Search NASA⌕ Search

SEARCH · Search NASA

Results for “task”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

SU-G-JeP4-04: Commissioning and Acceptance Testing of Optical Surface Monitoring System On TrueBEAM STx as Per Task Group 147

Purpose: Optical Surface Monitoring system (OSMS) have been recently introduced by Varian for initial patient positioning and real-time monitoring during complex radiotherapy treatment. The purpose of this work was to implement TG 147 with OSMS. Methods: Recently we installed OSMS first of its kind in India on trueBEAM STx at our Institue. The OSMS is composed of a three cameras ceiling mounted and a Workstation. The following tests were performed to validate the system a. Calibration b. System reproducibility and drift c. Static localization displacement accuracy and d. Dynamic radiation gating delivery. The Calibration procedure consists of Daily,Monthly and MV Radiation Isocenter Calibration. The reproducibility of system was tested by monitoring the varian gating phantom test pattern for at least 120 min. Each recorded pattern was registered to the reference surface to calculate the required couch adjustment. To measure the static localization displacement accuracy of the system to detect and quantify patient shift relative to a reference image,we compared the shift detected by the surface imaging system with known couch transitions in a phantom study. The phantom was set in a motion and the radiation beam was holded by changing the threshold in the software for different clinical setups to test the dynamic radiation gating capability. Results: Daily calibration was within ±0.5 mm. The MV radiation isocentre with respect to cameras was less than 1 mm in translational axis and less than 0.5° for rotational axis. The reproducibility was found to be 0.4 mm. The maximum static displacement accuracy was 0.75 mm for the three translational axis, and less than 0.5° for rotational axis. The system was able to hold the beam with a minimum threshold of 1 mm. Conclusion: A quality assurance process has been developed as per TG 147 for the clinical implementation of an OSMS in radiation therapy.

60 APPLIED LIFE SCIENCES↗

Assessing task performance in FFDM, DBT, and synthetic mammography using uniform and anthropomorphic physical phantoms

Purpose The purpose of this study is to quantify the differences in detectability between full field digital mammography (FFDM), digital breast tomosynthesis (DBT), and synthetic mammography (SM) for challenging, low contrast signals, in the context of both a uniform and an anthropomorphic, textured phantom. Methods Images of the phantoms were acquired using a Hologic Selenia Dimensions system. Images were taken at 50%, 100%, and 200% of the dose delivered under automatic exposure control (AEC). Low‐contrast disks, created using an inkjet printer with iodine‐doped ink, were inserted into the phantom. The disks varied in diameter from 210 to 630 μ m, and in local contrast from 1.1% to 2.8% in regular increments. Human observers located the disks in a 4 alternative forced choice experiment. Proportion correct (PC) was computed as the number of correct localizations out of the total number of tries. Results Overall, scores from FFDM and DBT were consistently greater than scores from SM. At an exposure corresponding to the AEC setting, mean PC scores for the largest disks with the uniform phantom were 0.80 for FFDM, 0.83 for DBT, and 0.66 for SM, with the same rank ordering at other doses. Scores were similar but lower for the nonuniform background. At an exposure twice the AEC setting, however, the difference between uniform and nonuniform scores was most pronounced for DBT alone. Differences between scores for FFDM and SM were statistically significant, while those between FFDM and DBT were not. Scores were used to compute the minimum contrast level needed to reach 62.5% detection rate. The minimum contrast for SM was 36%–81% higher compared to FFDM or DBT, in either background. Conclusions This study shows that an anthropomorphic phantom and lesions inserts may be used to conduct a reader study. Detectability was significantly lower for synthetic mammography than for FFDM or DBT, for all conditions. Additionally, observer performance was consistently lower for the anthropomorphic phantom, indicating the greater challenge due to anatomical background. Because of this, it may be important to use realistic phantoms in observer studies in order to draw conclusions that are more clinically relevant.

Ikejimba, Lynda C.↗

Hadron structure and spectroscopy at COMPASS. Overview of certain tasks

COMPASS is a fixed-target experiment at CERN with a long history and intense and diverse physics programme. In the Review we consider particular points of the existing and possible future programme: test of the chiral theory predictions with hadron beam, search for exotic charmonia, study of the EMC effect in the Drell–Yan process, search for production of bound p p-bar states and study of prompt photon production in hadronic interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Decision Making Under Uncertainty Human Subjects Data - Fire Evacuation Task

This dataset contains de-identified data from human subjects experiments, along with the images and code that were used to run the experiments (as a crowdsourced online study). In this study, participants were shown the probability of a house being in the burn zone of a wildfire. They were asked if they would stay in the house or evacuate in that scenario. The probability information was presented in different ways, including text and maps. The studies tested the impact of different visual cues on the participants' patterns of decisions.

Matzen, Laura E. [Sandia National Laboratories (SN↗

Automata-based Debugging for Dissimilar Parallel Tasks

AutomaDeD is a tool that automatically diagnoses performance and correctness faults in MPI applications. It creates time and control-flow models of processes in an MPI program, and when a failure occus, these models are analyzed probabilistically to find the origin of the failure. The output of the tool is MPI processes ranked by the abnormality degree and regions of code where faults are first manifested. The granularity of code region is an MPI call or a computation region between two MPI calls.

Source record↗

iDASH 2018: Task 1

The goal of this track is to develop blockchain-based ledgering solutions to log and query the user activities of accessing genomic datasets (e.g., GTEx) across multiple sites.

Pattengale, Nick↗

Multi-Task Learning Software Suite

Software suite with multitask learning models. The pipeline includes functionality to process data, train, evaluate models, and generate reports.

Goncalves, Andre↗

LivermorE Al Projector for Computed Tomography Tasks

With recent computed tomography (CT) efforts using Artificial Intelligence (AI) and Deep Learning (DL)techniques, there is a strong need for differentiable forward projection models that can be integrated into existing DL frameworks. We developed a pytorch-based package library providing differentiable forward and back projection functions and classes to facilitate forward and back propagation of CT operations in the training procedure. This forward projectors support three CT projection geometries: cone, parallel and modular beams. This package can be used with both CPU and GPU with CUDA.

Kim, Hyojin↗

Task Information Presentation System

Demonstrate a novel computer-based procedure solution for a multi-unit power plant. TIPS is developed to demonstrate a way to operate a highly automated plant. Currently, there are no plants (nuclear or non-nuclear) that can support this high level of automation. The purpose of TIPS is to help the industries think beyond the current conduct of operations. TIPS is designed to work with the GSE Systems' Combine-cycle gas turbine power plant simulator. TIPS uses the plant data from the simulator to make the user experience of the computer-based procedure more realistic.

Oxstrand, Johanna↗

An Open-source Llm Enhanced-tool Specialized In Helping Moose Related Problems And Tasks

MOOSEenger is an open-source, terminal-first chat application for the MOOSE ecosystem that couples specialized parsing of MOOSE documentation and “.i” input files with retrieval-augmented generation to deliver grounded answers about multiphysics modeling and workflows. It includes dedicated readers for MOOSE-style HTML and a pyhit-based parser that uses the MOOSE syntax tree to preserve block structure and attach retrieval metadata. A data-ingestion pipeline performs semantic chunking into atomic facts and stores them hierarchically in a local Chroma vector database that maintains parent–child relationships across documents; the system can ingest directories, individual files, and single-page web content, and it provides CRUD operations (insert, update, delete) to manage the corpus. At query time, relevant chunks are embedded, retrieved, and fused into the model context, with interactive features such as token streaming, persistent chat history, and dynamic RAG (retrieval triggered by user input or intermediate model output). Deployment is flexible: MOOSEenger runs with local Ollama models or remote Hugging Face/OpenAI backends—typically coordinating generation, lightweight tagging/summarization, and embeddings across three models—and it also supports a server mode and integration with the VS Code Continue interface.

Li, Mengnan [Idaho National Laboratory (INL), Idah↗

Surrogate modeling of Cellular-Potts agent-based models as a segmentation task using the U-Net neural network architecture

The Cellular-Potts model is a powerful and ubiquitous framework for developing computational models for simulating complex multicellular biological systems. Cellular-Potts models (CPMs) are often computationally expensive due to the explicit modeling of interactions among large numbers of individual model agents and diffusive fields described by partial differential equations (PDEs). In this work, we develop a convolutional neural network (CNN) surrogate model using a U-Net architecture that accounts for periodic boundary conditions. We use this model to accelerate the evaluation of a mechanistic CPM previously used to investigate in vitro vasculogenesis. The surrogate model was trained to predict 100 computational steps ahead (Monte-Carlo steps, MCS), accelerating simulation evaluations by a factor of 562 times compared to single-core CPM code execution on CPU. Over short timescales of up to 3 recursive evaluations, or 300 MCS, our model captures the emergent behaviors demonstrated by the original Cellular-Potts model such as vessel sprouting, extension and anastomosis, and contraction of vascular lacunae. This approach demonstrates the potential for deep learning to serve as a step toward efficient surrogate models for CPM simulations, enabling faster evaluation of computationally expensive CPM simulations of biological processes.

97 MATHEMATICS AND COMPUTING↗