Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Evaluation of a novel collimator for molecular breast tomosynthesis

Here, this study investigated a novel gamma camera for molecular breast tomosynthesis (MBT), which is a nuclear breast imaging method that uses limited angle tomography. The camera is equipped with a variable angle, slant-hole (VASH) collimator that allows the camera to remain close to the breast throughout the acquisition. The goal of this study was to evaluate the spatial resolution and count sensitivity of this camera and to compare contrast and contrast-to-noise ratio (CNR) with conventional planar imaging using an experimental breast phantom. Methods The VASH collimator mounts to a commercial gamma camera for breast imaging that uses a pixelated (3.2 mm), 15 × 20 cm NaI crystal. Spatial resolution was measured in planar images over a range of distances from the collimator (30-100 mm) and a range of slant angles (–25° to 25°) using 99m Tc line sources. Spatial resolution was also measured in reconstructed MBT images including in the depth dimension. The images were reconstructed from data acquired over the -25° to 25° angular range using an iterative algorithm adapted to the slant-hole geometry. Sensitivity was measured over the range of slant angles using a disk source. Measured spatial resolution and sensitivity were compared to theoretical values. Contrast and CNR were measured using a breast phantom containing spherical lesions (6.2 mm and 7.8 mm diameter) and positioned over a range of depths in the phantom. The MBT and planar methods had equal scan time, and the count density in the breast phantom data was similar to that in clinical nuclear breast imaging. The MBT method used an iterative reconstruction algorithm combined with a postreconstruction Metz filter. Results The measured spatial resolution in planar images agreed well with theoretical calculations over the range of distances and slant angles. The measured FWHM was 9.7 mm at 50 mm distance. In reconstructed MBT images, the spatial resolution in the depth dimension was approximately 2.2 mm greater than the other two dimensions due to the limited angle data. The measured count sensitivity agreed closely with theory over all slant angles when using a wide energy window. At 0° slant angle, measured sensitivity was 19.7 counts sec -1 μ Ci -1 with the open energy window and 11.2 counts sec -1 μ Ci -1 with a 20% wide photopeak window (126 to 154 keV). The measured CNR in the MBT images was significantly greater than in the planar images for all but the lowest CNR cases where the lesion detectability was extremely low for both MBT and planar. The 7.8 mm lesion at 37 mm depth was marginally detectable in the planar image but easily visible in the MBT image. The improved CNR with MBT was due to a large improvement in contrast, which out-weighed the increase in image noise. Conclusion The spatial resolution and count sensitivity measurements with the prototype MBT system matched theoretical calculations, and the measured CNR in breast phantom images was generally greater with the MBT system compared to conventional planar imaging. These results demonstrate the potential of the proposed MBT system to improve lesion detection in nuclear breast imaging.

60 APPLIED LIFE SCIENCES↗

STATISTICAL ANALYSIS OF THE VERY QUIET SUN MAGNETISM

The behavior of the observed polarization amplitudes with spatial resolution is a strong constraint on the nature and organization of solar magnetic fields below the resolution limit. We study the polarization of the very quiet Sun at different spatial resolutions using ground- and space-based observations. It is shown that 80% of the observed polarization signals do not change with spatial resolution, suggesting that, observationally, the very quiet Sun magnetism remains the same despite the high spatial resolution of space-based observations. Our analysis also reveals a cascade of spatial scales for the magnetic field within the resolution element. It is manifest that the Zeeman effect is sensitive to the microturbulent field usually associated with Hanle diagnostics. This demonstrates that Zeeman and Hanle studies show complementary perspectives of the same magnetism.

79 ASTRONOMY AND ASTROPHYSICS↗

Improved optics for laser light scattering

Laser light scattering experiments contemplated for use in a microgravity environment must conform to a number of operational constraints which do not apply on Earth. In particular, the use of index matching fluid to control flare is unacceptable. Work to eliminate index matching fluids by the use of high spatial resolution receiving optics is described. By increasing on-axis spatial resolution flare from the sample cell walls (both the cell sample and cell air interfaces) can be effectively prevented from reaching the photodetector. In general, improving the on-axis discrimination degrades the angular resolution of a receiving optical train. Several different possible configurations of receiving optics are compared for their spatial resolution and angular resolution. For cylinder symmetric optics, the dual lens, fourier transform pair, receiving train with a center mask located between the lenses gives the best on-axis spatial resolution.

Cheung, H. Michael↗

Five Micron High Resolution MALDI Mass Spectrometry Imaging with Simple, Interchangeable, Multi-Resolution Optical System

High-spatial resolution mass spectrometry imaging (MSI) is crucial for the mapping of chemical distributions at the cellular and subcellular level. In this work, we improved our previous laser optical system for matrix-assisted laser desorption ionization (MALDI)-MSI, from ~9 μm practical laser spot size to a practical laser spot size of ~4 μm, thereby allowing for 5 μm resolution imaging without oversampling. This is accomplished through a combination of spatial filtering, beam expansion, and reduction of the final focal length. Most importantly, the new laser optics system allows for simple modification of the spot size solely through the interchanging of the beam expander component. Using 10×, 5×, and no beam expander, we could routinely change between ~4, ~7, and ~45 μm laser spot size, in less than 5 min. We applied this multi-resolution MALDI-MSI system to a single maize root tissue section with three different spatial resolutions of 5, 10, and 50 μm and compared the differences in imaging quality and signal sensitivity. We also demonstrated the difference in depth of focus between the optical systems with 10× and 5× beam expanders. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Resolution PET Detector. Final report

The objective of this project was to develop an understanding of the limits of performance for a high resolution PET detector using an approach based on continuous scintillation crystals rather than pixelated crystals. The overall goal was to design a high-resolution detector, which requires both high spatial resolution and high sensitivity for 511 keV gammas. Continuous scintillation detectors (Anger cameras) have been used extensively for both single-photon and PET scanners, however, these instruments were based on NaI(Tl) scintillators using relatively large, individual photo-multipliers. In this project we investigated the potential of this type of detector technology to achieve higher spatial resolution through the use of improved scintillator materials and photo-sensors, and modification of the detector surface to optimize the light response function.We achieved an average spatial resolution of 3-mm for a 25-mm thick, LYSO continuous detector using a maximum likelihood position algorithm and shallow slots cut into the entrance surface.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proof of concept for low-dose molecular breast imaging with a dual-head CZT gamma camera. Part I. Evaluation in phantoms

Purpose: Molecular breast imaging (MBI) is a nuclear medicine technology that uses dual-head cadmium zinc telluride (CZT) gamma cameras to image functional uptake of a radiotracer, Tc-99m sestamibi, in the breast. An important factor in adoption of MBI in the screening setting is reduction of the necessary administered dose of Tc-99m sestamibi from the typically used dose of 740 MBq to approximately 148 MBq, such that MBI's whole-body effective dose is comparable to that of screening mammography. Methods that increase MBI count sensitivity may allow a proportional reduction in the necessary administered dose. Our objective was to evaluate the impact of two count sensitivity improvement methods on image quality by evaluating count sensitivity, spatial resolution, and lesion contrast in phantom simulations. Methods: Two dual-head CZT-based MBI systems were studied: LumaGem and Discovery NM 750b. Two count sensitivity improvement methods were implemented: registered collimators optimized for dedicated breast imaging and widened energy acceptance window optimized for use with CZT. System sensitivity, spatial resolution, and tumor contrast-to-noise ratio (CNR) were measured comparing standard collimation and energy window setting [126-154 keV (+10%, -10%)] with optimal collimation and a wide energy window [110-154 keV (+10%, -21%)]. Results: Compared to the standard collimator designs and energy windows for these two systems, use of registered optimized collimation and wide energy window increased system sensitivity by a factor of 2.8-3.6. Spatial resolution decreased slightly for both systems with new collimation. At 3 cm from the collimator face, LumaGem's spatial resolution was 4.8 and 5.6 mm with standard and optimized collimation; Discovery NM 750b's spatial resolution was 4.4 and 4.6 mm with standard and optimized collimation, respectively. For both systems, at tumor depths of 1 and 3 cm, use of optimized collimation and wide energy window significantly improved CNR compared to standard settings for tumors 8.0 and 9.2 mm in diameter. At the closer depth of 1 cm, optimized collimation and wide energy window also significantly improved CNR for 5.9 mm tumors on Discovery NM 750b. Conclusions: Registered optimized collimation and wide energy window yield a substantial gain in count sensitivity and measurable gain in CNR, with some loss in spatial resolution compared to the standard collimator designs and energy windows used on these two systems. At low-count densities calculated to represent doses of 148 MBq, this tradeoff results in adequate count density and lesion contrast for detection of lesions {>=}8 mm in the middle of a typical breast (3 cm deep) and lesions {>=}6 mm close to the collimator (1 cm deep).

60 APPLIED LIFE SCIENCES↗

Super-Resolution from Space: Using MERRA-2 and MAIAC Satellite Imagery to Produce Daily Continuous 1 km PM2.5 Estimates

PM2.5 measurements from ground stations are the gold standard when available, but the expense and coverage of such stations limits widespread monitoring. Having accurate PM2.5 estimates outside the range of these stations is important for monitoring this crucial aspect of air quality. The goal of this project is to produce daily 1 km continuous PM2.5 estimates for the contiguous US relying primarily on satellite-derived data sources. This is important because models based on such data can be more easily expanded outside the study area and produce global estimates as well. The temporal availability of such data products is often weekly/daily, unlike land-use products with are often available at a yearly or worse temporal resolution. To achieve our goal, we use a couple of different deep neural network architectures to produce PM2.5 measurements at 10 km and 1 km resolution. We use two model architectures, a UNET-like model and a GAN-based model. We train both models using MERRA-2 data and MAIAC AOD data scaled to 10 km and 1 km for the two different prediction resolutions. MERRA-2 imagery is data rich with a wide range of geospatial variables at 50 km and has long historical availability (beginning in 1980). We’re also using higher spatial resolution MAIAC data at 1 km to provide finer resolution spatial context. This essentially leverages the spatial resolution of MAIAC data and the “wider” information of MERRA-2 data to predict PM2.5. For the target data we’re using a modeled 1 km PM2.5 dataset produced by Harvard to pre-train our models and then fine-tune our models using ground station measurements. Not only are our results comparable with the performance of the Harvard dataset, but can be generalized to any area or time where MERRA-2 and MAIAC data is available.

satellite imagery↗

WE-AB-BRB-12: Nanoscintillator Fiber-Optic Detector System for Microbeam Radiation Therapy Dosimetry

Purpose: Microbeam Radiation Therapy (MRT) is an experimental radiation therapy that has demonstrated a higher therapeutic ratio than conventional radiation therapy in animal studies. There are several roadblocks in translating the promising treatment technology to clinical application, one of which is the lack of a real-time, high-resolution dosimeter. Current clinical radiation detectors have poor spatial resolution and, as such, are unsuitable for measuring microbeams with submillimeter-scale widths. Although GafChromic film has high spatial resolution, it lacks the real-time dosimetry capability necessary for MRT preclinical research and potential clinical use. In this work we have demonstrated the feasibility of using a nanoscintillator fiber-optic detector (nanoFOD) system for real-time MRT dosimetry. Methods: A microplanar beam array is generated using a x-ray research irradiator and a custom-made, microbeam-forming collimator. The newest generation nanoFOD has an effective size of 70 µm in the measurement direction and was calibrated against a kV ion chamber (RadCal Accu-Pro) in open field geometry. We have written a computer script that performs automatic data collection with immediate background subtraction. A computer-controlled detector positioning stage is used to precisely measure the microbeam peak dose and beam profile by translating the stage during data collection. We test the new generation nanoFOD system, with increased active scintillation volume, against the previous generation system. Both raw and processed data are time-stamped and recorded to enable future post-processing. Results: The real-time microbeam dosimetry system worked as expected. The new generation dosimeter has approximately double the active volume compared to the previous generation resulting in over 900% increase in signal. The active volume of the dosimeter still provided the spatial resolution that meets the Nyquist criterion for our microbeam widths. Conclusion: We have demonstrated that real-time dosimetry of MRT microbeams is feasible using a nanoscintillator fiber-optic detector with integrated positioning system.

60 APPLIED LIFE SCIENCES↗

Photoabsorption Imaging at Nanometer Scales Using Secondary Electron Analysis

Optical imaging with nanometer resolution offers fundamental insights into light–matter interactions. Traditional optical techniques are diffraction limited with a spatial resolution >100 nm. Optical super-resolution and cathodoluminescence techniques have higher spatial resolutions, but these approaches require the sample to fluoresce, which many materials lack. Here, we introduce photoabsorption microscopy using electron analysis, which involves spectrally specific photoabsorption that is locally probed using a scanning electron microscope, whereby a photoabsorption-induced surface photovoltage modulates the secondary electron emission. We demonstrate spectrally specific photoabsorption imaging with sub-20 nm spatial resolution using silicon, germanium, and gold nanoparticles. Theoretical analysis and Monte Carlo simulations are used to explain the basic trends of the photoabsorption-induced secondary electron signal. Based on our current experiments and this analysis, we expect that the spatial resolution can be further improved to a few nanometers, thereby offering a general approach for nanometer-scale optical spectroscopic imaging and material characterization.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Complete Strain Mapping of Nanosheets of Tantalum Disulfide

Quasi-two-dimensional (quasi-2D) materials hold promise for future electronics because of their unique band structuresthat result in electronic and mechanical properties sensitive to crystal strains in all three dimensions. Quantifying crystal strain is a prerequisite to correlating it with the performance of the device, and calls for high resolution but spatially resolved rapid characterization methods. Here we show that using fly-scan nano X-ray diffraction we can accomplish a tensile strain sensitivity below 0.001% with a spatial resolution of better than 80 nm over a spatial extent of 100 µm on quasi 2D flakes of 1T-TaS2. Coherent diffraction patterns were collected from a ~100 nm thick sheet of 1T-TaS2 by scanning 12keV focused X-ray beam across and rotating the sample. We demonstrate that the strain distribution around micron and sub-micron sized ‘bubbles’ that are present in the sample may be reconstructed from these images. The experiments use state of the art synchrotron instrumentation, and will allow rapid and non-intrusive strain mapping of thin film samples and electronic devices based on quasi 2D materials.

nano X-ray diffraction↗

Broadband Fourier-Transform Optical Photothermal Infrared Spectroscopy and Imaging

Infrared (IR) spectroscopy is a powerful method for mapping chemical heterogeneity on the microscale. Synchrotron IR radiation uniquely provides a high brightness and broad bandwidth to further extend the capabilities of IR spectroscopic imaging. However, the diffraction-limited spatial resolution of IR spectroscopy is insufficient for studies requiring submicrometer spatial differentiation. Optical photothermal IR (O-PTIR) microscopy is a powerful, emerging method that overcomes the IR diffraction limit in IR hyperspectral imaging by employing a modulated IR beam and a visible probe laser beam to detect local temperature-induced modulation at the visible diffraction limit. In this work, we extend the spectral range of photothermal infrared measurements by incorporating a synchrotron IR source, demonstrating a combined synchrotron-based O-PTIR modality that enables high spatial resolution far-field chemical imaging spanning the entire mid-IR range. Both optical- and fluorescence-detected photothermal modalities were performed using a step-scan interferometer, demonstrating improved spectral range (541-4000 cm-1) when compared to optical photothermal microscopy with commercial laser sources (800-1800 cm-1 for this particular source) and improved spatial resolution, when compared to synchrotron microspectroscopy measurements. Following these initial validation studies, synchrotron Fourier-transform fluorescence-detected photothermal IR spectroscopy in combination with synchrotron microspectroscopy measurements was used to differentiate cells in mouse brain tissue sections, which requires submicron spatial resolutions beyond those accessible by IR spectroscopy alone.

Razumtcev, Aleksandr↗

Using Rose’s metal alloy as a pinhole collimator material in preclinical small-animal imaging: A Monte Carlo evaluation

Purpose: Pinhole collimation is the most common method of high-resolution preclinical single photon emission computed tomography imaging. The collimators are usually constructed from dense materials with high atomic numbers, such as gold and platinum, which are expensive and not always flexible in the fabrication step. In this work, the authors have investigated the properties of a fusible alloy called Rose’s metal and its potential in pinhole preclinical imaging. When compared to current standard pinhole materials such as gold and platinum, Rose’s metal has a lower density and a relatively low effective atomic number. However, it is inexpensive, has a low melting point, and does not contract when solidifying. Once cast, the piece can be machined with high precision. The aim of this study was to evaluate the imaging properties for Rose’s metal and compare them with those of standard materials. Methods: After validating their Monte Carlo code by comparing its results with published data and the results from analytical calculations, they investigated different pinhole geometries by varying the collimator material, acceptance angle, aperture diameter, and photon incident angle. The penetration-to-scatter and penetration-to-total component ratios, sensitivity, and the spatial resolution were determined for gold, tungsten, and Rose’s metal for two radionuclides, {sup 99}Tc{sup m} and {sup 125}I. Results: The Rose’s metal pinhole-imaging simulations show higher penetration/total and scatter/total ratios. For example, the penetration/total is 50% for gold and 75% for Rose’s metal when simulating {sup 99}Tc{sup m} with a 0.3 mm aperture diameter and a 60° acceptance angle. However, the degradation in spatial resolution remained below 10% relative to the spatial resolution for gold for acceptance angles below 40° and aperture diameters larger than 0.5 mm. Conclusions: Extra penetration and scatter associated with Rose’s metal contribute to degradation in the spatial resolution, but this degradation is not always substantial. The most important factor besides the collimator material was the acceptance angle. This should be kept to a minimum to prevent unnecessary scatter and penetration. For {sup 125}I, the difference in spatial resolution between gold and Rose’s metal is very small, 2.2% in the worst-case scenario. Based on these results, the authors conclude that Rose’s metal is an alternative to standard materials not only for low-energy photon imaging but also for medium-energy applications that require low-cost, flexible pinhole configurations and designs, and that can tolerate a degraded spatial resolution.

07 ISOTOPE AND RADIATION SOURCES↗

Initial assessment of multilayer silicon detectors for hard X-ray imaging

Silicon detectors with lower material budget, ultrafast readout and radiation hardness are under developments. These unique features make pixelized silicon sensors a good option for hard X-ray imaging. To verify the performance of spatial resolution and energy sensitivity of silicon sensors to hard X-rays, a two layer setup of Pixelink PL-D725MU sensors has been tested at the Argonne National Laboratory Advanced Photon Source (APS) ID-10 sector with 29.2 keV high photon flux (4.5 x 10(8) to 4.5 x 10(10) photons per second) X-rays. Better than 3 mu m spatial resolution and clear energy characterization have been achieved by both layers. Commercial CMOS sensors with superior spatial resolution could be used for phase contrast imaging in current synchrotrons. These studies pave the path for future multilayer ultrafast silicon sensor development with ns to sub-ns readout speeds in hard X-ray imaging at synchrotrons and XFEL beamlines.

Hard X-ray imaging↗

Characterization of statistical prior image constrained compressed sensing (PICCS): II. Application to dose reduction

Purpose: The ionizing radiation imparted to patients during computed tomography exams is raising concerns. This paper studies the performance of a scheme called dose reduction using prior image constrained compressed sensing (DR-PICCS). The purpose of this study is to characterize the effects of a statistical model of x-ray detection in the DR-PICCS framework and its impact on spatial resolution. Methods: Both numerical simulations with known ground truth and in vivo animal dataset were used in this study. In numerical simulations, a phantom was simulated with Poisson noise and with varying levels of eccentricity. Both the conventional filtered backprojection (FBP) and the PICCS algorithms were used to reconstruct images. In PICCS reconstructions, the prior image was generated using two different denoising methods: a simple Gaussian blur and a more advanced diffusion filter. Due to the lack of shift-invariance in nonlinear image reconstruction such as the one studied in this paper, the concept of local spatial resolution was used to study the sharpness of a reconstructed image. Specifically, a directional metric of image sharpness, the so-called pseudopoint spread function (pseudo-PSF), was employed to investigate local spatial resolution. Results: In the numerical studies, the pseudo-PSF was reduced from twice the voxel width in the prior image down to less than 1.1 times the voxel width in DR-PICCS reconstructions when the statistical model was not included. At the same noise level, when statistical weighting was used, the pseudo-PSF width in DR-PICCS reconstructed images varied between 1.5 and 0.75 times the voxel width depending on the direction along which it was measured. However, this anisotropy was largely eliminated when the prior image was generated using diffusion filtering; the pseudo-PSF width was reduced to below one voxel width in that case. In the in vivo study, a fourfold improvement in CNR was achieved while qualitatively maintaining sharpness; images also had a qualitatively more uniform noise spatial distribution when including a statistical model. Conclusions: DR-PICCS enables to reconstruct CT images with lower noise than FBP and the loss of spatial resolution can be mitigated to a large extent. The introduction of statistical modeling in DR-PICCS may improve some noise characteristics, but it also leads to anisotropic spatial resolution properties. A denoising method, such as the directional diffusion filtering, has been demonstrated to reduce anisotropy in spatial resolution effectively when it was combined with DR-PICCS with statistical modeling.

60 APPLIED LIFE SCIENCES↗

Comparing Thermal Neutron Scintillators for Use With SiPM-Readout Detectors

Scintillator-based thermal neutron detectors for scientific scattering facilities offer an effective combination of large-area coverage and good spatial resolution. At Oak Ridge National Laboratory, silicon photomultiplier (SiPM)-readout Anger cameras using 6 Li glass scintillators have been developed, but the spatial resolution of these detectors is limited by the relatively low light yield of the glass. Recently, several brighter scintillator compositions with sufficient 6 Li concentration have emerged as promising candidates for higher-resolution imaging. Here, in this work, we evaluate five scintillator materials: GS20, LiF/ZnS:Ag, LiF/ZnO:Zn, LiI:Eu, and Cs 2 LiYCl 6 :Ce, each mounted on a SiPM Anger camera. For each scintillator, the neutron detection efficiency, spatial resolution, and count rate capabilities were measured and compared. Each of the new compositions achieved a spatial resolution better than 0.5 mm, compared to 0.66 mm for GS20, with LiI:Eu reaching the best value of 0.32 mm. Although these compositions improve the spatial resolution of the Anger camera, their longer pulse decay times limit their use in high count rate applications, and the camera’s hardware must be optimized for the different properties of the new scintillators.

Neutron detectors↗

Reflectance spectra measurement plan of captured samples from Ryugu: current status

Hayabusa2 spacecraft is equipped with Optical Navigation Camera (ONC) andNear-infrared Spectrometer (NIRS3), and has obtained reflectance spectra of the C-type near-Earth asteroid Ryugu over a wavelength range of 0.40–0.95 μm and 1.8–3.2 μm, respectively. It was revealed that Ryugu exhibits globally very low albedo (less than 0.02 at 0.55 and 2.0 μm), a slightly positive spectral slope, and an ubiquitous weak but sharp OH absorption band centered at 2.72 μm,showing a little regional heterogeneities. Thus, the surface material of Ryugu can be estimated as relatively similar to moderately heated carbonaceous chondrites, e.g., moderately dehydrated CI and CM, and enriched in carbon (Kitazato et al., 2019; Sugita et al., 2019; Tatsumi et al., 2020).Hayabusa2 successfully has performed twice touch down operations, and the captured sample will be brought back to the Earth in late 2020 (Morota et al., 2020; Tachibana et al., in preparation). To clarify Ryugu’s mineralogical and physicochemical properties and their varieties, effective for spectral characteristics obtained by ONC and NIRS3, several grains are planned to be distributed to several primary analysis groups. In this study, we report the current status of our spectral analysis plan in Hayabusa2 MINeralogy and PETrology of coarse grains (MIN-PET CG) team led by T. Nakamura, and the latest rehearsal analysis result using carbonaceous chondrite samples. MIN-PET CG rehearsal measurements have been performed to obtain detailed spectral properties of Ryugu grains with diverse spatial resolutions ranging from μm to mm scale or larger; using a few mm size polished CM sample with several microscopic imaging spectrometers covering various spatial range; with 200 μmor finer spatial resolution at Institut d’Astrophysique Spatiale, ~50 and 150 μm spatial resolution invisible and IR ranges at Brown University, and with 40 μm or larger spatial resolution at Tohoku University, and using mm-size CM and CI grains with a diffuse reflectance spectrometer with a few mm resolution at Tohoku University. Diffuse reflectance spectroscopy measurements undergo to use several mm-size CM or CI chondrite grains with Bruker VERTEX 70v, which covers ~0.38–15 μm in wavelength. To keep returned samples out of atmosphere avoiding any terrestrial contamination, wehave prepared an air shutoff cell to put samples and standard materials together kept in a N2 purged condition (Amano et al., 2020). Samples are Murchison CM chondrite showing typically ~5%reflectance with a strong OH absorption band at ~2.8 μm, and laboratory heated CI chondrite showing~3% reflectance, and a weak OH absorption band at ~2.7 μm. We will perform (1) fixed angle condition as laboratory standard setting at incident, emission, and phase angles of 30°, 0°, 30°, or 0°,30°, 30°, and (2) various angle conditions for photometric corrections. Future lab analyses of samples returned from Ryugu will provide direct and detailed information on the mineralogical and physicochemical properties of Ryugu, and relationship of spectral characteristics obtained by remote sensing and laboratory instruments.

M. Matsuoka↗

A High-Pressure Gas-Scintillation-Proportional Counter for the Focus of a Hard-X-Ray Telescope

We are developing a high-pressure Gas Scintillation Proportional Counter (GSPC) for the focus of a balloon-borne hard-x-ray telescope. The device has a total active diameter of 50 mm, of which the central 20 mm only is used, and is filled with xenon + 4% helium at a total pressure of 10 6 Pa giving a quantum efficiency of greater than 85% up to 60 keV. The detector entrance is sealed with a beryllium window, 3-mm thick, which provides useful transmission down to 6 keV, way below the atmospheric cut-off at balloon float altitudes. Scintillation light exits the detector via a UV transmitting window in its base and is registered by a Hamamatsu position-sensitive crossed-grid-readout photomultiplier tube. Initial testing is underway, quantifying light yield and energy resolution. Following that, the spatial resolution and absolute efficiency will be calibrated. Simulations show that a spatial resolution of better than 0.5 mm FWHM should be achievable up to 60 keV, and this is well matched to the angular resolution and plate scale of the mirror system. The energy resolution will be around 5% at 22 keV. Full details of the instrument design and its performance will be presented. A first flight is scheduled for the Fall of 99, on a stratospheric balloon to be launched from Fort Sumner, New Mexico.

Austin, R. A.↗

Methods of photoelectrode characterization with high spatial and temporal resolution

Here, materials and photoelectrode architectures that are highly efficient, extremely stable, and made from low cost materials are required for commercially viable photoelectrochemical (PEC) water-splitting technology. A key challenge is the heterogeneous nature of real-world materials, which often possess spatial variation in their crystal structure, morphology, and/or composition at the nano-, micro-, or macro-scale. Different structures and compositions can have vastly different properties and can therefore strongly influence the overall performance of the photoelectrode through complex structure–property relationships. A complete understanding of photoelectrode materials would also involve elucidation of processes such as carrier collection and electrochemical charge transfer that occur at very fast time scales. We present herein an overview of a broad suite of experimental and computational tools that can be used to define the structure–property relationships of photoelectrode materials at small dimensions and on fast time scales. A major focus is on in situ scanning-probe measurement (SPM) techniques that possess the ability to measure differences in optical, electronic, catalytic, and physical properties with nano- or micro-scale spatial resolution. In situ ultrafast spectroscopic techniques, used to probe carrier dynamics involved with processes such as carrier generation, recombination, and interfacial charge transport, are also discussed. Complementing all of these experimental techniques are computational atomistic modeling tools, which can be invaluable for interpreting experimental results, aiding in materials discovery, and interrogating PEC processes at length and time scales not currently accessible by experiment. In addition to reviewing the basic capabilities of these experimental and computational techniques, we highlight key opportunities and limitations of applying these tools for the development of PEC materials.

08 HYDROGEN↗