratio is applicable to axial positions z=0 to z={+-}L/2. This is in contrast to a published GEANT4-based Monte Carlo dosimetric study on RTR and 3M {sup 137}Cs sources wherein the authors have assumed that collision kerma is approximately equal to absorbed dose at 1 mm from the source capsules. Collision kerma is approximately equal to absorbed dose for distances {>=}2 mm from source capsules as opposed to {>=}1 mm reported in published studies. A detailed electron transport is necessary up to 2 mm from source capsules. Conclusions: The Monte Carlo-calculated dose-rate data for the CSA1 and CSA2 sources can be used as input data for treatment planning or to verify the calculations by radiotherapy treatment planning system.

61 RADIATION PROTECTION AND DOSIMETRY↗

IDENTIFICATIONS AND PHOTOMETRIC REDSHIFTS OF THE 2 Ms CHANDRA DEEP FIELD-SOUTH SOURCES

We present reliable multiwavelength identifications and high-quality photometric redshifts for the 462 X-ray sources in the {approx}2 Ms Chandra Deep Field-South (CDF-S) survey. Source identifications are carried out using deep optical-to-radio multiwavelength catalogs, and are then combined to create lists of primary and secondary counterparts for the X-ray sources. We identified reliable counterparts for 442 (95.7%) of the X-ray sources, with an expected false-match probability of {approx} 6.2%; we also selected four additional likely counterparts. The majority of the other 16 X-ray sources appear to be off-nuclear sources, sources associated with galaxy groups and clusters, high-redshift active galactic nuclei (AGNs), or spurious X-ray sources. A likelihood-ratio method is used for source matching, which effectively reduces the false-match probability at faint magnitudes compared to a simple error-circle matching method. We construct a master photometric catalog for the identified X-ray sources including up to 42 bands of UV-to-infrared data, and then calculate their photometric redshifts (photo-z's). High accuracy in the derived photo-z's is accomplished owing to (1) the up-to-date photometric data covering the full spectral energy distributions (SEDs) of the X-ray sources, (2) more accurate photometric data as a result of source deblending for {approx}10% of the sources in the infrared bands and a few percent in the optical and near-infrared bands, (3) a set of 265 galaxy, AGN, and galaxy/AGN hybrid templates carefully constructed to best represent all possible SEDs, (4) the Zurich Extragalactic Bayesian Redshift Analyzer used to derive the photo-z's, which corrects the SED templates to best represent the SEDs of real sources at different redshifts and thus improves the photo-z quality. The reliability of the photo-z's is evaluated using the subsample of 220 sources with secure spectroscopic redshifts. We achieve an accuracy of |{delta}z|/(1 + z) {approx} 1% and an outlier [with |{delta}z|/(1 + z)>0.15] fraction of {approx}1.4% for sources with spectroscopic redshifts. We performed blind tests to derive a more realistic estimate of the photo-z quality for sources without spectroscopic redshifts. We expect there are {approx}9% outliers for the relatively brighter sources (R {approx}< 26), and the outlier fraction will increase to {approx}15%-25% for the fainter sources (R {approx}> 26). The typical photo-z accuracy is {approx}6%-7%. The outlier fraction and photo-z accuracy do not appear to have a redshift dependence (for z {approx} 0-4). These photo-z's appear to be the best obtained so far for faint X-ray sources, and they have been significantly ({approx}>50%) improved compared to previous estimates of the photo-z's for the X-ray sources in the {approx}2 Ms Chandra Deep Field-North and {approx}1 Ms CDF-S.

79 ASTRONOMY AND ASTROPHYSICS↗

End of Life Decisions for Sealed Radioactive Sources

Sealed radioactive sources are encountered in a wide variety of settings – from household smoke detectors and instrument check sources, through fixed industrial gauges, industrial radiography and well logging sources, to irradiators and medical teletherapy devices. In general, the higher the level of activity in the sealed source, the stricter the regulatory control that is applied to its use, control and ultimate disposition. Lower levels of attention and oversight can and do lead to sources ending up in the wrong place – as orphan sources in uncontrolled storage, disposed in a sanitary landfill, melted down in metal recycling operations and incorporated into consumer products, or handled by an unsuspecting member of the public. There are a range of issues that contribute to the problem of improper disposal of sealed sources, and, in particular, to disused source disposal. General licensed sources and devices are particularly at risk of being disposed incorrectly. Higher activity general licensed sources, although required to be registered with the Nuclear Regulatory Commission (NRC) or Agreement State, receive limited regulatory oversight and are not tracked on a national scale. Users frequently do not consider the full life-cycle costs when procuring sources or devices and discover that they cannot afford to package, transport and dispose of their sources properly. The NRC requirements for decommissioning funding plans and financial assurance are not adequate to cover sealed source transport and disposal costs fully. While there are regulatory limits for storage of disused sources, enforcement is limited and there is no financial incentive for owners to dispose of the sources. In some cases, the lack of availability of approved Department of Transportation (DOT) Type B shipping casks also presents a barrier to sealed source disposal. The report of the Disused Sources Working Group does an excellent job of framing these issues. This article reviews both the issues and the report’s recommendations, which are designed to improve sealed source control and encourage proper disposal of disused sources.

disused source↗

Radiological Risk From Disused Radioactive Sealed Sources in Egypt - 19083

Sealed sources are radioactive nuclear substances encased in a sealed capsule or in a cover to which the substance is bonded, and are used for a variety of activities, such as medical, industrial, academic and research, as well as commercial applications. While most sources are of relatively low activity, there are many of medium or very high activity. In use radioactive sealed sources after time become disused sources according to several reasons like, if the source activity became less than the desired activity (unfit for the intended application), if the model of the instrument became old fashion and no longer uses, if the source had been damaged, and if the user company was shut down and no longer in business. In developing countries, thousands of radium needles, teletherapy sources, oil well logging neutron sources, and miscellaneous industrial radioactive gauges are annually collected as waste and stored in centralized waste facilities. Although these sources become disused, it still dangerous and the mismanagement of high activity sources is responsible for most of the radiological accidents that result in loss of life or disabling injuries. On the other hand, these sources may be a target for criminal acts in countries where final disposal options are unavailable. Egyptian Atomic Energy Authority (EAEA) represented in Hot Labs and Waste Management Center (HLWMC) is responsible by the national nuclear law (law No. 7 /2010) for management of all kinds of radioactive waste including disused radioactive sealed sources from all Egyptian territories. Categorization of disused sources is necessary to ensure that the controls and security measures that are applied to the sources are adequate with its radiological risk. The aim of this work is to use the international Atomic Energy Agency (IAEA) categorization system to provide a simple, logical system for grading disused radioactive sealed sources in Egypt as well as to update the inventory of such sources which already collected as waste in Egypt. The categorizations of radioactive sealed sources are based on their potential to cause harm to human health. This study revealed that nearly 980 sources have been defined in Egypt as disused sources with a total activity of 46100 Ci according to available data in July 2018. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

THE CHANDRA DEEP FIELD-SOUTH SURVEY: 4 Ms SOURCE CATALOGS

We present source catalogs for the 4 Ms Chandra Deep Field-South (CDF-S), which is the deepest Chandra survey to date and covers an area of 464.5 arcmin{sup 2}. We provide a main Chandra source catalog, which contains 740 X-ray sources that are detected with WAVDETECT at a false-positive probability threshold of 10{sup -5} in at least one of three X-ray bands (0.5-8 keV, full band; 0.5-2 keV, soft band; and 2-8 keV, hard band) and also satisfy a binomial-probability source-selection criterion of P < 0.004 (i.e., the probability of sources not being real is less than 0.004); this approach is designed to maximize the number of reliable sources detected. A total of 300 main-catalog sources are new compared to the previous 2 Ms CDF-S main-catalog sources. We determine X-ray source positions using centroid and matched-filter techniques and obtain a median positional uncertainty of {approx}0.''42. We also provide a supplementary catalog, which consists of 36 sources that are detected with WAVDETECT at a false-positive probability threshold of 10{sup -5}, satisfy the condition of 0.004 < P < 0.1, and have an optical counterpart with R < 24. Multiwavelength identifications, basic optical/infrared/radio photometry, and spectroscopic/photometric redshifts are provided for the X-ray sources in the main and supplementary catalogs. Seven hundred sixteen ({approx}97%) of the 740 main-catalog sources have multiwavelength counterparts, with 673 ({approx}94% of 716) having either spectroscopic or photometric redshifts. The 740 main-catalog sources span broad ranges of full-band flux and 0.5-8 keV luminosity; the 300 new main-catalog sources span similar ranges although they tend to be systematically lower. Basic analyses of the X-ray and multiwavelength properties of the sources indicate that >75% of the main-catalog sources are active galactic nuclei (AGNs); of the 300 new main-catalog sources, about 35% are likely normal and starburst galaxies, reflecting the rise of normal and starburst galaxies at the very faint flux levels uniquely accessible to the 4 Ms CDF-S. Near the center of the 4 Ms CDF-S (i.e., within an off-axis angle of 3'), the observed AGN and galaxy source densities have reached 9800{sup +1300}{sub -1100} deg{sup -2} and 6900{sup +1100}{sub -900} deg{sup -2}, respectively. Simulations show that our main catalog is highly reliable and is reasonably complete. The mean backgrounds (corrected for vignetting and exposure-time variations) are 0.063 and 0.178 counts Ms{sup -1} pixel{sup -1} (for a pixel size of 0.''492) for the soft and hard bands, respectively; the majority of the pixels have zero background counts. The 4 Ms CDF-S reaches on-axis flux limits of {approx}3.2 x 10{sup -17}, 9.1 x 10{sup -18}, and 5.5 x 10{sup -17} erg cm{sup -2} s{sup -1} for the full, soft, and hard bands, respectively. An increase in the CDF-S exposure time by a factor of {approx}2-2.5 would provide further significant gains and probe key unexplored discovery space.

79 ASTRONOMY AND ASTROPHYSICS↗

THE CHANDRA SOURCE CATALOG

The Chandra Source Catalog (CSC) is a general purpose virtual X-ray astrophysics facility that provides access to a carefully selected set of generally useful quantities for individual X-ray sources, and is designed to satisfy the needs of a broad-based group of scientists, including those who may be less familiar with astronomical data analysis in the X-ray regime. The first release of the CSC includes information about 94,676 distinct X-ray sources detected in a subset of public Advanced CCD Imaging Spectrometer imaging observations from roughly the first eight years of the Chandra mission. This release of the catalog includes point and compact sources with observed spatial extents {approx}<30''. The catalog (1) provides access to the best estimates of the X-ray source properties for detected sources, with good scientific fidelity, and directly supports scientific analysis using the individual source data; (2) facilitates analysis of a wide range of statistical properties for classes of X-ray sources; and (3) provides efficient access to calibrated observational data and ancillary data products for individual X-ray sources, so that users can perform detailed further analysis using existing tools. The catalog includes real X-ray sources detected with flux estimates that are at least 3 times their estimated 1{sigma} uncertainties in at least one energy band, while maintaining the number of spurious sources at a level of {approx}<1 false source per field for a 100 ks observation. For each detected source, the CSC provides commonly tabulated quantities, including source position, extent, multi-band fluxes, hardness ratios, and variability statistics, derived from the observations in which the source is detected. In addition to these traditional catalog elements, for each X-ray source the CSC includes an extensive set of file-based data products that can be manipulated interactively, including source images, event lists, light curves, and spectra from each observation in which a source is detected.

79 ASTRONOMY AND ASTROPHYSICS↗

Influence of source batch S{sub K} dispersion on dosimetry for prostate cancer treatment with permanent implants

Purpose: In clinical practice, specific air kerma strength (S{sub K}) value is used in treatment planning system (TPS) permanent brachytherapy implant calculations with {sup 125}I and {sup 103}Pd sources; in fact, commercial TPS provide only one S{sub K} input value for all implanted sources and the certified shipment average is typically used. However, the value for S{sub K} is dispersed: this dispersion is not only due to the manufacturing process and variation between different source batches but also due to the classification of sources into different classes according to their S{sub K} values. The purpose of this work is to examine the impact of S{sub K} dispersion on typical implant parameters that are used to evaluate the dose volume histogram (DVH) for both planning target volume (PTV) and organs at risk (OARs). Methods: The authors have developed a new algorithm to compute dose distributions with different S{sub K} values for each source. Three different prostate volumes (20, 30, and 40 cm{sup 3}) were considered and two typical commercial sources of different radionuclides were used. Using a conventional TPS, clinically accepted calculations were made for {sup 125}I sources; for the palladium, typical implants were simulated. To assess the many different possible S{sub K} values for each source belonging to a class, the authors assigned an S{sub K} value to each source in a randomized process 1000 times for each source and volume. All the dose distributions generated for each set of simulations were assessed through the DVH distributions comparing with dose distributions obtained using a uniform S{sub K} value for all the implanted sources. The authors analyzed several dose coverage (V{sub 100} and D{sub 90}) and overdosage parameters for prostate and PTV and also the limiting and overdosage parameters for OARs, urethra and rectum. Results: The parameters analyzed followed a Gaussian distribution for the entire set of computed dosimetries. PTV and prostate V{sub 100} and D{sub 90} variations ranged between 0.2% and 1.78% for both sources. Variations for the overdosage parameters V{sub 150} and V{sub 200} compared to dose coverage parameters were observed and, in general, variations were larger for parameters related to {sup 125}I sources than {sup 103}Pd sources. For OAR dosimetry, variations with respect to the reference D{sub 0.1cm{sup 3}} were observed for rectum values, ranging from 2% to 3%, compared with urethra values, which ranged from 1% to 2%. Conclusions: Dose coverage for prostate and PTV was practically unaffected by S{sub K} dispersion, as was the maximum dose deposited in the urethra due to the implant technique geometry. However, the authors observed larger variations for the PTV V{sub 150}, rectum V{sub 100}, and rectum D{sub 0.1cm{sup 3}} values. The variations in rectum parameters were caused by the specific location of sources with S{sub K} value that differed from the average in the vicinity. Finally, on comparing the two sources, variations were larger for {sup 125}I than for {sup 103}Pd. This is because for {sup 103}Pd, a greater number of sources were used to obtain a valid dose distribution than for {sup 125}I, resulting in a lower variation for each S{sub K} value for each source (because the variations become averaged out statistically speaking)

60 APPLIED LIFE SCIENCES↗

Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons

Purpose: The region of electronic disequilibrium near photon-emitting brachytherapy sources of high-energy radionuclides ({sup 60}Co, {sup 137}Cs, {sup 192}Ir, and {sup 169}Yb) and contributions to total dose from emitted electrons were studied using the GEANT4 and PENELOPE Monte Carlo codes. Methods: Hypothetical sources with active and capsule materials mimicking those of actual sources but with spherical shape were examined. Dose contributions due to source photons, x rays, and bremsstrahlung; source {beta}{sup -}, Auger electrons, and internal conversion electrons; and water collisional kerma were scored. To determine if conclusions obtained for electronic equilibrium conditions and electron dose contribution to total dose for the representative spherical sources could be applied to actual sources, the {sup 192}Ir mHDR-v2 source model (Nucletron B.V., Veenendaal, The Netherlands) was simulated for comparison to spherical source results and to published data. Results: Electronic equilibrium within 1% is reached for {sup 60}Co, {sup 137}Cs, {sup 192}Ir, and {sup 169}Yb at distances greater than 7, 3.5, 2, and 1 mm from the source center, respectively, in agreement with other published studies. At 1 mm from the source center, the electron contributions to total dose are 1.9% and 9.4% for {sup 60}Co and {sup 192}Ir, respectively. Electron emissions become important (i.e., >0.5%) within 3.3 mm of {sup 60}Co and 1.7 mm of {sup 192}Ir sources, yet are negligible over all distances for {sup 137}Cs and {sup 169}Yb. Electronic equilibrium conditions along the transversal source axis for the mHDR-v2 source are comparable to those of the spherical sources while electron dose to total dose contribution are quite different. Conclusions: Electronic equilibrium conditions obtained for spherical sources could be generalized to actual sources while electron contribution to total dose depends strongly on source dimensions, material composition, and electron spectra.

61 RADIATION PROTECTION AND DOSIMETRY↗

Guide for Employing High-Resolution Gamma Spectroscopy for 252Cf Source Age and Isotopic Composition

Californium-252 is commonly used as a calibration source for neutron coincidence and neutron multiplicity counting in nuclear safeguards. Accurate knowledge of the neutron emission rate, age, and isotopics of the source (i.e., “source term”) are important for ensuring the best possible accuracies in item assay results. Californium-252 sources are not usually measured using gamma spectrometry, because of the assumption that their gamma-ray spectra appear to provide little information. However, gamma-ray signatures produced from 252Cf spontaneous fission products and odd-numbered Cf isotopes can be useful in determining source age and Cf isotopic composition. We demonstrate the utility of high-resolution gamma spectrometry in determining the age and isotopics of Cf neutron sources. In this work, five 252Cf sources were measured using a high-purity germanium detector. The neutron flux was small enough that radiation damage from prolonged neutron exposure was not substantial. Spectra were collected in 2-hour increments for 42–48 hours for quality control. The 2-hour spectra were added together to create a single spectrum for each source, and peak analyses were performed. Source ages were determined using a method that involved experimentally measuring the ratio of the gamma-ray emission rate of the 661.657 keV from 137Cs relative to a short-lived fission product and exploiting the dependence of this ratio on the source age. Source age was solved for using emission rates from four different gamma lines from four short-lived spontaneous fission products. Analysis results from all four fission products returned statistically similar source ages, but two had uncertainties greater than 25% because of high spontaneous fission product yield uncertainties as nominally high as 63%. Choosing short-lived fission products with small yield uncertainties is most important for accurately calculating source age. Additionally, the calculated ages did not always match the time since 248Cm separation well, which is often assumed to be the source age on the technical data sheet provided by the manufacturer. Activity ratios of 249Cf to 251Cf, the only Cf gamma emitters present in a 252Cf source, also did not match between experimental data and data on the technical data sheet provided by the vendor. It is thus recommended that newly purchased Cf sources be examined using gamma spectrometry to determine the source age and confirm isotopic composition of a 252Cf calibration source.

Watson, Mara M.↗

Management of Disused Sealed Sources in Austria - 12147

The use of sealed radiation sources is regulated by the Austrian Radiation Protection Act and the General Radiation Protection Ordinance. The Austrian radiation protection legislation requires minimisation of radioactive waste. The preferred radioactive waste management option concerning sealed sources, both spent and disused, is the return to the manufacturer. If this is not possible a reuse by a third party is encouraged. According to this requirement, disused sealed sources shall, as far as possible, be stored on the site of the licence holder until a new owner is found. If this is not possible, disused sealed sources shall be transported to Nuclear Engineering Seibersdorf, which is a recognised storage facility for radioactive waste in Austria, for temporary storage pending reuse. Sources, which cannot be reused, are declared as radioactive waste. Since Austria is a Member State of the European Union, the Council Directive 122/2003/Euratom on High Activity Sealed Sources and Orphan Sources is applied. This directive defines high activity sealed sources on the basis of their total activity. The possession of such sources is subject to certain obligations. Therefore it is in the interest of the owner to return disused sources as soon as possible to the manufacturer or to deliver them to Nuclear Engineering Seibersdorf. In case of the loss and finding of an 'orphan' source the competent authority secures, recovers and stores the source at the cost of the owner of the source with recourse. In line with the directive the licensee of a High Activity Sealed Source has to notify the main data concerning this source to the Central Source Register which is maintained by the Federal Minister of Agriculture, Forestry, Environment and Water Management for all radioactive sources. This register was put into operation in 2006. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Design of an Yb-169 source optimized for gold nanoparticle-aided radiation therapy

Purpose: To find an optimum design of a new high-dose rate ytterbium (Yb)-169 brachytherapy source that would maximize the dose enhancement during gold nanoparticle-aided radiation therapy (GNRT), while meeting practical constraints for manufacturing a clinically relevant brachytherapy source. Methods: Four different Yb-169 source designs were considered in this investigation. The first three source models had a single encapsulation made of one of the following materials: aluminum, titanium, and stainless steel. The last source model adopted a dual encapsulation design with an inner aluminum capsule surrounding the Yb-core and an outer titanium capsule. Monte Carlo (MC) simulations using the Monte Carlo N-Particle code version 5 (MCNP5) were conducted initially to investigate the spectral changes caused by these four source designs and the associated variations in macroscopic dose enhancement across the tumor loaded with gold nanoparticles (GNPs) at 0.7% by weight. Subsequent MC simulations were performed using the EGSnrc and NOREC codes to determine the secondary electron spectra and microscopic dose enhancement as a result of irradiating the GNP-loaded tumor with the MCNP-calculated source spectra. Results: Effects of the source filter design were apparent in the current MC results. The intensity-weighted average energy of the Yb-169 source varied from 108.9 to 122.9 keV, as the source encapsulation material changed from aluminum to stainless steel. Accordingly, the macroscopic dose enhancement calculated at 1 cm away from the source changed from 51.0% to 45.3%. The sources encapsulated by titanium and aluminum/titanium combination showed similar levels of dose enhancement, 49.3% at 1 cm, and average energies of 113.0 and 112.3 keV, respectively. While the secondary electron spectra due to the investigated source designs appeared to look similar in general, some differences were noted especially in the low energy region (<50 keV) of the spectra suggesting the dependence of the photoelectron yield on the atomic number of source filter material, consistent with the macroscopic dose enhancement results. A similar trend was also shown in the so-called microscopic dose enhancement factor, for example, resulting in the maximum values of 138 and 119 for the titanium- and the stainless steel-encapsulated Yb-169 sources, respectively. Conclusions: The current results consistently show that the dose enhancement achievable from the Yb-169 source is closely related with the atomic number (Z) of source encapsulation material. While the observed range of improvement in the dose enhancement may be considered moderate after factoring all uncertainties in the MC results, the current study provides a reasonable support for the encapsulation of the Yb-core with lower-Z materials than stainless steel, for GNRT applications. Overall, the titanium capsule design can be favored over the aluminum or dual aluminum/titanium capsule designs, due to its superior structural integrity and improved safety during manufacturing and clinical use.

07 ISOTOPE AND RADIATION SOURCES↗

SU-D-19A-05: The Dosimetric Impact of Using Xoft Axxent® Electronic Brachytherapy Source TG-43 Dosimetry Parameters for Treatment with the Xoft 30 Mm Diameter Vaginal Applicator

Purpose: A full TG-43 dosimetric characterization has not been performed for the Xoft Axxent ® electronic brachytherapy source (Xoft, a subsidiary of iCAD, San Jose, CA) within the Xoft 30 mm diameter vaginal applicator. Currently, dose calculations are performed using the bare-source TG-43 parameters and do not account for the presence of the applicator. This work focuses on determining the difference between the bare-source and sourcein- applicator TG-43 parameters. Both the radial dose function (RDF) and polar anisotropy function (PAF) were computationally determined for the source-in-applicator and bare-source models to determine the impact of using the bare-source dosimetry data. Methods: MCNP5 was used to model the source and the Xoft 30 mm diameter vaginal applicator. All simulations were performed using 0.84p and 0.03e cross section libraries. All models were developed based on specifications provided by Xoft. The applicator is made of a proprietary polymer material and simulations were performed using the most conservative chemical composition. An F6 collision-kerma tally was used to determine the RDF and PAF values in water at various dwell positions. The RDF values were normalized to 2.0 cm from the source to accommodate the applicator radius. Source-in-applicator results were compared with bare-source results from this work as well as published baresource results. Results: For a 0 mm source pullback distance, the updated bare-source model and source-in-applicator RDF values differ by 2% at 3 cm and 4% at 5 cm. The largest PAF disagreements were observed at the distal end of the source and applicator with up to 17% disagreement at 2 cm and 8% at 8 cm. The bare-source model had RDF values within 2.6% of the published TG-43 data and PAF results within 7.2% at 2 cm. Conclusion: Results indicate that notable differences exist between the bare-source and source-in-applicator TG-43 simulated parameters. Xoft Inc. provided partial funding for this work.

60 APPLIED LIFE SCIENCES↗

A revised dosimetric characterization of the model S700 electronic brachytherapy source containing an anode-centering plastic insert and other components not included in the 2006 model

Purpose: The model S700 Axxent electronic brachytherapy source by Xoft, Inc., was characterized by Rivard et al. in 2006. Since then, the source design was modified to include a new insert at the source tip. Current study objectives were to establish an accurate source model for simulation purposes, dosimetrically characterize the new source and obtain its TG-43 brachytherapy dosimetry parameters, and determine dose differences between the original simulation model and the current model S700 source design. Methods: Design information from measurements of dissected model S700 sources and from vendor-supplied CAD drawings was used to aid establishment of an updated Monte Carlo source model, which included the complex-shaped plastic source-centering insert intended to promote water flow for cooling the source anode. These data were used to create a model for subsequent radiation transport simulations in a water phantom. Compared to the 2006 simulation geometry, the influence of volume averaging close to the source was substantially reduced. A track-length estimator was used to evaluate collision kerma as a function of radial distance and polar angle for determination of TG-43 dosimetry parameters. Results for the 50 kV source were determined every 0.1 cm from 0.3 to 15 cm and every 1° from 0° to 180°. Photon spectra in water with 0.1 keV resolution were also obtained from 0.5 to 15 cm and polar angles from 0° to 165°. Simulations were run for 10{sup 10} histories, resulting in statistical uncertainties on the transverse plane of 0.04% at r = 1 cm and 0.06% at r = 5 cm. Results: The dose-rate distribution ratio for the model S700 source as compared to the 2006 model exceeded unity by more than 5% for roughly one quarter of the solid angle surrounding the source, i.e., θ ≥ 120°. The radial dose function diminished in a similar manner as for an {sup 125}I seed, with values of 1.434, 0.636, 0.283, and 0.0975 at 0.5, 2, 5, and 10 cm, respectively. The radial dose function ratio between the current and the 2006 model had a minimum of 0.980 at 0.4 cm, close to the source sheath and for large distances approached 1.014. 2D anisotropy function ratios were close to unity for 50° ≤ θ ≤ 110°, but exceeded 5% for θ < 40° at close distances to the sheath and exceeded 15% for θ > 140°, even at large distances. Photon energy fluence of the updated model as compared to the 2006 model showed a decrease in output with increasing distance; this effect was pronounced at the lowest energies. A decrease in photon fluence with increase in polar angle was also observed and was attributed to the silver epoxy component. Conclusions: Changes in source design influenced the overall dose rate and distribution by more than 2% in several regions. This discrepancy is greater than the dose calculation acceptance criteria as recommended in the AAPM TG-56 report. The effect of the design change on the TG-43 parameters would likely not result in dose differences outside of patient applicators. Adoption of this new dataset is suggested for accurate depiction of model S700 source dose distributions.

60 APPLIED LIFE SCIENCES↗

Report of the Basic Energy Sciences Workshop on Compact Light Sources

This report is based on a BES Workshop on Compact Light Sources, held May 11-12, 2010, to evaluated the advantages and disadvantages of compact light source approaches and compared their performance to the third generation storage rings and free-electron lasers. The workshop examined the state of the technology for compact light sources and their expected progress. The workshop evaluated the cost efficiency, user access, availability, and reliability of such sources. Working groups evaluated the advantages and disadvantages of Compact Light Source (CLS) approaches, and compared their performance to the third-generation storage rings and free-electron lasers (FELs). The primary aspects of comparison were 1) cost effectiveness, 2) technical availability v. time frame, and 3) machine reliability and availability for user access. Five categories of potential sources were analyzed: 1) inverse Compton scattering (ICS) sources, 2) mini storage rings, 3) plasma sources, 4) sources using plasma-based accelerators, and 5) laser high harmonic generation (HHG) sources. Compact light sources are not a substitute for large synchrotron and FEL light sources that typically also incorporate extensive user support facilities. Rather they offer attractive, complementary capabilities at a small fraction of the cost and size of large national user facilities. In the far term they may offer the potential for a new paradigm of future national user facility. In the course of the workshop, we identified overarching R&D topics over the next five years that would enhance the performance potential of both compact and large-scale sources: Development of infrared (IR) laser systems delivering kW-class average power with femtosecond pulses at kHz repetition rates. These have application to ICS sources, plasma sources, and HHG sources. Development of laser storage cavities for storage of 10-mJ picosecond and femtosecond pulses focused to micron beam sizes. Development of high-brightness, high-repetition-rate electron sources. Development of continuous wave (cw) superconducting rf linacs operating at 4 K, while not essential, would reduce capital and operating cost.

47 OTHER INSTRUMENTATION↗

Nuisance Source Population Modeling for Radiation Detection System Analysis

A major challenge facing the prospective deployment of radiation detection systems for homeland security applications is the discrimination of radiological or nuclear 'threat sources' from radioactive, but benign, 'nuisance sources'. Common examples of such nuisance sources include naturally occurring radioactive material (NORM), medical patients who have received radioactive drugs for either diagnostics or treatment, and industrial sources. A sensitive detector that cannot distinguish between 'threat' and 'benign' classes will generate false positives which, if sufficiently frequent, will preclude it from being operationally deployed. In this report, we describe a first-principles physics-based modeling approach that is used to approximate the physical properties and corresponding gamma ray spectral signatures of real nuisance sources. Specific models are proposed for the three nuisance source classes - NORM, medical and industrial. The models can be validated against measured data - that is, energy spectra generated with the model can be compared to actual nuisance source data. We show by example how this is done for NORM and medical sources, using data sets obtained from spectroscopic detector deployments for cargo container screening and urban area traffic screening, respectively. In addition to capturing the range of radioactive signatures of individual nuisance sources, a nuisance source population model must generate sources with a frequency of occurrence consistent with that found in actual movement of goods and people. Measured radiation detection data can indicate these frequencies, but, at present, such data are available only for a very limited set of locations and time periods. In this report, we make more general estimates of frequencies for NORM and medical sources using a range of data sources such as shipping manifests and medical treatment statistics. We also identify potential data sources for industrial source frequencies, but leave the task of estimating these frequencies for future work. Modeling of nuisance source populations is only useful if it helps in understanding detector system performance in real operational environments. Examples of previous studies in which nuisance source models played a key role are briefly discussed. These include screening of in-bound urban traffic and monitoring of shipping containers in transit to U.S. ports.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Threat Identification Parameters for a Stolen Category 1 Radioactive Source

Radioactive sources are used very widely for research and practical applications across medicine, industry, government, universities, and agriculture. The risks associated with these sources vary widely depending on the specific radionuclide used to make the source, source activity, and its chemical and physical form. Sources are categorized by a variety of classification schemes according to the specific risk they pose to the public. This report specifically addresses sources that are classified in the highest category for health risk (category 1). Exposure to an unshielded or lightly shielded category 1 source is extremely dangerous to life and health and can be fatal in relatively short exposure times measured in seconds to minutes. A Category 1 source packaged according to the guidelines dictated by the NRC and U.S. Department of Transportation will typically be surrounded by a large amount of dense shielding material, but will still exhibit a significant dose rate in close proximity. Detection ranges for Category 1 gamma ray sources can extend beyond 5000 ft, but will depend mostly on the source isotope and activity, and the level of shielding around the source. Category 1 sources are easy to detect, but difficult to localize. Dose rates in proximity to an unshielded Category 1 source are extraordinarily high. At distances of a few hundred feet, the functionality of many commonly used handheld instruments will be extremely limited for both the localization and identification of the source. Radiation emitted from a Category 1 source will scatter off of both solid material (ground and buildings) and the atmosphere, a phenomenon known as skyshine. This scattering affects the ability to easily localize and find the source.

07 ISOTOPE AND RADIATION SOURCES↗

Management of Disused Sealed Sources in Hungary - 13077

Since 1976 the spent and disused radioactive sources arisen in Hungary are stored in a central storage facility called Radioactive Waste Treatment and Disposal Facility operated by Public Limited Company for Radioactive Waste Management. The Facility is responsible for the record keeping, the waste acceptance procedure, the shipment and the storage or disposal (whether a certain source meets the waste acceptance criteria for disposal or not) of sources. Based on the more than 35 year old operation of the facility many experiences have been gathered regarding the technology for long-term storage of sources, the attitude of the users of sources, the evolution of the legislation and the national record keeping system. Recently a new legislation for the security of radioactive materials (including sources) was introduced, first in Central-Europe. It requires special security arrangements from the facility for transport and for storage. Due to the ongoing retrieval of radioactive waste formerly disposed of, partly containing sealed sources, there is a new challenge in the physical inventory control of historical waste. The paper would show the effect of the changes in the legislation system of record keeping or security on the users' attitude for discard of sources and on the management of the sources in the facility. The facility has a unique storage technology (shallow boreholes) in the narrow region. The sealed sources are placed into vertical pipes sunk into the surface. In the beginning, each of the sources were dropped into the pipe directly, recently they are placed in a metal tube first ensuring the retrieval. The lessons learned will be presented. There were several issues to introduce the new security arrangements (partly financially supported by US DOE) for storage and for transportation of sealed sources. These issues are addressed. In the past part of the sealed sources were disposed together with solid radioactive waste packaged in plastic bags. A waste retrieval campaign was fulfilled in 2008 to retrieve the sealed sources. The paper demonstrates the conditions of sealed sources after twenty-year disposal period. As a summary, the paper will share the main experiences of a 35-year old facility, managing radioactive sealed sources in Central Europe. (authors)