Search NASA⌕ Search

SEARCH · Search NASA

Results for “storage performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

9975 SHIPPING PACKAGE PERFORMANCE OF ALTERNATE MATERIALS FOR LONG-TERM STORAGE APPLICATION

The Model 9975 shipping package specifies the materials of construction for its various components. With the loss of availability of material for two components (cane fiberboard overpack and Viton{reg_sign} GLT O-rings), alternate materials of construction were identified and approved for use for transport (softwood fiberboard and Viton{reg_sign} GLT-S O-rings). As these shipping packages are part of a long-term storage configuration at the Savannah River Site, additional testing is in progress to verify satisfactory long-term performance of the alternate materials under storage conditions. The test results to date can be compared to comparable results on the original materials of construction to draw preliminary conclusions on the performance of the replacement materials.

42 ENGINEERING↗

Impact of Parcel Size, Field Shape, Crop Yield, Storage Location, and Collection Equipment on the Performance of Single-Pass Cut-and-Chip Harvest System in Commercial Shrub Willow Fields

In this paper, an integrated system of harvesting, collecting, and transporting willow biomass crop to a storage site was modeled and evaluated using the IBSAL simulation model. A scenario analysis was used to quantify the impacts of five major input parameters on the performance of the integrated system. These parameters include parcel size, field shape, willow yield, distance to the storage site, and type of the collection equipment. Multiple performance indicators were identified to quantify the impacts on the system such as size of the equipment fleet, effective material and field capacity of the harvester, operating costs, and waiting times. The input data were collected from 36 commercial, short-rotation, shrub willow fields in northern New York State. The simulation results indicated that crop yield and type of collection equipment have the highest impact on operating costs and the equipment fleet size. As the size of equipment fleet increases in the system, variability in the system performance tends to increase. Field shape has the least impact on the overall system performance compared to the other four input parameters. The simulation results suggest that a combination of performance indicators need to be considered to evaluate the overall performance of the dynamic and complex system of harvesting, collection and transportation in commercial willow fields. The developed IBSAL model and scenario analysis approach can assist in planning this system based on the characteristics of field, crop, and logistical equipment to reach a high system performance.

54 ENVIRONMENTAL SCIENCES↗

Operational Benefits of Meeting California's Energy Storage Targets

In October 2013, the California Public Utilities Commission (CPUC) finalized procurement targets and other requirements to its jurisdictional utilities for a minimum of 1,325 MW of 'viable and cost-effective' energy storage systems by 2020. The goal of this study is to explore several aspects of grid operations in California and the Western Interconnection resulting from meeting the CPUC storage targets. We perform this analysis using a set of databases and grid simulation tools developed and implemented by the CPUC, the California Independent System Operator (CAISO), and the California Energy Commission (CEC) for the CPUC's Long-term Procurement Plan (LTPP). The 2014 version of this database contains information about generators, storage, transmission, and electrical demand, for California in the year 2024 for both 33% and 40% renewable energy portfolios. We examine the value of various services provided by energy storage in these scenarios. Sensitivities were performed relating to the services energy storage can provide, the capacity and duration of storage devices, export limitations, and negative price floor variations. Results show that a storage portfolio, as outlined by the CPUC, can reduce curtailment and system-wide production costs for 33% and 40% renewable scenarios. A storage device that can participate in energy and ancillary service markets provides the grid with the greatest benefit; the mandated storage requirement of 1,325 MW was estimated to reduce the total cost of production by about 78 million per year in the 33% scenario and 144 million per year in the 40% scenario. Much of this value is derived from the avoided start and stop costs of thermal generators and provision of ancillary services. A device on the 2024 California grid and participating in only ancillary service markets can provide the system with over 90% of the value as the energy and ancillary service device. The analysis points to the challenge of new storage providing regulation reserve, as the added storage could provide about 75% of the regulation up requirement for all of California, which would likely greatly reduce regulation prices and potential revenue. The addition of storage in California decreases renewable curtailment, particularly in the 40% RPS case. Following previous analysis, storage has a mixed impact on emissions, generally reducing emissions, but also creating additional incentives for increased emissions from out-of-state coal generations. Overall, storage shows significant system cost savings, but analysis also points to additional challenges associated with full valuation of energy storage, including capturing the operational benefits calculated here, but also recovering additional benefits associated avoided generation, transmission, and distribution capacity, and avoided losses.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Operational Benefits of Meeting California's Energy Storage Targets

In October 2013, the California Public Utilities Commission (CPUC) finalized procurement targets and other requirements to its jurisdictional utilities for a minimum of 1,325 MW of 'viable and cost-effective' energy storage systems by 2020. The goal of this study is to explore several aspects of grid operations in California and the Western Interconnection resulting from meeting the CPUC storage targets. We perform this analysis using a set of databases and grid simulation tools developed and implemented by the CPUC, the California Independent System Operator (CAISO), and the California Energy Commission (CEC) for the CPUC's Long-term Procurement Plan (LTPP). The 2014 version of this database contains information about generators, storage, transmission, and electrical demand, for California in the year 2024 for both 33 percent and 40 percent renewable energy portfolios. We examine the value of various services provided by energy storage in these scenarios. Sensitivities were performed relating to the services energy storage can provide, the capacity and duration of storage devices, export limitations, and negative price floor variations. Results show that a storage portfolio, as outlined by the CPUC, can reduce curtailment and system-wide production costs for 33 percent and 40 percent renewable scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Stable Vanadium Redox-Flow Battery with High Energy Density for Large-scale Energy Storage

Low cost, high performance redox flow batteries are highly demanded for up to multi-megawatt levels of renewable and grid energy storage. Here, we report a new vanadium redox flow battery with a significant improvement over the current technologies. This new battery utilizes a sulfate-chloride mixed solution, which is capable of dissolving more than 2.5 M vanadium or about a 70% increase in the energy storage capacity over the current vanadium sulfate system. More importantly, the new electrolyte remains stable over a wide temperature range of -5 to 60oC, potentially eliminating the need of active heat management. Its high energy density, broad operational temperature window, and excellent electrochemical performance would lead to a significant reduction in the cost of energy storage, thus accelerating its market penetration.

energy storage↗

Distributed Large Data-Object Environments: End-to-End Performance Analysis of High Speed Distributed Storage Systems in Wide Area ATM Networks

We have developed and deployed a distributed-parallel storage system (DPSS) in several high speed asynchronous transfer mode (ATM) wide area networks (WAN) testbeds to support several different types of data-intensive applications. Architecturally, the DPSS is a network striped disk array, but is fairly unique in that its implementation allows applications complete freedom to determine optimal data layout, replication and/or coding redundancy strategy, security policy, and dynamic reconfiguration. In conjunction with the DPSS, we have developed a 'top-to-bottom, end-to-end' performance monitoring and analysis methodology that has allowed us to characterize all aspects of the DPSS operating in high speed ATM networks. In particular, we have run a variety of performance monitoring experiments involving the DPSS in the MAGIC testbed, which is a large scale, high speed, ATM network and we describe our experience using the monitoring methodology to identify and correct problems that limit the performance of high speed distributed applications. Finally, the DPSS is part of an overall architecture for using high speed, WAN's for enabling the routine, location independent use of large data-objects. Since this is part of the motivation for a distributed storage system, we describe this architecture.

Johnston, William↗

Implementation and Evaluation of Active Storage in Modern Parallel File Systems

Active Storage is a technology aimed at reducing the bandwidth requirements of current supercomputing systems, and leveraging the processing power of the storage nodes used by some modern file systems. Active Storage achieves both objectives by moving certain processing tasks to the storage nodes, near the data they manage. Our proposal for Active Storage has several key features: user-space implementation which facilitates the port to different file systems, analytical model to anticipate the performance of Active Storage with respect to a traditional system, support for striped files and complex format files such as netCDF, scientific-friendly programming and runtime environment, etc.

99 GENERAL AND MISCELLANEOUS↗

Technical assessment of compressed hydrogen storage tank systems for automotive applications.

The performance and cost of compressed hydrogen storage tank systems has been assessed and compared to the U.S. Department of Energy (DOE) 2010, 2015, and ultimate targets for automotive applications. The on-board performance and high-volume manufacturing cost were determined for compressed hydrogen tanks with design pressures of 350 bar ({approx}5000 psi) and 700 bar ({approx}10,000 psi) capable of storing 5.6 kg of usable hydrogen. The off-board performance and cost of delivering compressed hydrogen was determined for hydrogen produced by central steam methane reforming (SMR). The main conclusions of the assessment are that the 350-bar compressed storage system has the potential to meet the 2010 and 2015 targets for system gravimetric capacity but will not likely meet any of the system targets for volumetric capacity or cost, given our base case assumptions. The 700-bar compressed storage system has the potential to meet only the 2010 target for system gravimetric capacity and is not likely to meet any of the system targets for volumetric capacity or cost, despite the fact that its volumetric capacity is much higher than that of the 350-bar system. Both the 350-bar and 700-bar systems come close to meeting the Well-to-Tank (WTT) efficiency target, but fall short by about 5%.

03 NATURAL GAS↗

Technical assessment of compressed hydrogen storage tank systems for automotive applications.

The performance and cost of compressed hydrogen storage tank systems has been assessed and compared to the U.S. Department of Energy (DOE) 2010, 2015, and ultimate targets for automotive applications. The on-board performance and high-volume manufacturing cost were determined for compressed hydrogen tanks with design pressures of 350 bar ({approx}5000 psi) and 700 bar ({approx}10,000 psi) capable of storing 5.6 kg of usable hydrogen. The off-board performance and cost of delivering compressed hydrogen was determined for hydrogen produced by central steam methane reforming (SMR). The main conclusions of the assessment are that the 350-bar compressed storage system has the potential to meet the 2010 and 2015 targets for system gravimetric capacity but will not likely meet any of the system targets for volumetric capacity or cost, given our base case assumptions. The 700-bar compressed storage system has the potential to meet only the 2010 target for system gravimetric capacity and is not likely to meet any of the system targets for volumetric capacity or cost, despite the fact that its volumetric capacity is much higher than that of the 350-bar system. Both the 350-bar and 700-bar systems come close to meeting the Well-to-Tank (WTT) efficiency target, but fall short by about 5%. These results are summarized.

03 NATURAL GAS↗

Effect of Thermal Storage on the Emissions and Efficiency Performance of a Wood Pellet-Fired Residential Boiler

Wood pellet boilers for residential heating applications offer the promise of low emissions, high efficiency, and automatic operation. However, when operated in the field, these units operate often at very low loads causing them to cycle. In this study, the performance of a 25-kW modern pellet boiler under emulated field conditions and fixed nominal loads of 15% and 100% has been studied in a lab—with and without a buffer tank. A dilution tunnel approach was used for the measurement of particulate emissions, in accordance with U.S. certification testing requirements under EPA Methods 28 WHH and 28 WHH PTS. Results show that increasing the amount of thermal storage used decreases cycling rates leading to decreased emissions and increased efficiency. Without thermal storage, integrated efficiency over a 15% load test period was 57%, compared to 74% when thermal storage was used. Particulate emissions were 180 mg/MJ and 64 mg/MJ for the 15% load case without and with thermal storage, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

I/O Performance of Virtualized Cloud Environments

The scientific community is exploring the suitability of cloud infrastructure to handle High Performance Computing (HPC) applications. The goal of Magellan, a project funded through DOE ASCR, is to investigate the potential role of cloud computing to address the computing needs of the Department of Energy?s Office of Science, especially for mid-range computing and data-intensive applications which are not served through existing DOE centers today. Prior work has shown that applications with significant communication orI/O tend to perform poorly in virtualized cloud environments. However, there is a limited understanding of the I/O characteristics in virtualized cloud environments. This paper will present our results in benchmarking the I/O performance over different cloud and HPC platforms to identify the major bottlenecks in existing infrastructure. We compare the I/O performance using IOR benchmark on two cloud platforms - Amazon and Magellan. We analyze the performance of different storage options available, different instance types in multiple availability zones. Finally, we perform large-scale tests in order to analyze the variability in the I/O patterns over time and region. Our results highlight the overhead and variability in I/O performance on both public and private cloud solutions. Our results will help applications decide between the different storage options enabling applications to make effective choices.

97 MATHEMATICS AND COMPUTING↗

Determination of Duty Cycle for Energy Storage Systems in a Renewables (Solar) Firming Application

This report supplements the document, “Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems,” issued in a revised version in April 2016, which will include the renewables (solar) firming application for an energy storage system (ESS). This report provides the background and documentation associated with the determination of a duty cycle for an ESS operated in a renewables (solar) firming application for the purpose of measuring and expressing ESS performance in accordance with the ESS performance protocol.

25 ENERGY STORAGE↗

PCM-Based Durable Write Cache for Fast Disk I/O

Flash based solid-state devices (FSSDs) have been adopted within the memory hierarchy to improve the performance of hard disk drive (HDD) based storage system. However, with the fast development of storage-class memories, new storage technologies with better performance and higher write endurance than FSSDs are emerging, e.g., phase-change memory (PCM). Understanding how to leverage these state-of-the-art storage technologies for modern computing systems is important to solve challenging data intensive computing problems. In this paper, we propose to leverage PCM for a hybrid PCM-HDD storage architecture. We identify the limitations of traditional LRU caching algorithms for PCM-based caches, and develop a novel hash-based write caching scheme called HALO to improve random write performance of hard disks. To address the limited durability of PCM devices and solve the degraded spatial locality in traditional wear-leveling techniques, we further propose novel PCM management algorithms that provide effective wear-leveling while maximizing access parallelism. We have evaluated this PCM-based hybrid storage architecture using applications with a diverse set of I/O access patterns. Our experimental results demonstrate that the HALO caching scheme leads to an average reduction of 36.8% in execution time compared to the LRU caching scheme, and that the SFC wear leveling extends the lifetime of PCM by a factor of 21.6.

99 GENERAL AND MISCELLANEOUS↗

Determination of Duty Cycle for Energy Storage Systems in a PV Smoothing Application

This report supplements the document, "Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems," issued in a revised version in April 2016 (see [4]), which will include the photovoltaic (PV) smoothing application for an energy storage system (ESS). This report provides the background and documentation associated with the determination of a duty cycle for an ESS operated in a PV smoothing application for the purpose of measuring and expressing ESS performance in accordance with the ESS performance protocol. ACKNOWLEDGEMENTS The authors gratefully acknowledge the support of Dr. Imre Gyuk, program manager for the DOE Energy Storage Systems Program. The authors would also like to express their appreciation to all the stakeholders who participated as members of the PV Smoothing Subgroup. Without their thoughtful input and recommendations, the definitions, metrics, and duty cycle provided in this report would not have been possible. A complete listing of members of the PV Smoothing Subgroup appears in the first chapter of this report. Special recognition should go to the staffs at Pacific Northwest National Laboratory (PNNL) and Sandia National Laboratories (SNL) in collaborating on this effort. In particular, Mr. David Conover and Dr. Vish Viswanathan of PNNL and Dr. Summer Ferreira of SNL were especially helpful in their suggestions for the determination of a duty cycle for the PV Smoothing application.

25 ENERGY STORAGE↗

Electrochemical energy storage systems for solar thermal applications

Existing and advanced electrochemical storage and inversion/conversion systems that may be used with terrestrial solar-thermal power systems are evaluated. The status, cost and performance of existing storage systems are assessed, and the cost, performance, and availability of advanced systems are projected. A prime consideration is the cost of delivered energy from plants utilizing electrochemical storage. Results indicate that the five most attractive electrochemical storage systems are the: iron-chromium redox (NASA LeRC), zinc-bromine (Exxon), sodium-sulfur (Ford), sodium-sulfur (Dow), and zinc-chlorine (EDA).

Krauthamer, S.↗

Architectural constructs of Ampex DST

The DST 800 automated library is a high performance, automated tape storage system, developed by AMPEX, providing mass storage to host systems. Physical Volume Manager (PVM) is a volume server which supports either a DST 800, DST 600 stand alone tape drive, or a combination of DST 800 and DST 600 subsystems. The objective of the PVM is to provide the foundation support to allow automated and operator assisted access to the DST cartridges with continuous operation. A second objective is to create a data base about the media, its location, and its usage so that the quality and utilization of the media on which specific data is recorded and the performance of the storage system may be managed. The DST tape drive architecture and media provides several unique functions that enhance the ability to achieve high media space utilization and fast access. Access times are enhanced through the implementation of multiple areas (called system zones) on the media where the media may be unloaded. This reduces positioning time in loading and unloading the cartridge. Access times are also reduced through high speed positioning in excess of 800 megabytes per second. A DST cartridge can be partitioned into fixed size units which can be reclaimed for rewriting without invalidating other recorded data on the tape cartridge. Most tape management systems achieve space reclamation by deleting an entire tape volume, then allowing users to request a 'scratch tape' or 'nonspecific' volume when they wish to record data to tape. Physical cartridge sizes of 25, 75, or 165 gigabytes will make this existing process inefficient or unusable. The DST cartridge partitioning capability provides an efficient mechanism for addressing the tape space utilization problem.

Johnson, Clay↗

Nanostructures for Electrical Energy Storage (NEES) (2020 Final Technical Report)

Nanostructures for Electrical Energy Storage (NEES, www.efrc.umd.edu) was an Energy Frontier Research Center supported by the DOE Office of Science, Basic Energy Sciences, from 8/1/2009 to 7/31/2020. Led by the University of Maryland, NEES enjoyed extensive collaborations with its funded partners, including two DOE Laboratories and six universities. The NEES vision has been to reveal a set of scientific insights and design principles that can underpin a next-generation electrical energy storage approach, building on advances in nanoscale science and technology to achieve simultaneous high power and high energy over extended charge/discharge cycling. The vision is motivated by the recognition that scaling into the nano regime opens the door to new physical phenomena and that the tools enlisted in nanoscale research provide major new opportunities for the synthesis not only of materials at molecular scale but for structures at nano scale and above. NEES has translated this vision into its research program based on two observations. First, while the behavior of ions and electrons in electrolytes and in electrode materials is crucial to electrical energy storage (or more appropriately electrochemical energy storage), it is the transport of ion and electron charge between different structural components of a storage device that ultimately determine its performance. With it well recognized that the choice of electrode materials typically constrain ion transport kinetics as well as maximum ion concentration, the search for better electrode materials has been a primary driver of battery research. At the same time the synthesis of electrodes is typically based on aggregation of particles with varying size, shape, and orientation in the electrode. Together with the presence of additional materials to impart electrical conductivity and cohesion to the composite electrode, change in electrode materials is necessarily accompanied by structural changes at the nano/micro scale that are difficult to categorize and manage. From the beginning, NEES’ vision has been to create and study simpler, highly controlled spatial arrangements of known materials as battery components (electrodes, current collectors, and electrolyte) and to understand how design and structure above the molecular scale determines the energy storage performance available from known materials. Second, advances in nanoscience dramatically expanded the portfolio of synthesis methods, structural motifs, and new phenomena available for research. Some of these gave rapid access to new building blocks at the deep nanoscale (e.g., carbon nanotubes grown by self-assembly, nanoscale arrays formed by electrochemical self-alignment, monolayer films controlled by self-limiting reaction). Such advances served as the enabler for the NEES vision to be pursued experimentally through study of 3D structures created and controlled at the nano, micro, and meso scales. Here, we use meso as in the BES MESO Report, implying not only intermediate or varying length scales, but very much the way behavior is influenced by other factors including aggregation of nanocomponents at different densities and spatial configurations, statistical variations in the aggregates, hierarchical architectures in which they can be assembled, or local 3D configurations that result from the architectures. Over its life cycle, NEES has pursued two overarching goals: (1) to understand the scientific fundamentals of electrochemical storage from the nanoscale to the mesoscale; and (2) to create and learn from innovative, controlled, heterogeneous nanostructures, where such nanostructures can enable the first goal and serve as models for future paradigms in energy storage. Specific goals have included: Synthesize heterogeneous nanostructures comprised of multiple materials arranged in controlled fashion and characterize their behavior; Demonstrate and elucidate design principles for achieving simultaneous high power and high energy; Develop materials processes which enable precision control of thin layers and 3D structures; Investigate the impact of artificial interphases on electrode stability during ion insertion/deinsertion; Create dense arrays of nanostructures to understand how the architecture of these assemblies, along with nanostructure design, influences energy storage behavior at the mesoscale; Identify and understand the consequences of nanoconfinement and local inhomogeneities in 3D mesoscale arrays; Develop and apply computational models to stimulate, guide and interpret experiments.

25 ENERGY STORAGE↗